WC100 Remote Condenser Install
Closed Solicitation Posted
This opportunity was awarded. See the award notice from .
- Solicitation number
- N4008525R9010
- Agency
-
Naval Facilities Engineering Command
Department of the Navy, Department of Defense
- Responses due
- Set-aside
- Total Small Business
Opportunity facts
- NAICS code
- 238220 Plumbing, Heating, and Air-Conditioning Contractors
- Place of performance
- Camp Lejeune, North Carolina 28547, United States
Notice details come from SAM.gov. Updated .
About this opportunity
The Department of the Navy Naval Facilities Engineering Command is soliciting proposals for the installation of a new remote condensing unit on the roof of building WC100 at Marine Corps Base Camp Lejeune to restore operation of Reefer Box (I). The project involves providing all materials, labor, equipment, and supervision to install a 460 Volt/3 Phase/60 Hertz remote condensing unit, including routing new refrigerant piping, electrical work, system evacuation and charging with R-404A refrigerant, and setting the box temperature to 35 degrees. Only pre-qualified Mechanical MACC (Multiple Award Construction Contract) contractors listed on the General Requirements cover page are eligible to submit proposals for this specialized refrigeration system installation. The contract will be awarded on a lowest price basis, with contractors required to maintain facility operations throughout the construction period and minimize disruption to normal activities. Following multiple amendments, the final proposal submission deadline is 1400 hours on July 31, 2025, with a mandatory site visit having been conducted on July 18, 2025.
This opportunity is designated as a Total Small Business set-aside, with only three specific mechanical contractors eligible to compete: Mechworks Mechanical Contractors, North State Mechanical, and R&W Construction Company. The project has an estimated value range between $25,000 and $100,000, reflecting the specialized nature of the refrigeration system installation work. The contract includes a 180-day completion timeline following award, with work to be performed at Marine Corps Base Camp Lejeune, North Carolina. Contractors must comply with Davis-Bacon wage rates for various labor classifications including pipefitters, electricians, and laborers, as well as Buy American construction material requirements. The project falls under NAICS code 238220 for Plumbing, Heating, and Air-Conditioning Contractors, and contractors must adhere to comprehensive environmental compliance requirements and safety protocols specific to the Marine Corps installation.
Notice text
Only Mechanical MACC Contractors listed on the General Requirements cover page may submit a proposal for this ROICC Camp Lejeune area of responsibility project. See attached documents for scope of work and any applicable drawings.
Files
Show all 11
Notice history
| Notice | Type | Posted |
|---|---|---|
| WC100 Remote Condenser Install | Award Notice | |
| This notice | Solicitation |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| Compressor unit, REF, in repair/modification of | Naval Supply Systems Command | No set-aside | |
| Troubleshoot & Repair of Portable Chillers Service Requirement | Air Education and Training Command | Total Small Business | |
| Air Compressor Relocation | Office of Naval Research | No set-aside | |
| IDIQ, JOC for plumbing, heating, air conditioning projects at marine corps logistics base barstow, marine corps air-ground combat center 29 palms, marine corps mountain warfare training center bridgeport, and naval air weapons station china lake, CA AOR | Naval Facilities Engineering Command | Total Small Business | |
| C1 condenser | Coast Guard | No set-aside |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity