Y1AA--Infrastructure Deficiencies B408 [552-19-102] Dayton VAMC
Closed Solicitation Posted
This opportunity was awarded. See the award notice from , or the latest special notice from .
- Solicitation number
- 36C25025B0036Amend0010
- Agency
-
Veterans Integrated Service Network 10
Veterans Health Administration, Department of Veterans Affairs
- Responses due
- Set-aside
- Service-Disabled Veteran-Owned Small Business
Opportunity facts
- NAICS code
- 236220 Commercial and Institutional Building Construction
- PSC
- Y1AA Construction Of Office Buildings
- Place of performance
- Dayton, Ohio 45428, United States
- Points of contact
Notice details come from SAM.gov. Updated .
About this opportunity
The Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 10 is seeking construction services to correct infrastructure deficiencies in Building 408 at the Dayton Veterans Affairs Medical Center. This procurement focuses on installing aluminum windows manufactured by Graham Architectural Products (Graham 1200H Series, Manufacturing code 1227) along with associated interior finishes including paint, ceiling systems, flooring, and other materials. Amendment 0010 has been issued to publish Addendum 3, which provides updated technical specifications and drawings for the project, particularly revising window specifications and finish schedules. The solicitation maintains all previous terms and conditions while incorporating these technical updates for the infrastructure improvement project. The bid opening is scheduled for September 11, 2025, at 10:00 AM at the Network Contracting Office 10 located at 3140 Governor's Place Blvd, Suite 210, Kettering, OH 45429.
This opportunity is set aside for Service-Disabled Veteran-Owned Small Business enterprises under NAICS code 236220 for Commercial and Institutional Building Construction. The work will be performed at the Dayton VAMC facility in Dayton, Ohio 45428, with the project involving the installation of 11 different aluminum window types with varying dimensions ranging from 2' - 3" to 6' - 8" in width and 2' - 0" to 7' - 0" in height. The project also includes seven different door configurations and comprehensive interior finish work with specific materials such as Sherwin Williams paint colors, Armstrong acoustical ceiling systems, Johnsonite resilient base, and Interface carpet. The windows must meet specific performance criteria including load resistance, thermal transmittance, air infiltration resistance, and come with a 10-year manufacturer's warranty. The construction documents are dated August 2022, indicating this is a well-developed project ready for implementation.
Notice text
The purpose of this Amendment (0010) is to:
1. Publish Addendum 3 for the Correct Infrastructure Deficiencies B408 Project at Dayton VAMC.
All other terms and conditions remain unchanged.
***The bid opening date/time remains unchanged: September 11, 2025, at 10:00AM (Local). The location for the bid opening remains unchanged: Network Contracting Office 10, 3140 Governor's Place Blvd, Suite 210, Kettering, OH 45429.***
Files
| File | Type | Posted |
|---|---|---|
| 090600 - Schedule of Finishes.pdf | ||
| 552-19-102 Dayton VAMC Correct Infrastructures Deficiencies - AS602.pdf | ||
| 36C25025B0036 0010.docx | DOCX document | |
| 085113 - Aluminum Windows.pdf |
Notice history
Show all 15
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| C1DA--AE Replace Roofing 539-25-101 | Veterans Integrated Service Network 10 | Service-Disabled Veteran-Owned Small Business | |
| C1DA--AE Replace Roofing Cx - 539-25-101 | Veterans Integrated Service Network 10 | Service-Disabled Veteran-Owned Small Business |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity