618-26-702 EHRM Install DDPO 2
Closed Solicitation Posted
Not the latest version. See the latest solicitation from .
- Solicitation number
- 36C26326B0030
- Agency
-
Veterans Integrated Service Network 23
Veterans Health Administration, Department of Veterans Affairs
- Responses due
- Set-aside
- Service-Disabled Veteran-Owned Small Business
Opportunity facts
- NAICS code
- 238210 Electrical Contractors and Other Wiring Installation Contractors
- Place of performance
- Minneapolis, Minnesota 55417, United States
Notice details come from SAM.gov. Updated .
About this opportunity
The Department of Veterans Affairs Veterans Integrated Service Network 23 seeks construction services for Electronic Health Records Modernization (EHRM) Data Drops and Power Outlets installation at the Minneapolis VA Medical Center, with sealed bids due June 9, 2026 at 10:00 AM CDT. The procurement is set aside exclusively for Service-Disabled Veteran-Owned Small Businesses (SDVOSB), with competition restricted to firms verified in the VetCert database.
Place of performance is Minneapolis, Minnesota (One Veterans Drive, Minneapolis, MN 55417-2309). The scope includes installation of 29 CAT 6A cable drops from new Telecommunication Rooms to identified locations (cable pulls not exceeding 300 feet), 50 duplex 120-volt emergency power outlets (installations not exceeding 250 feet), mounting of Over-Current Elements, tracking boards, wall mounts, wall demolition, repair, and finishing. All data cabling must be Category 6A with power and transmission cables installed in separate raceways per manufacturer specifications. The contractor must conduct pre-construction risk assessments and Infection Control Risk Assessments (ICRA) per VA Standard Environment of Care Standard EC 02 06 05, comply with NFPA 70 (NEC), OSHA, and TIA standards, and maintain 24/7 facility operations during construction. Work must begin within 10 days of Notice to Proceed and complete within 95 calendar days, with a mandatory site visit on May 20, 2026 at 10:00 AM PST.
The estimated construction cost range is $250,000 to $500,000. NAICS code is 238210 (Electrical Contractors). A bid guarantee of not less than 20 percent of the bid price is required; performance and payment bonds at 100 percent of the awarded contract amount must be submitted within ten calendar days of award. Funds are contingent upon availability, anticipated by September 30, 2026 for FY26 or November 30, 2026 for FY27. For SDVOSB contracts, subcontracting limitations are 85 percent for general construction contracts (prime may pay up to 85 percent to non-certified SDVOSB/VOSB firms). Prevailing wage rates per Hennepin County, Minnesota wage determination apply, ranging from $22.50 to $62.52 per hour depending on labor classification.
Notice text
The intent of this project is to provide construction services for a Department of Veteran Affairs Electronic Health Records Modernization (EHRM) project initiative and a 2026 Current State Review (CSR) at the Minneapolis VA Medical Center, One Veterans Drive, Minneapolis, MN 55417-2309. The initiative is an implementation and the deployment of new Electronic Health Record (EHR) system across federal entities and install additional Data Drop and Power Outlets (DDPO’s) as identified during the CSR assessment.
- The construction contractor shall supply all equipment, labor, materials, and supervision to complete project upgrades which includes the installation of Data Drops and Power Outlets, mounting of Over-Current Elements (OCE’s), Tracking Boards and Wall mounts.
- Conduct and incorporate pre-construction risk assessments (PCRA) and Infection Control Risk Assessments (ICRA) for air quality, infection control, noise, vibration, or any other hazards applicable to their work per Veterans Affairs (VA) Standard Environment of Care Standard (EC) 02 06 05. See ICRA Matrix of Precautions for Construction and Renovation. See Attachment 3 ICRA Assessments, Level 2 through 4 (three [3] total).
- Power and transmission cable pulls will be installed in separate raceways/conduits/ and or separated, per manufacturer performance data information.
- All data cabling to be Category CAT 6A.
- Install quantity (QTY) (29) CAT 6A cable drops from new Telecommunication Rooms (TRs) to identified locations. See Building Plan Views for 618-26-702 for room and wall locations of installs.
- Telecommunication Cable pulls/drops not to exceed 300 feet for estimating purposes.
- QTY (1) cable drop location will require QTY (29) CAT 6A cables to be pulled.
- The QTY (29) cable drops installed within wall space to be protected in conduit requiring demolition of a wall section, repair and paint finishing.
- Furnish and install wall boxes and cover plates as needed for network connections or power installations.
- Follow current telecommunication or efficient routing paths above or below ceiling from Telecommunications Room (TR) patch panels to wall room outlets. All cables shall be in continuous lengths for origin to destination and secured to cable support structures per National Electric Code (NEC) requirements. (Any and all Cable splices will have to be approved by the COR)
- All new CAT 6A cable installations shall be tested and certified. Certification reports shall be submitted to the COR Bi-Weekly.
- All new cable pulls to be terminated at both ends. Termination locations in TR closets will be identified by site Subject Matter Experts (SME’s)
- Contractor to follow current VA Standards for cable, patch panel, and outlet labeling. All labels to be machine generated (not hand-written) using labeling software or machine.
- Install QTY (50) duplex 120 Volts Alternating Current (VAC) emergency power sourced outlets.
- Contractor to consider emergency power installations not to exceed 250 feet.
-
- Contractor to conduct a load test in the nearest junction box to verify the suitability for both new and existing outlets.
- The combined loads in a circuit shall not exceed 80% of the circuit’s total load capacity.
- If extending from an existing junction box to surface mounted raceway, flexible conduit may be used if it does not exceed 6 feet in length.
-
- Analog Phone List. Contractor to complete all work in accordance with:
- VA standards and Construction Specifications.
- NEC Standards
- Office of Electronic Health Record Modernization (OEHRM) Site Infrastructure, and End user Device (EUD) requirements (Latest Revision)
- Office of Information Technology (OIT) Design Guide, and design templates
- Infrastructure Standard for Telecommunication Spaces (ISTS) (Latest Version).
- Replace any damaged ceiling tiles due to the course of work.
- Touchup/repair/paint and damaged walls or ceilings due to new installation of wire and cable, conduit installations,etc. This project shall be completed within Ninety-Five (95) calendar days once NTP is issued.
Files
Notice history
| Notice | Type | Posted |
|---|---|---|
| 618-26-702 EHRM Install DDPO 2 | Solicitation | |
| 618-26-702 EHRM Install DDPO 2 | Solicitation | |
| 618-26-702 EHRM Install DDPO 2 | Solicitation | |
| 618-26-702 EHRM Install DDPO 2 | Solicitation | |
| 618-26-702 EHRM Install DDPO 2 | Solicitation | |
| This notice | Solicitation | |
| 618-26-702 EHRM Install DDPO 2 | Pre-Solicitation |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| 542-22-700 | EHRM Construct Infrastructure Upgrade | Coatesville, PA | | VA Technology Acquisition Center | Service-Disabled Veteran-Owned Small Business | |
| Y1DA--VISN 2 EHRM Industry Day | VA Technology Acquisition Center | No set-aside | |
| Y1DZ--Brooklyn Upgrade Life Safety/Critical Branch Electrical Distribution Construction | VA Technology Acquisition Center | Total Small Business | |
| PN: 438-21-403, Renovate First Floor Kitchen (SF) | Veterans Integrated Service Network 23 | Service-Disabled Veteran-Owned Small Business | |
| Reverse Osmosis System Modifications | Veterans Integrated Service Network 23 | No set-aside |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity