Ventilator Full-Service Maintenance

Open Pre-Solicitation Posted

Solicitation number
IHS1532582
Agency
Responses due
Set-aside
Indian Small Business Economic Enterprise

Opportunity facts

Place of performance
Lawton, Oklahoma 73507, United States

Notice details come from SAM.gov. Updated .

About this opportunity

The Indian Health Service is seeking Indian Small Business Economic Enterprises (ISBEEs) to perform full-service maintenance for five government-owned Hamilton Medical T1 ventilators at Lawton Indian Hospital, with responses due November 27, 2026 at 1:00 PM CST. The set-aside is Indian Small Business Economic Enterprise under the Buy Indian Act, 25 U.S.C. 47, and this Sources Sought notice is market research, not a solicitation for proposals. Place of performance is Lawton Indian Hospital, 1515 NE Lawrie Tatum Rd, Lawton, OK 73507. The base year runs February 1, 2027 through January 31, 2028, with four optional 12-month extensions. Scope covers preventative maintenance, calibration, inspection, software and hardware upgrades, and corrective repair, including all labor, travel, parts, diagnostics, and technical support. Service engineers must be factory-trained and certified by Hamilton Medical. Requirements include one annual preventative maintenance inspection per ventilator within 30 calendar days of the annual due date, with electrical safety testing per NFPA 99; emergency response within 24 to 48 hours for critical failures and 3 to 5 business days for non-critical issues, with restoration within 72 hours of arrival; 100 percent authentic OEM replacement parts with a minimum one-year full replacement warranty; toll-free technical support Monday through Friday, 8:00 AM to 5:00 PM CST, with one-hour response; no-charge implementation of mandatory software, firmware, and safety updates; and itemized Field Service Reports within five business days of service completion. Responses must include a capability statement that directly demonstrates capability, experience, and ability to perform, plus the completed Buy Indian Act Indian Economic Enterprise Representation Form, SAM registration, UEI, CAGE Code, Tax ID, socioeconomic status, and GSA Schedule information. Generic capability statements are insufficient. Responses must exclude proprietary information, as the Government reserves rights to use non-proprietary technical information in any resultant solicitation. Other small businesses are also encouraged to respond. The notice cites NAICS 811210 with a $34.0 million size standard and PSC J065.

Notice text

Pursuant to 48 CFR Part 326, Subpart 326.603-3 and IHM 5.5-6, the Indian Health Service (IHS) must use the negotiation authority of the Buy Indian Act, 25 U.S.C. 47, to give preference to Indian Economic Enterprises (IEE) whenever the use of that authority is authorized and practicable. The Government is seeking to identify Indian Small Business Economic Enterprises (ISBEEs) capable of performing the below Indian Health Service (IHS) requirement for Ventilator Full-Service Maintenance Service. Any vendor responding to this notice should submit their capability statement as well as the Buy Indian Act Indian Economic Enterprise Representation Form (attached). Instructions for submission are outlined below. Indian Small Business Economic Enterprises (ISBEEs) and other small business are highly encouraged to respond to this notice. However, firms should understand that generic capability statements are not sufficient for effective evaluation of their capacity and capability to perform the work required. Responses must directly demonstrate the company's capability, experience, and ability to Provide comprehensive, full-service preventative maintenance, calibration, inspection, software/hardware upgrade, and corrective repair agreement for five (5) government-owned Hamilton Medical T1 ventilators for the Lawton Indian Hospital. The place of performance is Lawton Indian Hospital, 1515 NE Lawrie Tatum Rd, Lawton, OK 73507. Applicable NAICS Code: 811210 — Maintenance (small business size standard: $34.0 million). Product Service Code (PSC): J065.

Files

File Type Posted
Sources_Sought_IHS532582_2026-11-19.pdf PDF

Similar open opportunities

Opportunity Agency Set-aside Responses due
Full-service maintenance, inspection, calibration, and repair of a body plethysmograph system. Lawton, Oklahoma 73507, United States · NAICS 811210 Indian Health Service Indian Small Business Economic Enterprise
IHSSS11132026_HVAC/Refrigeration Parts, Equipment & Refrigerant Lawton, Oklahoma 73507, United States · NAICS 333415 Indian Health Service Buy Indian
HVAC Filters & Filtration Media Lawton, Oklahoma 73507, United States · NAICS 333413 Indian Health Service Buy Indian
HVAC Preventative Maintenance for Fort Hall Service Unit, Fort Hall, ID Fort Hall, Idaho 83203, United States · NAICS 238220 Indian Health Service No set-aside
Fire Monitoring, Inspections, Maintenance, and Remediation Services Oklahoma City, Oklahoma 73179, United States · NAICS 561621 Indian Health Service Indian Small Business Economic Enterprise

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity

GovTribe for Federal Contractors