B825 Chiller and Boiler Repair
Closed Pre-Solicitation Posted
Not the latest version. See the latest solicitation from .
- Solicitation number
- FA480325B0004
- Agency
-
Air Combat Command
Air Force, Department of Defense
- Responses due
- Set-aside
- Total Small Business
Opportunity facts
- NAICS code
- 238220 Plumbing, Heating, and Air-Conditioning Contractors
- Place of performance
- Shaw AFB, South Carolina 29152, United States
Notice details come from SAM.gov. Updated .
About this opportunity
The Department of the Air Force Air Combat Command is seeking a small business contractor to replace chillers and a boiler at Building 825 on Shaw Air Force Base. The project involves installing government-furnished 20-ton and 80-ton chillers and a new 750 BTU/HR Riello boiler, which will require demolishing existing equipment, upgrading electrical components, and integrating new systems with existing DDC controls. Contractors must provide temporary heating/cooling for the Base Defense Operations Center during work and follow Shaw AFB Design Standards. The pre-solicitation notice indicates a total project timeline of 126 calendar days, including 21 days for material submittals, 90 days for construction, and 15 days for closeout. While specific evaluation criteria are not detailed, contractors will need to demonstrate compliance with extensive environmental provisions, including hazardous material management, waste handling, and refrigerant recovery protocols.
The opportunity is set aside exclusively for small businesses in the Plumbing, Heating, and Air-Conditioning Contractors (NAICS 238220) category. The project requires contractors to have certified technicians for refrigerant handling and the ability to provide comprehensive documentation, including daily RAKEN-format reports with photographic evidence of work progress. Contractors must also submit detailed environmental documentation, such as hazardous material worksheets, waste tracking forms, and monthly usage reports. The chillers have already been purchased under a prior contract and will be provided as government-furnished equipment. While no specific budget range is mentioned, the complexity of the project—which includes precise technical requirements like measuring chilled water flow rates, modifying concrete pads, and insulating new piping—suggests a substantial investment in mechanical system upgrades.
Notice text
***This is a Presolicitation Notice. The Solicitation Date release is TBD. Site Visit Date/Time, Questions Due Date/Time and Solicitation Close Date/Time will be posted with actual Solicitation.***
The purpose of this requirement is to replace the chillers and boiler at building 825 in accordance with the Statement of Work, dated 5 November 2024. The replacement chiller have been purchased on a prior contract and will be supplied as government furnished equipment.
Files
Notice history
| Notice | Type | Posted |
|---|---|---|
| VLSB 26-0011 Building 825 Chiller and Boiler Repair | Solicitation | |
| This notice | Pre-Solicitation | |
| B825 Chiller and Boiler Repair | Pre-Solicitation |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| Z2NZ--Turn Key Chiller Equipment (Purchase and Install) | Veterans Integrated Service Network 16 | Service-Disabled Veteran-Owned Small Business | |
| Cooling Tower, Roofing, and Structural Construction | Bureau of Engraving and Printing | Total Small Business | |
| High Temp Hot Water Distribution System and Heat Plant Suite of Repairs to the US Air Force Academy COLORADO | ENDIST Omaha | No set-aside | |
| Repair Naval Reserve Training Facility B3370 | Air Mobility Command | Total Small Business | |
| FCI mckean camp admin air handling unit & installation | Federal Correctional Institution Mckean | Total Small Business |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity