N063--Building 37 Med Gas Master Alarm Panel Installation
Closed Solicitation Posted
- Solicitation number
- 36C25625Q0838
- Agency
-
Veterans Integrated Service Network 16
Veterans Health Administration, Department of Veterans Affairs
- Responses due
- Set-aside
- Service-Disabled Veteran-Owned Small Business
Opportunity facts
- NAICS code
- 238290 Other Building Equipment Contractors
- Points of contact
Notice details come from SAM.gov. Updated .
About this opportunity
The Department of Veterans Affairs Veterans Health Administration is seeking a service-disabled veteran-owned small business (SDVOSB) to install a medical gas master alarm panel in Building 37 at the Veterans Health Care System of the Ozarks in Fayetteville, Arkansas. The solicitation (36C25625Q0838) requires the contractor to furnish and install an Amico A2M-E-30 Alert-2 medical gas master alarm panel or equivalent, with complete integration into the existing medical gas system. Contractors must have five years of healthcare construction experience and hold an ASSE 6020 Medical Gas Systems Inspector certification. The evaluation will likely focus on past performance, technical capability, and compliance with specific installation requirements detailed in the solicitation. Quotations were originally due by May 20, 2025, at 9:00 AM CST, though subsequent amendments have extended the deadline to June 6, 2025, at 3:00 PM CST.
The contract is a 100% set-aside for service-disabled veteran-owned small businesses under NAICS code 238290, with a small business size standard of $22 million. The period of performance is 60 calendar days, spanning from June 1, 2025, to May 31, 2026. Contractors must be VetCert certified and capable of completing the installation in Building 37's corridor, including all necessary testing and certification. The project requires connecting to the existing medical gas system and providing a 5-year manufacturer warranty. The estimated cable routing distance is approximately 900 feet, and the total project involves installing a new medical gas master alarm panel with specific technical requirements. Contractors will submit their quotations via email to Lakeisha White, with the project located at the G.V. (Sonny) Montgomery VA Medical Center in Ridgeland, Mississippi.
Notice text
3 versions
Update #3 · Latest ·
5. PROJECT NUMBER (if applicable)
CODE
7. ADMINISTERED BY
2. AMENDMENT/MODIFICATION NUMBER
CODE
6. ISSUED BY
8. NAME AND ADDRESS OF CONTRACTOR
4. REQUISITION/PURCHASE REQ. NUMBER
3. EFFECTIVE DATE
9A. AMENDMENT OF SOLICITATION NUMBER
9B. DATED
PAGE OF PAGES
10A. MODIFICATION OF CONTRACT/ORDER NUMBER
10B. DATED
BPA NO.
1. CONTRACT ID CODE
FACILITY CODE
CODE
Offers must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended, by one of the following methods:
The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offers
E. IMPORTANT:
is extended,
(a) By completing Items 8 and 15, and returning __________ copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the
offer submitted; or (c) By separate letter or electronic communication which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR
ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY
is not extended.
12. ACCOUNTING AND APPROPRIATION DATA
(REV. 11/2016)
is required to sign this document and return ___________ copies to the issuing office.
is not,
A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE CONTRACT ORDER NO. IN ITEM 10A.
15C. DATE SIGNED
B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES
SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(b).
RESULT IN REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by letter
or electronic communication, provided each letter or electronic communication makes reference to the solicitation and this amendment, and is received prior to
the opening hour and date specified.
C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:
D. OTHER
Contractor
16C. DATE SIGNED
14. DESCRIPTION OF AMENDMENT/MODIFICATION
16B. UNITED STATES OF AMERICA
Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.
15A. NAME AND TITLE OF SIGNER
16A. NAME AND TITLE OF CONTRACTING OFFICER
15B. CONTRACTOR/OFFEROR
STANDARD FORM 30
PREVIOUS EDITION NOT USABLE
Prescribed by GSA - FAR (48 CFR) 53.243
(Type or print)
(Type or print)
(Organized by UCF section headings, including solicitation/contract subject matter where feasible.)
(Number, street, county, State and ZIP Code)
(If other than Item 6)
(Specify type of modification and authority)
(such as changes in paying office, appropriation date, etc.)
(If required)
(SEE ITEM 11)
(SEE ITEM 13)
(X)
CHECK
ONE
13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS,
IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.
11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS
AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT
(Signature of person authorized to sign)
(Signature of Contracting Officer)
1
1
0002
05-22-2025
10N16
Department of Veterans Affairs
Network Contracting Office 16
715 S Pear Orchard
Plaza 1
Ridgeland MS 39157
10N16
Department of Veterans Affairs
G.V. (Sonny) Montgomery VAMC
A&MM Service (90C)
715 South Pear Orchard Road
Ridgeland MS 39157
To all Offerors/Bidders
36C25625Q0838
05-08-2025
X
X
X
1
** HOUR & DATE for Receipt of Offers is EXTENDED to: 05-29-2025 15:00 CDT
X
(1) One
The purpose of this amendment is to extend the solicitation due date for submission of quotes.
A. The updated hour and date specified for receipt of offers is extended to 05/29/2025 at 3:00 PM (CST).
B. Questions and Answers (Q&A) will be provided on a subsequent amendment.
Note: Contractor must acknowledge this amendment by signing in box 15b and submit with quote before the solicitation due
date. If not acknowledged, contractor may be ineligible for award at the discretion of the Contracting Officer.
Page 2 of 2
End of Document
Update #2 ·
5. PROJECT NUMBER (if applicable)
CODE
7. ADMINISTERED BY
2. AMENDMENT/MODIFICATION NUMBER
CODE
6. ISSUED BY
8. NAME AND ADDRESS OF CONTRACTOR
4. REQUISITION/PURCHASE REQ. NUMBER
3. EFFECTIVE DATE
9A. AMENDMENT OF SOLICITATION NUMBER
9B. DATED
PAGE OF PAGES
10A. MODIFICATION OF CONTRACT/ORDER NUMBER
10B. DATED
BPA NO.
1. CONTRACT ID CODE
FACILITY CODE
CODE
Offers must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended, by one of the following methods:
The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offers
E. IMPORTANT:
is extended,
(a) By completing Items 8 and 15, and returning __________ copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the
offer submitted; or (c) By separate letter or electronic communication which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR
ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY
is not extended.
12. ACCOUNTING AND APPROPRIATION DATA
(REV. 11/2016)
is required to sign this document and return ___________ copies to the issuing office.
is not,
A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE CONTRACT ORDER NO. IN ITEM 10A.
15C. DATE SIGNED
B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES
SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(b).
RESULT IN REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by letter
or electronic communication, provided each letter or electronic communication makes reference to the solicitation and this amendment, and is received prior to
the opening hour and date specified.
C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:
D. OTHER
Contractor
16C. DATE SIGNED
14. DESCRIPTION OF AMENDMENT/MODIFICATION
16B. UNITED STATES OF AMERICA
Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.
15A. NAME AND TITLE OF SIGNER
16A. NAME AND TITLE OF CONTRACTING OFFICER
15B. CONTRACTOR/OFFEROR
STANDARD FORM 30
PREVIOUS EDITION NOT USABLE
Prescribed by GSA - FAR (48 CFR) 53.243
(Type or print)
(Type or print)
(Organized by UCF section headings, including solicitation/contract subject matter where feasible.)
(Number, street, county, State and ZIP Code)
(If other than Item 6)
(Specify type of modification and authority)
(such as changes in paying office, appropriation date, etc.)
(If required)
(SEE ITEM 11)
(SEE ITEM 13)
(X)
CHECK
ONE
13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS,
IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.
11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS
AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT
(Signature of person authorized to sign)
(Signature of Contracting Officer)
1
3
0001
05-20-2025
10N16
Department of Veterans Affairs
Network Contracting Office 16
715 S Pear Orchard
Plaza 1
Ridgeland MS 39157
10N16
Department of Veterans Affairs
G.V. (Sonny) Montgomery VAMC
A&MM Service (90C)
715 South Pear Orchard Road
Ridgeland MS 39157
To all Offerors/Bidders
36C25625Q0838
05-20-2025
X
X
X
1
** HOUR & DATE for Receipt of Offers is EXTENDED to: 05-22-2025 15:00 CDT
X
(1) One
The purpose of this amendment is to extend the solicitation due date for submission of quotes and to
provide responses to questions that were received.
A. The updated hour and date specified for receipt of offers is extended to 05/22/2025 at 3:00 PM (CST).
B. Questions and Answers (Q&A) are provided on the following pages.
Note: Contractor must acknowledge this amendment by signing in box 15b and submit with quote before the solicitation due
date. If not acknowledged, contractor may be ineligible for award at the discretion of the Contracting Officer.
Page 3 of 3
Med Gas Alarm Panel Install Questions and Answers
The contract requires a 5-year manufacturer warranty, the standard warranty is 1 or 2 years, we are not positive this requirement can be met. Please verify.
Yes, we want the 5-year warranty
SOW F (2) should list 6030 not 6020. Must be Verified, not inspected.
This is correct a 6030 is what would be needed not the 6020.
Can you provide the most recent annual medical gas inspection report for the facility?
No
The primary location for the master alarm panel is not suitable; it is behind doors that normally open/close. Alternate location is in the hallway but requires clarification from AHJ if the proposed location meets NFPA 5.1.9.2.1 (1). One master alarm panel shall be located in the office or workspace of the on-site individual responsible for the maintenance of the medical gas and vacuum piping systems . Is this within visual/audible range of the person/shop responsible for the system?
The primary location is within 6ft of their workstation and the door to the area remains open while the person is at work. This location also allows the maximum exposure to the panel for other staff members and the supervisor who would serve as a backup for repairs.
Where is the current master alarm panel? Is it in an area of continuous observation per NFPA 5.1.9.2.1 (2)?
The current master alarm panel is monitored 24 hr a day and is located in the emergency department. See attached drawing
Can you provide a picture of the current master alarm panel?
See attached photo
If the current master alarm panel is not Amico, it might have to be retrofitted. Panel manufactures need to match or you can have an issue due to the power supply voltage loop through the switches. Verify existing panel manufacturer.
See attached photo
Is the current master alarm panel wiring up to code? NFPA 5.1.9.2.3.1 (A):(D)
The panel is up to code and has passed the annual inspection.
If the current master alarm panel does not meet NFPA 5.1.9.2.3.1 (A):(D), will it be required to be brought to current code?
No, only to install the Med Gas panel in building 37 in a manner that meets code.
Can you provide floor plans for the facility that shows the locations of the source equipment? Oxygen, Medical Air, Medical Vacuum, Nitrous Oxide Manifold, Nitrogen Manifold, etc. We would also need the locations of the main line pressure switches shown on the plans. Needs to be noted on the plans to estimate distance for conduit and LV wire.
See attached floor plan
Are the existing main line pressure switches fully functional? Do they have gas specific demand checks and gauges?
To our knowledge they are fully functional.
The new master alarm panel is required to be 120VAC e-power. Has a spare breaker been identified for the new circuit? If so, can you show the location of the breaker on plans?
There is no emergency power located in building 37 and no circuit has been Identified. A electrical panel is located with in 20 feet of the primary and alternate location of the proposed med gas panel
Is there a chase, tunnel, or anything connecting the hospital to Bldg 37? If not, this would require digging to install conduit connecting the two buildings.
There is not a chase or tunnel. There is buried conduit connecting building 1 to building 37. There is no drawing of the path of the conduit.
Are we integrating the new master alarm panel with the BMS?
No, it will not be integrated with the Building management system.
Update #1 ·
COMBINED SYNOPSIS/SOLICITATION FOR COMMERCIAL ITEMS
General Information
Document Type:
Combined Solicitation/Synopsis
Solicitation Number:
36C25625Q0838
Posted Date:
May 8, 2025
Original Response Date:
May 20, 2025
Current Response Date:
May 20, 2025
Product or Service Code:
N063
Set Aside (SDVOSB/VOSB):
SDVOSB
NAICS Code:
238290
Contracting Office Address
715 S. Pear Orchard
Plaza 1
Ridgeland, MS 39157
Description
This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in Federal Acquisition Regulation (FAR) subpart 12.6, Streamlined Procedures for Evaluation and Solicitation for Commercial Items, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotations are being requested, and a written solicitation document will not be issued.
This solicitation is a request for quotations (RFQ). The solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular 2024-05.
The associated North American Industrial Classification System (NAICS) code for this procurement is 238290, with a small business size standard of $22M. There is a 100% SDVOSB set-side for this solicitation.
The Veterans Health Care System of the Ozarks (Fayetteville. AR) is seeking to purchase Wheelchair Transportation Services.
All offerors shall submit 1 quotation/offer to the following email address.
Submission shall be received no later than 05/20/25, 9AM CST at Lakeisha.white@va.gov. Hand delivered or fax quotes shall not be accepted.
Any questions or concerns regarding this solicitation should be forwarded in writing via e-mail to the contracting officer below.
Point of Contact
Lakeisha White
Lakeisha.white@va.gov
Files
| File | Type | Posted |
|---|---|---|
| IMG_0403.jpg | JPG image | |
| Building 1 basement blue print.pdf | ||
| 36C25625Q0838 0004_1 SAM POSTING.pdf | ||
| building 37.pdf | ||
| Med gas panel points of interest.pdf | ||
| building 1 floor plan Med gas alarm panel bld 37.pdf | ||
| 36C25625Q0838 0003_1.pdf | ||
| 36C25625Q0838 0002_1.docx | DOCX document | |
| 36C25625Q0838 0001_1.docx | DOCX document | |
| Panel Photo.pdf | ||
| Building Floor Plan.pdf | ||
| Attachment D. 2 Drawing Engineering Shops.pdf | ||
| 36C25625Q0838_1.docx | DOCX document | |
| Attachment D. 3 Campus Map.pdf | ||
| Solicitation 36C25625Q0838.pdf | ||
| Wage Determination No. 2015-5109 Revision 26.pdf | ||
| Attachment D.4 Past Performance References.pdf | ||
| S02. Attachment D.1 Final Invoice Memo.pdf |
Show all 18
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| Y1DA--Project620-22-110 Replace and Upgrade Fire alarm System at Montrose VAMC | Veterans Integrated Service Network 2 | Service-Disabled Veteran-Owned Small Business | |
| Medical Gas System Activation and Bulk Oxygen Tank Services | Veterans Integrated Service Network 9 | Service-Disabled Veteran-Owned Small Business | |
| N048-- B41 Isolation Valve Installation | Veterans Integrated Service Network 16 | Service-Disabled Veteran-Owned Small Business | |
| N099--JLM Roll Up Door Replacement | Veterans Integrated Service Network 16 | Service-Disabled Veteran-Owned Small Business | |
| 6835--Med Gas Base Plus Four | Veterans Integrated Service Network 22 | Service-Disabled Veteran-Owned Small Business |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity