6525--CTX MRI Compatible Projector System

Closed Pre-Solicitation Posted

Solicitation number
36C25726Q0685
Agency
Veterans Integrated Service Network 17 Veterans Health Administration, Department of Veterans Affairs
Responses due
Set-aside
No set-aside

Opportunity facts

NAICS code
339112 Surgical and Medical Instrument Manufacturing
PSC
6525 Imaging Equipment And Supplies: Medical, Dental, Veterinary
Points of contact

Notice details come from SAM.gov. Updated .

About this opportunity

The Department of Veterans Affairs Veterans Integrated Service Network 17 is preparing to procure an MRI-compatible projector system, with responses due by June 29, 2026. The VISN 17 Center of Excellence in Waco, Texas requires the Hyperion 2 projection system from Psychology Software Tools (PST) specifically, designed to display visual stimuli in an MRI environment.

The procurement includes three components: the Hyperion 2-120 MRI Digital Projection System (PST-101891), a high-resolution 1920x1080 DLP projector with automatic frame synchronization at 60Hz or 120Hz, RF-filtered enclosure, and temperature-controlled fan operation; the Hyperion Short-Throw Lens (PST-101322R); and the MRI-Compatible Pedestal Projector Stand with locking caster wheels (PST-102627). All items must be constructed from non-magnetic materials and shielded against radio-frequency pulses. The vendor must also provide training for technicians and designated personnel.

Place of performance is the VISN 17 Center of Excellence at 4800 Memorial Drive, Building 93, MRI W93, Waco, Texas 76711, with contracting oversight by the Network Contracting Office 17 in San Antonio, Texas. No set-aside applies. NAICS code is 339112 (Surgical and Medical Instrument Manufacturing); PSC is 6525.

Responses should be submitted to Contract Specialist Rafael Rodriguez (Rafael.Rodriguez2@va.gov) and Contracting Officer Francisco Mendoza (Francisco.Mendoza2@va.gov), with solicitation number 36C25726Q0685 in the subject line. Respondents must provide business registration data, SAM UID and status, business size and type classifications, applicable GSA or VA FSS contract numbers, and place of manufacturing. This notice is issued for informational and planning purposes only and does not constitute a binding solicitation.

Notice text

Page 4 of 4

Page 1 of

Page 1 of

This market research notice is being conducted by Network Contracting Office (NCO) 17- VA South Texas (VASTHCS) facilities.

The VISN 17 Center of Excellence, located at 4800 Memorial Drive, Building 93, MRI W93, Waco, TX 76711 has requested an MRI Compatible Projector. Vendor will provide a system that meets the outlined specifications below. Additionally, vendor will provide training for Techs and other designated personnel.

The center requires the Hyperion 2 projection system from Psychology Software Tools (PST) specifically. It is designed to display visual stimuli in an MRI environment. Magnetic Resonance Imaging (MRI) utilizes powerful magnetic fields, which can be dangerous to people and machinery if the equipment is not properly engineered and tested. The projector s electrical components and stands must be built from non-magnetic materials and must work with a system of mirrors to allow the participant to view visual displays while in the middle of the MR machine. As you can imagine this is problematic for computerized machinery, particularly since all components and cables must also be shielded by radio-frequency pulses sent out by the MR machine. Due to these difficulties and strict safety guidelines, few companies produce MRI compatible visual display systems.

All items listed below are required to complete our Projector system needs:

Stock Number

Item Description

OrderQuantity

PST-101891

Hyperion 2-120 MRI Digital Projection System

1

PST-101322R

Hyperion Short-Throw Lens

1

PST-102627

MRI-Compatible Pedestal Projector Stand

1

Part number descriptions:

PST-101891:

Hyperion 2-120 MRI Digital Projection System: Hyperion 2-120 - High resolution (1920x1080) DLP Projector with automatic frame synchronization at 60Hz or 120Hz, RF filtered enclosure, temperature-controlled fan operation with thermal cut-out sensor ensures adequate cooling. Includes a Remote Control, 30 Meter Fiber Cable, and Control Room Console with LCD touchscreen display.

PST-101322R:

Hyperion Short-Throw Lens: Short-throw lens for use with Hyperion 2-120 MRI Digital Projection System.

PST-102627:

MRI-Compatible Pedestal Projector Stand: Hyperion 2-120 MRI-Compatible Projector Pedestal Stand with locking caster wheels.

Additional Information:

Our MRI lab is already fitted with an aging Hyperion 1 system, that is uniquely compatible with a number of different (non-projector) machines and software. This includes optimized integration with other PST products such as MR-safe button-response boxes and E-Prime stimulus presentation software (e.g., used to display images or administer experimental tasks), which records timing information with millisecond accuracy and shares this with other concurrently recording machines (i.e., MRI-pulses, eye-tracker, central and peripheral nervous systems). Unlike most other stimuli presentation software, the software is explicitly compatible with our other systems (Brain Vision for brain and body system measurements, and Eyelink used for tracking eye movements as a participant views visual displays) and the computer code required to facilitate communication between these systems is readily available. These systems must properly cooperate.

Timing is of the utmost importance for our research and PST equipment has software designed for speedy transmission. Additionally, the monetary cost of replacing all the existing projector equipment and cables (e.g., specialized fiber optic cables) would be high as would be the man-hours required to install and adapt a different system into our existing framework.

Responses shall include:

Business Name

Business Address

Point of Contact

Name

Phone Number

E-mail Address

SAM UID Number

Currently registered in SAM (Yes or No). If Yes, provide expiration date.

NAICS code

Business Size: Small or Large

Type of Business: Service-Disabled Veteran Owned (SDVOSB), Veteran Owned (VOSB), 8(a), HUBZone, Woman-Owned (WOSB), etc.

GSA or VA FSS Contract Number, if applicable

Place of Manufacturing

All businesses eligible to provide these supplies are encouraged to reply as this information may be used to determine potential set-asides for the above-noted requirement.

Send responses to both the Contract Specialist.

Contract Specialist: Mr. Rafael Rodriguez at Rafael.Rodriguez2@va.gov

Contracting Officer: Mr. Francisco Mendoza at Francisco.Mendoza@va.gov

Responses in the email subject line shall state: 36C25726Q0685, Sources Sought Notice

Responses due date: 06/29/2026- 11:00 AM CT

DISCLAIMER: This notice is issued solely for informational and planning purposes and does not constitute a solicitation. Responses to this notice are not offers and cannot be accepted by the Department of Veterans Affairs to form a binding contract. Respondents are solely responsible for all expenses associated with responding to this notice.