Gate-troubleshoot & repair HVAC-bldg 26

Closed Solicitation Posted

This opportunity was awarded. See the award notice from .

Solicitation number
140P4526Q0010
Agency
Responses due
Set-aside
Total Small Business

Opportunity facts

Notice details come from SAM.gov. Updated .

About this opportunity

The National Park Service is seeking contractor services to troubleshoot and repair the HVAC systems serving Building 26 at Gateway National Recreation Area's Sandy Hook Unit in Fort Hancock, New Jersey. The primary scope involves diagnosing and repairing two separate Daikin VRV-IV Heat Pump systems—a 12-ton unit on the first floor and a 14-ton unit on the second floor—that have experienced refrigerant charge failures despite previous repair attempts. Contractors must provide all materials and labor for complete system diagnostics, repair of up to six faulty valves or fittings using brazed connections, pressure and vacuum testing, and recharging with R410A refrigerant (estimated not to exceed 75 pounds total). Evaluation will be based on technical capability and past performance on similar projects completed within the past three years, in addition to price reasonableness. The deadline for proposal submission is March 11, 2026, at 2:00 PM Eastern Daylight Time, with a question submission deadline of March 6, 2026, at 12:00 PM, and site visit completion required by March 4, 2026.

This solicitation is designated as a 100% small business set-aside under NAICS code 238220 (Plumbing, Heating, and Air-Conditioning Contractors) with a size standard of $19 million. No incumbent contractor is identified in the available materials. The estimated contract value is not disclosed in the solicitation documents. Work must commence within two weeks of contract award and be completed within 21 days of notice to proceed, with performance conducted Monday through Friday between 7:00 AM and 5:00 PM, excluding federal holidays. The primary contractor is required to hold all necessary HVAC mechanic licenses and perform a minimum of 51% of the labor. All work will be performed at Building 26 (26 Hudson Road, Fort Hancock, New Jersey 07732) at the Sandy Hook Unit of Gateway National Recreation Area, and the contractor will provide a one-point-of-contact responsible for onsite work, with a five-year warranty required on all repairs completed.

Notice text

5 versions

Update #5 · Latest ·

GATE-TROUBLESHOOT & REPAIR HVAC-BLDG 26
The purpose of this amendment is to respond to questions

Update #4 ·

GATE-TROUBLESHOOT & REPAIR HVAC-BLDG 26
The purpose of this amendment is to attach the revised Statement of Work (SOW)

Update #3 ·

GATE-TROUBLESHOOT & REPAIR HVAC-BLDG 26
The purpose of this amendment is to respond to questions.

Update #2 ·

GATE-TROUBLESHOOT & REPAIR HVAC-BLDG 26
The purpose of this amendment is to attach the revised Statement of Work and extend the due date to March 11, 2026 at 2:00 PM.

Update #1 ·

GATE-TROUBLESHOOT & REPAIR HVAC-BLDG 26

Files

Show all 15

Notice history

Notice Type Posted
Gate-troubleshoot & repair HVAC-bldg 26 Award Award Notice
This notice Latest solicitation Solicitation

Similar open opportunities

Opportunity Agency Set-aside Responses due
USCG Station Lake Worth Inlet HVAC Diagnostic and Repairs Riviera Beach, Florida 33404, United States · NAICS 238220 — Total Small Business
HVAC Unit Replacement NAICS 238220 National Oceanic and Atmospheric Administration Total Small Business
Replace HVAC Rooftop Units at Building 2275 March Air Reserve Base, California 92518, United States · NAICS 238220 Army National Guard No set-aside
Rental of AC Unit with Heaters Portsmouth, Virginia, United States · NAICS 532490 Naval Sea Systems Command No set-aside
J041--White City B249 SE HVAC Repair NAICS 238220 Veterans Integrated Service Network 20 No set-aside

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity

GovTribe for Federal Contractors