Install Backup Chiller B700
Closed Solicitation Posted
Not the latest version. See the latest solicitation from .
- Solicitation number
- W50S7525QA021
- Agency
-
Army National Guard
Department of the Army, Department of Defense
- Responses due
- Set-aside
- Woman-Owned Small Business
Opportunity facts
- NAICS code
- 236220 Commercial and Institutional Building Construction
- Place of performance
- Port Hueneme, California, United States
Notice details come from SAM.gov. Updated .
About this opportunity
The Department of the Army National Guard is procuring construction services to install a backup chiller system (B700) at the Channel Islands Air National Guard Station in Port Hueneme, California. The project involves placing a 6-inch concrete housekeeping pad, installing a new 68.6-ton capacity air-cooled chiller with 116.6 GPM flow rate, and completing all necessary mechanical and electrical connections including integration with the existing Automated Logic Building Automation System. Contractors must provide all labor, materials, and equipment while complying with multiple industry standards including AHRI, ASHRAE, ASME, NEC, NEMA, and NFPA regulations, along with submitting weekly progress reports and providing a minimum one-year warranty. The Contracting Officer will evaluate quotes based on technical risk and price considerations. Critical dates include the site visit on July 23, 2025, the RFI deadline on July 28, 2025, and the quote submission deadline of August 1, 2025 at 4:30 PM.
This solicitation is designated as a 100% Women-Owned Small Business set-aside with no incumbent contractors identified in the documentation. The project has an estimated value between $100,000 and $250,000, with a total project maintenance budget of $250,000. The contract requires a 30-calendar day mobilization period followed by a 180-calendar day performance period for completion, with work originally scheduled to be finished by June 11, 2025. The chiller specifications include 460V/3-phase electrical requirements and an efficiency rating of 0.695 KW/Ton, operating between 56.1°F and 42°F temperatures. Performance will take place at the Channel Islands Air National Guard Station in Port Hueneme, California, where contractors must coordinate with base facility managers and adhere to strict security and access protocols.
Notice text
3 versions
Update #3 · Latest ·
-29 July 2025: Amendment to solicitation W50S7525QA0210001
Added-
Attachment 6: WAGE DETERMINATION (new)
Attachment 7: RFI Log
Attachment 8: Attachment 8 Site Pictures (Existing Electrical Components)
-
-23 July 2025: Added Site Visit Sign In Sheet
-
-17 July 2025: Please see attached 1442 and list of attachments.
Attachment 1: Drawings
Attachment 2: Specifications Div 00-21
Attachment 3: Specifications Div 22-33
Attachment 4: Pictures
Attachment 5: STATEMENT OF WORK
Attachment 6: WAGE DETERMINATION
Significant dates:
23 July: Site Visit
28 July: RFI Deadline
1 August 2025 4:30 PM: Quote Due
Update #2 ·
-23 July 2025: Added Site Visit Sign In Sheet
-
-17 July 2025: Please see attached 1442 and list of attachments.
Attachment 1: Drawings
Attachment 2: Specifications Div 00-21
Attachment 3: Specifications Div 22-33
Attachment 4: Pictures
Attachment 5: STATEMENT OF WORK
Attachment 6: WAGE DETERMINATION
Significant dates:
23 July: Site Visit
28 July: RFI Deadline
1 August 2025 4:30 PM: Quote Due
Update #1 ·
17 July 2025: Please see attached 1442 and list of attachments.
Attachment 1: Drawings
Attachment 2: Specifications Div 00-21
Attachment 3: Specifications Div 22-33
Attachment 4: Pictures
Attachment 5: STATEMENT OF WORK
Attachment 6: WAGE DETERMINATION
Significant dates:
23 July: Site Visit
28 July: RFI Deadline
1 August 2025 4:30 PM: Quote Due
Files
Show all 13
Notice history
| Notice | Type | Posted |
|---|---|---|
| Install Backup Chiller B700 | Solicitation | |
| Install Backup Chiller B700 | Pre-Solicitation | |
| This notice | Solicitation | |
| Install Backup Chiller B700 | Pre-Solicitation | |
| Install Backup Chiller B700 | Pre-Solicitation |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| Replace HVAC Rooftop Units at Building 2275 | Army National Guard | No set-aside | |
| Rental of two chillers for one year | Veterans Integrated Service Network 6 | Service-Disabled Veteran-Owned Small Business | |
| Chiller | Land and Maritime | No set-aside | |
| Replacement of 10 Ton HVAC Unit, Bldg. 11, PR ANG | Army National Guard | Total Small Business | |
| Z2NZ--Turn Key Chiller Equipment (Purchase and Install) | Veterans Integrated Service Network 16 | No set-aside |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity