Y1DA--FY27 NRM - EHRM Base 573-27-702-DB EHRM Generator Upgrades Design-Build - Gainesville VAMC

Open Pre-Solicitation Posted

Solicitation number
36C77627Q0073
Agency
Responses due
Set-aside
No set-aside

Opportunity facts

Place of performance
Malcom Randall Vamc Gainesville, Florida 32608, United States

Notice details come from SAM.gov. Updated .

About this opportunity

The VA Office of Facilities Acquisition, Program Contracting Activity Center, is conducting sources sought market research to identify qualified design-build teams for an Emergency Power Generator Upgrade supporting Electronic Health Record Modernization at the Malcom Randall VA Medical Center in Gainesville, Florida, with capabilities statements due December 7, 2026 at 2:00 PM Eastern. No set-aside is designated, and the notice states it is not a solicitation and creates no obligation on the VA.

The contract requires turnkey design-build services, including architect-engineer design, site preparation, construction, permits, temporary emergency power, demolition, testing, commissioning, training, and documentation. The contractor must protect the existing Emergency Power Switchboard and maintain required hospital emergency power throughout construction, subject only to specifically approved planned switching windows. The replacement generator must be rated at not less than 2,000 kW with at least 10% unused capacity. The facility's existing 1,275 kW Generator #5 reportedly operates at approximately 85% load, which the contractor must independently verify. Planned EHRM infrastructure is estimated to add 150-200 kW of critical load, and the Hybrid OR project is estimated at 100 kW.

The construction magnitude is estimated between $5 million and $10 million, with a 730-calendar-day duration from Notice to Proceed. The VA plans a competitive, firm-fixed-price design-build solicitation for mid-January 2026. The NAICS code is 238210 with a $19.0 million size standard, and the PSC is Y1DA. Capabilities statements are limited to twelve single-spaced pages and must address company information, business size classification, statement of interest, a bonding capacity letter, and up to six relevant projects demonstrating design-build or medical construction experience. Shawn Tavernia is the point of contact at shawn.tavernia@va.gov. The notice names no incumbent and lists no industry day.

Notice text

SYNOPSIS:

INTRODUCTION:

This Sources Sought Notice is for market research and information purposes only at this time and shall not be construed as a solicitation or as an obligation on the part of the Department of Veterans Affairs (VA).

The VA Office of Facilities Acquisition (OFA), Program Contracting Activity Center (PCAC) is conducting market research to identify qualified sources capable of performing a Design-Build (DB) project. Services to include Architect and Engineering (DB A/E) design services, site preparation and DB Construction (DB C) services for the construction of Emergency Power Generator Upgrade for Electronic Health Record Modernization at the Malcom Randall VA Medical Center (VAMC) located in Gainesville, Florida.

PROJECT DESCRIPTION:

The Malcom Randall VA Medical Center (Gainesville VAMC) has a requirement to design and construct an Emergency Power Generator Upgrade to support Electronic Health Record Modernization (EHRM) at the Malcom Randall VA Medical Center.

This Design-Build Team (DBT) shall provide all design and construction services, investigations, labor, materials, equipment, supervision, transportation, permits, temporary emergency power, demolition, lawful disposal, site improvements, testing, commissioning, training, and documentation necessary to deliver a complete turnkey Emergency Power Generator Upgrade for EHRM at MRVAMC. The DBT shall evaluate existing conditions and deliver a code-compliant operational emergency power system while protecting the existing Emergency Power Switchboard and maintaining required hospital emergency power capability throughout construction, subject only to specifically approved planned switching windows.

The facility's existing 1,275 kW emergency generator (Generator #5) reportedly operates at approximately 85% load; the Contractor shall independently verify actual demand and operating conditions. Planned EHRM infrastructure is estimated to add 150-200 kW of critical load, including IDF/telecommunications closets and associated cooling; the Hybrid OR project is estimated to add approximately 100 kW of emergency loads. These figures are planning estimates, not verified design loads. The replacement generator shall be rated at not less than 2,000 kW and selected to provide at least 10% unused rated kW capacity after accounting for verified coincident operating demand, planned loads, and site derating.

The DBT shall provide a complete enclosed generator and all required fuel, exhaust, switchgear interface, ATS, distribution, monitoring, platform, site, and temporary emergency power work. Existing generator site boundaries are constrained; significant expansion to the north or south is not anticipated to be feasible. The DBT shall confirm the usable footprint and design a solution accordingly.

PROCUREMENT INFORMATION:

The proposed project will be a competitive, firm-fixed-price contract utilizing the design-build approach outlined in Revolutionary FAR Overhaul (RFO) 36.101-2, Use of two-phase design-build selection procedures. The results and analysis of the market research will finalize the determination of the procurement method. The type of socio-economic set-aside, if any, will depend upon the responses to this notice and any other information gathered during the market research process.

This project is planned for advertising in mid-January 2026. The Magnitude of Construction for this project is between $5,000.000.00 and $10,000,000.00. The North American Industry Classification System (NAICS) code 238210 (size standard $19.0 million) applies to this procurement. The duration of the project is currently estimated at 730 calendar days from the issuance of a Notice to Proceed. The services for this project will include providing all design and construction related services.

CAPABILITY STATEMENT:

Respondents shall provide a general capabilities statement to include the following information:

Section 1: Provide company name, DUNS number and Unique Entity Identifier (UEI), company address, Point-of-Contact name, phone number and email.

Section 2: Provide company business size based on NAICS code 238210. Also, provide business type (i.e., Large Business, Small Business, Service-Disabled Veteran Owned Small Business, Small Disadvantaged Business, Women-Owned Small Business, Hub Zone Small Business, etc.).

Section 3: Provide a statement of interest in the project.

Section 4: Provide the prime contractor s available bonding capacity in the form of a letter of intent from your bonding company with this submission. *Please ensure that the individual bonding capacity is in line with the VAPM Magnitude of Construction listed above.

Section 5: Provide the type of work your company has performed in the past in support of the same or similar requirement. This section is IMPORTANT as it will help to determine the type of socio-economic set-aside, if any. Please provide the following in your response:

Provide a maximum of three (3) projects completed within the last ten years (10) years in which the Offeror s design-build team has worked together on previous design-build contracts similar in size, magnitude, complexity, and scope to this project. Projects must demonstrate a respondent s design-build experience as a prime construction contractor directly responsible to the owner and managing multiple subcontractors. NOTE: If a prime contractor does not have Design-Build experience, they are permitted to provide up to three (3) relevant non-Design-Build projects that are completed in clinical, hospital or other medical related use space similar in size, magnitude, complexity, and scope to this project.

The designer for the team may also provide up to three (3) relevant projects that fall under the requested criteria for the project.

A maximum total of six (6) projects may be submitted between the D-B and design teams. *All submission requirements for these projects remain the same and are listed above.

Describe your Self-Performed** effort (as either a Prime or Subcontractor). Describe Self-Performed work in terms of dollar value and description. **Self-Performed means work performed by the offeror themselves, NOT work performed by another company for them for any of the project examples provided.

It is requested that interested contractors submit a response (electronic submission) of no more than twelve (12) single sided pages, single-spaced, 12-point font minimum that addresses the above information. This response must be submitted as a single application-generated (not scanned) PDF document that is less than or equal to 4MB in size. Please note that hard copies will not be accepted. Please also include a cover page, which includes, at a minimum: the company s name, address, Unique Entity Identifier (if available), socio-economic status, point-of-contact name, phone number, and e-mail address. Responses must include the Sources Sought number and project title in the subject line of their e-mail response. Submissions (responses) shall be submitted via email to the primary and secondary points of contact listed below by December 7, 2026, at 2:00 PM ET. No phone calls will be accepted.

The Capabilities Statement submitted in response to this Sources Sought shall not be considered to be a bid or proposal. This notice is for information and planning purposes only and is neither to be construed as a commitment by the Government nor will the Government pay for information solicited. No evaluation letters and/or results will be issued to the respondents. After completing its analyses, the Government will determine whether to limit competition among the small business categories listed above or proceed with full and open competition as other than small business.

At this time no solicitation exists; therefore, please do not request a copy of the solicitation. If a solicitation is released it will be synopsized in Contract Opportunities at https://sam.gov/. It is the potential offeror's responsibility to monitor this site for the release of any solicitation or synopsis.

Please respond to both points of contact.

Contracting Office Address:

Office of Facilities Acquisition (OFA) Program Contracting Activity Center (OFA PCAC)

6100 Oak Tree Blvd. Suite 490

Independence, OH 44131

Primary Point of Contact:

Shawn Tavernia

Contract Specialist

Shawn.Tavernia@va.gov

Files

File Type Posted
36C77627Q0073.docx DOCX document

Similar open opportunities

Opportunity Agency Set-aside Responses due
Y1DZ--673-901 Brooksville CBOC Renovation Minor Design-Build - Brooksville, FL Brooksville VA Clinic Brooksville, Florida 34613, United States · NAICS 236220 VA Technology Acquisition Center No set-aside
Y1DA--FY27 NRM - EHRM Base 509-22-701 - EHRM Infrastructure Upgrades - Downtown Division - Construction (VA-27-00011175) Charlie Norwood Vamc Downtown Division Augusta Georgia 30901 · NAICS 236220 VA Technology Acquisition Center No set-aside
5680--FY27 NRM (PROJ 573-24-110) BB - Expand Cardiology Service Gainesville, Florida 32608, United States · NAICS 236220 Veterans Integrated Service Network 8 Service-Disabled Veteran-Owned Small Business
Increase Emergency Power Rhode Island 02908, United States · NAICS 236220 Veterans Integrated Service Network 1 Service-Disabled Veteran-Owned Small Business
C222--589-27-108, Correct Electrical Deficiencies in Building 26 KCVA (ME) FY27 NRM VISN Base - AE (VA-27-00021035) 4801 Linwood Blvd Kansas City MO 64128 · NAICS 541330 Veterans Integrated Service Network 15 Service-Disabled Veteran-Owned Small Business