Vindicator Security Upgrade
Closed Solicitation Posted
- Solicitation number
- FA489722Q0021
- Agency
-
Air Combat Command
Air Force, Department of Defense
- Responses due
- Set-aside
- Total Small Business
Opportunity facts
- NAICS code
- 561621 Security Systems Services (except Locksmiths)
- Place of performance
- Mountain Home AFB, Idaho 83648, United States
Notice details come from SAM.gov. Updated .
Notice text
2 versions
Update #2 · Latest ·
The 366th Fighter Wing primary Command Post, Crisis Action Team, and Emergency Operations Center located at 360 Gunfighter Avenue, Building 1501 on Mountain Home Air Force Base (MHAFB), have a requirement to control personnel access to these facilities. Additionally, all of these work centers are Restricted Areas, further evidencing the criticality of effective access control. Our current installed systems have reached the end of their service life and require replacement. The solution must upgrade existing Access Control System (ACS) door entry reader technology capable of reading commercially available 125 kHz cards, as well as magnetic switch door locks, emergency release buttons, remote entry unlock capability, and four (4) internally managed access configurations (see Appendice 4 - Layout plan (CP - Entry Control)).
The solution shall need to upgrade door sensors on all external doors and the internal doors utilizing ACS (nine (9) doors) shall provide an audible and visual alarm report to the Intrusion Detection System (IDS) for any alarms on the respective door. The solution shall need to interface with our existing Vindicator IDS and utilize one (1) administrative system to manage the IDS, ACS for user badges. The solution shall integrate with the Installation Base Defense Security System (IBDSS) in order to comply with IDS notifications as required by DoDM 5200.01 Volume 3, v3, Enclosure 3, para 3.b.3.b. (page 36), DoD Information Security Program: Protection of Classified Information. The solution installation shall minimize disruption and downtimes to the mission-critical operations conducted in these facilities and ensure the Restricted Area remains secure. Finally, the solution requires immediate service response and support, in the event of system failures or malfunctions.
RFQ Due Date: 23 September 2022
RFQ Due Time:11:00 AM MST
Question Due Date: 20 September 2022
Question Due Date: 16:30 AM MST
Site Visit: By Request Only
Update #1 ·
The 366th Fighter Wing (FW) primary Command Post, Crisis Action Team, and Emergency Operations Center located at 360 Gunfighter Avenue, Building 1501, have a requirement to control personnel access to these facilities. Additionally, all of these work centers are Restricted Areas, further evidencing the criticality of effective access control. The current installed system has reached the end of its service life and requires replacement. The new solutions must upgrade existing Access Control System (ACS) door entry reader technology capable of reading commercially available 125 kHz cards, as well as magnetic switch door locks, emergency release buttons, remote entry unlock capability, and four (4) internally managed access configurations. has a requirement to upgrade their Vindicator Security System in the main Command Post.
The solution should include internal and external high definition security cameras to replace the current system. The solution shall need to upgrade door sensors on all external doors and the internal doors utilizing ACS (nine (9) doors) shall provide an audible and visual alarm report to the Intrusion Detection System (IDS) and integrate with the applicable security cameras to provide Immediate Visual Assessment for any alarms on the respective door. The solution shall need to interface with our existing Vindicator IDS (V5 UHS 1401 v3.20) and utilize one (1) administrative system to manage the IDS, ACS for user badges and the closed circuit television (CCTV) system. The solution shall also provide and integrate a Video management System (VMS) with the Installation Base Defense Security System (IBDSS) in order to comply with IDS notifications as required by DoDM 5200.01 Volume 3, v3, Enclosure 3, para 3.b.3.b (page 36), DoD Information Security Program: Protection of Classified Information. The solution installation shall minimize disruption and downtimes to the mission-critical operations conducted in these facilities and ensure the Restricted Area remains secure.