About this opportunity
The Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 4, specifically the Lebanon VA Medical Center in Lebanon, Pennsylvania, is seeking a design-build contractor to replace fire alarm systems campus-wide under project number 595-26-201. The procurement involves replacing existing EST-3 fire alarm and mass notification panels with new EST-4 or approved equivalent panels throughout the medical center campus, requiring the prime contractor to partner with an architectural engineering firm to provide comprehensive design-build services. The contractor must provide all labor, materials, tools, equipment, permits, licenses, and supervision necessary for both design and construction phases, ensuring compliance with NFPA standards, EPA requirements, VA specifications, and local Lebanon requirements. The contract will be awarded as a single Firm-Fixed-Price award using a Best Value evaluation approach that considers both evaluation factors and price through a two-phase solicitation process. The solicitation is expected to be issued on or about October 16, 2025, with proposals due by November 18, 2025, at 4:00 PM Eastern Time.
This opportunity is set aside exclusively for Service-Disabled Veteran-Owned Small Business (SDVOSB) contractors under NAICS code 236220, with prospective contractors required to be registered in the System Award Management database and verified by the Small Business Administration's Veteran Small Business Certification program. The project value is estimated to fall between $1-2 million, with a performance period of 280 calendar days from the Notice to Proceed. The scope encompasses multiple buildings including 17-B, 18-B, 19-3, and Building 104, requiring installation of new fiber optic infrastructure, monitoring computers, printers, and comprehensive system replacements. Key deliverables include conducting site investigations, creating device location maps, providing CAD as-built floor plans, and delivering a 24-month warranty for programming corrections along with manufacturer-led training. The contractor must ensure minimal disruption to ongoing hospital operations during the construction phase while meeting all VA design guides and policy standards.
Notice text
The Veterans Integrated Service Network 04 (VISN 04) Contracting Office / Lebanon Veteran Administration Medical Center anticipates soliciting a Request for Proposal (RFP) and subsequently awarding a single, Firm-Fixed-Price contract that will be the Best Value to the Government based on evaluation factors and price. The prime contractor is to contract/partner with an Architect Engineering firm to provide design-build services necessary for completion of designs and the construction of the Campus Wide Fire Alarm Replacement project (This is a Design-Build project). All design and construction must be in compliance with applicable codes, VA Design Guides, VA policy/standards, and the terms of this contract. The contractor shall provide all tools, travel, trades, labor, materials, permits, licenses, and supervision for construction of the Campus Wide Fire Alarm Replacement design-build project as specified in the Scope of Work.
Note: This notice is NOT a request for proposal at this time.
Project Scope Summary
The Design-Build team shall provide all labor, materials, tools and equipment, and design-build services necessary for design and construction of a project described here in other specific tasks as further defined by this request for proposal (RFP) of Project No. 595-26-201 Campus Wide Fire Alarm Replacement. The project shall replace the existing EST-3 fire alarm and mass notification panels with new fire alarm and mass notification panels that are EST-4 or approved equal, campus wide. The resultant contract of this procurement is to provide required design and perform construction of completed design work. The project shall be designed and completed in accordance with current VA guidelines, NFPA (National Fire Protection Association), EPA requirements, VA Specifications and developed specifically to meet local requirements for the Lebanon VA Medical Center in Lebanon PA. The resultant contract of this procurement is to provide required design completion of the referenced project and perform construction of completed design work.
Selection/Administration:
This project is a Best Value tradeoff two-phase design-build solicitation. Phase I proposals will be evaluated to determine which offerors will be selected to provide an offer for Phase II of the solicitation. The Request for Proposal shall set forth the requirements for responding to Phase I of the solicitation as well as all evaluation factors for both Phases I and Phase II.
The solicitation and scope of work will be available at Contracting Opportunities http://SAM.gov. Amendments to the solicitation will also be posted on this website. All parties must obtain solicitation documents and amendments to the solicitation through the website. Hard copies will not be mailed. It is the responsibility of the Contractor to frequently check the website for all notices, amendments, etc., regarding this solicitation. The Government will not be responsible for any notification not sent or received by the Contractor regarding the solicitation. The contract will be awarded in accordance with the procedures specified in the solicitation.
This contract is being procured in accordance with the Federal Acquisition Regulation (FAR) Subpart 36.3 Two-Phase Design-Build Selection Procedures. This contract is set-aside 100% for Service-Disabled Veteran-Owned Small Business s (SDVOSB) capable of completing work under the North American Industrial Classification System (NAICS) code 236220 Commercial & Industrial Building & Construction with a size standard of $45.0 million in annual receipts for the past three years. The contract will be awarded as a Firm Fixed Price (FFP) contract.
Period of Performance: 280 calendar days from Notice to Proceed (NTP)
Magnitude (IAW VAAR 836.204): Between $1,000,000.00 and $2,000,000.00.
The solicitation will be issued on or about October 16th, 2025.
All questions pertaining to this solicitation must be received in writing via e-mail to Amanda.Murphy5@va.gov. NO TELEPHONE REQUESTS WILL BE HONORED. All questions and Government responses will be posted to the SAM.gov website.
A pre-bid conference/site visit will be conducted at the Lebanon VA Medical Center for Phase I of the Two-Phase Design-Build. The date and time of this site visit will be provided in the solicitation. Attendees will meet at the front entrance of Building 19 on the Lebanon VAMC Campus. A pre-bid site visit for those contractors selected to participate for Phase II will be held at a date and time to be determined. All respondents must be registered in the System Award Management System (SAM) database at time of Phase I submittal. Offerors must be verified by the Small Business Administration (SBA) Veteran Small Business Certification (VetCert) https://veterans.certify.sba.gov/ at time of Phase I submittal. Any offeror not SBA or SAM verified at time of proposal submittal will be disqualified and proposal will be rejected.
Files
| File | Type | Posted |
|---|---|---|
| 36C24426R0008.docx | DOCX document | |
| SOW - Replace Fire Alarm Panels.pdf |
Notice history
| Notice | Type | Posted |
|---|---|---|
| Z1DA--Copy of NRM| 595-26-201 Campus Wide Fire Alarm Replacement DB (VA-26-00010241) | Solicitation | |
| This notice | Pre-Solicitation |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| Y1DA--Project620-22-110 Replace and Upgrade Fire alarm System at Montrose VAMC | Veterans Integrated Service Network 2 | Service-Disabled Veteran-Owned Small Business | |
| Z1DA--Upgrade Fire Alarm System Construction 676-22-110 | Veterans Integrated Service Network 12 | Service-Disabled Veteran-Owned Small Business | |
| J042--Fire Alarm, Suppression Systems, and Hood Testing, Inspection, and Certification Services - SAVAHCS | Veterans Integrated Service Network 22 | Service-Disabled Veteran-Owned Small Business | |
| J012-- Fire Alarm Suppression Maintenance & Repair Services | Veterans Integrated Service Network 16 | Service-Disabled Veteran-Owned Small Business | |
| 540-22-700 | EHRM Infrastructure Upgrades Construction | Clarksburg WV | VA Technology Acquisition Center | Service-Disabled Veteran-Owned Small Business |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity