ADAL Corrosion Control Facility
Closed Solicitation Posted
This opportunity was awarded. See the award notice from .
- Solicitation number
- W50S9525BA001
- Agency
- Army National Guard Department of the Army, Department of Defense
- Responses due
- Set-aside
- Total Small Business
Opportunity facts
- NAICS code
- 236220 Commercial and Institutional Building Construction
- Place of performance
- McEntire JNGB1325 South Carolina Rd.Eastover SC 29044 29044
- Points of contact
-
- Jonathan Bailey jonathan.bailey.28@us.af.mil (803) 647-8571
- David Viers david.viers@us.af.mil (803) 647-8387
Notice details come from SAM.gov. Updated .
About this opportunity
The Department of the Army National Guard is seeking construction services to renovate and enlarge a corrosion control facility at McEntire Joint National Guard Base in Eastover, South Carolina. The project involves comprehensive facility modifications including the addition of new construction architecturally compatible with the existing building, interior space reconfiguration, mechanical and electrical system upgrades, latrine modifications, HVAC system replacements, improved electrical distribution systems, and roof system replacements to support 24 F-16 aircraft operations. Contractors must provide all necessary plant, labor, transportation, materials, tools, equipment, and supervision using conventional design and construction methods. The government will award the contract to the responsible bidder offering the most advantageous bid based solely on price evaluation criteria. The solicitation has undergone two amendments, with the bid due date extended to June 9, 2025 at 2:00 PM EST, and additional attachments provided including questions and answers, hazardous material surveys, and hazard abatement plans.
This opportunity is designated as a Total Small Business set-aside under NAICS code 236220 for Commercial and Institutional Building Construction. The project value is estimated between $5,000,000 and $10,000,000, requiring bid bonds of 20% or up to $3 million, along with performance and payment bonds. The contract performance period is 450-480 calendar days, with work beginning 30 calendar days after notice to proceed. Multiple companies attended the pre-bid conference on May 14, 2025, including Pyramid Contracting, NASCO, The Eylim Company, AVM Contractors, Parnell Contracting, Harris Integrated, and SAC Services. The work location is at 1325 S Carolina Road, Eastover, South Carolina, and involves significant hazardous material considerations including PCB-containing ballasts, mercury-containing fluorescent tubes, underground storage tanks, and lead-based paint requiring specialized handling and disposal procedures.
Notice text
5 versions
Update #5 · Latest ·
*THIS IS AN ADMINISTRATIVE ACTION ONLY. BIDS ARE NOT BEING ACCEPTED AND THE INFORMATION CONTAINED IN THIS OPPORTUNITY TO INCLUDE THE OFFICIAL BID TABULATION REMAIN UNCHANGED*
Public display certified Bid Abstract and Bid Opening Attendance Roster by AttachmentAMENDMENT 0002: Provide the following Attachments: Questions and Answers (Atch 3), Hazardous Material Survey (Atch 4), and AF Form 3, Hazard Abatement Plan (Atch 5).AMENDMENT 0001: Extend the bid due date from 30 May 2025 to 06 June 2025 at 2 PM EST. Services, non-personal, to provide all plant, labor, transportation, materials, tools, equipment, appliances, and supervision necessary to renovate and enlarge a corrosion control facility by utilizing conventional design and construction methods at McEntire JNGB. The scope of this project will consist of a properly sited and configured Corrosion Control Facility supporting 24 PAA F-16 aircraft. It will include facility addition of like construction, all architecturally compatible with existing facility. It also includes reconfigured existing interior spaces, mechanical, electrical systems and modified latrines, replaced heating, ventilation and air conditioning (HVAC) systems, improved electrical distribution system, and replaced roof systems.
Update #4 ·
Public display certified Bid Abstract and Bid Opening Attendance Roster by AttachmentAMENDMENT 0002: Provide the following Attachments: Questions and Answers (Atch 3), Hazardous Material Survey (Atch 4), and AF Form 3, Hazard Abatement Plan (Atch 5).AMENDMENT 0001: Extend the bid due date from 30 May 2025 to 06 June 2025 at 2 PM EST. Services, non-personal, to provide all plant, labor, transportation, materials, tools, equipment, appliances, and supervision necessary to renovate and enlarge a corrosion control facility by utilizing conventional design and construction methods at McEntire JNGB. The scope of this project will consist of a properly sited and configured Corrosion Control Facility supporting 24 PAA F-16 aircraft. It will include facility addition of like construction, all architecturally compatible with existing facility. It also includes reconfigured existing interior spaces, mechanical, electrical systems and modified latrines, replaced heating, ventilation and air conditioning (HVAC) systems, improved electrical distribution system, and replaced roof systems.
Update #3 ·
AMENDMENT 0002: Provide the following Attachments: Questions and Answers (Atch 3), Hazardous Material Survey (Atch 4), and AF Form 3, Hazard Abatement Plan (Atch 5).
AMENDMENT 0001: Extend the bid due date from 30 May 2025 to 06 June 2025 at 2 PM EST.
Services, non-personal, to provide all plant, labor, transportation, materials, tools, equipment, appliances, and supervision necessary to renovate and enlarge a corrosion control facility by utilizing conventional design and construction methods at McEntire JNGB. The scope of this project will consist of a properly sited and configured Corrosion Control Facility supporting 24 PAA F-16 aircraft. It will include facility addition of like construction, all architecturally compatible with existing facility. It also includes reconfigured existing interior spaces, mechanical, electrical systems and modified latrines, replaced heating, ventilation and air conditioning (HVAC) systems, improved electrical distribution system, and replaced roof systems.
Update #2 ·
AMENDMENT 0001: Extend the bid due date from 30 May 2025 to 06 June 2025 at 2 PM EST.Services, non-personal, to provide all plant, labor, transportation, materials, tools, equipment, appliances, and supervision necessary to renovate and enlarge a corrosion control facility by utilizing conventional design and construction methods at McEntire JNGB. The scope of this project will consist of a properly sited and configured Corrosion Control Facility supporting 24 PAA F-16 aircraft. It will include facility addition of like construction, all architecturally compatible with existing facility. It also includes reconfigured existing interior spaces, mechanical, electrical systems and modified latrines, replaced heating, ventilation and air conditioning (HVAC) systems, improved electrical distribution system, and replaced roof systems.
Update #1 ·
Services, non-personal, to provide all plant, labor, transportation, materials, tools, equipment, appliances, and supervision necessary to renovate and enlarge a corrosion control facility by utilizing conventional design and construction methods at McEntire JNGB. The scope of this project will consist of a properly sited and configured Corrosion Control Facility supporting 24 PAA F-16 aircraft. It will include facility addition of like construction, all architecturally compatible with existing facility. It also includes reconfigured existing interior spaces, mechanical, electrical systems and modified latrines, replaced heating, ventilation and air conditioning (HVAC) systems, improved electrical distribution system, and replaced roof systems.
Attachments
| File | Type | Posted |
|---|---|---|
| Pre-Bid Conference Information.pptx | PPTX presentation | |
| Pre-Bid Conference Roster.pdf | ||
| W50S9525BA0010002 - Amendment 02 SF 30.pdf | ||
| Attachment 3 - Questions and Answers.pdf | ||
| Attachment 4 - Hazardous Material Survey - 2019.pdf | ||
| Attachment 5 - Form 3 Paint Booth BLDG 1046.pdf | ||
| W50S9525BA0010002 - Conformed through Amendment 02.pdf |
Notice history
| Notice | Type | Posted |
|---|---|---|
| ADAL Corrosion Control Facility | Award Notice | |
| ADAL Corrosion Control Facility | Solicitation | |
| PSTE 132004 ADAL Corrosion Control McEntire JNGB | Pre-Solicitation | |
| PSTE 132004 Corrosion Control McEntire JNGB | Pre-Solicitation |
On GovTribe
Work this opportunity on GovTribe
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity