WCF Electrical Substation Upgrade

Open Pre-Solicitation Posted

Solicitation number
2031ZA27R00005
Agency
Responses due
Set-aside
Service-Disabled Veteran-Owned Small Business

Opportunity facts

Place of performance
Fort Worth, Texas 76131, United States

Notice details come from SAM.gov. Updated .

About this opportunity

The Department of the Treasury Bureau of Engraving and Printing (BEP) intends to solicit a design-build Electrical Safety Substation Upgrade Project at its Western Currency Facility under a total set-aside for eligible Service-Disabled Veteran-Owned Small Businesses (SDVOSBs), with the notice response due and the solicitation release both anticipated on December 9, 2026. The procurement is Solicitation Number 2031ZA27R00005, coded NAICS 238210 (Electrical Contractors and Other Wiring Installation Contractors) and PSC Z2AZ. Work is performed at 9000 Blue Mound Road, Fort Worth, Texas 76131.

The scope upgrades existing electrical distribution systems within Substations I, II, III, and IV. It includes replacing and retrofitting existing circuit breakers with Schneider Electric MasterPact circuit breakers, installing associated electrical components, ground fault protection, remote breaker operating capabilities, and energy reduction maintenance settings. The contractor furnishes design and engineering services, labor, materials, equipment, and supervision. It must also integrate new equipment with existing facility control systems, perform arc flash and electrical coordination studies, conduct testing and commissioning, and provide updated electrical drawings and documentation, in accordance with the Statement of Work, applicable codes, and industry standards.

The estimated magnitude of construction is between $1 million and $5 million. The anticipated proposal due date is January 11, 2027. The solicitation and attachments will be posted electronically on SAM.gov.

Notice text

Presolicitation Notice – WCF Electrical Safety Substation Upgrade Project

Solicitation Number: 2031ZA27R00005

The Bureau of Engraving and Printing (BEP) intends to issue a solicitation for a design-build Electrical Safety Substation Upgrade Project at the Western Currency Facility (WCF), located at 9000 Blue Mound Road, Fort Worth, TX 76131.

The project involves upgrading the existing electrical distribution systems within Substations I, II, III, and IV. The anticipated scope includes the replacement and retrofitting of existing circuit breakers with Schneider Electric MasterPact circuit breakers, installation of associated electrical components, ground fault protection, remote breaker operating capabilities, and energy reduction maintenance settings.

The contractor will also be responsible for integrating the new equipment with existing facility control systems, performing arc flash and electrical coordination studies, conducting required testing and commissioning, and providing updated electrical drawings and documentation.

The contractor shall furnish all necessary design and engineering services, labor, materials, equipment, supervision, and associated resources required to complete the project in accordance with the Statement of Work (SOW), applicable codes, and industry standards.

This acquisition will be conducted as a total set-aside for eligible Service-Disabled Veteran-Owned Small Businesses (SDVOSBs) under NAICS code 238210, Electrical Contractors and Other Wiring Installation Contractors.

Estimated Magnitude of Construction: Between $1,000,000 and $5,000,000.

Anticipated Solicitation Release Date: December 9, 2026

Anticipated Proposal Due Date: January 11, 2027

The solicitation and all applicable attachments will be made available electronically through SAM.gov. Interested contractors are encouraged to monitor SAM.gov for the official solicitation and any subsequent updates.

Similar open opportunities

Opportunity Agency Set-aside Responses due
Patio Renovation and Sun Sail Installation Fort Worth, Texas 76131, United States · NAICS 238990 Bureau of Engraving and Printing Total Small Business
Z1DA--Project No. 583-22-106- Replace Electrical Panels & Expand Distribution. NAICS 238210 Veterans Integrated Service Network 10 No set-aside
Z1DA--642-22-104 | Upgrade Substation Building 2 Phase 1 for Philadelphia VAMC Pennsylvania 19104, United States · NAICS 236220 Veterans Integrated Service Network 4 Service-Disabled Veteran-Owned Small Business
H259--Essential Electrical System (EES) Switch Gear Testing Department of Veteran Affairs San Diego VA Medical Center San Diego CA 92161, United States · NAICS 811310 Veterans Integrated Service Network 22 Service-Disabled Veteran-Owned Small Business
Request for Information/Market Intelligence Notice: Repair Electrical Distribution System Switchgear Stations & Addition of Redundancy Cable Use of Progressive Design Build (PDB) with Other Transaction Authority (OTA) Bolling AFB, District of Columbia 20032, United States · NAICS 238210 District Washington No set-aside

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity