Area of Interest (AoI) – FM200 System Inspection and Repairs (CSO-W911KF25SC002)
Closed Special Notice Posted
- Solicitation number
- W911KF25SC002-AoI0007
- Agency
-
ACC Warren
Army Contracting Command, Department of Defense
- Responses due
- Set-aside
- No set-aside
Opportunity facts
- Place of performance
- Anniston, Alabama 36201, United States
Notice details come from SAM.gov. Updated .
About this opportunity
Army Contracting Command - Anniston Army Depot issued an Area of Interest on April 20, 2026, soliciting semiannual inspection, testing, maintenance, and repair services for fire suppression systems at Anniston Army Depot, with responses due by May 20, 2026 at 4:00 PM CDT. The resulting contract will be one base year plus four option years.
The scope spans 16 buildings across three system types: Kitchen Hood wet chemical systems in Buildings 47, 78, 141, and 1500; FM-200 Clean Agent systems in Buildings 52, 53, 79, 96, 97, 362, 363, and 513; and HFC-227/CO2 production systems in Buildings 128, 410, 474, and 475. All work must comply with NFPA standards 12, 17A, 72, 96, and 2001, and includes functional testing of detection and alarm devices, visual inspection of cylinders and piping, cylinder weight and pressure verification, hydro-testing, detector cleaning, and battery backup testing. Five-year inspections must be conducted in the first year of contract award.
Contractor personnel must hold current NICET Level I certification (minimum one supervisor as NICET Level III) and be licensed and experienced with Fike, Ansul, Notifier, and Pyro-Chem systems. A mandatory pre-work site visit is required. Repairs are billed as Firm Fixed Price under an annual not-to-exceed budget; parts exceeding $500 require Contracting Officer approval. Emergency work has a separate not-to-exceed budget with 24-hour response and 48-hour completion requirements. Offerors must be SAM.gov-registered and submit written solutions including Rough Order of Magnitude pricing; questions are due by May 4, 2026.
Notice text
ACC-ANAD is seeking solutions for semi‑annual inspection, testing, maintenance, and repair of Clean Agent systems (FM‑200/HFC‑227), Carbon Dioxide (CO2) systems, and Kitchen Hood fire extinguishing systems at Anniston Army Depot (ANAD). The resulting contract will include one base year plus four option years.
Interested parties should review the attachments and the full CSO (W911KF25SC002) posting on SAM.gov for submission and evaluation procedures.
ACC-ANAD is not obligated to extend a request for proposal or make an award as a result of this CSO AoI; all awards are subject to the availability of funds and successful negotiations. This CSO AoI is not an authorization to begin performance, and in no way obligates the Government for any costs incurred by the Offeror associated with developing a Response. Prior to commencement of any activities associated with performance under this CSO AoI, the Government will issue a written directive or contractual document signed by the Contracting Officer with appropriate consideration established. ACC-ANAD reserves the right to modify the requirements of this CSO AoI.