Y1DA--Add Emergency Power to Central Chiller Plant 506-21-110
Closed Solicitation Posted
This opportunity was awarded. See the award notice from .
- Solicitation number
- 36C25023B0003
- Agency
-
Veterans Integrated Service Network 10
Veterans Health Administration, Department of Veterans Affairs
- Responses due
- Set-aside
- Service-Disabled Veteran-Owned Small Business
Opportunity facts
- NAICS code
- 238210 Electrical Contractors and Other Wiring Installation Contractors
- Place of performance
- Ann Arbor, Michigan 48105, United States
Notice details come from SAM.gov. Updated .
About this opportunity
This solicitation seeks a contractor to construct an addition to an existing building to house a new emergency generator at the Ann Arbor VA Medical Center in Ann Arbor, Michigan. The Department of Veterans Affairs Veterans Health Administration VISN 10 is seeking construction services to build a new generator building addition, tie the generator into the existing fuel farm, install automatic transfer switches to provide backup power to the central chilled water plant, and integrate new distributed control and building management systems with the facility's existing Siemens controls platform. The contractor will have 540 days to complete the work and must acknowledge any amendments by February 14, 2023. Evaluation criteria will include technical qualifications, past performance, and price.
This opportunity is set aside for Service-Disabled Veteran-Owned Small Businesses. The primary NAICS code is 237110 and PSC code R499. The estimated value is between $1-5 million. The contractor must construct a new building addition located at the Ann Arbor VA Medical Center to house a new emergency generator with connections to the existing fuel farm. Automatic transfer switches will provide backup power for the central chilled water plant. Work must be completed within 540 days at the medical center located at Ann Arbor, Michigan.
Notice text
Contractor is to construct a new addition to Bldg 32, Energy Center, to house a new generator. Construction will include tying into the existing fuel farm to provide fuel for the new generator; providing and installing multiple ATS switches for the new standby power system that is designed to back-up the central chilled water plant; and installation of DDC controls that are to tie into and integrate with the facilities existing Siemens Design building management system. The contractor will receive a total of 540 days to complete the work.
Files
Show all 13
Notice history
| Notice | Type | Posted |
|---|---|---|
| Z1DA--Add Emergency Power to Chiller 506-21-110 | Award Notice | |
| This notice | Solicitation | |
| Y1DA--Add Emergency Power to Central Chiller Plant 506-21-110 | Pre-Solicitation |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| Y1DA--CON NRM 531-25-102 | Expand Emergency Room | Veterans Integrated Service Network 20 | Service-Disabled Veteran-Owned Small Business | |
| Y1DZ--replace chilled water pump at the boiler plant | Veterans Integrated Service Network 2 | Service-Disabled Veteran-Owned Small Business | |
| C222--657A5-24-108, FCA Replace Medium Voltage Feeder 3 and Transformers l MC FY27 NRM VISN Base DE | Veterans Integrated Service Network 15 | Service-Disabled Veteran-Owned Small Business | |
| Z1DA--550-20-121 Demo Old Boiler Plant B100 (CON) | Veterans Integrated Service Network 12 | Service-Disabled Veteran-Owned Small Business | |
| CON | Z1DA | replace or chillers | 580-23-105 | solicitation | Veterans Integrated Service Network 16 | Service-Disabled Veteran-Owned Small Business |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity