Fire Alarm Control Panel Replacement Project (FACPR)
Open Solicitation Posted
- Solicitation number
- 2026-PTG-FACPR
- Agency
-
Department of Energy
- Responses due
- Set-aside
- No set-aside
Opportunity facts
- NAICS code
- 238210 Electrical Contractors and Other Wiring Installation Contractors
- PSC
- 1230 Fire Control Systems, Complete
- Place of performance
- California 94720, United States
- Points of contact
Notice details come from SAM.gov. Updated .
About this opportunity
The University of California, managing Lawrence Berkeley National Laboratory for the Department of Energy, requests proposals for a firm-fixed-price design-build subcontract to replace fire alarm control panels in Buildings 2, 26, 33, and 76 under RFP 2026-PTG-FACPR, with proposals due January 8, 2027 at 5:00 PM Pacific Time. The procurement uses no set-aside, so small businesses compete directly or as lower-tier subcontractors. A mandatory pre-proposal conference and on-site inspection runs December 3, 2026, 9:30 to 11:30 AM Pacific, and firms not attending will not be evaluated.
Place of performance is Berkeley, California 94720 (One Cyclotron Road). The scope covers design, engineering, procurement, installation, changeover, and commissioning to replace obsolete Siemens System 3 panels and legacy backup batteries with Siemens Desigo equipment, with no substitutions permitted. Annunciation and notification devices are not replaced, and StarLink cabinets are relocated only as needed to follow the panels.
Offerors must hold an active California contractor's license and have access to a California-licensed Professional Engineer as Engineer of Record, specifically a California-licensed Fire Protection Engineer to stamp fire alarm drawings. Performance and payment bonds are each required at 100% of the subcontract price from a Treasury Circular 570 surety. Safety is a mandatory qualification factor with no acceptable "No" answer or missing documentation, including an Experience Modification Rate not exceeding 1.00 for three prior premium years. Past performance requires three references for similar projects of approximately $500,000 or more completed within ten years, with emphasis on occupied facilities.
Design submittals at 50%, 75%, 95%, and 100% are due 8, 12, 16, and 19 weeks after notice to proceed, and overall completion is required by March 7, 2028. The estimated subcontract value is $700,000 to $1,400,000, fully funded at award. Pricing is a lump sum per building split across design, construction, and Siemens lines, and it must include bonds, insurance, prevailing wages, after-hours impairment work, and commissioning. Davis-Bacon wages apply under General Wage Decision CA20260018 Mod 8.
Evaluation uses tradeoff best-value source selection with technical factors weighted more heavily than price. The four technical factors are Safety, Relevant Past Performance, Technical Approach/Schedule/Management, and Key Personnel/Organizational Capability, with a combined 20-page technical volume limit plus resumes. No incumbent is named.
Notice text
The University of California, Lawrence Berkeley National Laboratory requests proposals for design-build services for the design and construction of the Fire Alarm Control Panel Replacement Project ("FACPR" or "the Project").
The Project covers Buildings 2, 26, 33, and 76. Under this subcontract, the Design-Build Subcontractor will provide all professional design, engineering, procurement, installation, changeover, and commissioning services needed to replace the fire alarm control panels and backup battery systems.
The Siemens Desigo system has been selected as LBNL's campus-standard fire alarm platform for this Project, no substitutions will be considered. Using one common platform supports compatibility with the existing mix of field devices, loops, and conventional circuits, and simplifies maintenance, training, and future parts availability across the site.
The existing fire alarm wiring in the four buildings will generally remain in place. This Project replaces the central control equipment, not the complete building fire alarm systems. Fire alarm annunciation and notification devices and the StarLink cabinets themselves are not being replaced under this Project; StarLink cabinets will be relocated only as needed to follow the panels.
Files
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| Northern California Area Office (NCAO) Fire Alarm | — | Service-Disabled Veteran-Owned Small Business | |
| USCG tracen petaluma siemens fire alarm system repair | — | Total Small Business | |
| Fire Alarm Panel Replacement(s) | Bureau of Reclamation | No set-aside |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity