Fire Rappelling Anchor Inspection
Closed Solicitation Posted
This opportunity was awarded. See the award notice from .
- Solicitation number
- FA462025QA811
- Agency
-
Air Mobility Command
Air Force, Department of Defense
- Responses due
- Set-aside
- Total Small Business
Opportunity facts
- NAICS code
- 541350 Building Inspection Services
- Place of performance
- Fairchild Air Force Base, Washington 99011, United States
Notice details come from SAM.gov. Updated .
About this opportunity
The 92d Contracting Squadron at Fairchild Air Force Base is seeking Fire Rappelling Anchor Inspection Services under solicitation FA462025QA811. The Department of the Air Force Air Mobility Command requires non-destructive testing of four rappelling eyelets at the Fire Training Site, Facility 1550, including pull testing with a 2,250-pound test force and visual inspection for damage such as cracks or deformation. Contractors must provide all necessary tools, equipment, labor, and testing equipment to perform the inspection and deliver a comprehensive testing report with results, deficiencies, recommended corrective actions, and photographic documentation. The evaluation will be based on price and Supplier Performance Risk System (SPRS) assessment. Following two amendments, the final quote submission deadline is July 30, 2025, at 10:00 AM PDT, with a site visit having been scheduled for July 22, 2025, and questions due by July 23, 2025.
This procurement is designated as a 100% Total Small Business Set-Aside under NAICS code 541350 (Building Inspection Services) with an $11.5 million size standard. No incumbent contractors or specific award values are mentioned in the available documentation, though the contract structure will be a single Firm Fixed-Price commercial arrangement. The work must be completed within 60 days after contract award and performed during standard business hours of 0700-1630, Monday through Friday, excluding federal holidays. All services will be performed at Fairchild Air Force Base in Washington state, specifically at Facility 1550. Contractors must comply with NFPA 1402 and OSHA standards, maintain proper security clearances for base access, and adhere to strict photography restrictions requiring prior authorization from the 92 ARW Public Affairs Office.
Notice text
3 versions
Update #3 · Latest ·
Amendment 0001 - 17 July 2025
- Add attachment Amendment 0001
- Add attachment Attachment 2 - Amend 1 - WD 2015-5537_Revision 26_8 Jul 25
Amendment 0002 - 28 July 2025
- Extend the date and time quotes are due to 30 July 2025 at 10:00 AM PDT
- Add Attachment Amendment 0002
- Add Attachment 3 - Amendment 0002 - Test Point Photos
The 92d Contracting Squadron is issuing this combined synopsis/solicitation as a Request for Quote under number FA462025QA811 for Fire Rappelling Anchor Inspection Services and shall be used to reference any written quote provided under this RFQ. This solicitation is a 100% Total Small Business Set Aside.
Update #2 ·
Amendment 0001 - 17 July 2025
- Add attachment Amendment 0001
- Add attachment Attachment 2 - Amend 1 - WD 2015-5537_Revision 26_8 Jul 25
The 92d Contracting Squadron is issuing this combined synopsis/solicitation as a Request for Quote under number FA462025QA811 for Fire Rappelling Anchor Inspection Services and shall be used to reference any written quote provided under this RFQ. This solicitation is a 100% Total Small Business Set Aside.
Update #1 ·
The 92d Contracting Squadron is issuing this combined synopsis/solicitation as a Request for Quote under number FA462025QA811 for Fire Rappelling Anchor Inspection Services and shall be used to reference any written quote provided under this RFQ. This solicitation is a 100% Total Small Business Set Aside.
Files
Notice history
| Notice | Type | Posted |
|---|---|---|
| Fire Rappelling Anchor Inspection | Award Notice | |
| This notice | Solicitation |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| Inspection of Fire Extinguishers and Suppression Systems for AMXG at Hill AFB, Utah | Air Force Sustainment Center | Total Small Business | |
| Fire Alarm/Suppression Inspection, Testing, and Maintenance | Air Force Research Laboratory | No set-aside | |
| Fire apparatus intercom system uplift and installation | Air Force Test Center | Total Small Business | |
| Vertical Transportation Equipment (VTE) Maintenance, Repair, & Inspection Services | Air Mobility Command | Total Small Business | |
| Airfield Blast Shield | Global Strike Command | Total Small Business |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity