Deva- structural fire systems ITM

Closed Solicitation Posted

Solicitation number
140P8126Q0046
Agency
Pacific West Region National Park Service, Department of the Interior
Responses due
Set-aside
No set-aside

Opportunity facts

NAICS code
238220 Plumbing, Heating, and Air-Conditioning Contractors
PSC
S202 Housekeeping- Fire Protection
Points of contact

Notice details come from SAM.gov. Updated .

About this opportunity

The National Park Service Pacific West Region seeks inspection, testing, and maintenance of structural fire systems at Death Valley National Park in California, with proposals due September 4, 2026, and questions due August 26, 2026. This is an unrestricted procurement using full and open competition with no set-aside.

Place of performance is Death Valley National Park, California (Cow Creek Service Road), with administrative oversight by NPS Power at Lake Mabo in Boulder City, Nevada. The work encompasses fire alarm signaling systems (18 systems), commercial wet and dry pipe sprinkler systems (19 systems with 905 sprinkler heads across 15 facilities), and residential wet pipe sprinkler systems (37 systems across 21 locations). The contractor must perform inspections and testing per NFPA 13, 13D, 13R, 14, 15, 20, 22, 24, 25, 70, 72, 80, 90A, 96, 101, 110, and 750, and applicable International Building, Mechanical, Plumbing, and Fire Codes. All work must be completed within 120 days of order receipt, with inspections finished by day 90. The period of performance runs from September 18, 2026, to January 15, 2027.

The award is a single firm fixed price purchase order. NAICS code is 238220, Plumbing, Heating, and Air-Conditioning Contractors; PSC is S202, Housekeeping-Fire Protection. Service Contract Labor Standards apply with a wage determination of $28.51 per hour plus 30% fringe benefits for WG 6 Fire Alarm System Mechanics. Key personnel requirements are pass/fail: a job site superintendent employed by the prime contractor and a certified inspector holding all required certifications with three years' continuous inspection and testing experience within California. Evaluation criteria are price, relevant prior experience (three project references from the past five years), past performance verification, and key personnel qualifications. Amendment 0001, issued August 28, added sprinkler head count detail and requires acknowledgment prior to submission deadline.

Notice text

Structural fire systems inspection, testing and maintenance for Death Valley National Park.

Attachments

Show all 11

On GovTribe

Work this opportunity on GovTribe

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity