H261--Arc Flash Analysis
Closed Solicitation Posted
- Solicitation number
- 36C24223Q1114
- Agency
- Veterans Integrated Service Network 2 Veterans Health Administration, Department of Veterans Affairs
- Responses due
- Set-aside
- Service-Disabled Veteran-Owned Small Business
Opportunity facts
- NAICS code
- 541330 Engineering Services
- Place of performance
- Department of Veterans Affairs Samuel S. Stratton VA Medical Center Albany, New York 12208, United States
Notice details come from SAM.gov. Updated .
About this opportunity
The Federal Contract Opportunity is seeking a contractor to perform an Arc Flash Analysis for the Stratton VA Medical Center in Albany, NY. The analysis will include the entire electrical system, both normal and emergency, and is intended to make the facility electrical systems compliant with VHA Directive 1028 and NFPA 70E. The contract is projected to run from 09/11/2023 through 09/10/2024, with the final report to be completed, submitted, and approved within 147 calendar days after the Notice to Proceed.
Services and products to be provided by the contractor:
- Arc Flash Analysis for the Stratton VA Medical Center.
- Compliance with VHA Directive 1028 and NFPA 70E.
- Site survey work and coordination with the VAMC.
- Submission of 60%, 90%, and final reports, including hard copies and electronic copies.
- Provision of a licensed copy of the software used by the contractor to produce the report, a five-year software update & support contract, and on-site training for eight facility personnel.
Notice text
3 versions
Update #3 · Latest ·
Amendment to include report per question five (5) from questions and answer from previous amendment 0001.
Update #2 ·
Amendment to include Questions and Answers, Price/Cost Schedule, and the revised Combined Synopsis/ Solicitation for Samuel S. Stratton Arch Flash Study.
Update #1 ·
The Contractor shall perform an Arc Flash Analysis for the Stratton VA Medical Center (VAMC), Albany NY. The study shall include the entire electrical system/s (both normal and emergency). It shall begin at the incoming utility electrical service (for the normal system) and at the emergency generators (for the emergency system) and continue through to each branch circuit panelboard, motor control center or motor control panel in each building.
The purpose of this study is to make the facility electrical systems compliant with VHA Directive 1028 and NFPA 70E (2021) which requires an arc flash analysis every five years.
Attachments
| File | Type | Posted |
|---|---|---|
| 26 05 71-3 Coordination Study Addendum II 4-23-19.pdf | ||
| 36C24223Q1114 0002.docx | DOCX document | |
| 36C24223Q1114 S30.pdf | ||
| 36C24223Q1114 0001_1.docx | DOCX document | |
| ARC FLASH STUDY PRICE COST SCHEDULE.xlsx | XLSX spreadsheet | |
| Arc Flashes Analysis Combined Synopsis Solicitation Commercial Products and Commercial Services -REVISED.pdf | ||
| Arc Flash Study Q_A.docx | DOCX document | |
| 36C24223Q1114.docx | DOCX document | |
| Arc Flashes Analysis Combined Synopsis Solicitation Commercial Products and Commercial Services.pdf | ||
| 852.219-75 VA Notice of Limitations on Subcontracting Certificate of Compliance for Services and Construction (JAN 2023).pdf |