H312--Base +4 Fire and Smoke Door Inspections and Repair Services at Jesse Brown VAMC, Chicago, IL.

Closed Pre-Solicitation Posted

Not the latest version. See the latest solicitation from .

Solicitation number
36C25226Q0196
Agency
Responses due
Set-aside
No set-aside

Opportunity facts

Place of performance
Jesse Brown VA Medical Center 820 S. Damen Avenue Chicago, Illinois 60612, United States

Notice details come from SAM.gov. Updated .

About this opportunity

The Department of Veterans Affairs Veterans Health Administration, through the Great Lakes Acquisition Center in Milwaukee, Wisconsin, is seeking qualified vendors to provide fire and smoke door inspection and repair services at Jesse Brown VA Medical Center in Chicago, Illinois. This pre-solicitation notice is designed to identify capable sources and determine the appropriate acquisition method rather than solicit formal proposals. Interested firms must demonstrate a minimum of three years of consecutive experience in fire alarm inspection and testing services, maintain adherence to NFPA Standards, and possess or be capable of obtaining necessary licensing within Wisconsin. Capability statements will be evaluated based on company experience with similar projects, customer references and contract descriptions, current technician staffing levels, 24/7 emergency response capabilities, hours of operation, and quality control procedures. Vendors must submit their capability statements by January 15, 2026, at 10:00 AM Central Time to be considered for the competitive procurement process.

The contract will be structured as a Base plus four option year contract with no set-aside designation, meaning it will be available for full and open competition. The scope of work involves a comprehensive 15-point NFPA 80-101 inspection of 585 door openings across multiple buildings at the medical center, with small repairs included such as installing mutes, repairing holes, adjusting door closers, and replacing missing screws. No specific award value or budget range has been disclosed in this pre-solicitation notice. Successful vendors will be required to provide a comprehensive inspection report detailing asset inventory, barrier assembly status, and necessary repairs to ensure compliance with applicable fire and smoke door standards. The work falls under NAICS code 561621 (Security Systems Services except Locksmiths) and PSC category H312 (Inspection—Fire Control Equipment).

Notice text

This is not a solicitation for proposals, proposal abstracts, bids, or quotations. The purpose of this notice

is to obtain information regarding the availability and capability of all qualified sources to perform Fire and Smoke Door Inspection and Repair Services at Jesse Brown VAMC. Responses to the information requested will assist the Government in determining the appropriate acquisition method.

The Great Lakes Acquisition Center (GLAC) Milwaukee, WI is soliciting businesses for Fire and Smoke Door Inspection Services at Jesse Brown VAMC on a Base +4 Option Year Contract.

It is understood that all firms submitting a response to this Sources Sought will have an established

business in the Fire Alarm Inspection / Testing industry with a minimum of three (3) years consecutive

experience in performing these types of services in adherence with NFPA Standards. The firm must also

be licensed or capable of obtaining the necessary licensing required to perform these services within the

State of Wisconsin.

The following NAICS Code has been identified for this requirement:

561621 - Security Systems Services (except Locksmiths)

Interested firms shall provide an overview of their firm s capabilities and experience with projects similar in size and scope of this project. Capability statements must include:

a. Company Experience in providing services, to include number of years and any examples of current contracts in place with government or commercial entities;

b. Customer point of contact information for contracts listed in company experience along with

a description of services provided under the contract (types of services provided, volume of

trips per year, geographic service area covered, etc.);

c. Number of technicians currently employed;

d. Description of the ability to provide immediate emergency access and communication

between customers and their personnel 24 hours a day, 7 days a week;

e. Current hours of operation;

f. Examples of Quality Control Programs and Procedures currently utilized by your firm;

g. SAM UEI and DUNS number;

h. Organization Name and Assumed Name/dba (if applicable);

i. Organization Address;

j. Point of Contact (including name, title, addresses, telephone number, fax number, and

Email address);

k. Business size under NAICS code 561621 (small business, other than small business,

Woman-Owned, etc...);

l. Socio-economic status (If SDVOSB or VOSB provide SDVOSB/VOSB CVE verification or

VIP Profile);

m. GSA contract number (if a GSA contract holder);

n. Current state licensing possessed and a brief overview of that state s licensing requirements. If not currently licensed in Wisconsin, discuss any lead-times and processes your firm would take to obtain necessary licensing to perform these services in the State of Wisconsin. (All information shall be submitted in Word or PDF format, not to exceed 25 pages, including all attachments.) Firms shall identify whether they are a small business or other than small business in accordance with the size standard for NAICS code 561621. If another NAICS code may be applicable, please identify the NAICS in your capability statement along with your corresponding business size and socio-economic status.

Scope of Work:

Contractors shall provide all tools, materials, components, labor, and supervision to conduct a 15-point NFPA 80-101 inspection/inventory of 585 door openings. See attachments Bldg.40, Bldg. 1A,1B,1C, and Bldg.11A 11B. Small repairs to assets will be completed during inspection. The repairs listed will be conducted on doors requiring these specific repairs to be compliant.

Repairs Include:

Installation of mutes

Repairing of small holes in doors/frames

Door closer adjustments

Removal of excessive signage

Removal of material from glazing

Replacing missing screw(s)

Installation of hinge filler plates

After the inspection is complete, a comprehensive inspection report must be provided. This report must include a full inventory of all assets, the overall pass/fail of barrier assemblies, and a detailed list of repairs needed to bring any deficient doors into compliance.

Disclaimer and Important Notes: All information must be received no later than Thursday, 01/15/2026 at 10:00 AM (Central Time). Email information to Justin Lemke, Contracting Specialist, at Justin.Lemke@va.gov. The Government will valuate market information to ascertain potential market capacity to provide services consistent in scope and scale with those described in this notice and otherwise anticipated.

Telephone inquiries will not be accepted or returned. BASED ON THE RESPONSES TO THIS SOURCES SOUGHT NOTICE/MARKET RESEARCH, THIS REQUIREMENT MAY BE SET-ASIDE FOR A SPECIFIC SMALL BUSINESS SOCIOECONOMIC CONTRACTING PROGRAM, SMALL BUSINESSES, OR PROCURED THROUGH FULL AND OPEN COMPETITION.

This notice does not obligate the Government to award a contract or otherwise pay for the information provided in response. The Government reserves the right to use information provided by respondents for any purpose deemed necessary and legally appropriate. Any organization responding to this notice should ensure that its response is complete and sufficiently detailed to allow the Government to determine the organization's qualifications to perform the work. Respondents are advised that the Government is under no obligation to acknowledge receipt of the information received or provide feedback to respondents with respect to any information submitted.

Confidentiality: No proprietary, classified, confidential, or sensitive information should be included in

your response. The Government reserves the right to use any non-proprietary technical information in

any resultant solicitation(s).

Files

File Type Posted
36C25226Q0196.docx DOCX document

Notice history

Notice Type Posted
H312--Base 4 Fire and Smoke Door Inspections and Repair Services at Jesse Brown VA Medical Center Latest solicitation Solicitation
H312--Base 4 Fire and Smoke Door Inspections and Repair Services at Jesse Brown VA Medical Center Pre-Solicitation
This notice Original Pre-Solicitation

Similar open opportunities

Opportunity Agency Set-aside Responses due
H112--Annual/Sem-i annual fire smoke inspections and auto door services l EKH Kansas 66048, United States · NAICS 541350 Veterans Integrated Service Network 15 Total Small Business
H399--Elevator Inspection Service FHCC VAMC in North Chicago IL Base 4 OY NAICS 541350 Veterans Integrated Service Network 12 No set-aside
CTX Life Safety Assessment and Fire Damper Inspection Temple, Texas 76504, United States · NAICS 561621 Veterans Integrated Service Network 17 Service-Disabled Veteran-Owned Small Business
H156-- No Award Amendment| WNY Chute, Barrier, & Door Inspections Brooklyn VA Medical Center and VA St. Albans CLC Brooklyn NY 11209 · NAICS 541350 Veterans Integrated Service Network 2 No set-aside
J012--Fire Suppression System Maintenance and Richard L. Roudebush Vamc 1481 W 10th Street Indianapolis, Indiana 46202, United States · NAICS 811310 Veterans Integrated Service Network 10 Service-Disabled Veteran-Owned Small Business

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity

GovTribe for Federal Contractors