36C25226Q0196.docx
DOCX document 28 KB Posted
- Attached to
- H312--Base +4 Fire and Smoke Door Inspections and Repair Services at Jesse Brown VAMC, Chicago, IL.
- Solicitation number
- 36C25226Q0196
About this file
This is a Sources Sought Notice for Fire and Smoke Door Inspection and Repair Services at Jesse Brown VA Medical Center in Chicago, IL. The Department of Veterans Affairs Great Lakes Acquisition Center is seeking qualified vendors to perform a comprehensive 15-point NFPA 80-101 inspection of 585 door openings across multiple buildings, with small repairs included such as installing mutes, repairing holes, adjusting door closers, and replacing missing screws. The contract is structured as a Base +4 Option Year Contract, targeting businesses with at least three years of consecutive experience in fire alarm inspection/testing and adherence to NFPA Standards.
Vendors must submit a detailed capability statement by January 15, 2026, at 10:00 AM Central Time, including company experience, technician count, emergency access capabilities, quality control procedures, licensing information, and socio-economic status. The solicitation uses NAICS code 561621 (Security Systems Services) and may be set-aside for a specific small business socioeconomic contracting program or procured through full and open competition. Respondents must provide a comprehensive inspection report after completing the work, detailing asset inventory, barrier assembly status, and necessary repairs to ensure compliance.
View the file
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Sources Sought Notice Sources Sought Notice
| SUBJECT* |
| Base +4 Fire and Smoke Door Inspections and Repair Services at Jesse Brown VAMC, Chicago, IL. |
GENERAL INFORMATION
| CONTRACTING OFFICE’S ZIP CODE* |
| 53214-1476 |
| SOLICITATION NUMBER* |
| 36C25226Q0196 |
| RESPONSE DATE/TIME/ZONE |
| 01-15-2026 10:00AM CENTRAL TIME, CHICAGO, USA |
| ARCHIVE |
| 60 DAYS AFTER THE RESPONSE DATE |
| RECOVERY ACT FUNDS |
| N |
SET-ASIDE
| PRODUCT SERVICE CODE* |
| H312 |
| NAICS CODE* |
| 561621 |
| CONTRACTING OFFICE ADDRESS |
| Department of Veterans Affairs |
36C252 115 South 84th Street, Suite 101
Milwaukee WI 53214-1476
POINT OF CONTACT*
Contract Specialist Lemke, Justin Justin.Lemke@va.gov 414-844-4800 ext. 40193
PLACE OF PERFORMANCE
| ADDRESS |
| Jesse Brown VA Medical Center |
820 S. Damen Avenue
Chicago IL
| POSTAL CODE |
| 60612-4223 |
| COUNTRY |
| USA |
ADDITIONAL INFORMATION
| AGENCY CONTACT’S EMAIL ADDRESS |
| Justin.Lemke@va.gov |
| EMAIL DESCRIPTION |
| Government Email |
DESCRIPTION
This is not a solicitation for proposals, proposal abstracts, bids, or quotations. The purpose of this notice is to obtain information regarding the availability and capability of all qualified sources to perform Fire and Smoke Door Inspection and Repair Services at Jesse Brown VAMC. Responses to the information requested will assist the Government in determining the appropriate acquisition method.
The Great Lakes Acquisition Center (GLAC) – Milwaukee, WI is soliciting businesses for Fire and Smoke Door Inspection Services at Jesse Brown VAMC on a Base +4 Option Year Contract.
It is understood that all firms submitting a response to this Sources Sought will have an established business in the Fire Alarm Inspection / Testing industry with a minimum of three (3) years consecutive experience in performing these types of services in adherence with NFPA Standards. The firm must also be licensed or capable of obtaining the necessary licensing required to perform these services within the State of Wisconsin.
The following NAICS Code has been identified for this requirement:
561621 - Security Systems Services (except Locksmiths)
Interested firms shall provide an overview of their firm’s capabilities and experience with projects similar in size and scope of this project. Capability statements must include:
a. Company Experience in providing services, to include number of years and any examples of current contracts in place with government or commercial entities;
b. Customer point of contact information for contracts listed in company experience along with a description of services provided under the contract (types of services provided, volume of trips per year, geographic service area covered, etc.);
c. Number of technicians currently employed;
d. Description of the ability to provide immediate emergency access and communication between customers and their personnel 24 hours a day, 7 days a week;
e. Current hours of operation;
f. Examples of Quality Control Programs and Procedures currently utilized by your firm;
g. SAM UEI and DUNS number;
h. Organization Name and Assumed Name/dba (if applicable);
i. Organization Address;
j. Point of Contact (including name, title, addresses, telephone number, fax number, and Email address);
k. Business size under NAICS code 561621 (small business, other than small business, Woman-Owned, etc...);
l. Socio-economic status (If SDVOSB or VOSB – provide SDVOSB/VOSB CVE verification or VIP Profile);
m. GSA contract number (if a GSA contract holder);
n. Current state licensing possessed and a brief overview of that state’s licensing requirements. If not currently licensed in Wisconsin, discuss any lead-times and processes your firm would take to obtain necessary licensing to perform these services in the State of Wisconsin. (All information shall be submitted in Word or PDF format, not to exceed 25 pages, including all attachments.) Firms shall identify whether they are a small business or other than small business in accordance with the size standard for NAICS code 561621. If another NAICS code may be applicable, please identify the NAICS in your capability statement along with your corresponding business size and socio-economic status.
Scope of Work:
Contractors shall provide all tools, materials, components, labor, and supervision to conduct a 15-point NFPA 80-101 inspection/inventory of 585 door openings. See attachments Bldg.40, Bldg. 1A,1B,1C, and Bldg.11A 11B. Small repairs to assets will be completed during inspection. The repairs listed will be conducted on doors requiring these specific repairs to be compliant.
Repairs Include:
· Installation of mutes
· Repairing of small holes in doors/frames
· Door closer adjustments
· Removal of excessive signage
· Removal of material from glazing
· Replacing missing screw(s)
· Installation of hinge filler plates
After the inspection is complete, a comprehensive inspection report must be provided. This report must include a full inventory of all assets, the overall pass/fail of barrier assemblies, and a detailed list of repairs needed to bring any deficient doors into compliance.
Disclaimer and Important Notes: All information must be received no later than Thursday, 01/15/2026 at 10:00 AM (Central Time). Email information to Justin Lemke, Contracting Specialist, at Justin.Lemke@va.gov. The Government will valuate market information to ascertain potential market capacity to provide services consistent in scope and scale with those described in this notice and otherwise anticipated.
Telephone inquiries will not be accepted or returned. BASED ON THE RESPONSES TO THIS SOURCES SOUGHT NOTICE/MARKET RESEARCH, THIS REQUIREMENT MAY BE SET-ASIDE FOR A SPECIFIC SMALL BUSINESS SOCIOECONOMIC CONTRACTING PROGRAM, SMALL BUSINESSES, OR PROCURED THROUGH FULL AND OPEN COMPETITION.
This notice does not obligate the Government to award a contract or otherwise pay for the information provided in response. The Government reserves the right to use information provided by respondents for any purpose deemed necessary and legally appropriate. Any organization responding to this notice should ensure that its response is complete and sufficiently detailed to allow the Government to determine the organization's qualifications to perform the work. Respondents are advised that the Government is under no obligation to acknowledge receipt of the information received or provide feedback to respondents with respect to any information submitted.
Confidentiality: No proprietary, classified, confidential, or sensitive information should be included in your response. The Government reserves the right to use any non-proprietary technical information in any resultant solicitation(s).
| *= Required Field |
| Sources Sought Notice |
Sources Sought Notice
File details come from the government source that posted it. Updated .