23rd STS IDS Installation
Closed Solicitation Posted
- Solicitation number
- FA441725Q0100
- Agency
-
Air Force Special Operations Command
Air Force, Department of Defense
- Responses due
- Set-aside
- Total Small Business
Opportunity facts
- NAICS code
- 561621 Security Systems Services (except Locksmiths)
- Place of performance
- Hurlburt Field, Florida 32544, United States
Notice details come from SAM.gov. Updated .
About this opportunity
The Department of the Air Force Special Operations Command is soliciting proposals for the installation of a Vindicator Intrusion Detection System (IDS) for the 23rd Special Tactics Squadron at Hurlburt Field, Florida. The project requires installation of comprehensive security components including 360-degree motion sensors, balance magnetic switches, tamper switches, compatible keypads, and a Honeywell graphical keypad across five specific rooms (1238, 2024, 2014, 2031, 2027) in Building #91650, with all equipment required to be Windows 10 compatible. Contractors must have Honeywell Vindicator certification and employ U.S. citizens who have undergone trustworthiness determinations for the installation and testing work. The evaluation will utilize a best-value trade-off approach based on price, technical acceptability, and past performance, with technical and past performance factors weighted more heavily than price. The solicitation has undergone multiple amendments, with the most recent removing access control system requirements and clarifying equipment specifications. Proposals are due September 19, 2025, at 2:00 PM CDT, with a site visit scheduled for August 22, 2025, at 10:00 AM CDT.
This procurement is set aside for small businesses under NAICS code 561621 (Security Systems Services) with a size standard of $25 million. The contractor must demonstrate past performance through two recent and relevant electronic security system projects within the past six years, showing capabilities in engineering development, design, procurement, configuration, integration, or installation. The work includes a comprehensive three-phase testing process consisting of contractor verification testing, 72-hour continuous testing, and 30-day operational testing to assess system performance and alarm rates. Installation work will be performed at Hurlburt Field, Florida, specifically in Building #91650, with the contractor required to provide a one-year warranty on all installed equipment. The project involves installing eight High Security Switches sensors and five PIR sensors across the specified rooms, with strict adherence to multiple security and safety standards including DAFI 31-101, TIA/EIA telecommunications standards, and NFPA codes.
Notice text
5 versions
Update #5 · Latest ·
4 Sep 25: The pupose of this amendment is to:
1. Attach Questions and Answers
2. Attach Updated Statement of Work dated 4 Sep 2025
3. Attach Updated Addendum to 52.212-1 and 52.212-2 to fix clerical error on page one (1) Required Statements; new statment is as follows: "The Offeror must provide a statement that their proposal for the project is compliant with Attachment #7 Non-Nuclear Configuration Management Database (CMD) Equipment Approval Memorandum, dated 29 April 2024"
All other terms and conditions remain unchanged
26 Aug 25: Floor Plans from the Statement of Work have been uploaded as seperate files.
Amendment 0002 (25 Aug 25): The purpose of this amendment it to update Attachment 2 - Statement of Work (SOW). This update removes the requirement of ACS installation. Additioanlly, it expands the description of equipment in paragraph 1.3.1.
Amendment 0001 (20 Aug 25): The purpose of this amendment is to update Attachment 3 - Addendum to 52.212-1 and 52.212-2. The PSG VICADS Certification requirement was removed from the Technical Evaluation Factors of this requirement.
This is a compined synopsis/solcitation for the IDS Install for the 23rd STS and Hurlburt Field, FL.
The contractor shall install a Vindicator Intrusion detection system (IDS) and Hirsch Access Control (ACS) in building #91650/room 1238, 2024, 2014, 2031, 2027, compatible with Windows 10.
Update #4 ·
26 Aug 25: Floor Plans from the Statement of Work have been uploaded as seperate files.
Amendment 0002 (25 Aug 25): The purpose of this amendment it to update Attachment 2 - Statement of Work (SOW). This update removes the requirement of ACS installation. Additioanlly, it expands the description of equipment in paragraph 1.3.1.
Amendment 0001 (20 Aug 25): The purpose of this amendment is to update Attachment 3 - Addendum to 52.212-1 and 52.212-2. The PSG VICADS Certification requirement was removed from the Technical Evaluation Factors of this requirement.
This is a compined synopsis/solcitation for the IDS Install for the 23rd STS and Hurlburt Field, FL.
The contractor shall install a Vindicator Intrusion detection system (IDS) and Hirsch Access Control (ACS) in building #91650/room 1238, 2024, 2014, 2031, 2027, compatible with Windows 10.
Update #3 ·
Amendment 0002 (25 Aug 25): The purpose of this amendment it to update Attachment 2 - Statement of Work (SOW). This update removes the requirement of ACS installation. Additioanlly, it expands the description of equipment in paragraph 1.3.1.
Amendment 0001 (20 Aug 25): The purpose of this amendment is to update Attachment 3 - Addendum to 52.212-1 and 52.212-2. The PSG VICADS Certification requirement was removed from the Technical Evaluation Factors of this requirement.
This is a compined synopsis/solcitation for the IDS Install for the 23rd STS and Hurlburt Field, FL.
The contractor shall install a Vindicator Intrusion detection system (IDS) and Hirsch Access Control (ACS) in building #91650/room 1238, 2024, 2014, 2031, 2027, compatible with Windows 10.
Update #2 ·
Amendment 0001 (20 Aug 25): The purpose of this amendment is to update Attachment 3 - Addendum to 52.212-1 and 52.212-2. The PSG VICADS Certification requirement was removed from the Technical Evaluation Factors of this requirement.
This is a compined synopsis/solcitation for the IDS Install for the 23rd STS and Hurlburt Field, FL.
The contractor shall install a Vindicator Intrusion detection system (IDS) and Hirsch Access Control (ACS) in building #91650/room 1238, 2024, 2014, 2031, 2027, compatible with Windows 10.
Update #1 ·
This is a compined synopsis/solcitation for the IDS Install for the 23rd STS and Hurlburt Field, FL.
The contractor shall install a Vindicator Intrusion detection system (IDS) and Hirsch Access Control (ACS) in building #91650/room 1238, 2024, 2014, 2031, 2027, compatible with Windows 10.
Files
Show all 18
Notice history
| Notice | Type | Posted |
|---|---|---|
| This notice | Solicitation | |
| 23 STS compound IDS/ADS install | Pre-Solicitation |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| Electronic Security Systems | ACC Rock Island | Total Small Business |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity