Notice text

5 versions

Update #5 · Latest ·

Amendment 0004

NAVFAC MIDLANT FEAD Cherry Point North Carolina Request for Proposals (RFP) for Equipment Operation and Maintenance for the Central Energy Building, Naval Health Clinic, Marine Corps Air Station, Cherry Point NC  

The work includes but is not limited to operate and maintain the Central Energy Plant 24 hours per day seven days a week. The Contractor shall provide all labor, management, supervision, tools, material, and equipment to continuously operate, maintain and repair the Chiller Plant and Distribution System, the Steam and Hot Water Generation Plant, the Steam and Hot Water Distribution Systems, the Condensate Return System, and the Compressed Air Plant for Control Air and Medical and Dental Air and Vacuum Systems located at the Central Energy Building. The Contractor is responsible for all equipment, controls and piping systems located inside the facility.

Work typically will include operation, management and maintenance of utility chilled water and air conditioning systems, utility steam and hot water systems, and air compressors for control air, medical and dental air and medical vacuum systems. An integrated maintenance plan for dynamic and static equipment and systems will be included in this work. The Contractor is responsible for maintaining all systems located in the Central Energy Building up to the Firm Fixed Price Limit per equipment or component per occurrence. Additionally major repair work, consisting of component replacement, equipment replacement and new equipment installation exceeding the integrated maintenance plan (IMP) limit of liability will be ordered under the IDIQ portion of the Contract. 

The Contractor shall provide sufficient material, labor, equipment, supervision, and transportation to fulfill all requirements of the contract in accordance with the timeliness standards as set forth by the Government. The proposed contractor’s work plan shall comply with all applicable Federal, State, and Local Regulations. Additional requirements will be provided in the solicitation.

Update #4 ·

Site Visit Log

NAVFAC MIDLANT FEAD Cherry Point North Carolina Request for Proposals (RFP) for Equipment Operation and Maintenance for the Central Energy Building, Naval Health Clinic, Marine Corps Air Station, Cherry Point NC  

The work includes but is not limited to operate and maintain the Central Energy Plant 24 hours per day seven days a week. The Contractor shall provide all labor, management, supervision, tools, material, and equipment to continuously operate, maintain and repair the Chiller Plant and Distribution System, the Steam and Hot Water Generation Plant, the Steam and Hot Water Distribution Systems, the Condensate Return System, and the Compressed Air Plant for Control Air and Medical and Dental Air and Vacuum Systems located at the Central Energy Building. The Contractor is responsible for all equipment, controls and piping systems located inside the facility.

Work typically will include operation, management and maintenance of utility chilled water and air conditioning systems, utility steam and hot water systems, and air compressors for control air, medical and dental air and medical vacuum systems. An integrated maintenance plan for dynamic and static equipment and systems will be included in this work. The Contractor is responsible for maintaining all systems located in the Central Energy Building up to the Firm Fixed Price Limit per equipment or component per occurrence. Additionally major repair work, consisting of component replacement, equipment replacement and new equipment installation exceeding the integrated maintenance plan (IMP) limit of liability will be ordered under the IDIQ portion of the Contract. 

The Contractor shall provide sufficient material, labor, equipment, supervision, and transportation to fulfill all requirements of the contract in accordance with the timeliness standards as set forth by the Government. The proposed contractor’s work plan shall comply with all applicable Federal, State, and Local Regulations. Additional requirements will be provided in the solicitation.

Update #3 ·

Amendment 0003 - Responses to Questions.

NAVFAC MIDLANT FEAD Cherry Point North Carolina Request for Proposals (RFP) for Equipment Operation and Maintenance for the Central Energy Building, Naval Health Clinic, Marine Corps Air Station, Cherry Point NC  

The work includes but is not limited to operate and maintain the Central Energy Plant 24 hours per day seven days a week. The Contractor shall provide all labor, management, supervision, tools, material, and equipment to continuously operate, maintain and repair the Chiller Plant and Distribution System, the Steam and Hot Water Generation Plant, the Steam and Hot Water Distribution Systems, the Condensate Return System, and the Compressed Air Plant for Control Air and Medical and Dental Air and Vacuum Systems located at the Central Energy Building. The Contractor is responsible for all equipment, controls and piping systems located inside the facility.

Work typically will include operation, management and maintenance of utility chilled water and air conditioning systems, utility steam and hot water systems, and air compressors for control air, medical and dental air and medical vacuum systems. An integrated maintenance plan for dynamic and static equipment and systems will be included in this work. The Contractor is responsible for maintaining all systems located in the Central Energy Building up to the Firm Fixed Price Limit per equipment or component per occurrence. Additionally major repair work, consisting of component replacement, equipment replacement and new equipment installation exceeding the integrated maintenance plan (IMP) limit of liability will be ordered under the IDIQ portion of the Contract. 

The Contractor shall provide sufficient material, labor, equipment, supervision, and transportation to fulfill all requirements of the contract in accordance with the timeliness standards as set forth by the Government. The proposed contractor’s work plan shall comply with all applicable Federal, State, and Local Regulations. Additional requirements will be provided in the solicitation.

Update #2 ·

Amendment 0002

NAVFAC MIDLANT FEAD Cherry Point North Carolina Request for Proposals (RFP) for Equipment Operation and Maintenance for the Central Energy Building, Naval Health Clinic, Marine Corps Air Station, Cherry Point NC  

The work includes but is not limited to operate and maintain the Central Energy Plant 24 hours per day seven days a week. The Contractor shall provide all labor, management, supervision, tools, material, and equipment to continuously operate, maintain and repair the Chiller Plant and Distribution System, the Steam and Hot Water Generation Plant, the Steam and Hot Water Distribution Systems, the Condensate Return System, and the Compressed Air Plant for Control Air and Medical and Dental Air and Vacuum Systems located at the Central Energy Building. The Contractor is responsible for all equipment, controls and piping systems located inside the facility.

Work typically will include operation, management and maintenance of utility chilled water and air conditioning systems, utility steam and hot water systems, and air compressors for control air, medical and dental air and medical vacuum systems. An integrated maintenance plan for dynamic and static equipment and systems will be included in this work. The Contractor is responsible for maintaining all systems located in the Central Energy Building up to the Firm Fixed Price Limit per equipment or component per occurrence. Additionally major repair work, consisting of component replacement, equipment replacement and new equipment installation exceeding the integrated maintenance plan (IMP) limit of liability will be ordered under the IDIQ portion of the Contract. 

The Contractor shall provide sufficient material, labor, equipment, supervision, and transportation to fulfill all requirements of the contract in accordance with the timeliness standards as set forth by the Government. The proposed contractor’s work plan shall comply with all applicable Federal, State, and Local Regulations. Additional requirements will be provided in the solicitation.

Update #1 ·

NAVFAC MIDLANT FEAD Cherry Point North Carolina Request for Proposals (RFP) for Equipment Operation and Maintenance for the Central Energy Building, Naval Health Clinic, Marine Corps Air Station, Cherry Point NC  

The work includes but is not limited to operate and maintain the Central Energy Plant 24 hours per day seven days a week. The Contractor shall provide all labor, management, supervision, tools, material, and equipment to continuously operate, maintain and repair the Chiller Plant and Distribution System, the Steam and Hot Water Generation Plant, the Steam and Hot Water Distribution Systems, the Condensate Return System, and the Compressed Air Plant for Control Air and Medical and Dental Air and Vacuum Systems located at the Central Energy Building. The Contractor is responsible for all equipment, controls and piping systems located inside the facility.

Work typically will include operation, management and maintenance of utility chilled water and air conditioning systems, utility steam and hot water systems, and air compressors for control air, medical and dental air and medical vacuum systems. An integrated maintenance plan for dynamic and static equipment and systems will be included in this work. The Contractor is responsible for maintaining all systems located in the Central Energy Building up to the Firm Fixed Price Limit per equipment or component per occurrence. Additionally major repair work, consisting of component replacement, equipment replacement and new equipment installation exceeding the integrated maintenance plan (IMP) limit of liability will be ordered under the IDIQ portion of the Contract. 

The Contractor shall provide sufficient material, labor, equipment, supervision, and transportation to fulfill all requirements of the contract in accordance with the timeliness standards as set forth by the Government. The proposed contractor’s work plan shall comply with all applicable Federal, State, and Local Regulations. Additional requirements will be provided in the solicitation.

Files

File Type Posted
Amendment 0004.pdf PDF
SITE VISIT LOG 21R0036.pdf PDF
Amendment 0003.pdf PDF
Amend 0003 ELINs Cherry Point.xlsx XLSX spreadsheet
Amendment 0002 N4008521R0036.pdf PDF
J-0200000-07 Spill Plan.pdf PDF
NAVY SHORE BOILER GUIDE.pdf PDF
Amendment 0001 N4008521R0036 SOLICITATION.pdf PDF
J-0200000-05-05Leak Rate Calculations.pdf PDF
J-1607000-03.jpg JPG image
J-1605000-03.jpg JPG image
Solicitation N4008521R0036.pdf PDF
J-1608000-03.jpg JPG image
NAVFAC Form PPQ-0.docx DOCX document
ELINs Cherry Point.xlsx XLSX spreadsheet
J-0200000-07 Installation Spill Control Plan.pdf PDF
CORPORATE EXPERIENCE PROJECT DATA SHEET.docx DOCX document
Show all 17

Notice history

Notice Type Posted
This notice Latest solicitation Solicitation
Equipment Operation and Maintenance for the Central Energy Building, Naval Health Clinic, MCAS Cherry Point NC Pre-Solicitation
Equipment Operation and Maintenance for the Central Energy Building, Naval Health Clinic, MCAS Cherry Point NC Original Pre-Solicitation

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity

GovTribe for Federal Contractors