Quality Assurance Service meeting or exceeding the accreditation of the American College of Radiology for three 3T and two 7T scanners.

Closed Solicitation Posted

Solicitation number
75N95023Q00660
Agency
Responses due
Set-aside
Total Small Business

Opportunity facts

Place of performance
Bethesda, Maryland 20814, United States

Notice details come from SAM.gov. Updated .

About this opportunity

The contract opportunity involves the acquisition of a comprehensive quality assurance service for the NIIH/NIMH/FMRIF's 3T and 7T MRI systems, which are used for high resolution fMRI research. The service must meet or exceed the QA and safety requirements for accreditation by the American College of Radiology (ACR accreditation). An annual complete system performance evaluation is also included in the contract.

Products and Services to be provided:

  1. Comprehensive quality assurance service for 3T MRI systems.
  2. Comprehensive quality assurance service for 7T MRI systems.
  3. Meeting or exceeding the QA and safety requirements for ACR accreditation.
  4. Annual complete system performance evaluation.
  5. Maintenance and assurance of MRI system hardware.

Notice text

The NIIH/NIMH/FMRIF currently operates three 3T (high field) and two 7T (ultra-high field) human MRI systems within the NMR MRI Research Center at NIH.

  • FMRIF 3TA (GEHealthcare MR750 3T)
  • FMRIF 3TB (GE Healthcare MR750 3T)
  • FMRIF 3TD (Siemens Skyra 3T)
  • FMRIF 7TA (Siemens Magnetom 7T Plus)
  • FMRIF 7TB (Siemens Magnetom 7T Terra)

The performance of all these systems is exquisitely sensitive to all the subsystems of the MRI. The quality of the fMRI research conclusions thus depends on the quality of the fMRI source data, which in turn depends on the performance of the MRI system hardware.

To obtain high quality images, all the subsystems of the MRI system (main magnet, radiofrequency transmit and receive, and gradients) must be operating within very stringent tolerances. This is especially important for the state-of-the-art and bleeding edge research methods being used for high resolution fMRI research, whose requirements are significantly more demanding than those for routine clinical MRI.

The specific objective of this purchase is the acquisition of an independent, comprehensive quality assurance service meeting or exceeding the QA and safety requirements for accreditation by American College of Radiology (ACR accreditation) for FMRIF’s 3T systems, and a comprehensive quality assurance service similar to, and meeting or exceeding the QA and safety requirements for accreditation by American College of Radiology (ACR accreditation) for 1.5T and 3.0T MRI systems, for FMRIF’s 7T systems. A complete system performance evaluation will be performed annually.

Files

Similar open opportunities

Opportunity Agency Set-aside Responses due
Quantitative Analysis of Longitudinal MR Images Bethesda, Maryland, United States · NAICS 541714 Office of Logisitics and Acquisition Operations No set-aside
Q522--3T Mobile MRI Trailer and Technologist Services NAICS 621512 Veterans Integrated Service Network 8 No set-aside
H265--diagnostic imaging equipment testing Florida 32608, United States · NAICS 621512 Veterans Integrated Service Network 8 Service-Disabled Veteran-Owned Small Business
3D Image Reconstruction and Case Planning Services Gainesville, Florida 32610, United States · NAICS 621512 Veterans Integrated Service Network 8 Total Small Business
AJ11--Supine to Seated or Standing Lumbar Spine MRI Scan Services Contractor's facility · NAICS 621512 Veterans Integrated Service Network 4 No set-aside

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity

GovTribe for Federal Contractors