About this opportunity
Pacific Air Forces' 735th Air Mobility Squadron is conducting market research to identify qualified contractors for HVAC work at Joint Base Pearl Harbor-Hickam, with responses due July 3, 2026; this is a sources-sought synopsis, not a solicitation, and no contract will be awarded from this announcement.
The work involves removal and replacement of twenty-six Variable Air Volume (VAV) controllers and twenty-six thermostats at Building 4069, with all labor, tools, equipment, and supervision provided by the contractor. Scope includes de-energizing and safely disconnecting existing broken components, installing new customer-provided Carrier components compatible with the building automation system, removing and replacing ceiling tiles, pulling new control wiring, restoring the work site, and properly disposing of all old components and debris. The contractor must coordinate with the government Contracting Officer's Representative throughout the project.
Place of performance is Building 4069, Moffett Street, Hickam Field, Joint Base Pearl Harbor-Hickam, Hawaii. Work is scheduled Monday through Friday, 0730–1630 hours, excluding federal holidays. Contractors must possess a current HVAC license; any electrical work requires a licensed electrician and compliance with Davis-Bacon wage determination HI20250001. Base access requires DBIDS passes and vehicle inspection at Kuntz Gate.
The procurement is set aside for Total Small Business. Performance objectives include no more than one customer complaint per removal and installation with 24-hour resolution, zero unresolved punch list items prior to final acceptance, and completion with zero complaints during installation and removal phases within 48-hour resolution timelines.
Notice text
This is a Sources Sought Synopsis, not a solicitation for proposals. No contract will be awarded from this announcement. The 735th Air Mobility Squadron (AMS) is seeking to identify qualified and experienced businesses capable of performing the work described herein. The purpose of this RFI is to conduct market research to determine the availability and adequacy of potential business sources prior to issuing a formal solicitation.
The Government is seeking information from businesses that can provide all labor, tools, equipment, and supervision necessary to remove and replace twenty-six (26) Variable Air Volume (VAV) controllers and twenty-six (26) associated thermostats at Building 4069, Joint Base Pearl Harbor-Hickam, HI.
Background & Scope of Work
As detailed in the Performance Work Statement (PWS), the project requires the removal of 26 broken VAV controllers and 26 thermostats and the installation of new, customer-provided Carrier components.
The scope includes, but is not limited to:
-
De-energizing, disconnecting, and safely removing all specified broken/obsolete components.
-
Installing 26 new VAV controllers and 26 new thermostats compatible with the existing building automation system.
-
Performing all ancillary tasks required for a complete installation, including removing/replacing ceiling tiles, pulling new control wiring, and restoring the work site to its original condition.
-
Properly removing and disposing of all old components and debris from the facility.
-
Coordinating all work with the government Contracting Officer's Representative (COR).
Required Contractor Qualifications & Certifications
The Government has a strong preference for contractors who can demonstrate the following qualifications to ensure system integrity, warranty protection, and adherence to federal law. Respondents should clearly state their ability to meet the following criteria:
-
Licensing: Possess a current HVAC contractor license. Any electrical work must be performed by a licensed electrician in accordance with the PWS.
-
EPA Certification: All technicians performing work must hold an EPA Section 608 Certification for proper refrigerant handling, as required by the Clean Air Act.
-
Manufacturer Authorization & Expertise (Highly Preferred): To protect the government's equipment warranty and ensure the highest quality of service, strong preference will be given to contractors who are Official Carrier Factory Authorized Dealers.
-
Technician Certification (Highly Preferred): In lieu of or in addition to factory authorization, contractors whose technicians hold North American Technician Excellence (NATE) certification are also preferred.
-
Use of Genuine Parts: The contractor will be required to use genuine, Original Equipment Manufacturer (OEM) parts for any components beyond the government-furnished controllers and thermostats to maintain system warranty.
Requested Information for Interested Parties
Interested parties are requested to submit a capabilities statement that addresses the following:
-
Company Information: Company name, address, point of contact, phone number, email address, CAGE code, and Unique Entity ID (UEI).
-
Business Size: Business size and status under NAICS code 238220 (e.g., Small Business, 8(a), HUBZone, Service-Disabled Veteran-Owned Small Business, etc.).
-
Statement of Capability: A brief narrative detailing your company's experience with similar HVAC control system replacement projects, particularly for Department of Defense or other federal agencies.
-
Qualifications and Certifications: Explicitly confirm your company’s ability to meet the mandatory and preferred qualifications listed in Section 2.0. Please state if you are a Carrier Factory Authorized Dealer and/or if your technicians hold NATE certifications.
This RFI is for market research and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled as such. The Government will not pay for any information or administrative costs incurred in response to this RFI.
Files
| File | Type | Posted |
|---|---|---|
| 735 AMS HVAC PWS.pdf |
Notice history
| Notice | Type | Posted |
|---|---|---|
| 735 AMS HVAC | Solicitation | |
| This notice | Pre-Solicitation |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| DCDO - HVAC Maintenance | Pacific Air Forces | No set-aside | |
| 648-22-104 Correct HVAC Deficiencies (P&V) | Veterans Integrated Service Network 20 | Service-Disabled Veteran-Owned Small Business | |
| Brand Name or Equal - WaterFurnace Model: UBH015R for B3631 & B3635 - Turnkey Replacement | Air Education and Training Command | No set-aside | |
| Combined Synopsis/Solicitation Notice: Maintenance of Commissary Refrigeration Systems and Repair of Refrigeration, Heating, Ventilation, and Air Conditioning Systems (HVAC) at Hario and Sasebo, Japan | ENDIST Japan | No set-aside | |
| Repair Mechanical Systems IDIQ (FY 27-32) | AFLCMC Wright Patterson AFB | No set-aside |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity