J042--Fire and Electric Doors PM and Repairs 612-26-2-6133-0027

Closed Pre-Solicitation Posted

This opportunity was awarded. See the award notice from , or the latest solicitation from .

Solicitation number
36C26126Q0302
Agency
Responses due
Set-aside
Service-Disabled Veteran-Owned Small Business

Opportunity facts

Place of performance
Department of Veterans Affairs North California VA Health Care System Mather CA 95655, United States

Notice details come from SAM.gov. Updated .

About this opportunity

The Department of Veterans Affairs Veterans Health Administration is seeking qualified contractors to provide inspection, preventive maintenance, repair, and emergency services for automatic sliding and swinging doors, fire-rated pedestrian doors, and associated control systems at multiple VA Northern California Health Care System locations. The contractor must demonstrate the ability to meet all requirements outlined in the attached Statement of Work, including compliance with ANSI/BHMA standards and NFPA codes. Key qualifications include technical experience with automatic door systems, fire-rated doors, and related equipment, as well as bonding capability. The evaluation will assess business size and socio-economic status, along with technical experience and compliance capability. Responses to this Sources Sought notice must be submitted in writing by January 19, 2026, at 12:00 PM PDT, including detailed capability information such as SAM UEI, DUNS number, and bonding capability.

This procurement is set aside exclusively for Service-Disabled Veteran-Owned Small Businesses (SDVOSB), though Veteran-Owned Small Businesses (VOSB) may also respond. The qualifying NAICS code is 811310 (Commercial and Industrial Machinery and Equipment Repair and Maintenance), and the PSC code is J042. The contract requires quarterly preventive maintenance, annual fire door inspections, and a 4-hour response time for repair service calls during business hours across multiple VA sites in Northern California, including locations in Mather, McClellan, Vallejo, Travis AFB, Stockton, and Martinez. The notice does not disclose the budget range, potential award value, or the name of any current incumbent contractor. This is a Sources Sought announcement for market research purposes only and does not constitute a formal solicitation.

Notice text

THIS REQUEST FOR INFORMATION (RFI) SOURCES SOUGHT IS ISSUED SOLELY FOR MARKET RESEARCH AND PLANNING PURPOSES ONLY AND DOES NOT CONSTITUTE A SOLICITATION

Subject:Â Sources Sought, Automatic Door Maintenance and Fire Door System Inspection & Testing for the Department of Veterans Affairs, Veterans Health Administration, Regional Procurement Office West, Network Contracting Office 21 (NCO 21) on behalf of the VA Northern California Health Care System.

Responses to this Sources Sought must be in writing. The purpose of this Sources Sought Announcement is for market research only to make appropriate acquisition decisions and to gain knowledge of Small Businesses, including Service-Disabled Veteran-Owned Small Businesses and Veteran-Owned Small Businesses (SDVOSB/VOSB), who are interested in submitting proposals for this procurement and who can perform the work required for this procurement.

NCO 21 is requesting responses from qualified business concerns; the qualifying NAICS code for this effort is 811310 Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance.

Background:Â The Department of Veterans Affairs is seeking contractors to provide inspection, preventive maintenance, repair, and emergency service of all automatic and fire-rated pedestrian doors installed at various VA Northern California Health Care System sites. Contractors must demonstrate their ability to meet all requirements listed in the attached Statement of Work (SOW).

Scope of Work Overview:

Introduction:

This project encompasses the maintenance of automatic and fire-rated pedestrian doors at multiple VA Northern California Health Care System locations.

Scope:

Provide all necessary labor, materials, equipment, and supervision to complete inspection, maintenance, and repair of automatic sliding and swinging doors, low- and high-energy operators, motion and presence sensors, control and access systems, and fire-rated pedestrian doors.

General Requirements:

Compliance with ANSI/BHMA standards, NFPA codes, California Building and Fire Codes, and VA regulations.

AAADM certification for technicians or equivalent experience.

Maintenance logs, coordination with the VA COR, and annual fire door inspection per NFPA 80.

Preventive Maintenance:

Quarterly and annual preventive maintenance tasks, including inspection, adjustment, cleaning, and testing of door components.

Unscheduled Maintenance and Repairs:

Additional work requests, quotes, and approvals for repairs outside the regular schedule.

Corrective Maintenance & Repairs:

Response times for repair service calls during business hours and emergency after-hours service.

Documentation and Reporting:

Detailed service reports, quarterly maintenance summaries, and compliance with NFPA 80 for fire door inspections.

Safety and Infection Control:

Compliance with VA safety and infection control policies.

Quality Control:

Implementation of a quality control plan to meet industry standards.

Billing and Invoicing:

Invoicing requirements compliant with VA financial and procurement regulations.

Additional Requirements:

Identification, security, access procedures, and records management.

Information Requested: The Government requests that interested parties review the attached SOW and provide the following capability information to the Contract Specialist, Edwin Rivera, at edwin.rivera@va.gov by 12:00 PM PDT on January 19, 2026. Please place Attention: 36C26126Q0302 Automatic Door Maintenance VANCHCS in the subject line of your email.

Business Size (Large/Small)

Business Socio-Economic Status (SDVOSB, WOSB, 8(a), HUBZone, etc.)

Identify if you are the Prime contractor or Subcontractor

SAM Unique Entity ID (UEI)

DUNS number

Bonding Capability; per contract and aggregate. Provide the amount of aggregate bonding currently available (i.e., amount not committed).

Anticipated Teaming Arrangements (if applicable).

Is the anticipated period of performance realistic for this project?

Include general information and technical background describing your firm's experience on contracts requiring similar efforts to meet the program objectives.

List of Sub-Contractors you intend to use on this project, including but not limited to: Mechanical, Electrical, Controls.

If applicable, how does your company intend to meet the Limitations on Subcontracting as per 13 CFR 125.6?

Are your Sub-Contractors from the local area or will they be coming from out of the area? If so, from where?

Notes:Â The information requested above is required for the Government to evaluate whether there are sufficient small business concerns of a particular type who can perform the work required by this procurement to determine if this procurement should be set aside for a given type of small business concern.

Failure to submit all of the information requested above may be viewed by the Government as evidence that the respondent lacks the ability to provide the services required by this procurement. This, in turn, may affect the Government s determination about whether the requirements for a set-aside procurement have been met.

Disclaimer:Â Issuance of this notice does not constitute any obligation whatsoever on the part of the Government to procure these services, or to issue a solicitation, nor to notify respondents of the results of this notice. No solicitation documents exist at this time. The Department of Veterans Affairs is neither seeking proposals nor accepting unsolicited proposals, and responses to this notice cannot be accepted as offers. Any information the contractor considers proprietary should be clearly marked as such. The U.S. Government will not pay for any information or administrative costs incurred in response to this sources sought notice.

Files

File Type Posted
36C26126Q0302.docx DOCX document

Notice history

Notice Type Posted
J042--Fire and Electric Doors PM and Repairs 612-26-2-6133-0027 Award Award Notice
J042--Fire and Electric Doors PM and Repairs Latest solicitation Solicitation
J042--Fire and Electric Doors PM and Repairs Pre-Solicitation
This notice Original Pre-Solicitation

Similar open opportunities

Opportunity Agency Set-aside Responses due
J012--FIRE DAMPER REPAIR SERVICES VA Central California Healthcare System VA Central California Healthcare System 2615 E Clinton Avenue Fresno CA 93703 · NAICS 811310 Veterans Integrated Service Network 21 No set-aside
36C26127Q0086, Fire Extinguisher Inspection and Maintenance Services San Francisco, California, United States · NAICS 811310 Veterans Integrated Service Network 21 Service-Disabled Veteran-Owned Small Business
H112--Annual/Sem-i annual fire smoke inspections and auto door services l EKH Kansas 66048, United States · NAICS 541350 Veterans Integrated Service Network 15 Total Small Business
N099--JLM Roll Up Door Replacement Eugene J. Towbin Healthcare Center Central Arkansas Veterans Healthcare System North Little Rock AR 72114 · NAICS 238290 Veterans Integrated Service Network 16 Service-Disabled Veteran-Owned Small Business
H263--anti-ligature door alarm installation services Department of Veterans Affairs San Diego VA Medical Center San Diego CA 92161, United States · NAICS 561621 Veterans Integrated Service Network 22 Service-Disabled Veteran-Owned Small Business

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity

GovTribe for Federal Contractors