About this opportunity

The U.S. Army Corps of Engineers, Portland District seeks to replace aging electrical equipment at the Foster Dam Powerhouse in Sweet Home, Oregon through a firm-fixed-price contract. The solicitation seeks replacement of 4160V switchgear over 40 years old including new vacuum breakers, replacement of 480V double-ended switchgear and station service transformers, new motor control centers, replacement of 480V panels and the DC system including batteries. Proposals will be evaluated on technical and price factors, with award going to the responsible offeror providing the best value. Proposals are due by August 23, 2021.

There is no set-aside designation for this procurement. The primary NAICS code is 238210 and PSC code is O600. Work includes replacement of electrical infrastructure exceeding standard 35-40 year design life with a projected value between $5-10 million. Replacement aims to improve reliability of critical systems over the next 30-40 years at this facility originally constructed in the 1960s.

Notice text

THIS POST IS TO CORRECT THE NOTICE ID TO W9127N21R0060

Foster Dam and Powerhouse was constructed in the 1960s and most of the electrical equipment throughout the facility is over 40 years old. While there does not appear to be a standard expected design life for electrical equipment, the industry standard is 35 to 40 years. Some of the factors that affect the expected design life are equipment loading, maintenance, and environmental factors. As such, most of the electrical equipment in the Foster powerhouse should be considered for replacement. Replacement of the existing air blast main unit breakers; new station service equipment, new station service transformers, and new powerhouse motor control centers are recommended.

The U. S. Army Corps of Engineers (USACE), Portland District, requires a contractor to replace the existing 4160 V switchgear (including the original air blast main unit breakers with vacuum breakers); replace the existing 480 V double ended-switchgear (including new station service transformers); new powerhouse motor control centers; replacement of powerhouse 480 V CQ panels; the DC system (including new station battery); preferred AC equipment; related protection and controls; new wiring for power, protection, controls, annunciation and ancillaries.

Attachments

Notice history

Notices posted for this opportunity, newest first
Notice Type Posted
Foster electrical reliability upgrades Award Award Notice
Foster electrical reliability upgrades This notice · Latest solicitation Solicitation
Foster electrical reliability upgrades Solicitation
Foster electrical reliability upgrades Pre-Solicitation
John Day Turbine Rehabilitation Original Pre-Solicitation

On GovTribe

Work this opportunity on GovTribe

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity