Small Composite Cleanroom Modification

Closed Pre-Solicitation Posted

This opportunity was awarded. See the award notice from , or the latest solicitation from .

Solicitation number
SERV-C25-007
Agency
Responses due
Set-aside
Total Small Business

Opportunity facts

Place of performance
Tinker AFB, Oklahoma, United States

Notice details come from SAM.gov. Updated .

About this opportunity

The Department of the Air Force Materiel Command Air Force Sustainment Center is seeking qualified contractors to furnish and install an Environmental Control Air Handling Unit and associated cleanroom modification services at Tinker Air Force Base. The project involves installing a 25KW chilled water air handling unit with integrated controls and monitoring capabilities, an overhead ducted system with six diffusers, a high-speed fabric roll-up door, vacuum and compressed air ports, an eyewash station, and BACnet monitoring devices to track temperature, pressure, humidity, and particle count. The contractor must provide all labor, tools, equipment, materials, quality control, transportation, and inspection necessary to complete the upgrade to the Small Composite Cleanroom, while ensuring all services and components comply with Original Equipment Manufacturer specifications and relevant standards. While specific evaluation criteria are not detailed in this pre-solicitation notice, contractors should anticipate standard federal procurement evaluation practices for similar maintenance and repair projects. The Request for Quote is expected to post shortly after this notice, with a due date of April 14, 2026, and interested parties should monitor for the formal RFQ to submit their responses.

This opportunity is designated as a Total Small Business set-aside, restricting participation to firms meeting the Small Business Administration's size standards for the applicable NAICS code 238220 (Plumbing, Heating, and Air-Conditioning Contractors). No incumbent contractor or current award value is identified in this pre-solicitation notice. The project's specific scope includes installation of a unit measuring 54 inches wide by 31 inches deep by 74 inches high, featuring a 15KW electric reheat, 10 lb/hr steam humidifier, MERV 8 filters, and a 1-inch three-way modulating chilled water valve, along with associated infrastructure requiring integration with Tinker AFB's existing network and power systems. The Air Force will provide 460-volt, three-phase power supply connections within 25 feet for both the air handling unit and the high-speed door system. Contractors should prepare their qualifications and capabilities documentation to respond promptly when the formal RFQ is released, as this pre-solicitation notice serves as the official announcement period preceding formal solicitation.

Notice text

** THIS IS A PRE-SOLICITATION NOTICE. NO QUOTES WILL BE ACCEPTED UNTIL THE REQUEST FOR QUOTE (RFQ) IS POSTED. **

Description of Services: The 76th CMXG request services to furnish and install an Environmental Control Air Handling Unit to be mounted on the floor outside and adjacent to the room. This unit is 54” wide x 31” deep x 74” high. It is a chilled water up flow, 25KW 3-phase, 460v unit that will include chilled water coil, belt drive blower, humidifier, reheat, filters, with controls and monitoring to integrate with Tinker AFB’s network.

  • It will include a 15KW electric reheat, 1”, 3-way modulating chilled water valve, 1”, temperature/humidity sensor mounted on the unit, bottom return air, MERV 8 filters, 10 lb/hr steam humidifier, floor stand, and condensate probe.
  • Furnish and install overhead ducted system with 6 diffusers
  • Furnish and install low sidewall return
  • Furnish and install one 10’ x 8’ high-speed, fabric, roll up door along 40’ side of room
  • Furnish and install four process vacuum ports – TAFB to provide connection within 25’
  • Furnish and install two central vacuum ports – TAFB to provide connection within 25’
  • Furnish and install four compressed air ports – TAFB to provide connection within 25’
  • Furnish and install one drainless eye wash station
  • Furnish and install BACnet devices and monitoring system to track room temperature,
  • pressure, humidity, and particle count - TAFB to connect data collection equipment to
  • network.
  • Tinker Air Force Base (TAFB) to provide 460 v/3-phase power supply within 25’ for:
    • AHU – 25kw, 3ph, 480 volt
    • Door – 480 volt, 3 ph, 20 amp circuit

The Contractor shall provide all labor, tools, equipment, test equipment, material, parts, quality control, transportation and inspection manuals necessary to perform the upgrade to the Small Composite Cleanroom located on TAFB.

The Contractor shall be responsible for ensuring all services, parts and Original Equipment Manufacturer (OEM) components provided are in accordance with (IAW) the terms and conditions outlined herein, conform to the manufacturer’s equipment specifications and the Performance Work Statement (PWS).

Contemplated Contract Details:

  • Firm-fixed price (FFP)
  • 100% Small Business Set-Aside, Competitive
  • NAICS – 238220; Size Standard – $19M; FSC/PSC – J041

Eligibility for Award:

  1. System for Award Management (SAM) is required to receive any award. Vendors can register electronically at https://sam.gov/content/home.
  2. NIST SP 800-171 DoD Assessment: In order to be considered for award, if the Offeror is required to implement NIST SP 800–171, the Offeror shall have a current assessment ( i.e., not more than 3 years old unless a lesser time is specified in the solicitation) (see 252.204–7020) for each covered contractor information system that is relevant to the offer, contract, task order, or delivery order. The Basic, Medium, and High NIST SP 800–171 DoD Assessments are described in the NIST SP 800–171 DoD Assessment Methodology located at https://www.acq.osd.mil/asda/dpc/cp/cyber/docs/safeguarding/NIST-SP-800-171-Assessment-Methodology-Version-1.2.1-6.24.2020.pdf. In pursuant to DFARS 252.204-7019, the summary level score of 110 is expected.

Notice history

Notice Type Posted
Small Composite Cleanroom Modification Award Award Notice
Small Composite Cleanroom Modification Latest solicitation Solicitation
This notice Pre-Solicitation
Sources Sought Serv C25-007 Small Composite Cleanroom Modification Original Pre-Solicitation

Similar open opportunities

Opportunity Agency Set-aside Responses due
WWYK250063 - install react VII facility, B9001, post V19 Tinker AFB, Oklahoma 73145, United States · NAICS 236220 Air Force Sustainment Center Woman-Owned Small Business
Environmental control NAICS 333415 Construction and Equipment Total Small Business
Nitrogen Piping Replacement for Plasma Spray Booth Tinker AFB, Oklahoma 73145, United States · NAICS 811310 Air Force Sustainment Center Total Small Business
Repair Mechanical Systems IDIQ (FY 27-32) Wright Patterson Afb, OH 45433 United States 45433 · NAICS 238220 AFLCMC Wright Patterson AFB No set-aside
WPAFB 3rd Air Stream/ B18 Wright Patterson AFB, Ohio, United States · NAICS 238220 ENDIST Louisville No set-aside

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity