R499--509-24-2-4105-0008 Replaces Contract: 36C24719P0426 Security System Service New Base plus Four (VA-24-00023070)

Closed Solicitation Posted

This opportunity was awarded. See the award notice from .

Solicitation number
36C24724Q0280
Agency
Responses due
Set-aside
Service-Disabled Veteran-Owned Small Business

Opportunity facts

Place of performance
Department of Veterans Affairs Charlie Norwood VA Medical Center Augusta, Georgia 30904, United States

Notice details come from SAM.gov. Updated .

About this opportunity

This combined synopsis/solicitation from the Department of Veterans Affairs Networking Office 7 seeks firm-fixed price quotes for electronic security system service and maintenance at two Charlie Norwood VA Medical Centers locations in Augusta, Georgia. The agency requires comprehensive preventative maintenance and repair services for existing Lenel and Avigilon security systems, including 385 cameras, 17 network video recorders, 2 Lenel servers, 200 card readers, and various control panels. Quotes are due by February 16, 2024 to receive consideration. Questions must be submitted by February 2nd and responses will be provided via amendment prior to the deadline.

This requirement has been set aside for Service-Disabled Veteran-Owned Small Businesses. It is assigned NAICS code 561621 with a size standard of $25 million in average annual revenue. The incumbent contractor is HurtVet LLC. The initial base year contract valued at $60,000 includes discretionary funding for repairs and upgrades from March 2024 to March 2025. The agency may also exercise up to four one-year options on the award made under this solicitation. The place of performance will be the two Charlie Norwood VA Medical Centers located at 950 15th Street and 1 Freedom Way in Augusta, Georgia.

Notice text

3 versions

Update #3 · Latest ·

These changes are made to the Statement of Work

26. Contractor shall provide an on-site service technician Monday, Wednesday, and Friday; for a minimum of two hours on site. The on-site service technician shall provide guidance to system administrators to establish system standards and security operations procedures and assist security personnel in day-to-day security system operations. This provides customers with a dedicated resource ensuring system integrity, standardization, and continuity.

Update #2 ·

QUESTIONS AND ANSWERS TO SOLICTIATION 36C24724Q0280, SECURITY SYSTEM

1. Is there an incumbent? And if so who? Yes, HurtVet LLC

2. Is the current Physical Access Control and CCTV systems communicating on the VA network? No

3. Will the government supply the system Dongle ID s for the purpose of updating the system software support plans per the requirement? Lenel Dongle ID IS 102888

4. The solicitation states Contractor shall ensure video recordings and entry/exit logs are maintained for a minimal period of 90 days . Does the existing CCTV system video retention comply with this requirement or will an expansion of hardware/software be required? Yes

5. Since any questions generated from the site survey must go through contracting, will an additional round of questions be answered by contracting after this date? Contracting will not be requesting any additional questions. If you the offeror have any additional questions I suggest you ask during the Site Visit after this amendment the Q&A phase is closed.

SOW, B.1: (pg. 11) & Technical Factors (A) (pg. 56)

Contractor shall provide Service Engineers shall be GSA HSPD-12 certified and authorized providers, schedule 70, category 132 62 Homeland Security Professional Directive 12 Product and Service Components. Products and services for agencies to implement and maintain the requirements of HSPD-12, FIPS-201 and associated NIST special publications.

6. GSA schedule 70 is now obsolete; Recommend contractor have a CSEIP on staff to meet GSA HSPD-12 & FIPS-201 compliance requirements. Will CSEIP certification satisfy this general requirement? Yes

SOW, B.2: (pg. 11) & Technical Factors (A) (pg. 56)

Contractor shall be Lenel Value Added Reseller (VAR) of record, minimally fully certified at the Lenel Certified Professional Level (formerly Gold standard level), authorized by Lenel to support Federal Government in the State of Georgia; evidence of this certification shall be presented if requested.

7. Typically, a VAR of record designation is assigned by the end-customer after the award. Please confirm that a Lenel Federal VAR suffices for this requirement? Yes, If Lenel allow them the support in Georgia

SOW, B.13 & B.14: (pg. 12)

8. Can government confirm total # training hours required annually? Training hours as listed. 1 annual 4 hours course. 1st 40 hours on-site operator training, 2nd year 32 hours remaining years 24 hours.

Current system includes 385 Cameras, 8 UPS (Uninterrupted Power Source), 17 DVRs, 2 Lenel Servers, 200 Card Readers, 175 Control Panels (19-4420 Boards, 27-2220 Boards, 2-2210 Boards, 49-1320 Boards, and 78-1300 Boards)

SOW, B.18: (pg. 13)

Contractor shall provide at no additional cost comprehensive component coverage for the equipment identified in the equipment list. CRL locks provided by Tebarco shall be included in the Comprehensive Parts and Labor Coverage Is SDVOSB vendor required to be an authorized Federal Partner/Reseller for Avigilon, Lenel, Lynx, and Bosch?

9. Can the government provide the equipment listing mentioned in B.18? Equipment listed above

10. Can the government provide listing of all installed equipment including manufacturer, model/part #, quantity, and age of equipment? List will be provided during Site Visit.

11. Can the government provide Lenel Dongle ID s for each location? Lenel Dongle ID is 102888.

12. B.18 17 DVRs Should this read NVRs? It should read 17 NVRs

13. How many Workstations are there? What is the camera count and capacity of each? 10 Workstations. Camera count will be provided during Site Visit

SOW, B.25: (pg. 14)

Contractor shall provide a comprehensive security software support plan to renew the current licensing and keeps pace with all software revisions and advancements as they are made available by manufacturers. Such revisions shall keep the installed system operating with the latest technology and at peak performance. Software upgrades typically occur annually, however many times they have been released several times throughout a given calendar year. An annual renewal of the Lenel Software Support subscription, and up to sixteen (16) hours of Contractor labor per year to perform a software upgrade. On an annual renewal basis, the contract shall be amended to include actual licensing added during the previous year.

14. Please provide system dongle ID? Lenel Dongle ID is 102888

15.Is Lenel SSA current? Need to verify

16. Does an active SSA exist for Avigilon licenses? At one time it was expired, current vendor should have renewed. Need to verify.

Contractor shall provide and utilize an industry standard authentication technology to remotely access the security system and resolve technical issues in real time. A Support Specialist, with the support of a screen sharing session initiated by police staff, will work directly with personnel for initial call support and troubleshooting. If the issue cannot be resolved online, a more refined service response will result in the dispatching of a security service representative.

17. How many service calls per/month are typically performed? There is an average of 5 service calls per month. In addition to the weekly schedule.

SOW, B.29: (pg. 14)

Contractor shall provide a web-based reporting system to include the application of unique, registered barcodes to security devices such as cameras, video recorders, card readers, control panels, head-end equipment, and other system devices. As each individual device is tested, the device is scanned and critical maintenance information is documented. In addition, the data at the time of inspection is automatically recorded with the scan of the barcode. Monthly reports will be provided corresponding to PMI performed. Within 48 hours following the inspection visit, an on-line database and associated report of the system test shall be available for viewing, downloading, printing, or emailing. This maintenance information must be retrievable using a standard internet browser. Color-coded status flags will provide an immediate summary of the building test status: normal, discrepancies found, or devices failed. Proposed solutions to 36C24724Q0280 Page 15 of 75 Page 15 of 75 resolve discrepancies or failed devices will always be included. The web-based reporting system shall provide immediate documentation to show the security systems are being tested and inspected according to manufacturer s requirements and in a timely manner.

18. Are all existing devices barcoded? If so, which reporting system is currently in use? There are no existing barcodes

Contractor shall ensure video recordings and entry/exit logs are maintained for a minimal period of 90 days.

19. Does the existing system allow for 90 days of video and access control retention? The system retains video for up to 90 days

Update #1 ·

This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in Federal Acquisition Regulation (FAR) subpart 12.6, Streamlined Procedures for Evaluation and Solicitation for Commercial Items, as supplemented with additional information included in this notice. Solicitation 36C24724Q0280 is issued as a request for quotation. This announcement constitutes the only solicitation; quotations are being requested, and a written solicitation document will not be issued. The solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular 2023-01. This solicitation is issued as A SDVOSB set-aside, the associated NAICS code is 561621 and small business size $25.0 million.

DESCRIPTION: The Department of Veterans Affairs, Networking Office 7 is looking to award a firm-fixed price purchase order for a service and maintenance on the existing Lenel & Avigilon Electronic Security Systems for the Charlie Norwood VA Medical Centers located at 950 15th Street, Augusta, GA 30901 and 1 Freedom Way, Augusta, GA 30904.

TERMS: This requirement incorporates one or more clauses/provisions by reference, with the same force and effect as if they were given in full text. The full text of a clause or provision may be accessed at http:///www.acquisition.gov/far/index.html and http://www.va.gov/oal/library/vaar/. Offerors are encouraged to, and responsible for, reviewing the full solicitation (attached) for detailed requirement description, applicable terms and conditions, provisions, submittal instructions to offerors, and evaluation procedures prior to submitting their quotes. All Offerors must have an active registration in the System for Award Management (SAM), www.sam.gov, at the time of submittal.

QUESTIONS: Any questions pertaining to this requirement must be emailed to sheryl.harris5@va.gov no later than 12:00 PM CT, February 2, 2024, and include Solicitation 36C24723Q0280 in the subject line of the email to ensure timely review and response. No questions will be accepted nor answered after this date and time. Response to questions will be posted as an amendment to the solicitation once the question period has expired. Offerors are responsible for monitoring Contracting Opportunities at www.sam.gov for any amendments to the solicitation as the government will not send notice of amendments. Representatives from potential Offerors or on behalf of potential Offerors shall not contact any VA Medical Center representative to discuss nor inquire about this solicitation.

DEADLINE: All offers/quotes must be submitted in a single email to sheryl.harris5@va.gov and received no later than 10:00 AM CT, February 8, 2024, and 36C24724Q0280 Page 5 of 28 include Solicitation 36C24724Q0280 in the subject line of the email. Offerors are encouraged to, and responsible for, reviewing the full solicitation (attached) for detailed requirement description, applicable terms and conditions, provisions, submittal instructions to offerors, and evaluation procedures prior to submitting their quotes.

Files

File Type Posted
36C24724Q0280 0002_1.docx DOCX document
36C24724Q0280 0002.docx DOCX document
36C24724Q0280 0001_1.docx DOCX document
36C24724Q0280.docx DOCX document

Notice history

Notice Type Posted
R499--Security System Service for the Augusta VAMC Award Award Notice
This notice Latest solicitation Solicitation

Similar open opportunities

Opportunity Agency Set-aside Responses due
Boise VA Security Equipment & Software Service Maintenance Boise, Idaho 83702, United States · NAICS 561621 Veterans Integrated Service Network 20 Service-Disabled Veteran-Owned Small Business
N063--FY 27 Building 111 Project Lighthouse C-CURE Installation C.W. Bill Young VA Healthcare System 10000 Bay Pines Blvd Bay Pines, Florida 33744, United States · NAICS 561621 Veterans Integrated Service Network 8 Service-Disabled Veteran-Owned Small Business
7A21--460-24-009 CLC and Fourth Floor Patient Elopement System Wilmington VA Medical Center 1601 Kirkwood Highway Wilmington DE 19805 · NAICS 238210 Veterans Integrated Service Network 4 Service-Disabled Veteran-Owned Small Business
Twenty-One Access-Control Door Panels and Enclosures and LenelS2 Onguard System Integration Patrick Air Force Base, Florida 32925, United States · NAICS 561621 Defense Health Agency No set-aside
J012-- Fire Alarm Suppression Maintenance & Repair Services NAICS 561621 Veterans Integrated Service Network 16 Service-Disabled Veteran-Owned Small Business