36C25726Q0685.docx

DOCX document 22 KB Posted

Attached to
6525--CTX MRI Compatible Projector System Federal contract opportunity
Solicitation number
36C25726Q0685
Issued by
Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 17

About this file

This is a Sources Sought Notice issued by the Department of Veterans Affairs Network Contracting Office (NCO) 17 – VA South Texas Health Care System (VASTHCS) for an MRI Compatible Projector System. The VISN 17 Center of Excellence in Waco, Texas is seeking to procure a complete Hyperion 2 projection system from Psychology Software Tools (PST), specifically designed for displaying visual stimuli in an MRI environment. The required components include: the Hyperion 2-120 MRI Digital Projection System (PST-101891), a high-resolution 1920x1080 DLP projector with automatic frame synchronization at 60Hz or 120Hz, RF filtered enclosure, and temperature-controlled fan operation; the Hyperion Short-Throw Lens (PST-101322R); and the MRI-Compatible Pedestal Projector Stand with locking caster wheels (PST-102627). All components must be constructed from non-magnetic materials and shielded against radio-frequency pulses. The vendor must also provide training for technicians and designated personnel.

Responses are due by June 29, 2026, at 11:00 AM Central Time and should be submitted to Contract Specialist Rafael Rodriguez at Rafael.Rodriguez2@va.gov and Contracting Officer Francisco Mendoza at Francisco.Mendoza2@va.gov, with the solicitation number 36C25726Q0685 in the subject line. Respondents must provide business name, address, point of contact information, SAM UID number and registration status, NAICS code (339112), business size classification, business type designation (SDVOSB, VOSB, 8(a), HUBZone, WOSB, etc.), applicable GSA or VA FSS contract numbers, and place of manufacturing. The contracting office is located in San Antonio, Texas (ZIP 78240). This notice is issued for informational and planning purposes only and does not constitute a binding solicitation; responses are not offers and respondents bear all associated costs.

View the file

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SUBJECT*

CTX MRI Compatible Projector System

GENERAL INFORMATION

CONTRACTING OFFICE’S ZIP CODE*
78240
SOLICITATION NUMBER*
36C25726Q0685
RESPONSE DATE/TIME/ZONE
06-29-2026 11:00AM CENTRAL TIME, CHICAGO, USA
ARCHIVE
45 DAYS AFTER THE RESPONSE DATE
RECOVERY ACT FUNDS
N

SET-ASIDE

PRODUCT SERVICE CODE*
6525
NAICS CODE*
339112

CONTRACTING OFFICE ADDRESS

Network Contracting Office 17 5441 Babcock Road Ste. 302

San Antonio TX 78240

POINT OF CONTACT*

Contracting Officer Rafael Rodriguez Rafael.Rodriguez2@va.gov

PLACE OF PERFORMANCE

ADDRESS

POSTAL CODE

COUNTRY

ADDITIONAL INFORMATION

AGENCY’S URL

URL DESCRIPTION

AGENCY CONTACT’S EMAIL ADDRESS
Rafael.Rodriguez2@va.gov

EMAIL DESCRIPTION

Sources Sought Notice Sources Sought Notice

DESCRIPTION

*= Required Field
Sources Sought Notice

Sources Sought Notice

This market research notice is being conducted by Network Contracting Office (NCO) 17- VA South Texas (VASTHCS) facilities.

The VISN 17 Center of Excellence, located at 4800 Memorial Drive, Building 93, MRI W93, Waco, TX 76711 has requested an MRI Compatible Projector. Vendor will provide a system that meets the outlined specifications below. Additionally, vendor will provide training for Techs and other designated personnel.

The center requires the Hyperion 2 projection system from Psychology Software Tools (PST) specifically. It is designed to display visual stimuli in an MRI environment. Magnetic Resonance Imaging (MRI) utilizes powerful magnetic fields, which can be dangerous to people and machinery if the equipment is not properly engineered and tested. The projector’s electrical components and stands must be built from non-magnetic materials and must work with a system of mirrors to allow the participant to view visual displays while in the middle of the MR machine. As you can imagine this is problematic for computerized machinery, particularly since all components and cables must also be shielded by radio-frequency pulses sent out by the MR machine. Due to these difficulties and strict safety guidelines, few companies produce MRI compatible visual display systems.

All items listed below are required to complete our Projector system needs:

Stock Number
Item Description
OrderQuantity
PST-101891
Hyperion 2-120 MRI Digital Projection System
1
PST-101322R
Hyperion Short-Throw Lens
1
PST-102627
MRI-Compatible Pedestal Projector Stand
1

Part number descriptions:

· PST-101891:

· Hyperion 2-120 MRI Digital Projection System: Hyperion 2-120 - High resolution (1920x1080) DLP Projector with automatic frame synchronization at 60Hz or 120Hz, RF filtered enclosure, temperature-controlled fan operation with thermal cut-out sensor ensures adequate cooling. Includes a Remote Control, 30 Meter Fiber Cable, and Control Room Console with LCD touchscreen display.

· PST-101322R:

· Hyperion Short-Throw Lens: Short-throw lens for use with Hyperion 2-120 MRI Digital Projection System.

· PST-102627:

· MRI-Compatible Pedestal Projector Stand: Hyperion 2-120 MRI-Compatible Projector Pedestal Stand with locking caster wheels.

Additional Information:

Our MRI lab is already fitted with an aging Hyperion 1 system, that is uniquely compatible with a number of different (non-projector) machines and software. This includes optimized integration with other PST products such as MR-safe button-response boxes and E-Prime stimulus presentation software (e.g., used to display images or administer experimental tasks), which records timing information with millisecond accuracy and shares this with other concurrently recording machines (i.e., MRI-pulses, eye-tracker, central and peripheral nervous systems). Unlike most other stimuli presentation software, the software is explicitly compatible with our other systems (Brain Vision for brain and body system measurements, and Eyelink used for tracking eye movements as a participant views visual displays) and the computer code required to facilitate communication between these systems is readily available. These systems must properly cooperate.

Timing is of the utmost importance for our research and PST equipment has software designed for speedy transmission. Additionally, the monetary cost of replacing all the existing projector equipment and cables (e.g., specialized fiber optic cables) would be high as would be the man-hours required to install and adapt a different system into our existing framework.

1. Responses shall include:

1. Business Name

1. Business Address

1. Point of Contact

2. Name

2. Phone Number

2. E-mail Address

1. SAM UID Number

1. Currently registered in SAM (Yes or No). If Yes, provide expiration date.

1. NAICS code

1. Business Size: Small or Large

1. Type of Business: Service-Disabled Veteran Owned (SDVOSB), Veteran Owned (VOSB), 8(a), HUBZone, Woman-Owned (WOSB), etc.

1. GSA or VA FSS Contract Number, if applicable

1. Place of Manufacturing

All businesses eligible to provide these supplies are encouraged to reply as this information may be used to determine potential set-asides for the above-noted requirement.

1. Send responses to both the Contract Specialist.

Contract Specialist: Mr. Rafael Rodriguez at Rafael.Rodriguez2@va.gov

Contracting Officer: Mr. Francisco Mendoza at Francisco.Mendoza@va.gov

Responses in the email subject line shall state: 36C25726Q0685, Sources Sought Notice Responses due date: 06/29/2026- 11:00 AM CT DISCLAIMER: This notice is issued solely for informational and planning purposes and does not constitute a solicitation. Responses to this notice are not offers and cannot be accepted by the Department of Veterans Affairs to form a binding contract. Respondents are solely responsible for all expenses associated with responding to this notice.

Page 1 of Page 1 of Page 1 of

File details come from the government source that posted it. Updated .