Sources_Sought_IHS532582_2026-11-19.pdf

PDF 512 KB Posted

Attached to
Ventilator Full-Service Maintenance
Solicitation number
IHS1532582
Issued by

About this file

Sources Sought Notice and Performance Work Statement Summary

This is a Sources Sought Notice under the Buy Indian Act issued by the Indian Health Service (IHS) for Notice ID IHS532582, seeking Indian Small Business Economic Enterprises (ISBEEs) capable of providing comprehensive full-service maintenance for Hamilton Medical T1 ventilators at Lawton Indian Hospital in Lawton, Oklahoma. The notice is not a solicitation for proposals but rather a market research tool to identify qualified vendors. Responses are due by 1:00 PM CST on November 27, 2026, and must include company capability statements, socioeconomic status, SAM UEI number, CAGE Code, Tax ID, GSA Schedule information, and the completed Buy Indian Act Indian Economic Enterprise Representation Form. The applicable NAICS code is 811210 (Maintenance), with a small business size standard of $34.0 million, and the Product Service Code is J065. Respondents must be registered in SAM and should not include proprietary or confidential information in their responses, as the Government reserves rights to use non-proprietary technical information in any resultant solicitation.

The Performance Work Statement (PWS) establishes the detailed requirements for a comprehensive, full-service preventative maintenance, calibration, inspection, software/hardware upgrade, and corrective repair agreement for five (5) government-owned Hamilton Medical T1 transport ventilators. Key performance requirements include: (1) one comprehensive annual preventative maintenance inspection and certification per ventilator within ±30 calendar days of the annual due date, including physical checks, mandatory OEM overhaul kits, battery replacements, sensor calibration, and electrical safety testing per NFPA 99 standards; (2) emergency response within 24 to 48 hours for critical failures and 3 to 5 business days for non-critical issues with restoration to operational status within 72 hours of arrival; (3) 100 percent authentic OEM replacement parts with minimum one-year full replacement warranty; (4) toll-free technical telephone support Monday through Friday 8:00 AM to 5:00 PM CST with one-hour response time; and (5) implementation of all mandatory software, firmware, and safety updates at no additional charge. The contract period consists of a 12-month Base Year (February 1, 2027 to January 31, 2028) with four optional 12-month extensions. All service engineers must be factory-trained and certified by Hamilton Medical, and comprehensive documentation including itemized Field Service Reports must be submitted within five business days of service completion. The contract covers all labor, travel, parts, diagnostics, and technical support for five specific Hamilton Medical T1 ventilators identified by serial number.

View the file

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SOURCES SOUGHT NOTICE — BUY INDIAN ACT

Lawton Indian Hospital · Notice ID IHS532582

This is a Sources Sought notice. This is NOT a solicitation for proposals, proposal abstracts, or quotations.

Pursuant to 48 CFR Part 326, Subpart 326.603-3 and IHM 5.5-6, the Indian Health Service (IHS) must use the negotiation authority of the Buy Indian Act, 25 U.S.C. 47, to give preference to Indian Economic Enterprises (IEE) whenever the use of that authority is authorized and practicable.

The Government is seeking to identify Indian Small Business Economic Enterprises (ISBEEs) capable of performing the below Indian Health Service (IHS) requirement for Ventilator Full- Service Maintenance Service. Any vendor responding to this notice should submit their capability statement as well as the Buy Indian Act Indian Economic Enterprise Representation Form (attached). Instructions for submission are outlined below.

Indian Small Business Economic Enterprises (ISBEEs) and other small business are highly encouraged to respond to this notice. However, firms should understand that generic capability statements are not sufficient for effective evaluation of their capacity and capability to perform the work required. Responses must directly demonstrate the company's capability, experience, and ability to Provide comprehensive, full-service preventative maintenance, calibration, inspection, software/hardware upgrade, and corrective repair agreement for five (5) government-owned Hamilton Medical T1 ventilators for the Lawton Indian Hospital. The place of performance is Lawton Indian Hospital, 1515 NE Lawrie Tatum Rd, Lawton, OK 73507.

Applicable NAICS Code: 811210 — Maintenance (small business size standard: $34.0 million). Product Service Code (PSC): J065.

The Government requests interested parties submit a written response to this notice, which includes:

a. Company Name.

b. Company socioeconomic status.

c. Company System for Award Management (SAM) Unique Entity Identifier (UEI) number.

d. Company point of contact, mailing address, telephone number(s), and website address.

e. Name, telephone number, and e-mail address of a company point of contact who has the authority and knowledge to clarify responses with Government representatives.

f. CAGE Code.

g. Tax ID.

h. Date submitted.

i. Applicable company GSA Schedule number or other available procurement vehicle.

j. Company's System for Award Management (SAM) registration status. All respondents must register in SAM at https://www.sam.gov/.

k. Buy Indian Act Indian Economic Enterprise Representation Form (attached).

Disclaimer and Important Notes. This notice does not obligate the Government to award a contract. Any information provided by industry to the Government as a result of this sources sought synopsis is strictly voluntary. Responses will not be returned. No entitlements to payment of direct or indirect costs or charges to the Government will arise as a result of contractor submission of responses, or the Government's use of such information or otherwise pay for the information provided in response. The Government reserves the right to use information provided by respondents for any purpose deemed necessary and legally appropriate. Any organization responding to this notice should ensure that its response is complete and sufficiently detailed to allow the Government to determine the organization's qualifications to perform the work. Respondents are advised that the Government is under no obligation to acknowledge receipt of the information received or provide feedback to respondents with respect to any information submitted. After a review of the responses received, a pre-solicitation synopsis and solicitation may be published on a Government Point of Entry (GPE). However, responses to this notice will not be considered adequate responses to a solicitation.

Confidentiality. No proprietary, classified, confidential, or sensitive information should be included in your response. The Government reserves the right to use any non-proprietary technical information in any resultant solicitation(s).

How to respond: Please include the notice IHS532582 in the subject line. Responses must be submitted via email to the Contract Specialist, Jarrod Prince at jarrod.prince@ihs.gov no later than 1:00 PM CST on November 27, 2026.

Capability statements will not be returned and will not be accepted after the due date. The maximum number of pages for this submission is 5 pages.

Attachments:

1. Buy Indian Act Indian Economic Enterprise Representation Form

2. Performance Work Statement (PWS)

Department of Health and Human Services Indian Health Service

Performance Work Statement (PWS) Hamilton Medical T1 Ventilator Full- Service Maintenance Contract

Lawton Service Unit –11/17/2026

1. PURPOSE / BACKGROUND

The Indian Health Service (IHS), an operating division within the U.S. Department of Health and Human Services (HHS), is responsible for providing federal health services to American Indians and Alaska Natives. The mission of IHS is to raise the physical, mental, social, and spiritual health of American Indians and Alaska Natives to the highest level and assure that comprehensive, culturally acceptable personal and public health services are available and accessible to members of the 574 federally recognized Tribes across the United States.

The Lawton Service Unit (LSU) operates the Lawton Indian Hospital (LIH), a Joint Commission– accredited federal healthcare facility located in Lawton, Oklahoma. The mission of the Lawton Service Unit is to deliver quality care in order to attain positive health outcomes for all valued patients with emphasis on cultural sensitivity and human dignity.

To support critical care delivery and patient transport operations, the Respiratory Therapy Department and Emergency/Inpatient Services utilize Hamilton Medical T1 transport ventilators.

These mechanical ventilators represent essential life-support modalities required to deliver invasive and non-invasive respiratory support during emergency resuscitation, intensive care treatment, and inter-/intra-facility patient transport. LSU adheres strictly to National Fire Protection Association (NFPA) 99 Health Care Facilities Code standards, mandating a 100% on-time completion rate for all medical equipment preventative maintenance and safety testing.

The purpose of this Performance Work Statement (PWS) is to establish a comprehensive, full-service preventative maintenance, calibration, inspection, software/hardware upgrade, and corrective repair agreement for five (5) government-owned Hamilton Medical T1 ventilators. This PWS defines the required outcomes; except where specific manufacturer specifications or regulatory mandates apply, the methods used to achieve those outcomes are the responsibility of the Contractor.

2. SCOPE / REQUIRED OUTCOMES

The Contractor shall provide all necessary certified labor, factory-trained service engineers, original equipment manufacturer (OEM) replacement parts, diagnostic test fixtures, calibrated test instrumentation, certified preventative maintenance kits, travel, shipping, and technical support required to maintain five (5) Hamilton Medical T1 ventilators in optimal, reliable, and manufacturer-certified operating condition.

All preventative maintenance inspections, routine servicing, hardware/software modifications, and unscheduled corrective repairs shall strictly adhere to Hamilton Medical factory specifications, applicable Federal Acquisition Regulation (FAR) provisions, NFPA 99 healthcare facility requirements, and The Joint Commission accreditation standards.

Location of Service:

USPHS Lawton Indian Hospital Biomedical Engineering / Respiratory Therapy Department 1515 Lawrie Tatum Road Lawton, Oklahoma 73507

3. PERFORMANCE REQUIREMENTS AND STANDARDS

The Contractor’s performance will be evaluated against the following standards. (See Section 10 for the Quality Assurance / Surveillance Matrix.)

Required Service

(Outcome) Performance Standard

Acceptable Quality Level

(AQL)

Method of Surveillance

Complete 100% on-time completion (within ±30 calendar days of scheduled annual anniversary date); 100% compliance with OEM testing tolerances and NFPA 99 criteria.

comprehensive annual

3.1

Annual Scheduled Preventative Maintenance

(PM) &

Certification factory-level PM, replacement of manufacturer PM kits/batteries, sensor calibration, electrical safety inspection, and certification per

Detailed Field Service Report (FSR), completed PM checklist, and LSU Biomedical Engineering verification.

Hamilton Medical guidelines.

Required Service

(Outcome) Performance Standard

Acceptable Quality Level

(AQL)

Method of Surveillance

On-site response and

On-site technician arrival within 24 to 48 hours of service call notification;

complete restoration to clinical operational status within 72 hours of arrival.

LSU Biomedical service logs, Contractor work orders, and equipment acceptance sign-off.

diagnostic restoration Unscheduled for equipment failures,

3.2 Emergency &

Corrective operational errors, or component

Repairs malfunctions using genuine OEM replacement parts.

All replacement 100% authentic OEM parts; zero unauthorized or grey-market parts; minimum one-year (12-month) full replacement warranty on all installed parts and labor.

components, lithium-ion

3.3

OEM

Replacement Parts & Battery Warranty battery packs, flow sensors, sub-assemblies, and internal boards must be authentic, brand-new OEM parts

Itemized parts invoice review, packing slips, and work order audits.

manufactured by Hamilton Medical.

Toll-free telephone

Direct, priority access to support available

3.4

Technical Phone & Remote Support Assistance factory-certified technical specialists for troubleshooting, application support, diagnostic code evaluation, and

Monday through Friday, 8:00 AM

– 5:00 PM CST

(excluding Federal Holidays).

LSU trouble logs, call-in logs, and vendor teleconference records.

operational guidance. Response or callback time 1 hour.

Required Service

(Outcome) Performance Standard

Acceptable Quality Level

(AQL)

Method of Surveillance

Implementation of all 100% of applicable safety updates and software revisions installed during the contract year or next scheduled maintenance window.

mandatory and recommended software FSR

Software updates, firmware documentation,

3.5 Updates &

Hardware upgrades, and safety field modifications software revision verification, and

Enhancements issued by Hamilton engineering Medical to optimize bulletins.

equipment performance.

Comprehensive, 100% of reports LSU Biomedical Engineering document review and compliance check against Joint Commission standards.

itemized service reports submitted to

3.6 Service Documentation & Reporting

detailing inspection checklists, as-found/as-left electrical/calibration data, parts replaced, LSU Biomedical Engineering within five (5) business days and operational following service clearance. completion.

100%

3.7

Technician Qualifications & Factory Competency

All field service engineers performing on-site maintenance or repair must be factory-trained and certified on Hamilton Medical T1 systems.

compliance;

valid manufacturer training certifications maintained on file prior to entering the

Verification of technician credentials and training certificates.

facility.

4. CONTRACTOR RESPONSIBILITIES

4.1 Preventative Maintenance and Recertification

The Contractor shall perform one (1) comprehensive annual Preventative Maintenance (PM) inspection and certification visit per contract year for each covered ventilator, scheduled in coordination with LSU Biomedical Engineering within ±30 calendar days of the annual due date.

PM procedures must conform strictly to Hamilton Medical factory service manuals and shall include, at a minimum:

Comprehensive physical, structural, and pneumatic integrity checks (housing, display, mounts, O-rings, and gas inlets).

Mandatory installation of annual manufacturer preventative maintenance overhaul kits, including expiratory valves, internal filters, intake filters, micro-bacterial filters, and required seal replacements.

Internal backup battery and auxiliary lithium-ion battery capacity/health evaluations;

replacement of expiring or non-compliant batteries with OEM Hamilton Medical battery packs.

Calibration and functional verification of internal flow sensors, proximal flow sensors, pressure transducers, integrated turbine blowers, and oxygen blending/monitoring systems.

Electrical safety testing in strict accordance with NFPA 99 standards (chassis leakage current, ground wire resistance, and line voltage safety).

Diagnostic software execution, alarm limit validation, apnea backup ventilation testing, and operational run-in testing.

Affixing a visible, durable, and legible inspection label indicating the service date, next PM due date, technician name/signature, and pass/fail certification status.

4.2 Unscheduled and Corrective Repairs

Tier 1 — Critical / Emergency Failure: Any failure, pneumatic breakdown, turbine malfunction, power/alarm fault, or electronic failure that renders a ventilator clinically inoperable or compromises patient safety. Upon notification by LSU Biomedical Engineering or the Contracting Officer's Representative (COR), the Contractor must respond on-site within 24 to 48 hours.

Tier 2 — Non-Critical / Minor Service: Defined as an auxiliary issue, minor cosmetic/peripheral defect, non-critical accessory malfunction, or secondary fault where the ventilator has backup redundancies or remains safe for clinical standby. The Contractor shall coordinate and respond on-site within three (3) to five (5) business days.

Comprehensive Coverage: The contract coverage includes all costs associated with certified technician travel, round-trip mileage, diagnostic bench time, on-site labor, and freight/shipping of parts.

Prior Authorization: Any service or repair determined to fall outside the standard scope of this agreement (e.g., damage caused by gross operator abuse or external physical catastrophe) must be submitted in writing to the LSU Biomedical Equipment Technician and the Contracting Officer (CO) before billable work or non-contract costs are incurred.

4.3 Replacement Parts and Warranty

The Contractor shall maintain immediate access to genuine Hamilton Medical OEM replacement parts, turbine modules, electronic boards, valves, and hardware. Rebuilt, used, cloned, or unauthorized third-party components are strictly prohibited without prior written authorization from the Contracting Officer and Biomedical Engineering.

Warranty: All parts installed under this contract shall carry a minimum of a one (1) year (12-month) full replacement warranty, effective from the date of final Government acceptance.

4.4 Technical Telephone and Remote Troubleshooting Support

The Contractor shall provide toll-free telephone support and certified technical application support to assist LSU biomedical technicians and clinical personnel with real-time troubleshooting, code identification, and diagnostic resolution.

Hours of Availability: Monday through Friday, 8:00 AM to 5:00 PM CST, excluding Federal Holidays. Initial telephone response time shall not exceed one (1) hour.

4.5 Hardware and Software Updates

The Contractor shall track and install all software updates, firmware upgrades, and manufacturer-released technical bulletins designed to improve system performance, address clinical cybersecurity patches, or enhance Hamilton T1 ventilator functionality at no additional charge to the Government.

5. LEVEL OF EFFORT AND EQUIPMENT INVENTORY

The equipment covered under this agreement is operated by the Lawton Indian Hospital (LSU) and maintained in coordination with the Biomedical Engineering Department:

Item

Equipment Description Manufacturer Model

Serial Number

Department / Location

Coverage Level

001 Transport Ventilator

Hamilton Medical

T1 11370

USPHS

Lawton Indian Hospital

Full Comprehensive Service (Annual PM, Corrective Repairs, OEM Parts, Batteries, Labor, Travel, Updates)

002 Transport Ventilator

Hamilton Medical

T1 18357

USPHS

Lawton Indian Hospital

Full Comprehensive Service (Annual PM, Corrective Repairs, OEM Parts, Batteries, Labor, Travel, Updates)

003 Transport Ventilator

Hamilton Medical

T1 19040

USPHS

Lawton Indian Hospital

Full Comprehensive Service (Annual PM, Corrective Repairs, OEM Parts, Batteries, Labor, Travel, Updates)

004 Transport Ventilator

Hamilton Medical

T1 18386

USPHS

Lawton Indian Hospital

Full Comprehensive Service (Annual PM, Corrective Repairs, OEM Parts, Batteries, Labor, Travel, Updates)

Item

Equipment Description Manufacturer Model

Serial Number

Department / Location

Coverage Level

005 Transport Ventilator

Hamilton Medical

T1 18385

USPHS

Lawton Indian Hospital

Full Comprehensive Service (Annual PM, Corrective Repairs, OEM Parts, Batteries, Labor, Travel, Updates)

6. PERIOD OF PERFORMANCE

The period of performance shall consist of a twelve (12) month Base Year with four (4) consecutive twelve (12) month Option Years, exercised solely at the discretion of the Government:

Base Year: February 01, 2027 to January 31, 2028 Option Year 1: February 01, 2028 to January 31, 2029 Option Year 2: February 01, 2029 to January 31, 2030 Option Year 3: February 01, 2030 to January 31, 2031 Option Year 4: February 01, 2031 to January 31, 2032

7. SPECIAL REQUIREMENTS

7.1 Facility Coordination & Biomedical Notification

The Contractor’s field engineer must contact and notify the Lawton Indian Hospital Biomedical Engineering Department at least forty-eight (48) hours prior to arriving on-site for scheduled maintenance.

Upon arrival at the facility, the technician must check in at the Main Security Desk, present valid identification, obtain a vendor badge, and report immediately to Biomedical Engineering prior to touching any clinical equipment. The technician must sign in and out at each entry/exit.

Deliveries and maintenance visits must occur during normal working hours; deliveries and technician check-ins will not be accepted after 4:15 PM CST.

7.2 Smoke- and Tobacco-Free Environment

The USPHS Lawton Service Unit campus (including all buildings, parking structures, vehicles, sidewalks, and federal grounds) is 100% smoke-free and tobacco-free. The use of tobacco products, electronic cigarettes, and vaporizers is strictly prohibited. Violators will be removed from federal property.

7.3 Security, Badging, and Safety Regulations

In accordance with HHSAR 304.1300(b), non-routine contractor personnel shall comply with OPDIV DHHS/SE Region – Human Resources, Security Clearance Guidance – Visitors policy for the duration of contract performance.

Contractor personnel must carry a valid government-issued photo ID (driver’s license or passport) at all times.

Contractor employees shall comply with all LSU Environment of Care, life safety, infection control, and hazardous materials guidelines. Escorts will be provided when accessing secure or patient-care areas.

7.4 Confidentiality, Privacy, and Information Security

The Contractor and all assigned personnel shall maintain strict confidentiality regarding hospital operations and comply with the Health Insurance Portability and Accountability Act (HIPAA) of 1996 and the Privacy Act of 1974.

Contractor personnel shall not view, copy, record, disclose, or disseminate any patient health information (PHI) or sensitive operational data.

All public or media inquiries, legal matters, or disputes must be immediately referred to the Contracting Officer and the Government Designated Representative.

7.5 Personnel Qualifications & Competency

All personnel performing services under this contract shall be factory-trained, certified, and fully qualified by Hamilton Medical to maintain and overhaul Hamilton T1 ventilator systems. Documentation verifying active factory certifications must be submitted to the Contracting Officer and Biomedical Engineering prior to contract performance.

8. DELIVERABLES AND REPORTING REQUIREMENTS

8.1 Itemized Field Service Reports (FSR)

Following every scheduled PM, unscheduled corrective repair, calibration, or software update visit, the Contractor must complete and provide a comprehensive Field Service

Report and completed PM checklist.

Submission Deadline: The report must be submitted electronically or delivered in person to the LSU Biomedical Engineering Department within five (5) business days of service completion.

Required Documentation Content:

Date, arrival time, departure time, and total labor hours.

Equipment model, serial number, and facility asset tracking number.

Specific description of customer complaint or scheduled maintenance scope.

Itemized listing of all tests, adjustments, and calibrations performed.

As-found and as-left performance values, pressure tests, and electrical safety data (NFPA 99 parameters).

Itemized record of all OEM replacement parts installed, including part descriptions, part numbers, serial/lot numbers, and battery expiration dates.

Final certification statement confirming the ventilator meets all Hamilton Medical operating tolerances and is cleared for clinical use.

Field service engineer signature and LSU Biomedical Technician acceptance signature.

8.2 Invoicing and Warranty Records

Invoices must be submitted electronically through the designated federal payment system (IPP) in accordance with contract terms.

Invoices must clearly cite the contract number, purchase order number, covered unit serial numbers, and be accompanied by approved service reports and warranty statements.

8.3 Contractor Point of Contact (POC)

The Contractor shall designate a single, dedicated Point of Contact (POC) and an alternate empowered to make operational and technical decisions.

The Contractor shall furnish a toll-free customer support number accessible during standard working hours (8:00 AM – 5:00 PM CST, Monday through Friday).

9. CONTRACT ADMINISTRATION & GOVERNMENT FURNISHED RESOURCES

9.1 Government Points of Contact

Biomedical Engineering Point of Contact:

Biomedical Equipment Support Specialist USPHS Lawton Indian Hospital 1515 Lawrie Tatum Rd, Lawton, OK 73507

Clinical Department Representative:

Respiratory Therapy Supervisor / Department Director USPHS Lawton Indian Hospital 1515 Lawrie Tatum Rd, Lawton, OK 73507 Contracting Officer’s Representative (COR):

Facilities Engineer / Designated COR USPHS Lawton Indian Hospital 1515 Lawrie Tatum Rd, Lawton, OK 73507 Contracting Officer (CO):

Division of Acquisition Management Indian Health Service

9.2 Government-Furnished Property, Facilities, and Services

In accordance with FAR Part 52.245-1, the Government shall provide:

Reasonable physical access to the five (5) Hamilton Medical T1 ventilators within a safe, climate-controlled hospital working environment.

Standard commercial electrical power (120V AC), medical gas outlets (O2 / medical air where available for testing), and lighting necessary to execute servicing.

Government-furnished facilities, utilities, and equipment are provided strictly for the execution of services required under this contract.

9.3 Contractor-Furnished Property, Tools, and Materials

The Contractor shall furnish all tools, diagnostic test sets, calibrated flow/volume/pressure analyzers, electrical safety analyzers, laptop computers, proprietary service software/cables, factory calibration fixtures, OEM preventative maintenance kits, and genuine Hamilton Medical replacement batteries required to perform all work under this contract.

All test instruments used by the Contractor must maintain active calibration traceable to the National Institute of Standards and Technology (NIST).

9.4 Changes to the Performance Work Statement

Any changes, additions, deletions, or scope modifications to this PWS shall be authorized and executed exclusively through written formal modification issued by the Contracting Officer. Costs incurred by the Contractor based on directions from any person other than the Contracting Officer shall be borne entirely by the Contractor.

10. QUALITY ASSURANCE / SURVEILLANCE & PERFORMANCE MATRIX

The following surveillance checklist shall be utilized by the Government at the conclusion of each maintenance cycle, repair visit, or billing period to evaluate and document Contractor performance. The completed matrix will be retained within the official COR contract administration file.

# Performance Objective PWS Ref.

Standard & AQL Met?

10.1

Were all scheduled preventative maintenance overhauls and NFPA 99 safety inspections completed within the required window (±30 calendar days of due date) per Hamilton Medical specifications?

Sec.

3.1 & 4.1

[ ] Yes No

10.2 Did the Contractor respond on-site within 24 to 48 hours for all unscheduled/emergency corrective repair calls?

Sec.

3.2 & 4.2

[ ] Yes No

10.3 Were 100% of all installed replacement components, overhaul kits, and batteries authentic, brand-new Hamilton OEM parts backed by a 1-year warranty?

Sec.

3.3 & 4.3

[ ] Yes No

10.4 Was toll-free technical telephone support operational and answered/returned within one (1) hour during business hours (8:00 AM – 5:00 PM CST)?

Sec.

3.4 & 4.4

[ ] Yes No

10.5 Were all manufacturer-issued software, firmware, and safety enhancements installed in a timely manner?

Sec.

3.5 & 4.5

[ ] Yes No

10.6 Did the service engineer coordinate with Biomedical Engineering, sign in/out at Security, obtain vendor badging, and adhere to tobacco-free and hospital safety rules?

Sec.

7.1 – 7.3

[ ] Yes No

10.7 Were comprehensive, itemized Field Service Reports and PM checklists submitted to Biomedical Engineering within five (5) business days of service?

Sec.

3.6 & 8.1

[ ] Yes No

10.8 Did all service engineers possess verified, active Hamilton Medical factory training certifications prior to servicing units?

Sec.

3.7 & 7.5

[ ] Yes No

Overall Performance Rating: [ ] Acceptable [ ] Unacceptable

Department Supervisor Signature Date

Clinical / Department Director Signature Date

Rona S. Rupe -S Digitally signed by Rona S. Rupe -S Date: 2026.11.18 12:21:00 -06'00'

Rona S. Rupe -S Digitally signed by Rona S. Rupe -S Date: 2026.11.18 12:21:28 -06'00'

DEPARTMENT OF HEALTH & HUMAN SERVICES

Office of Management Services Division of Acquisition Policy (DAP)

5600 Fishers Lane Rockville, MD 20857

INDIAN HEALTH SERVICE

BUY INDIAN ACT

INDIAN ECONOMIC ENTERPRISE

REPRESENTATION FORM

SOLICITATION/SOURCES SOUGHT/RFI #: _________________________________________________

PROJECT TITLE: ________________________________________________________

DATE: ___________________________________________________________________

In accordance with 25 U.S.C. 47 the Buy Indian Act, the signature below constitutes self-certification that the Offeror meets the definition of an “Indian Economic Enterprise” (HHSAR 326.601) in response to this Sources Sought Notice, Request for Information (RFI) or Solicitation and resultant contract.

The enterprise must meet the definition of “Indian Economic Enterprise” throughout the following time periods:

(1) At the time an offer is made in response to this solicitation;

(2) At the time of contract award; and

(3) During the full term of the contract performance period. At any point during these periods, if the Contractor no longer meets the eligibility requirements, the contractor must provide immediate written notification to the Contracting Officer.

Individual Contracting Officers may require documentation of eligibility before awarding a set-aside or sole source contracts under the Buy Indian Act and awards may be subject to protest if the eligibility of the successful Offeror is in question. In addition to the self-certification requirements, successful Offerors must also be registered with the System of Award Management (SAM).

Any false or misleading information submitted by an enterprise when submitting an offer in consideration of an award set-aside under the authority of the Buy Indian Act is a violation of the law and punishable under 18 U.S.C. 1001.

False claims submitted as part of contract performance are subject to the penalties enumerated in 31 U.S.C. 3729 to 3731 and 18 U.S.C. 287.

REPRESENTATION

The Offeror represents as part of its offer that it does _____, does not _____ meet the definition of an “Indian Economic Enterprise” with “Indian Ownership” under the authority of the Buy Indian Act.

Name of the 51% owner of IEE Firm

Certifying Signature

Print Name

Name of Federally Recognized Tribal Entity

Business Name

UEI Number

Sources Sought Notice — Buy Indian Act

SOLICITATION_NUMBER: IHS1532582
PROJECT_TITLE: Hamilton Medical T1 Ventilators Service Agreement
DATE:
Does: Off
DoesNot: 0
NameOfTribalEntity:
BusinessName:
DUNSnumber:
OwnerName:
PrintName:

File details come from the government source that posted it. Updated .