6525--radiology mammography tracking software sepg 499629 EER 270504 (VA-26-00027153)

Closed Solicitation Posted

Solicitation number
36C25926Q0349
Agency
Responses due
Set-aside
Total Small Business

Opportunity facts

NAICS code
513210 Software Publishers
Place of performance
Department of Veteran Affairs, Visn 19 Oklahoma City Vamc Oklahoma City OK 73014

Notice details come from SAM.gov. Updated .

About this opportunity

The Department of Veterans Affairs, Veterans Health Administration, Veterans Integrated Service Network 19 is soliciting mammography tracking software to replace the existing Magview Luminary One system at the Oklahoma City VA Medical Center. The solution must include a minimum of three concurrent user licenses along with implementation, planning, configuration, and on-site support services, followed by four option years of annual support and maintenance. Key functional requirements include patient management with comprehensive medical history tracking, exam tracking with BI-RADS categories, automated reminder systems, MQSA and ACR compliance with audit-ready reporting, integration with VISTA RIS, AGFA PACS, CPRS EHR, and Powerscribe systems, role-based access control with HIPAA compliance, and analytics dashboards with Tyrer-Cuzick Score risk assessment functionality. The contract will be awarded based on technical capability to meet Government requirements and price, with the Government reserving the right to select offerings exceeding minimum requirements. The original response deadline of March 30, 2026, at 4:00 PM Mountain Time has been extended to April 3, 2026, at 11:00 AM Mountain Time, with no further questions accepted beyond the deadline of March 26, 2026.

This is a 100% small business set-aside (NAICS code 513210, size standard $47.0 million) with firm-fixed pricing under solicitation number 36C25926Q0349. The incumbent system, Magview Luminary One, will be replaced with legacy data migration required from both Magview Luminary One and CPRS systems. The Government expects to handle approximately 1,305 in-house mammography exams annually, along with 339 diagnostic exams, 262 ultrasounds, 32 MRI scans, and 11 biopsies, with a target go-live date of May 1st. The vendor must be the Original Equipment Manufacturer or an authorized dealer/distributor with OEM warranty maintained throughout the contract term, and support must be provided for GE Pristina mammography equipment. Performance will take place at the Oklahoma City VA Medical Center in Calumet, Oklahoma 73014, with delivery F.O.B. Destination to the Ernest Childers VA Outpatient Clinic in Tulsa, Oklahoma, and quotes must be submitted via email to Christopher.delauro@va.gov with a maximum file size of 4MB.

Notice text

2 versions

Update #2 · Latest ·

This RFQ is hereby extended until 4/3 at 11:00am Mountain Time

The purpose of this amendment is to provide answers to questions as listed below.

No more questions will be accepted.

What is the preferred deployment timeline and target go-live date? Â

 May 1st

What is the approximate annual mammography exam/imaging volume (diagnostic and screening exams combined Mammography, Ultrasound, MRI, Biopsy, etc.)?Â

During FY 25

Mammo in house 1,305

Diagnostic 339

Ultrasound 262

MRI 32

Biopsy 11

Is there an existing mammography tracking system or other source system currently in use that will be replaced upon award?Â

Magview Luminary One

Is any legacy data migration required? If so, what data sources, approximate record counts, and data elements are expected to be migrated?Â

Â

Yes from magview luminary One and CPRS

Does the government have a VA-managed private cloud environment for deploying elements of the proposed solution?Â

Yes. We have a cloud environment

Will PHI be required to stay on-prem, or is a cloud solution acceptable?

Probably ok on cloud

What are the current mammography unit(s) (manufacturers and models)?Â

GE Pristina

The RFP specifies recording patient risk factors (e.g., family history, genetic predisposition). Is risk assessment functionality sought as part of the solution?Â

Â

We use Tyrer-Cuzick Score, this functionality Must be part of the solution

Is there an existing mammography reporting system that the proposed solution is expected to integrate with, or is mammography reporting functionality required to be included as part of the solution?Â

Yes Magview Luminary One

Can you get me an estimate of the following: Total annual study volume for the facility (this includes all exams, not just Mammography). And the total annual mammography exams for the facility.Â

FY25

Mammo 2905

CT 15920

Xray 39183

MRI 7340

Nuke 6137

Ultrasound 6844

Is Vista-certified acceptance included in this project? As i understand it only, the South Korean owned MRS/Volpara/Lunit is vista certified in Breast Imaging.Â

This software will need to integrate with VISTA but uncertain about certification requirement

How many imaging locations are included in this RFQ?

Just 1 Ernest Childers

Do you perform any genetic testing?

Yes but not a necessary part of this requirement

Do you perform bone density scans?

Yes -but not a necessary part of this requirement

Would you like electronic forms included to help gather clinical history prior to an exam?

An electronic template is needed, but we will be gathering clinical history from printed paper forms and entering manually

Which RIS or EHR system will need to be interfaced with?

CPRS, AGFA EI, VISTA

Will the interface be required with both the RIS and EHR, or is there one system that serves as the source of truth?

RIS and EHR

Please confirm that radiology reporting does not need to be included in the platform, and that this requirement is for tracking only, with radiologists reading/reporting in a separate system

Radiologist does not use this

Powerscribe needs to be connected intergrated

Pacs=AGFA EI does need access

Here is an outline of the workflow: Veteran uses VISTA when checking in, Vista interfaces with Tracker system and PACS to connect images, information is read by radiologist using PACS via Powerscribe, which then triggers reports to doctors and other medical staff.

Page 7, section J, part II - (II) - Completion of Attachment - VAAR Clause 852.219-78 VA Notice of Limitations on Subcontracting-Certificate of Compliance for Supplies and Products (DEVIATION) ; - It is asking us to complete the attachment VAAR Claus 852.219.78

THIS CLAUSE IS NOT APPLICABLE TO THIS SOLICITATION (852.219-78)

Update #1 ·

Mammogram Tracking Software.

Files

File Type Posted
36C25926Q0349 0001.docx DOCX document
36C25926Q0349.docx DOCX document

Similar open opportunities

Opportunity Agency Set-aside Responses due
6525--SEP 2026 Equipment Only Consolidation NAICS 334517 National Acquisition Center No set-aside
DA10--RFI VHA Radiology and Cardiology Enterprise Imaging NAICS 541511 VA Technology Acquisition Center No set-aside
J065--Fort Harrison GE Precision Radiology Preventive Maintenance NAICS 811210 Veterans Integrated Service Network 19 No set-aside
3D Image Reconstruction and Case Planning Services Gainesville, Florida 32610, United States · NAICS 621512 Veterans Integrated Service Network 8 Total Small Business
H265--diagnostic imaging equipment testing Florida 32608, United States · NAICS 621512 Veterans Integrated Service Network 8 Service-Disabled Veteran-Owned Small Business