1 flow cytometer to detect and measure the physical and chemical characteristics of a population of cells or particles.
Closed Special Notice Posted
- Solicitation number
- 80NSSC25897034Q
- Agency
-
Shared Services Center
National Aeronautics and Space Administration
- Responses due
- Set-aside
- No set-aside
Opportunity facts
- NAICS code
- 334516 Analytical Laboratory Instrument Manufacturing
- PSC
- 6640 Laboratory Equipment And Supplies
- Place of performance
- Houston, Texas 77058, United States
- Points of contact
Notice details come from SAM.gov. Updated .
About this opportunity
The National Aeronautics and Space Administration Shared Services Center (NASA/NSSC) has issued a Special Notice for the procurement of a flow cytometer designed to detect and measure physical and chemical characteristics of cell and particle populations. The notice represents a sole source procurement intended for Beckman Coulter, Inc., which NASA has determined to be the only capable source for this specialized scientific instrument. The procurement will be conducted under Federal Acquisition Regulation (FAR) 13.106-1(b)(1)(i) using commercial item procedures outlined in FAR Parts 12 and 13. The flow cytometer will be utilized at NASA Johnson Space Center (JSC) and falls under the Analytical Laboratory Instrument Manufacturing NAICS code 334516. The total procurement is for one advanced flow cytometer with specific technical requirements.
Contractors interested in demonstrating capability to perform this work must submit their capability statements by 1 p.m. Central Standard Time on March 11, 2025, to the designated point of contact, Cara Craft. NASA reserves discretion to determine whether to compete the requirement based on responses received, and oral responses will not be accepted. The flow cytometer must feature four specific lasers with precise wavelength and power specifications, including Violet (405nm/80mW), Blue (488nm/50mW), Yellow Green (561nm/30mW), and Red (638nm/50mW). The instrument requires fixed integrated optics, a quartz flow cell design with >1.3 numerical aperture, and specific scatter resolution capabilities. While this is currently positioned as a sole source procurement for Beckman Coulter, Inc., NASA is providing an opportunity for other potential contractors to demonstrate their technical capabilities through submitted capability statements.
Notice text
Please see the attached documents for details.
Files
| File | Type | Posted |
|---|---|---|
| SATPC0037770 Tab 07 Capability Statement FBO Posting.pdf | ||
| SATPC0037770 Tab 04 4 SOW .pdf |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| Combined Synopsis Solicitation- Acquire Flow Cytom | Office of Logisitics and Acquisition Operations | No set-aside | |
| Notice of Intent: Maintenance contract for FACS Aria flow cytometer | Office of Logisitics and Acquisition Operations | No set-aside | |
| MassTech Atmospheric Pressure Matrix-Assisted Laser Desorption/Ionization | Shared Services Center | No set-aside | |
| Flow Cytometry Reagents | Veterans Integrated Service Network 5 | No set-aside | |
| AN12--NOVOCYTE 3000 PM&R Services Intent to Sole Source | Veterans Integrated Service Network 22 | No set-aside |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity