Camp Blanding, FL Tank Inspection
Closed Solicitation Posted
- Solicitation number
- W9128F25Q0030
- Agency
- ENDIST Omaha US Army Corps of Engineers, Department of Defense
- Responses due
- Set-aside
- No set-aside
Opportunity facts
- NAICS code
- 541990 All Other Professional, Scientific, and Technical Services
- Place of performance
- Florida 32091, United States
- Points of contact
-
- Brent Bertrand brent.d.bertrand@usace.army.mil (402) 995-2622
- Minhthu Vu minhthu.t.vu@usace.army.mil (402) 995-2892
Notice details come from SAM.gov. Updated .
About this opportunity
The U.S. Army Corps of Engineers Engineering District Omaha is seeking a contractor to perform comprehensive tank inspection services at Camp Blanding, Florida. The solicitation requires conducting Steel Tank Institute (STI) external and internal inspections on three 10,000-gallon jet fuel storage tanks, including fuel disposal, tank cleaning, and manway seal replacement. Contractors must provide strapping charts accurate to 1/16th of an inch and submit detailed project documentation, including a Project Inspection Management Plan within 15 days of award and draft inspection reports within 28 days of field inspection. Technical proposals must include inspector certification, a one-page resume, and three references demonstrating experience in fuel disposal, tank cleaning, and STI inspections. The proposal must be submitted electronically as a single PDF not exceeding 5 pages by February 7, 2025, at 2:00 PM, with questions required to be submitted no later than 7 days before the proposal due date.
The contract is a 100% 8(a) set-aside under NAICS code 541990 with a size standard of $19.5 million. The tanks to be inspected are identified as Facilities T3652, T3653, and T3654, each manufactured in 1994 and located at Kingsley Lake, FL 32091. The period of performance will be 180 days after award, with the work to be executed as a Firm Fixed Price contract. Each tank requires disposal of up to 50 gallons of remaining fuel and comprehensive inspection in accordance with STI SP001 standards. While specific budget details are not disclosed, the contract involves identical services for three tanks, with each tank requiring a kick-off meeting, fuel disposal, cleaning, strapping chart creation, manway seal replacement, and comprehensive internal and external inspections. The installation will provide electricity and water at no cost, and contractors must coordinate with base personnel for site access and safety compliance.
Notice text
Conduct STI with Strapping Charts inspection at Camp Blanding, FL to inspect facilities in accordance with all laws standards, federal regulations, as well as any state and local regulations and guidelines. This service entails disposal of remaining fuel, tank cleaning, providing strapping charts to 1/16th of an inch, conducting an internal inspection, replacing manway seals, and providing an aboveground storage tank (STI) External Inspection on the tank(s) listed in Attachment B.
STI External Inspection Facility #T3652 Tank 1
STI External Inspection Facility #T3653 Tank 2
STI External Inspection Facility #T3654 Tank 3