Repair HVAC System & Controls, Building J00567 on McChord Field, Joint Base Lewis-McChord (JBLM), WA. Chord (JBLM), WA.

Closed Solicitation Posted

This opportunity was awarded. See the award notice from .

Solicitation number
W912DW25BA012
Agency
Responses due
Set-aside
Total Small Business

Opportunity facts

Place of performance
McChord AFB, Washington 98438, United States

Notice details come from SAM.gov. Updated .

About this opportunity

The U.S. Army Corps of Engineers Seattle District is seeking a firm-fixed-price contractor to repair and replace the HVAC system and Direct Digital Controls (DDC) for Building J00567, a three-story Air Force dormitory on McChord Field at Joint Base Lewis-McChord, Washington. The project requires comprehensive demolition and replacement of existing HVAC and steam systems, installation of new HVAC units and ductwork, implementation of a BACnet-based DDC system with Java Application Control Engine (JACE) controllers, and installation of fiber optic lines and network infrastructure to support the Enterprise Energy Data Reporting System (EEDRS). Critical requirements include phasing work in 25% sections to maintain conditioned space for occupants during construction, ensuring compatibility with existing Tridium Niagara N4 framework systems, and compliance with JBLM and Unified Facilities Criteria standards. The solicitation underwent two amendments that updated the Statement of Work, Davis Bacon wage determinations, specifications, and extended the bid due date to September 18, 2025 at 1:00 PM local time. The evaluation will be based on sealed bid procedures for this Invitation for Bids solicitation.

This opportunity is designated as a 100% Total Small Business Set-Aside with a small business size standard of $45 million, and five contractors submitted bids ranging from approximately $6.8 million to $8.7 million total, with the government estimate at $7,046,000. The contract performance period is 425 calendar days from award, with liquidated damages of $1,572.70 per calendar day for delays and restricted work hours from 7:30 AM to 4:30 PM, Monday through Friday excluding federal holidays. The project is divided into three Contract Line Item Numbers (CLINs): HVAC system repair, DDC repair, and fiber optic line/data switch installation for energy monitoring systems. Brand name justifications were included for Tridium Niagara-compatible DDC systems and Juniper EX2300-Series data switches to ensure compatibility with existing base infrastructure. Work will be performed at Joint Base Lewis-McChord in Washington, with the contractor required to begin performance within 10 calendar days of contract award.

Notice text

3 versions

Update #3 · Latest ·

*****Amendment 0002 to Invitation for Bids (IFB) No. W912DW25BA012 for project titled, "Replace HVAC System & Controls, Building J00567," on Joint Base Lewis-McChord, WA, is hereby issued to accomplish the following: (a) Incorporate Section 00 00 00 - Procurement and Contracting Requirements. Section 00 00 00 revises the bid due date from 10:00 AM local time on 16 SEP 2025 TO 1:00 PM local time on 18 SEP 2025. (b) Incorporate a revised SF1442, which replaces and supersedes the SF1442 issued with the original solicitation. The revised SF1442 reflects the new bid due date of 1:00 PM local time on 18 SEP 2025. Bidders shall use the revised SF1442 issued with this amendment when submitting their bids. (c) Replace in its entirety Section 00 10 00 - Table of Contents issued under Amendment 0001 with the enclosed, revised Section 00 10 00 - Table of Contents. This revised Table of Contents reflects the incorporation of a revised SF1442, the incorporation of a revised Statement of Work, and the incorporation of an updated Davis Bacon Wage Determination. Changes are indicated in blue font. (d) Replace in its entirety the Statement of Work dated August 27, 2025, issued under Amendment 0001 with the enclosed, revised Statement of Work dated September 11, 2025. This revised Statement of Work incorporates paragraph 1.4.1.1.a.3 and its associated subparagraph, incorporates paragraph 1.4.1.1.e.3, incorporates paragraph 1.4.1.1.i and its associated subparagraphs, incorporates paragraph 1.4.1.2.b.5, incorporates paragraph 1.4.1.3.e.1.d, incorporates paragraph 8.1.1.4 and its associated subparagraph, and incorporates paragraph 8.8.3.4. Revisions to the Statement of Work are indicated in blue font. (e) Replace in its entirety the Davis Bacon Wage Determination issued under Amendment 0001 titled "(c) CE0965_00 73 00_Davis Bacon Wage Det_WA20250111_Mod10_29AUG25" with the current Davis Bacon Wage Determination "(c) CE0965_00 73 00_Davis Bacon Wage Det_WA20250111_Mod12_12SEP25". (f) All other terms and conditions under this solicitation remain unchanged.*****END AMENDMENT 0002*****Amendment 0001 to Invitation for Bids (IFB) No. W912DW25BA012 for project titled, "Replace HVAC System & Controls, Building J00567," on Joint Base Lewis-McChord, WA, is hereby issued to accomplish the following: (a) Replace in its entirety Section 00 10 00 - Table of Contents from the original solicitation with the enclosed, revised Section 00 10 00 - Table of Contents. This revised Table of Contents reflects the incorporation of a revised Statement of Work, the incorporation of an updated Davis Bacon Wage Determination, the incorporation of a revised specifications package, and the incorporation of a Mechanical As Builts package for bidder information purposes. (b) Replace in its entirety the Statement of Work dated August 8, 2025 from the original solicitation with the enclosed, revised Statement of Work dated August 27, 2025. This revised Statement of Work incorporates paragraph 1.3.2.2, incorporates paragraph 1.4.1.1.h, reflects the addition of mechanical asbuilts in the table at paragraph 3.2.1, revises the language and deletes the table at paragraph 4.2.1 to prevent inconsistences with the Table of Contents in the specifications package, and incorporates paragraph 8.12.5. Revisions to the Statement of Work are highlighted in red font. (c) Replace in its entirety the Davis Bacon Wage Determination from the original solicitation titled "(c)_CE0965_00 73 00_Davis Bacon Wage Det_WA20250111_Mod8_15AUG25" with the current Davis Bacon Wage Determination "(c)_CE0965_00 73 00_Davis Bacon Wage Det_WA20250111_Mod10_29AUG25". (d) Replace in its entirety the specifications package from the original solicitation titled "(e) CE0965_BJ00567_Specs1" with a revised specifications package titled "(e) CE0965_BJ00567_Specs1_Rev1_25AUG25." This revised specifications package addresses inconsistencies found in the Specifications Table of Contents and adds clarifying language on page three of the Specifications Table of Contents. (e) Provide a Mechanical As Builts package titled "CE0965_Mechanical As Builts" for bidder information purposes. (f) Provide the site visit sign-in sheet from the site visit which was conducted on 25 August 2025.*****

Invitation for Bids for an anticipated firm-fixed-price (FFP) contract to repair the HVAC and Direct Digital Controls (DDC) for Building J00567 on McChord Field, Joint Base Lewis-McChord (JBLM), WA. The project will deliver a fully functional, energy-efficient HVAC system with integrated DDC and network connectivity, supporting remote monitoring and compliance with JBLM and Unified Facilities Criteria (UFC) standards. The contractor shall provide all labor, materials, equipment, and supervision necessary to: (1) demolish and replace the existing HVAC and steam systems in accordance with the construction documents; (2) phase work in 25% sections to maintain conditioned space and facilitate occupant relocation during construction; (3) install new HVAC units, ductwork, and perform testing and balancing to verify performance; (4) implement a BACnet-based DDC system with Java Application Control Engine (JACE) controllers connected to the JBLM network; and (5) install a fiber optic line, network switch, and uninterrupted power supply to support the Enterprise Energy Data Reporting System (EEDRS), including NEMA-rated components where required.

Update #2 ·

*****Amendment 0001 to Invitation for Bids (IFB) No. W912DW25BA012 for project titled, "Replace HVAC System & Controls, Building J00567," on Joint Base Lewis-McChord, WA, is hereby issued to accomplish the following: (a) Replace in its entirety Section 00 10 00 - Table of Contents from the original solicitation with the enclosed, revised Section 00 10 00 - Table of Contents. This revised Table of Contents reflects the incorporation of a revised Statement of Work, the incorporation of an updated Davis Bacon Wage Determination, the incorporation of a revised specifications package, and the incorporation of a Mechanical As Builts package for bidder information purposes. (b) Replace in its entirety the Statement of Work dated August 8, 2025 from the original solicitation with the enclosed, revised Statement of Work dated August 27, 2025. This revised Statement of Work incorporates paragraph 1.3.2.2, incorporates paragraph 1.4.1.1.h, reflects the addition of mechanical asbuilts in the table at paragraph 3.2.1, revises the language and deletes the table at paragraph 4.2.1 to prevent inconsistences with the Table of Contents in the specifications package, and incorporates paragraph 8.12.5. Revisions to the Statement of Work are highlighted in red font. (c) Replace in its entirety the Davis Bacon Wage Determination from the original solicitation titled "(c)_CE0965_00 73 00_Davis Bacon Wage Det_WA20250111_Mod8_15AUG25" with the current Davis Bacon Wage Determination "(c)_CE0965_00 73 00_Davis Bacon Wage Det_WA20250111_Mod10_29AUG25". (d) Replace in its entirety the specifications package from the original solicitation titled "(e) CE0965_BJ00567_Specs1" with a revised specifications package titled "(e) CE0965_BJ00567_Specs1_Rev1_25AUG25." This revised specifications package addresses inconsistencies found in the Specifications Table of Contents and adds clarifying language on page three of the Specifications Table of Contents. (e) Provide a Mechanical As Builts package titled "CE0965_Mechanical As Builts" for bidder information purposes. (f) Provide the site visit sign-in sheet from the site visit which was conducted on 25 August 2025.*****

Invitation for Bids for an anticipated firm-fixed-price (FFP) contract to repair the HVAC and Direct Digital Controls (DDC) for Building J00567 on McChord Field, Joint Base Lewis-McChord (JBLM), WA. The project will deliver a fully functional, energy-efficient HVAC system with integrated DDC and network connectivity, supporting remote monitoring and compliance with JBLM and Unified Facilities Criteria (UFC) standards. The contractor shall provide all labor, materials, equipment, and supervision necessary to: (1) demolish and replace the existing HVAC and steam systems in accordance with the construction documents; (2) phase work in 25% sections to maintain conditioned space and facilitate occupant relocation during construction; (3) install new HVAC units, ductwork, and perform testing and balancing to verify performance; (4) implement a BACnet-based DDC system with Java Application Control Engine (JACE) controllers connected to the JBLM network; and (5) install a fiber optic line, network switch, and uninterrupted power supply to support the Enterprise Energy Data Reporting System (EEDRS), including NEMA-rated components where required.

Update #1 ·

Invitation for Bids for an anticipated firm-fixed-price (FFP) contract to repair the HVAC and Direct Digital Controls (DDC) for Building J00567 on McChord Field, Joint Base Lewis-McChord (JBLM), WA. The project will deliver a fully functional, energy-efficient HVAC system with integrated DDC and network connectivity, supporting remote monitoring and compliance with JBLM and Unified Facilities Criteria (UFC) standards. The contractor shall provide all labor, materials, equipment, and supervision necessary to: (1) demolish and replace the existing HVAC and steam systems in accordance with the construction documents; (2) phase work in 25% sections to maintain conditioned space and facilitate occupant relocation during construction; (3) install new HVAC units, ductwork, and perform testing and balancing to verify performance; (4) implement a BACnet-based DDC system with Java Application Control Engine (JACE) controllers connected to the JBLM network; and (5) install a fiber optic line, network switch, and uninterrupted power supply to support the Enterprise Energy Data Reporting System (EEDRS), including NEMA-rated components where required.

Files

Show all 19

Notice history

Similar open opportunities

Opportunity Agency Set-aside Responses due
Joint Base Lewis McChord (JBLM) Multi Domain Task Force (MDTF) Buildings (BLDGs) 3223 and 3224 Joint Base Lewis McChord, Washington, United States · NAICS 236220 ENDIST Seattle Total Small Business
Joint Base Lewis McChord (JBLM) Multi Domain Task Force (MDTF) Buildings (BLDGs) 3221 and 3222 Joint Base Lewis McChord, Washington, United States · NAICS 236220 ENDIST Seattle Total Small Business
FA8501-27-RAPID-990029 RPR RPL HVAC SYSTEM BLDG 300 Bay A/Headhouse Warner Robins, Georgia 31098, United States · NAICS 238220 Air Force Sustainment Center No set-aside
OK-deep fork NWR-quarters HVAC replacem NAICS 238220 — Total Small Business
John Day Dam Powerhouse HVAC Upgrades (W9127N27BA007) Near Rufus, Oregon 97050 · NAICS 238220 ENDIST Portland No set-aside