5650--American Lake B81 Lab Roof
Closed Pre-Solicitation Posted
Not the latest version. See the latest pre-solicitation from .
- Solicitation number
- 36C26026Q0790
- Agency
-
Veterans Integrated Service Network 20
Veterans Health Administration, Department of Veterans Affairs
- Responses due
- Set-aside
- No set-aside
Opportunity facts
- NAICS code
- 238160 Roofing Contractors
- PSC
- 5650 Roofing And Siding Materials
- Place of performance
- Puget Sound HCS American Lake Vamc Joint Base Lewis-McChord WA 98493
- Points of contact
Notice details come from SAM.gov. Updated .
About this opportunity
The Department of Veterans Affairs, Network Contracting Office 20, is conducting a sources sought notice to identify viable contractors for TPO roofing system replacement at VA Puget Sound – American Lake Campus in Tacoma, Washington, with responses due by 10:00 AM PDT on July 10, 2026. This is a pre-solicitation notice only; the VA is not currently soliciting pricing or offers.
Work is performed at Building 81, 9600 Veterans Drive SW, Tacoma, Washington 98493. The contractor must furnish all labor, materials, equipment, and supervision to replace an existing failing torch-down roof above laboratory storage rooms with a complete TPO roofing system, including membranes, underlayment, insulation, flashing, sealants, and finish materials, in accordance with manufacturer specifications and industry standards. Seven air conditioning units cooling the laboratory below must remain functional nearly year-round; AC downtime is limited to a single weekend to minimize disruption to laboratory operations.
Period of performance is approximately 120 calendar days after receipt of notice to proceed. The estimated project value ranges between $5 million and $10 million. Contractor escort by Facilities Management Service staff is required during work. Acceptance criteria include successful water leak testing at seams and penetrations, aesthetic matching of flashings to original specifications, and full AC unit operability verified by facility maintenance personnel.
Interested parties must submit responses not exceeding five pages, including contact information, business size classification, capabilities statement with bonding information, total project time estimate, and past performance on three similar contracts completed within the past five years. Submit to Contracting Officer Ty Draszt at Ty.Draszt@va.gov. NAICS Code 238160 (Roofing Contractors); small business size standard is $19 million.
Notice text
Sources Sought American Lake B81 Lab Roof
THIS IS A SOURCES SOUGHT NOTICE ONLY.
THIS IS NOT A REQUEST FOR PROPOSAL OR QUOTE; THE VA IS NOT SEEKING PRICING OR OFFERS.
The Department of Veterans Affairs, NCO 20, in support of VA Puget Sound - American Lake Campus, Tacoma, WA is currently requesting information to determine the existence of viable sources capable of providing construction services.
Period of Performance:
The intended contract period of performance is approximately 120 calendar days after receipt of notice to proceed.
Description of Services:
The Contractor shall furnish all labor, materials, equipment, and supervision necessary to provide and install a complete TPO roofing system. The roofing system shall be a fully integrated, weather resistant assembly that includes all required roofing membranes, underlayment, insulation, flashing, sealants, and finish roofing materials. The system shall be installed in accordance with applicable manufacturer specifications, industry standards, and governing codes. When completed, the roofing system shall provide continuous, complete, and effective protection of the enclosed space below from all external environmental elements, including precipitation, wind, temperature intrusion, and moisture. The air conditioning down-time shall be limited to a weekend to have negligible effect on laboratory operations.
The small flat roof above the laboratory storage rooms in Building 81 has experienced persistent leaks for several years. Although multiple repairs have been attempted, including large applications of tar, the roof continues to fail. The existing torch down roof will be replaced with a TPO roofing system to provide a long term solution. The area includes seven AC units that cool the laboratory below and must remain functional nearly year round.
NAICS Code:
238160 Roofing Contractors
Small business size standard: $19 Million
The Government is not soliciting offers at this time, and it will be the Contracting Officer who will determine which suggested changes are accepted. This is a sources sought notice to gain knowledge of potential qualified sources. A solicitation is not currently available.
Responses:
Responses to this request will be considered for the purpose of determining how the requirements will be stated and how the procurement will be conducted. This announcement is not to be construed as a commitment by the Government, implied or otherwise, to issue a solicitation or to award a contract. No reimbursement will be made for any costs associated with providing information in response to this synopsis or any follow-up information requests.
If you are interested and can provide the required services, please complete the questionnaire below and email your response to Ty.Draszt@va.gov. no later than 1000 AM PDT, July 10, 2026. Include any comments or questions you may have. Also provide your capability statements within your response.
A SOURCES SOUGHT QUESTIONNAIRE is below. Responses to the Questionnaire are encouraged from all interested parties. You are advised that providing responses to the questions will not automatically include you in the acquisition process for this solicitation. Please provide any additional feedback in your response that you feel is relevant.
Responses are requested with the following information and shall not exceed a total of 5 (five) pages.
Email subject line needs to contain the sources sought number 36C26026Q0790
Please provide the following information:
Contact information: Name, address, SAM.gov UEI number, and points of contact with telephone numbers and e-mail addresses.
Business Size/Classification (based on NAICS 238160):
Is your firm eligible for participation in one of the following small business programs? If so, please indicate the program.
[ ] yes [ ] no Small Business (SB)
[ ] yes [ ] no HUBZone
[ ] yes [ ] no Small Business 8(a)
[ ] yes [ ] no Small Disadvantaged Business (SDB)
[ ] yes [ ] no Women-Owned (WO) Small Business
[ ] yes [ ] no Service-Disabled Veteran Owned Small Business (SDVOSB)
[ ] yes [ ] no Veteran Owned Small Business (VOSB)
[ ] yes [ ] no Other (please specify)
Capabilities Statement: Description of capabilities to perform construction services as described above and project experience demonstrating relevant experience similar to those described. Include bonding capability information that is consistent with estimated magnitude between $5,000,000 and $10,000,000.
Govt. does not have a waiver to Buy American.
SDVOSB or VOSB businesses please include statement on maintaining compliance with VAAR 852.219-75 VA Notice of Limitations on Subcontracting Certificate of Compliance for Services and Construction, 852.219-76 VA Notice of Limitations on Subcontracting Certificate of Compliance for Supplies and Products.
All other socio-economic businesses please include statement on maintaining compliance with FAR 52.219-14 Limitations on Subcontracting.
Time: Based on the information provided, please estimate the total project time in days.
Past Performance/experience: Provide information on contracts of similar scopes of work or construction contracts, briefly describe no more than three (3) contracts (or specific task orders) completed within the past five years of the issue date of this Sources Sought notice. The past performance information should include:
Project Title/Contract Number
Location: City, State
General description of the construction to demonstrate relevance to the proposed project
Offerors role
Dollar value of contract
Name of the company, agency, or government entity for which the work was performed
What types of information is required to submit accurate offers?
If submitting past performance/experience on a project in the role of a subcontractor, include the Prime Contractor s name and a quantifiable amount (percentage) of the project your company contributed to the overall scope of work.
Note: Do not include Proprietary, classified, confidential, or sensitive information in responses.
NO RESPONSES WILL BE ACCEPTED BY FAX.
Responses will not be returned. Telephonic responses will not be honored. Please respond by email only. Send responses to the Contracting Officer Ty Draszt via email at Ty.Draszt@va.gov.
Files
| File | Type | Posted |
|---|---|---|
| Draft SOW - 20260605 - American Lake B81 Lab Roof.docx | DOCX document | |
| 36C26026Q0790.docx | DOCX document |
Notice history
| Notice | Type | Posted |
|---|---|---|
| 5650--American Lake B81 Lab Roof | Pre-Solicitation | |
| This notice | Pre-Solicitation |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| Z2DA--657-27-103JB, FCA Replace Building 51 Roof, JB | Veterans Integrated Service Network 15 | Service-Disabled Veteran-Owned Small Business | |
| Z1DA-- 460-26-004 | Wilmington VAMC Roof Replacement | NCO 4 Construction East (VA-26-00029152) | Veterans Integrated Service Network 4 | Service-Disabled Veteran-Owned Small Business | |
| Z1DZ--Project No. 640A0-27-104, Replace Roof at Building 347 - Menlo Park | Veterans Integrated Service Network 21 | Service-Disabled Veteran-Owned Small Business | |
| C1DA--AE Replace Roofing 539-25-101 | Veterans Integrated Service Network 10 | Service-Disabled Veteran-Owned Small Business | |
| C1AZ--657A4-26-125 Conduct Roof Deck Assessment Building 8 ME FY27 NRM | Veterans Integrated Service Network 15 | Service-Disabled Veteran-Owned Small Business |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity