Y25-718_Drawings.pdf
PDF 28 MB Posted
- Solicitation number
- Y25-718
- Issued by
- Orange County, Orlando City, Florida
About this file
These technical engineering drawings, prepared by Hanson Professional Services Inc., detail the electrical lighting renovation project for the Orange County Convention Center's (OCCC) West Building Overhead Catwalk Lighting Installation. The project involves comprehensive replacement of existing catwalk lighting across multiple halls (Halls A through F), which includes removing current lighting fixtures and installing new energy-efficient LED strip lighting fixtures. The project documents are dated July 10, 2024, and cover detailed demolition and renovation plans for various catwalk areas, with specific zoning and electrical specifications for each section.
The project's estimated cost is $1,695,671.00, with electronic bid submissions required through the OpenGov e-Procurement Platform by 4:00 pm EST on Tuesday, December 3, 2024. Bidders must submit questions by Monday, November 4, 2024, at 5:00 pm EST. The technical scope includes replacing existing catwalk lighting with new LED fixtures, implementing new lighting circuits, updating electrical panels and relay systems, and ensuring compliance with the 2023 Florida Building Code, Florida Energy Conservation Code, and National Electrical Code. The lighting renovation aims to optimize visibility and energy efficiency across the convention center's catwalk areas, with careful attention to mounting heights, electrical zoning, and existing building infrastructure.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Engineering | Planning | Allied Services
Offices Nationwide www.hanson-inc.com
Hanson Professional Services Inc.
CONSULTANTS
EB0007061
AA0003116
IB0001058
SHEET TITLE
REVIEWED BY:
DRAWN BY:
DESIGN BY:
PROJECT NO:
ISSUE:
© Copyright Hanson Professional Services Inc. 2024
54321 6
E
D
C
B
A
54321 6
MARK DATE DESCRIPTION
SEAL
/1
/2
:3 :5
A
M
A u to d e sk
D o c s /2
G
O C
C C
W e s t B ld g C a tw a lk
L ig h ti n g /O
C C
C W
E S
T B
L D
G C
A T
W A
L K
L
IG
H T
IN
G
R
.r v t
2300 Maitland Center Pkwy, Suite Maitland, FL 32751 407-790-7397
OCCC West Bldg Catwalk Lighting
9800 International Dr.
Orlando, FL 32819
COVER SHEET
G0.1
07/10/2024
23G0084
XT/BM
MB/ML
XT/AJT
100% CD
DRAWING INDEX
SHEET NO. SHEET NAME
G0.1 COVER SHEET
E0.1 GENERAL ELECTRICAL NOTES, LEGEND AND ABBREVIATIONS
E1.1 OVERALL LIGHTING PLAN - WEST BUILDING CATWALKS
ED1.A1.1 LIGHTING DEMOLITION PLAN - AREA A1.1
ED1.A1.2 LIGHTING DEMOLITION PLAN - AREA A1.2
ED1.A1.3 LIGHTING DEMOLITION PLAN - AREA A1.3
ED1.A2.1 LIGHTING DEMOLITION PLAN - AREA A2.1
ED1.A2.2 LIGHTING DEMOLITION PLAN - AREA A2.2
ED1.A2.3 LIGHTING DEMOLITION PLAN - AREA A2.3
ED1.A3.1 LIGHTING DEMOLITION PLAN - AREA A3.1
ED1.A3.2 LIGHTING DEMOLITION PLAN - AREA A3.2
ED1.A3.3 LIGHTING DEMOLITION PLAN - AREA A3.3
ED1.A4.1 LIGHTING DEMOLITION PLAN - AREA A4.1
ED1.A4.2 LIGHTING DEMOLITION PLAN - AREA A4.2
ED1.A4.3 LIGHTING DEMOLITION PLAN - AREA A4.3
ED1.B1.1 LIGHTING DEMOLITION PLAN - AREA B1.1
ED1.B1.2 LIGHTING DEMOLITION PLAN - AREA B1.2
ED1.B1.3 LIGHTING DEMOLITION PLAN - AREA B1.3
ED1.B2.1 LIGHTING DEMOLITION PLAN - AREA B2.1 & B3.1
ED1.B2.2 LIGHTING DEMOLITION PLAN - AREA B2.2 & B3.2
ED1.B2.3 LIGHTING DEMOLITION PLAN - AREA B2.3 & B3.3
ED1.B4.1 LIGHTING DEMOLITION PLAN - AREA B4.1
ED1.B4.2 LIGHTING DEMOLITION PLAN - AREA B4.2
ED1.B4.3 LIGHTING DEMOLITION PLAN - AREA B4.3
ED1.C1.1 LIGHTING DEMOLITION PLAN - AREA C1.1
ED1.C1.2 LIGHTING DEMOLITION PLAN - AREA C1.2
ED1.D1.1 LIGHTING DEMOLITION PLAN - AREA D1.1
ED1.D1.2 LIGHTING DEMOLITION PLAN - AREA D1.2
ED1.D2.1 LIGHTING DEMOLITION PLAN - AREA D2.1
ED1.D2.2 LIGHTING DEMOLITION PLAN - AREA D2.2
ED1.D2.3 LIGHTING DEMOLITION PLAN - AREA D2.3
ED1.D2.4 LIGHTING DEMOLITION PLAN - AREA D2.4
ED1.E1.1 LIGHTING DEMOLITION PLAN - AREA E1.1
ED1.E1.2 LIGHTING DEMOLITION PLAN - AREA E1.2
ED1.E2.1 LIGHTING DEMOLITION PLAN - AREA E2.1
ED1.E2.2 LIGHTING DEMOLITION PLAN - AREA E2.2
ED1.F1.1 LIGHTING DEMOLITION PLAN - AREA F1.1
ED1.F1.2 LIGHTING DEMOLITION PLAN - AREA F1.2
E1.A1.1 LIGHTING RENOVATION PLAN - AREA A1.1
E1.A1.2 LIGHTING RENOVATION PLAN - AREA A1.2
E1.A1.3 LIGHTING RENOVATION PLAN - AREA A1.3
E1.A2.1 LIGHTING RENOVATION PLAN - AREA A2.1
E1.A2.2 LIGHTING RENOVATION PLAN - AREA A2.2
E1.A2.3 LIGHTING RENOVATION PLAN - AREA A2.3
E1.A3.1 LIGHTING RENOVATION PLAN - AREA A3.1
E1.A3.2 LIGHTING RENOVATION PLAN - AREA A3.2
E1.A3.3 LIGHTING RENOVATION PLAN - AREA A3.3
E1.A4.1 LIGHTING RENOVATION PLAN - AREA A4.1
E1.A4.2 LIGHTING RENOVATION PLAN - AREA A4.2
E1.A4.3 LIGHTING RENOVATION PLAN - AREA A4.3
E1.B1.1 LIGHTING RENOVATION PLAN - AREA B1.1
E1.B1.2 LIGHTING RENOVATION PLAN - AREA B1.2
E1.B1.3 LIGHTING RENOVATION PLAN - AREA B1.3
E1.B2.1 LIGHTING RENOVATION PLAN - AREA B2.1 & B3.1
E1.B2.2 LIGHTING RENOVATION PLAN - AREA B2.2 & B3.2
E1.B2.3 LIGHTING RENOVATION PLAN - AREA B2.3 & B3.3
E1.B4.1 LIGHTING RENOVATION PLAN - AREA B4.1
E1.B4.2 LIGHTING RENOVATION PLAN - AREA B4.2
E1.B4.3 LIGHTING RENOVATION PLAN - AREA B4.3
E1.C1.1 LIGHTING RENOVATION PLAN - AREA C1.1
E1.C1.2 LIGHTING RENOVATION PLAN - AREA C1.2
E1.D1.1 LIGHTING RENOVATION PLAN - AREA D1.1
E1.D1.2 LIGHTING RENOVATION PLAN - AREA D1.2
E1.D2.1 LIGHTING RENOVATION PLAN - AREA D2.1
E1.D2.2 LIGHTING RENOVATION PLAN - AREA D2.2
E1.D2.3 LIGHTING RENOVATION PLAN - AREA D2.3
E1.D2.4 LIGHTING RENOVATION PLAN - AREA D2.4
E1.E1.1 LIGHTING RENOVATION PLAN - AREA E1.1
E1.E1.2 LIGHTING RENOVATION PLAN - AREA E1.2
E1.E2.1 LIGHTING RENOVATION PLAN - AREA E2.1
E1.E2.2 LIGHTING RENOVATION PLAN - AREA E2.2
E1.F1.1 LIGHTING RENOVATION PLAN - AREA F1.1
E1.F1.2 LIGHTING RENOVATION PLAN - AREA F1.2
E5.0 ELECTRICAL DETAILS
E6.0 POWER AND RELAY PANEL SCHEDULES - HALL A
E6.1 POWER AND RELAY PANEL SCHEDULES - HALL B
E6.2 POWER AND RELAY PANEL SCHEDULES - HALL C & D
E6.3 POWER AND RELAY PANEL SCHEDULES - HALL D, E & F
E7.1 POWER AND RELAY RISER - HALL A
E7.2 POWER AND RELAY RISER - HALL B AND C
E7.3 POWER AND RELAY RISER - HALL D
E7.4 POWER AND RELAY RISER - HALL E AND F
9800 International Dr.
Orlando, FL 32819
100% CD
JULY 10, 2024
OCCC West Bldg Catwalk Lighting
HANSON PROFESSIONAL SERVICES INC.
2300 Maitland Center Pkwy, Suite 310
Maitland, FL 32751 407-790-7397
CODES IN EFFECT AT TIME OF DRAWING SUBMITTAL
FLORIDA BUILDING CODE, EIGHTH EDITION (2023)
FLORIDA ENERGY CONSERVATION CODE, EIGHTH EDITION (2023)
FLORIDA FIRE PREVENTION CODE, EIGHTH EDITION (2023)
NFPA 1 FIRE CODE, 2021 EDITION
NFPA 101 (LIFE SAFETY CODE) 2021 EDITION WITH FL AMENDMENTS
NEC (NFPA 70) 2020 EDITION
TO THE BEST OF THE ENGINEER'S KNOWLEDGE, THE PLANS AND
SPECIFICATIONS COMPLY WITH THE 2023 FLORIDA BUILDING CODE
WITH ALL CURRENT AMENDMENTS.
PROJECT INFORMATION
SCOPE OF WORK
ELECTRICAL:
THE SCOPE OF WORK FOR THE OCCC CATWALK LIGHTING
REPLACEMENT PROJECT INVOLVES UPGRADING THE EXISTING
LIGHTING SYSTEM ON THE CATWALKS IN HALL A, HALL B, HALL C,
HALL D, HALL E, AND HALL F IN THE WEST CONCOURSE. THIS
EFFORT ENCOMPASSES THE REMOVAL OF THE CURRENT
LIGHTING FIXTURES AND THE INSTALLATION OF NEW, ENERGY-
EFFICIENT LED FIXTURES. A COMPREHENSIVE LIGHTING DESIGN
IS IMPLEMENTED TO OPTIMIZE VISIBILITY ON THE CATWALKS.
THE PROJECT WILL ALSO INCLUDE THE NECESSARY ELECTRICAL
AND CONTROL MODIFICATIONS TO SUPPORT THE UPGRADED
LIGHTING SYSTEM.
MEP ENGINEERS
PROJECT LOCATION
COUNTY PROJECT No. 0966-58
ORANGE COUNTY MAYOR
Jerry L. Demings
DISTRICT 1 COMMISSIONER
Nicole H. Wilson
DISTRICT 2 COMMISSIONER
Christine Moore
DISTRICT 5 COMMISSIONER
Emily Bonilla
DISTRICT 6 COMMISSIONER
Michael "Mike" Scott
DISTRICT 4 COMMISSIONER
Maribel Gomez Cordero
DISTRICT 3 COMMISSIONER
Mayra Uribe
NOTE: SOME SYMBOLS SHOWN IN ELECTRICAL LEGEND
MAY NOT APPLY TO THIS PROJECT.
ELECTRICAL SYMBOL LEGEND
ELECTRICAL SYMBOL NOTES
ALL DISTANCES ARE TO CENTER OF DEVICE OR EQUIPMENT UNLESS OTHERWISE NOTED. DEVICES INDICATED AT 48" MAY NOT BE INSTALLED WITH ANY OPERABLE PART HIGHER THAN 48". DEVICES MAY BE INSTALLED IN CONCRETE MASONRY UNITS WITH THE TOP OF THE DEVICE AT 48".
** DISTANCE TO TOP OF EQUIPMENT OR DEVICE
PP2
LIGHT FIXTURE LABELING. "PP2" INDICATES PANEL, "8" INDICATES CIRCUIT NUMBER(S), "<C>" INDICATES
ZONE, "A" INDICATES FIXTURE TYPE. MOUNTING HEIGHT INDICATED TO BOTTOM OF FIXTURE.
PANELBOARDS. PANELBOARD DOORS MAY BE SHOWN TO INDICATE OPENING SIDE OF
RECESSED PANELBOARDS. SEE PANELBOARD IDENTIFICATION FOR DESIGNATION CODES.
SYMBOL NOTATIONS: UPPER CASE LETTERS ADJACENT TO SYMBOLS INDICATE A UNIT
TYPE. SEE APPROPRIATE SCHEDULE OR SPECIFICATIONS.
A<C>
PP2-8
8'-0"
ELECTRICAL GENERAL NOTES
1. ALL ELECTRICAL WORK SHALL COMPLY WITH THE 2020 NATIONAL ELECTRICAL CODE, THE FLORIDA BUILDING CODE, THE NATIONAL FIRE CODES, STATE REQUIREMENTS AND ALL APPLICABLE LOCAL
CODES AND ORDINANCES.
2. SEE SPECIFICATIONS FOR ADDITIONAL INFORMATION AND ALL REQUIREMENTS NOT INDICATED ON THE
DRAWINGS.
3. IT IS THE INTENT OF THESE PLANS AND SPECIFICATIONS THAT A COMPLETE AND WORKABLE ELECTRICAL INSTALLATION BE PROVIDED FOR ALL THE EQUIPMENT DESCRIBED OR SHOWN AS BEING IN THIS CONTRACT. ANY ITEMS WHICH ARE CLEARLY NECESSARY FOR THE COMPLETION OF THE WORK OR ITS APPURTENANCES SHALL BE CONSIDERED A PORTION OF THE WORK AND SHALL BE PROVIDED AND
INSTALLED BY THE CONTRACTOR EVEN THOUGH NOT DIRECTLY SPECIFIED.
4. THE PLANS AND SPECIFICATIONS ARE COMPLIMENTARY, AND THAT WHICH IS CALLED FOR BY ONE SHALL BE AS BINDING AS IF CALLED FOR BY BOTH. IN THE EVENT THAT THE PLANS AND SPECIFICATIONS CONFLICT, THE MORE STRINGENT SHALL APPLY. ANY DISCREPANCIES IN THE DRAWINGS SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE DESIGN PROFESSIONAL PRIOR TO SUBMITTAL OF BID.
5. THE PLANS INDICATE THE GENERAL ARRANGEMENT OF THE WORK TO BE PERFORMED AND ARE DIAGRAMMATIC ONLY. ALL DIMENSIONS AND EQUIPMENT LOCATIONS SHALL BE VERIFIED IN THE FIELD.
6. VISIT AND CAREFULLY EXAMINE THOSE PORTIONS OF THE BUILDING AND SITE AFFECTED BY THIS WORK BEFORE SUBMITTING PROPOSALS, SO AS TO BECOME FAMILIAR WITH EXISTING CONDITIONS AND DIFFICULTIES THAT WILL AFFECT EXECUTION OF THE WORK. SUBMISSION OF A PROPOSAL WILL BE CONSTRUED AS EVIDENCE THAT SUCH EXAMINATION HAS BEEN MADE AND LATER CLAIMS FOR LABOR, EQUIPMENT OR MATERIALS REQUIRED BECAUSE OF DIFFICULTIES ENCOUNTERED WILL NOT BE
RECOGNIZED.
7. THE CONTRACTOR SHALL THOROUGHLY REVIEW THE PROJECT TO ENSURE THAT ALL WORK SHALL MEET OR EXCEED THE ABOVE REQUIREMENTS. ANY ALLEGED DISCREPANCIES SHALL BE BROUGHT TO
THE OWNER'S AND ENGINEER'S ATTENTION PRIOR TO THE START OF WORK.
8. THE CONTRACTOR IS DIRECTED TO OBTAIN COPIES OF ALL RELATED PLANS, SPECIFICATIONS, SHOP
DRAWINGS AND ADDENDUM TO COORDINATE THE RELATED WORK AND SCHEDULING.
9. VERIFY EXISTING CONDITIONS IN FIELD AND COORDINATE WITH ALL TRADES PRIOR TO INSTALLING OR
FABRICATING EQUIPMENT.
10. DRAWINGS ARE DIAGRAMMATIC IN NATURE. COORDINATE EXACT LOCATION OF ALL CEILING MOUNTED EQUIPMENT SO ALL SERVICEABLE COMPONENTS CAN BE EASILY ACCESSED. REMOVAL OR RELOCATION
OF LIGHTING FIXTURES FOR SERVICE ACCESS IS NOT ACCEPTABLE. THE CONTRACTOR SHALL
REINSTALL EQUIPMENT THAT HAS INADEQUATE OR UNSAFE ACCESSIBILITY. LOCATE ALL OTHER
EQUIPMENT WITH MANUFACTURER RECOMMENDED ACCESS FOR OPERATION AND MAINTENANCE.
11. CONTRACTOR SHALL NOT CONCEAL ANY WORK UNTIL INSPECTED BY ELECTRICAL INSPECTOR AND ENGINEER. CONTRACTOR SHALL NOTIFY ENGINEER OF A SCHEDULED INSPECTION TIME WITHIN 72
HOURS. GENERAL CONTRACTOR SHALL NOT CONCEAL WORK UNTIL INSPECTED AND APPROVED,
REGARDLESS OF SCHEDULE.
12. PRIME CONTRACTOR IS RESPONSIBLE TO HAVE LICENSED AND QUALIFIED SUBCONTRACTORS
PERFORMING ALL WORK.
13. ALL CHANGES MADE IN THE FIELD SHALL BE RECORDED BY THE CONTRACTOR(S) ON AS-BUILT
DRAWINGS, SHOP DRAWINGS, AND IN MAINTENANCE MANUALS.
14. THE SIZE, LOCATION AND ELECTRICAL REQUIREMENTS AND SERVICE CLEARANCES OF EQUIPMENT INSTALLED UNDER DIVISION 26, ELECTRICAL, SHALL BE COORDINATED WITH ALL OTHER TRADES.
15. WHERE CROWDED LOCATIONS EXIST OR WHERE THERE IS A POSSIBILITY OF CONFLICT BETWEEN
TRADES, CONTRACTOR SHALL MAKE COMPOSITE DRAWINGS SHOWING THE EXACT LOCATION OF
PANELBOARDS, SWITCHBOARDS, TRANSFORMERS, CONDUIT AND EQUIPMENT AND MECHANICAL PIPING, DUCTWORK, AND OTHER ARCHITECTURAL APPURTENANCES. DRAWINGS SHALL BE BASED ON FIELD
MEASUREMENTS AND, AFTER CONSULTATION AND AGREEMENT BETWEEN THE TRADES, SHALL BE
APPROVED BY THE ARCHITECT/ENGINEER PRIOR TO INSTALLATION OF THE WORK.
16. NOTIFY ENGINEER OF ANY CONFLICTS PRIOR TO PURCHASING EQUIPMENT AND PRIOR TO CUTTING
OPENINGS.
17. ALL BARE METAL SURFACES SHALL BE PRIMED AND PAINTED BLACK TO PREVENT ANY RUST, INCLUDING, BUT NOT LIMITED TO, ANGLE FRAMING, UNIT SUPPORTS, MOUNTING HARDWARE, ETC.
18. ALL WORK SHALL BE CONSTRUCTED TO MEET ANY PHASING REQUIREMENTS OF THE PROJECT AS MAY
BE OUTLINED IN THE DRAWINGS AND/OR SPECIFICATIONS.
19. RACEWAYS AND ELECTRICAL EQUIPMENT HAVE BEEN LOCATED AND ARRANGED TO MINIMIZE THE
INTERFERENCE OF EQUIPMENT WITH THE STRUCTURE. THE CONTRACTOR SHALL THOROUGHLY
FAMILIARIZE THEMSELVES WITH THE WORK TO BE PERFORMED BY OTHER TRADES AND THE PHYSICAL CHARACTERISTICS OF THE STRUCTURE IN ORDER TO SCHEDULE AND INSTALL EQUIPMENT AND TO MINIMIZE POSSIBLE INTERFERENCE. FAILURE TO PROPERLY COMMUNICATE AND SCHEDULE WORK WITH OTHER TRADES RESULTING IN ADDITIONAL WORK AND MATERIAL, SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. THE MODIFICATIONS REQUIRED TO RESOLVE THE CONFLICT SHALL BE DECIDED BY
THE OWNER AND THE COST OF THE MODIFICATIONS SHALL BE BORNE BY THE CONTRACTOR.
20. ALL PANELBOARDS AND RELAY PANELS SHALL BE PROVIDED WITH AN UPDATED PRINTED DIRECTORY
SHOWING CIRCUIT NUMBERS AND A COMPLETE DESCRIPTION OF EACH CIRCUIT. HANDWRITTEN
SCHEDULES ARE PROHIBITED.
21. MINIMUM TRADE SIZE CONDUIT PERMITTED SHALL BE 3/4 INCH UNLESS NOTED OTHERWISE. TYPE AC AND TYPE MC CABLE SHALL NOT BE PERMITTED FOR USE ANYWHERE EXCEPT FOR LIGHTING FIXTURE WHIPS. ALL CONDUITS, INCLUDING TYPE AC AND TYPE MC CABLE, SHALL BE PAINTED BLACK.
22. ALL SECONDARY FEEDERS AND BRANCH CIRCUIT CONDUCTORS SHALL BE COPPER WITH 600 VOLT INSULATION TYPE THHN, THW OR THWN. (MINIMUM SIZE SHALL BE NO. 12 AWG.) CONTRACTOR SHALL PROVIDE AND INSTALL ALL PHASE (A, B, C, AS REQUIRED) CONDUCTORS, NEUTRAL CONDUCTORS, AND
GROUND CONDUCTORS AS NECESSARY FOR A COMPLETE AND OPERABLE SYSTEM. NO INDIVIDUAL
CONDUCTOR SPECIFICATION SHALL BE CONSTRUED AS REQUIRING ONLY ONE CONDUCTOR. A
COMPLETE AND OPERABLE SYSTEM IS INTENDED BY THE CONSTRUCTION DOCUMENTS AND THE
CONTRACTOR SHALL PROVIDE AND INSTALL ALL NECESSARY WIRING AND CONDUCTORS AS REQUIRED
TO DELIVER A COMPLETE AND OPERABLE ELECTRICAL SYSTEM TO THE OWNER. NO ADDITIONAL
COMPENSATION WILL BE MADE TO THE CONTRACTOR FOR UNDER-ESTIMATING AND/OR MIS-
CALCULATING THEIR WIRING AND CABLING RESPONSIBILITIES.
23. ALL CONDUITS SHALL HAVE A SEPARATE GREEN GROUND CONDUCTOR INSTALLED FOR GROUNDING.
24. ALL FEEDER AND BRANCH CIRCUIT CONDUCTORS SHALL BE SIZED NOT TO EXCEED THE MAXIMUM
VOLTAGE DROP ALLOWED IN ACCORDANCE WITH THE 2023 FLORIDA BUILDING CODE, ENERGY
CONSERVATION, CHAPTER 4, SECTION C405.5.3. THE ELECTRICAL CONTRACTOR SHALL CALCULATE VOLTAGE DROP AND ADJUST CONDUCTORS AS NEEDED. FOR DESIGN LOADS, A MAXIMUM VOLTAGE DROP OF 2% IS PERMITTED FOR FEEDER CONDUCTORS AND A MAXIMUM VOLTAGE DROP OF 3% IS
PERMITTED FOR BRANCH CIRCUIT CONDUCTORS. CONTRACTOR SHALL NOT DECREASE CONDUCTOR
SIZES NOTED ON PLAN. CONTRACTOR SHALL ONLY INCREASE CONDUCTOR SIZES NOTED IF NEEDED TO MEET MINIMUM CODE REQUIREMENTS. PROVIDE COMPRESSION TYPE CONDUCTOR REDUCING PIN FOR FINAL TERMINATION OF CONDUCTORS OVERSIZED FOR VOLTAGE DROP OR OTHER DERATING WHERE CONDUCTOR IS TOO LARGE FOR FINAL TERMINATION. OVERSIZED CONDUCTORS FOR VOLTAGE DROP MAY BE REDUCED WITHIN 48” OF OVERCURRENT PROTECTION DEVICE AND WITHIN 48” OF EQUIPMENT TO ACCOMMODATE TERMINATION RATING. WIRE SIZE SHALL NOT BE LESS THAN THE LARGEST WIRE OF TERMINATION RATING RANGE. WIRE SIZE SHALL NOT BE REDUCED LESS THAN THE RATING OF THE
OVERCURRENT PROTECTION DEVICE, NOR LESS THAN REQUIRED BY THE NEC INCLUDING ALL
REQUIRED DERATING (E.G. AMBIENT HEAT, CONDUCTORS PER RACEWAY, ETC).
25. FOR MULTI-WIRE BRANCH CIRCUITS, ADD SEPARATE NEUTRALS OR PROVIDE & INSTALL MULTI-POLE
CIRCUIT BREAKERS PER 2020 NEC, ARTICLE 210.4.
26. ALL ELECTRICAL EQUIPMENT FEEDERS, BRANCH CIRCUIT CONDUCTORS, AND DEVICE AND EQUIPMENT
TERMINATIONS SHALL BE RATED FOR A MINIMUM OF 75ºC UNLESS OTHERWISE NOTED.
27. ADJACENT AREAS OPEN TO FLOOR BELOW AND SUBJECT TO DAMAGE FROM FALLING MATERIALS.
CLEAR ALL MOVABLE FURNITURE AND MATERIALS BELOW WORK AREA PRIOR TO DEMOLITION AND
CONSTRUCTION ACTIVITIES. PROVIDE BARRICADES, SIGNAGE, OR OTHER PERSONNEL ACCESS
CONTROLS BELOW WORK AREAS. PROVIDE PROTECTIVE FLOOR COVERS OR OTHER MEASURES TO
PREVENT DAMAGE FROM HEAVY AND/OR SHARP OBJECTS ACCIDENTALLY FALLING FROM WORK AREA.
FLOOR COVERING SHALL BE THICK RUBBER SHEETS, CARPET, CORRUGATED PLASTIC, OR OTHER MATERIAL CAPABLE OF ABSORBING SHOCK, CUTS, PIERCING FROM FALLING DEBRIS. CONTRACTOR SHALL BE RESPONSIBLE FOR ANY AND ALL DAMAGE FROM FALLING DEBRIS WHILE IN CONTROL OF WORK AREAS. CONTRACTOR SHALL RESTORE AREA BELOW WORK AREA TO ORIGINAL CONDITION UPON
COMPLETION OF WORK.
28. CONTRACTOR IS RESPONSIBLE FOR OSHA WORKER SAFETY COMPLIANCE AND ALL REQUIRED
EMPLOYEE'S PERSONAL PROTECTIVE EQUIPMENT (PPE) AS WELL AS ASSOCIATED TRAINING, INCLUDING BUT NOT LIMITED TO FALL PROTECTION, LOCK-OUT TAG-OUT, ETC. CONTRACTOR EMPLOYEES NOT
COMPLYING WITH REQUIRED WORKER SAFETY PROTOCOLS MAY BE REQUESTED TO LEAVE THE
PROJECT AND MAY NOT BE ALLOWED BACK ON SITE WITHOUT ADDITIONAL OSHA TRAINING.
ASC - APPLICATION SPECIFIC CONTROLLER
ATC - AUTOMATIC TEMPERATURE CONTROL
FAAP - FIRE ALARM ANNUNCIATOR PANEL
GAP - GENERATOR ANNUNCIATOR PANEL
FT - FOOT OR FEET
HP - HORSE POWER
FTU - FAN TERMINAL UNIT
GFI - GROUND FAULT INTERRUPTING
GND - GROUND
HZ - HERTZ (CYCLES PER SECOND)
FCU - FAN COIL UNIT
FLA - FULL LOAD AMPS
EM - EMERGENCY
EWC - ELECTRIC WATER COOLER
EWH - ELECTRIC WATER HEATER
EX - EXISTING
EXTR - EXISTING TO REMAIN
°F - DEGREES FAHRENHEIT
FACP - FIRE ALARM CONTROL PANEL
FATC - FIRE ALARM TERMINAL CABINET
EPO - EMERGENCY POWER OFF
CT - COOLING TOWER
dB - DECIBELS
EF - EXHAUST FAN
EDH - ELECTRIC DUCT HEATER
ELEC - ELECTRIC OR ELECTRICAL
°C - DEGREES CENTIGRADE/CELSIUS
C - CONDUIT
CB - CIRCUIT BREAKER
CCTV - CLOSED CIRCUIT TELEVISION
D/D - DUSK TO DAWN
CONC - CONCRETE
COND - CONDUCTOR
DN - DOWN
AC - ALTERNATING CURRENT
AFG - ABOVE FINISHED GRADE
ATS - AUTOMATIC TRANSFER SWITCH
BG - BELOW GRADE
ABCLG - ABOVE CEILING
APPROX - APPROXIMATELY
BLDG - BUILDING
A/C - AIR CONDITIONING
AHU - AIR HANDLING UNIT
AFF - ABOVE FINISHED FLOOR
AL - ALUMINUM
PTAC - PACKAGED TERMINAL AIR CONDITIONER
UNO - UNLESS NOTED OTHERWISE
WH - WATER HEATER
VAV - VARIABLE AIR VOLUME
VFD - VARIABLE FREQUENCY DRIVE
WP - WEATHERPROOF
TYP - TYPICAL
RLA - RUNNING LOAD AMPS
SHT - SHEET
SF - SUPPLY FAN
RTU - ROOF TOP UNIT
UGE - UNDERGROUND ELECTRIC
TTC - TELEPHONE TERMINAL CABINET
TTB - TELEPHONE TERMINAL BOARD
SCP - SECURITY CONTROL PANEL
R - RELOCATE
IDF - INTERMEDIATE DISTRIBUTION FRAME
MTD - MOUNTED
POAU - PACKAGED OUTDOOR AIR UNIT
OAU - OUTDOOR AIR HANDLING UNIT
P - PUMP
PH - PHASE
NTS - NOT TO SCALE
OHE - OVERHEAD ELECTRIC
NO - NORMALLY OPEN
NL - NIGHT LIGHT
NF - NON-FUSED
NIC - NOT IN CONTRACT
NC - NORMALLY CLOSED
LRA - LOCKED ROTOR AMPS
MCA - MINIMUM CIRCUIT AMPACITY
MIN - MINIMUM
REF - REFRIGERATOR
MAX - MAXIMUM
KW - KILOWATT
LA - LIGHTNING ARRESTOR
MH - MANHOLE
MDF - MAIN DISTRIBUTION FRAME
MB - MAIN BREAKER
IN - INCHES
MLO - MAIN LUGS ONLY
U.N.O. - UNLESS NOTED OTHERWISE
ST - SHUNT TRIP
ABBREVIATIONS
MMS - MANUAL MOTOR STARTER
LIGHTING FIXTURE, WALL MOUNTED
LIGHTING STRIP FIXTURE
LIGHTING FIXTURE
DESCRIPTIONHT AFF SYMBOL
AS NOTED
LIGHTING
WALL MOUNTED LIGHTING FIXTURE
72"* CIRCUIT BREAKER PANEL
72"*
72"*
T1
POWER OR DISTRIBUTION PANEL
TRANSFORMER (TYPE DENOTED)
SPECIAL CABINET
EQUIPMENT
SHEET NOTE. SEE THE SPECIAL NOTES ON
THAT SHEET FOR THE NOTE NUMBER
INDICATED IN THE HEXAGON.
ITEMS SHOWN DASHED AND RELATIVELY LIGHT
ARE EXISTING UNLESS NOTED OTHERWISE
REVISION CLOUD AND REFERENCE NUMBER
ROOM NUMBERS
EQUIPMENT DESIGNATION
TOP = EQUIPMENT TAG
BOTTOM = EQUIPMENT NUMBER
TAG
GENERAL SYMBOLS
TAG-# OR
Engineering | Planning | Allied Services
Offices Nationwide www.hanson-inc.com
Hanson Professional Services Inc.
CONSULTANTS
EB0007061
AA0003116
IB0001058
SHEET TITLE
REVIEWED BY:
DRAWN BY:
DESIGN BY:
PROJECT NO:
ISSUE:
© Copyright Hanson Professional Services Inc. 2024
54321 6
E
D
C
B
A
54321 6
MARK DATE DESCRIPTION
SEAL
/1
/2
:3 :2
A
M
A u to d e sk
D o c s /2
G
O C
C C
W e s t B ld g C a tw a lk
L ig h ti n g /O
C C
C W
E S
T B
L D
G C
A T
W A
L K
L
IG
H T
IN
G
R
.r v t
2300 Maitland Center Pkwy, Suite Maitland, FL 32751 407-790-7397
OCCC West Bldg Catwalk Lighting
9800 International Dr.
Orlando, FL 32819
GENERAL
ELECTRICAL NOTES,
LEGEND AND
ABBREVIATIONS
E0.1
07/10/2024
23G0084
XT/BM
MB/ML
XT/AJT
100% CD
LIGHTING FIXTURE SCHEDULE
TAG DESCRIPTION
LIGHT SOURCE MANUFACTURER
WATTS VOLT NOTES
TYPE LUMENS CCT CRI NAME CATALOG NO.
S1 4FT LED LINEAR STRIP, PENDANT CHAIN MOUNTED, WIRE GUARD,
MATTE BLACK FINISH
LED 3000 4000K 80 DAY-BRITE FSS430L840-UNV-DIM-FKR-126-BK-FS
SWG4
22 277 V 1,2
S2 8FT LED LINEAR STRIP, PENDANT CHAIN MOUNTED, WIRE GUARD,
MATTE BLACK FINISH
LED 6000 4000K 80 DAY-BRITE FSS830L840-UNV-DIM
FKR126-BK-FSSWG4
44 277 V 1,2
W1 2FT LED LINEAR STRIP, WALL MOUNTED, WIRE GUARD, MATTE
BLACK FINISH
LED 3000 4000K 80 DAY-BRITE FSS230L840-UNV-DIM-BK-FSSWG4 25 277 V 1,2,3
NOTES:
1. MANUFACTURER’S NAMES AND MODEL NUMBERS MAY BE GIVEN FOR DESCRIPTIVE PURPOSES,TO INDICATE A LEVEL OF QUALITY AND ARE NOT INTENDED TO LIMIT PRODUCTS TO A
SINGLE MANUFACTURER. PRODUCTS MUST BE DEEMED “EQUAL” AND APPROVED BY THE ENGINEER DURING SUBMITTAL REVIEW PRIOR TO PURCHASE.
2. REFER TO SHEET E5.0 FOR MOUNTING DETAILS.
3. CONTRACTOR TO PROVIDE AND INSTALL FIELD FABRICATED METAL SUPPORT TO MOUNT FIXTURE AT 45 DEGREES TOWARD CATWALK. SUPPORT TO BE ABLE TO WITHSTAND 5 TIMES THE
WEIGHT OF LIGHTING FIXTURE.
DN
E.F.H.
E.F.H.
UP
E.F.H.
E.F.H.
UP
U P
Dock 4Dock 5 Hall D2Hall D1
Lobby
Non Rigging Area Non Rigging Area Non Rigging Area Non Rigging Area Non Rigging Area
Non Rigging Area Non Rigging Area Non Rigging Area Non Rigging Area Non Rigging Area
ATRIUM OPEN TO BELOW ATRIUM OPEN TO BELOW
OPEN TO BELOW
CHAPIN
THEATER
W420
B A
L C
O N
Y
W
A
B
C
D
O P
E N
T O
B E
L O
W
ROOF
ROOF ROOF
ROOF
BOTTOM
C ON T R OL LE R
10" 3'- 6" 4'- 0"
8'- 3"
6'-
1"
7'- 0"
1'-
1" 3'-
6" 2'-
7"
5'- 7"
11'- 0"
8'- 2"
9'-
2"
5'- 6"
7'- 6"
8'- 6"
11'- 9"
7'-5 1/ 4"
9'-
4"
5'-
3/
6"
3CW-173CW-18
NEW STAIR
ELEVATOR
NEW
ELEVATOR
NO. 7
NEW
ELEVATOR
NO. 6
MECHANICAL ROOM
MULTI-PURPOSE ROOM BELOW
LADDER RM.
MECHANICAL ROOM
MECHANICAL ROOM
MEETING ROOM BELOW
ELEV. LOBBY
STAIR
NO. 7
AHU #64 AHU #35
AHU #34AHU #29
AHU #37
AHU #33
AHU #67
AHU #65
AHU #31
AHU #27
AHU #30
SHOW POWER
AHU #69
AHU #68
AHU #26
AHU #28
EXHIBIT HALL BELOW
EXHIBIT HALL BELOW
EXHIBIT HALL BELOW
EXHIBIT HALL BELOW
AHU #66
ELEVATOR
NO 2
STAIR
NO. 8
STAIR NO. 9
STAIR NO. 11
3V
3M04
3M03
3M05
3M06
3M01 3M73
3MCW-4 3MCW-6
3MCW-73MCW-5
3MCW-1
3MCW-2
3MCW-8
3MCW-11
3MCW-10
3MCW-9
3MCW-12
3MCW-13
3MCW-14
3MCW-15
3MCW-16
3MCW-17
3MCW-3
377-1
3M96
3M08-1
3M17-1
CONTROLLER CONTROLLER CONTROLLER
GALLERY
C W
3CW-10
OPEN TO BELOW OPEN TO BELOW
OPEN TO BELOW
ROOF NIC
ROOF NIC
ROOF NIC
ROOF NIC
OPEN TO BELOW
OPEN TO BELOW
OPEN TO BELOW
OPEN TO BELOW
OPEN TO BELOW
OPEN TO BELOW
OPEN TO BELOW
OPEN TO BELOW
OPEN TO BELOWOPEN TO BELOW
OPEN TO BELOW
3M03
3M04A
3M04B
C W
C W
C W
C W
C W
C W
C W
3CW-33CW-2
C W
M
3M02
3M17-1
M
M C W
C W
3MCW-14
3CW-53CW-4
3MCW-12
M C W
3MCW-11
3CW-16
M
3MCW-8
M C W
M C W
3MCW-3
M C W
3MCW-5
M C W
M C W
3MCW-15
M C W
M C W
M C W
AHU #29
AHU #65
MECHANICAL ROOM
MULTI-PURPOSE ROOM BELOW
EXHIBIT HALL BELOW
LADDER RM.
MECHANICAL ROOM
MECHANICAL ROOM
MECHANICAL ROOM
MEETING ROOM BELOW
ELEVATOR
NO. 5
STAIR NO. 1
CATWALK LANDING
ELEV. LOBBY
STAIR
NO. 7
STAIR
NO. 8
STAIR NO. 9
STAIR NO. 11
AHU #64 AHU #35
AHU #34AHU #29
AHU #37
AHU #33
AHU #67
AHU #65
AHU #31
AHU #27
AHU #30
AHU #53
AHU #69
AHU #68
AHU #26
AHU #28
EXHIBIT HALL BELOW
EXHIBIT HALL BELOW
EXHIBIT HALL BELOW
EXHIBIT HALL BELOW
EXHIBIT HALL BELOW
EXHIBIT HALL BELOW
AHU #66
AHU #32
ELEVATOR
NO 2
ELEVATOR
NO. 3
ELEVATOR
NO. 4
STAIR
NO. 12
3MCW-5
3MCW-11
3M04
3M03
3M02
3M05
3M06
316-1
3M08-2
3M01 3M73
3M96
3M08-1
3M17-1
3MCW-4 3MCW-6
3MCW-73MCW-5
3MCW-1
3MCW-2
3MCW-8
3MCW-11
3MCW-10
3MCW-9
3MCW-12
3MCW-13
3MCW-14
3MCW-15
3MCW-16
3MCW-17
3MCW-3
377-1
DN
UP
DN
UP.
DN.
DN
DN
R.D.R.D.
A H U #41
A H U #42
A H U #44
A H U #45
A H U #43
A H U #51
N
N N
N
N
W
W
W
W
DD
E
D
D
D
E
E
E
E
E
E
E
E
E EE
E
E
E
E
E E
E
E
E
E
E
E
E
E
E
E E E
E
E
E
EEE
E
E
EE E
EE E
E E
DD
DD
D
D
DD
D
D
D
D
D
D
D
D
D
D
D
D
DDDD
D
D
DD DD DD
E
E
E
E
N N
LP 12A -23
127'
R E LA Y 123/ 11
LP 12A -25
127'
R E LA Y 123/ 12
M A
TC
H
LI
N
E
- A
R E
A
M A
TC
H
LI
N
E
- A
R E
A
M A
TC
H
LI
N
E
- A
R E
A
M A
TC
H
LI
N
E
- A
R E
A
M A
TC
H
LI
N
E
- A
R E
A
M A
TC
H
LI
N
E
- A
R E
A
M A
TC
H
LI
N
E
- A
R E
A
M A
TC
H
LI
N
E
- A
R E
A
M A
TC
H
LI
N
E
- A
R E
A
M A
TC
H
LI
N
E
- A
R E
A
M A
TC
H
LI
N
E
- A
R E
A
M A
TC
H
LI
N
E
- A
R E
A
M A
TC
H
LI
N
E
- A
R E
A
M A
TC
H
LI
N
E
- A
R E
A
M A
TC
H
LI
N
E
- A
R E
A
M A
TC
H
LI
N
E
- A
R E
A
M A
TC
H
LI
N
E
- A
R E
A
M A
TC
H
LI
N
E
- A
R E
A
M A
TC
H
LI
N
E
- A
R E
A
M A
TC
H
LI
N
E
- A
R E
A
M A
TC
H
LI
N
E
- A
R E
A
M A
TC
H
LI
N
E
- A
R E
A
M A
TC
H
LI
N
E
- A
R E
A
M A
TC
H
LI
N
E
- A
R E
A
M A
TC
H
LI
N
E
A R
E A
M A
TC
H
LI
N
E
A R
E A
M A
TC
H
LI
N
E
A R
E A
M A
TC
H
LI
N
E
A R
E A
R P B -3R P B -3
R P B -3 R P B -3 R P B -3
R P B -3
R P B -3
R P B -3
R P B -4
R P B -3
R P B -3
R P B -3
R P B -3
R P B -3
R P B -3
R R R R R
R
R R R R R R R R R
R
R
R
R
R
R
R
R
R
R
R R R RR R
R
R
R
R
R
R
R R R R R R R R
R
R
R
R
R
RE H 9C -2
R
R R
R E H 5B -7
R
E H 5B -7
R E H 5B -7
R E H 5B -7
R E H 5B -7
R
E H 5B -7
R
E H 5B -7
R
E H 5B -7
R
E H 5B -7
R
E H 5B -7
R
E H 5B -7
R
E H 5B -7
R
E H 5B -7
R
E H 5B -7
R
E H 5B -7
R
E H 5B -7
R
E H 5B -7
R
E H 5B -7
R
E H 5B -7
R
E H 5B -7
R
E H 5B -7
TY P E FR
E H 5B -9
A H U -40
E H 7-1
E H 7-1E H 7-11
E H 7-11
E H 7-11
E H 7-11
E H 7-11
LP 7-11
LP 7-11
LP 7-11
LP 7-11
LP 7-11
LP 7-11
LP 7-11
LP 7-11
LP 7-11
LP 7-11LP 7-11
H M1-17
H M1-17
H M1-17
E H 5B -9
H M1-17
H M1-17
H M1-17
H M1-17
H M1-17
H M1-17
E H 5B -9
H M1-17
H M1-17
H M1-17H M1-17
H M1-17
H M1-17
H M1-17
E H 5B -9
H M1-17
LP 11-54
E H 11-9
LP 11-54
LP 11-54
LP 11-54
E H 11-9
LP 12A -3
LP 12A -3
LP 12A -3
LP 12A -3LP 12A -3
E H 12A -2
E H 12A -2
E H 12A -2
R P B -3R P B -3 R P B -3R P B -3 R P B -3R P B -3
NN
E H 2-3E H 2-3
E H 5B -9
E H 5B -9
H M1-17
LP 12A -3
E H 5A -3 E H 5A -3
R
R
E H 9C -2
E H 9C -2 E H 9C -2
E H 9C -2
E H 9C -2E H 9C -2E H 9C -2E H 9C -2E H 9C -2E H 9C -2
E H 9C -4
E H 9C -4
E H 9C -4
E H 9C -4
E H 9C -4
E H 9C -4
E H 9C -4
E H 9C -4E H 9C -4E H 9C -4E H 9C -4E H 9C -6E H 9C -6E H 9C -6E H 9C -6
E H 9C -6
E H 9C -6
E H 9C -6
E H 9C -8E H 9C -8E H 9C -8
E H 9C -8
E H 9C -8E H 9C -8E H 9C -8
E H 9C -10
E H 9C -10
E H 9C -10
E H 9C -10
E H 9C -10
E H 9C -10
E H 9C -9E H 9C -9E H 9C -9E H 9C -9E H 9C -9
E H 9C -9
E H 9C -11 E H 9C -9E H 9C -11
E H 9C -11
E H 9C -11
E H 9C -11
E H 9C -11
E H 9C -6
R P B -4
R P B -4
R P B -4
R P B -4
R P B -4
R P B -4 R P B -4
R P B -4 R P B -4
R P B -4
R P B -4
R P B -4
R P B -4
R P B -4 R P B -4
R P B -4 R P B -4
R
E H 5B -7
S
S
S
S
S
S
S
S
S
S
S S
S
S
S
S
S S S
JJ
DN
E.F.H.
E.F.H.
UP
E.F.H.
E.F.H.
UP
U P
Dock 4Dock 5 Hall D2Hall D1
Lobby
Non Rigging Area Non Rigging Area Non Rigging Area Non Rigging Area Non Rigging Area
Non Rigging Area Non Rigging Area Non Rigging Area Non Rigging Area Non Rigging Area
ATRIUM OPEN TO BELOW ATRIUM OPEN TO BELOW
OPEN TO BELOW
CHAPIN
THEATER
W420
B A
L C
O N
Y
W
A
B
C
D
O P
E N
T O
B E
L O
W
ROOF
ROOF ROOF
ROOF
BOTTOM
C ON T R OL LE R
10" 3'- 6" 4'- 0"
8'- 3"
6'-
1"
7'- 0"
1'-
1" 3'-
6" 2'-
7"
5'- 7"
11'- 0"
8'- 2"
9'-
2"
5'- 6"
7'- 6"
8'- 6"
11'- 9"
7'-5 1/ 4"
9'-
4"
5'-
3/
6"
3CW-173CW-18
NEW STAIR
ELEVATOR
NEW
ELEVATOR
NO. 7
NEW
ELEVATOR
NO. 6
MECHANICAL ROOM
MULTI-PURPOSE ROOM BELOW
LADDER RM.
MECHANICAL ROOM
MECHANICAL ROOM
MEETING ROOM BELOW
ELEV. LOBBY
STAIR
NO. 7
AHU #64 AHU #35
AHU #34AHU #29
AHU #37
AHU #33
AHU #67
AHU #65
AHU #31
AHU #27
AHU #30
SHOW POWER
AHU #69
AHU #68
AHU #26
AHU #28
EXHIBIT HALL BELOW
EXHIBIT HALL BELOW
EXHIBIT HALL BELOW
EXHIBIT HALL BELOW
AHU #66
ELEVATOR
NO 2
STAIR
NO. 8
STAIR NO. 9
STAIR NO. 11
3V
3M04
3M03
3M05
3M06
3M01 3M73
3MCW-4 3MCW-6
3MCW-73MCW-5
3MCW-1
3MCW-2
3MCW-8
3MCW-11
3MCW-10
3MCW-9
3MCW-12
3MCW-13
3MCW-14
3MCW-15
3MCW-16
3MCW-17
3MCW-3
377-1
3M96
3M08-1
3M17-1
CONTROLLER CONTROLLER CONTROLLER
GALLERY
C W
3CW-10
OPEN TO BELOW OPEN TO BELOW
OPEN TO BELOW
ROOF NIC
ROOF NIC
ROOF NIC
ROOF NIC
OPEN TO BELOW
OPEN TO BELOW
OPEN TO BELOW
OPEN TO BELOW
OPEN TO BELOW
OPEN TO BELOW
OPEN TO BELOW
OPEN TO BELOW
OPEN TO BELOWOPEN TO BELOW
OPEN TO BELOW
3M03
3M04A
3M04B
C W
C W
C W
C W
C W
C W
C W
3CW-33CW-2
C W
M
3M02
3M17-1
M
M C W
C W
3MCW-14
3CW-53CW-4
3MCW-12
M C W
3MCW-11
3CW-16
M
3MCW-8
M C W
M C W
3MCW-3
M C W
3MCW-5
M C W
M C W
3MCW-15
M C W
M C W
M C W
AHU #29
AHU #65
MECHANICAL ROOM
MULTI-PURPOSE ROOM BELOW
EXHIBIT HALL BELOW
LADDER RM.
MECHANICAL ROOM
MECHANICAL ROOM
MECHANICAL ROOM
MEETING ROOM BELOW
ELEVATOR
NO. 5
STAIR NO. 1
CATWALK LANDING
ELEV. LOBBY
STAIR
NO. 7
STAIR
NO. 8
STAIR NO. 9
STAIR NO. 11
AHU #64 AHU #35
AHU #34AHU #29
AHU #37
AHU #33
AHU #67
AHU #65
AHU #31
AHU #27
AHU #30
AHU #53
AHU #69
AHU #68
AHU #26
AHU #28
EXHIBIT HALL BELOW
EXHIBIT HALL BELOW
EXHIBIT HALL BELOW
EXHIBIT HALL BELOW
EXHIBIT HALL BELOW
EXHIBIT HALL BELOW
AHU #66
AHU #32
ELEVATOR
NO 2
ELEVATOR
NO. 3
ELEVATOR
NO. 4
STAIR
NO. 12
3MCW-5
3MCW-11
3M04
3M03
3M02
3M05
3M06
316-1
3M08-2
3M01 3M73
3M96
3M08-1
3M17-1
3MCW-4 3MCW-6
3MCW-73MCW-5
3MCW-1
3MCW-2
3MCW-8
3MCW-11
3MCW-10
3MCW-9
3MCW-12
3MCW-13
3MCW-14
3MCW-15
3MCW-16
3MCW-17
3MCW-3
377-1
DN
UP
DN
UP.
DN.
DN
DN
R.D.R.D.
A H U #41
A H U #42
A H U #44
A H U #45
A H U #43
A H U #51
N
N N
N
N
W
W
W
W
DD
E
D
D
D
E
E
E
E
E
E
E
E
E EE
E
E
E
E
E E
E
E
E
E
E
E
E
E
E
E E E
E
E
E
EE
E
E
E
EE E
EE E
E E
DD
DD
D
D
DD
D
D
D
D
D
D
D
D
D
D
D
D
DDDD
D
D
DD DD DD
E
E
E
E
N N
LP 12A -23
127'
R E LA Y 123/ 11
LP 12A -25
127'
R E LA Y 123/ 12
M A
TC
H
LI
N
E
- A
R E
A
M A
TC
H
LI
N
E
- A
R E
A
M A
TC
H
LI
N
E
- A
R E
A
M A
TC
H
LI
N
E
- A
R E
A
M A
TC
H
LI
N
E
- A
R E
A
M A
TC
H
LI
N
E
- A
R E
A
M A
TC
H
LI
N
E
- A
R E
A
M A
TC
H
LI
N
E
- A
R E
A
M A
TC
H
LI
N
E
- A
R E
A
M A
TC
H
LI
N
E
- A
R E
A
M A
TC
H
LI
N
E
- A
R E
A
M A
TC
H
LI
N
E
- A
R E
A
M A
TC
H
LI
N
E
- A
R E
A
M A
TC
H
LI
N
E
- A
R E
A
M A
TC
H
LI
N
E
- A
R E
A
M A
TC
H
LI
N
E
- A
R E
A
M A
TC
H
LI
N
E
- A
R E
A
M A
TC
H
LI
N
E
- A
R E
A
M A
TC
H
LI
N
E
- A
R E
A
M A
TC
H
LI
N
E
- A
R E
A
M A
TC
H
LI
N
E
- A
R E
A
M A
TC
H
LI
N
E
- A
R E
A
M A
TC
H
LI
N
E
- A
R E
A
M A
TC
H
LI
N
E
- A
R E
A
M A
TC
H
LI
N
E
A R
E A
M A
TC
H
LI
N
E
A R
E A
M A
TC
H
LI
N
E
A R
E A
M A
TC
H
LI
N
E
A R
E A
R P B -3R P B -3
R P B -3 R P B -3 R P B -3
R P B -3
R P B -3
R P B -3
R P B -4
R P B -3
R P B -3
R P B -3
R P B -3
R P B -3
R P B -3
R R R R R
R
R R R R R R R R R
R
R
R
R
R
R
R
R
R
R
R R R RR R
R
R
R
R
R
R
R R R R R R R R
R
R
R
R
R
RE H 9C -2
R
R R
R E H 5B -7
R
E H 5B -7
R E H 5B -7
R E H 5B -7
R E H 5B -7
R
E H 5B -7
R
E H 5B -7
R
E H 5B -7
R
E H 5B -7
R
E H 5B -7
R
E H 5B -7
R
E H 5B -7
R
E H 5B -7
R
E H 5B -7
R
E H 5B -7
R
E H 5B -7
R
E H 5B -7
R
E H 5B -7
R
E H 5B -7
R
E H 5B -7
R
E H 5B -7
TY P E FR
E H 5B -9
A H U -40
E H 7-1
E H 7-1E H 7-11
E H 7-11
E H 7-11
E H 7-11
E H 7-11
LP 7-11
LP 7-11
LP 7-11
LP 7-11
LP 7-11
LP 7-11
LP 7-11
LP 7-11
LP 7-11
LP 7-11LP 7-11
H M1-17
H M1-17
H M1-17
E H 5B -9
H M1-17
H M1-17
H M1-17
H M1-17
H M1-17
H M1-17
E H 5B -9
H M1-17
H M1-17
H M1-17H M1-17
H M1-17
H M1-17
H M1-17
E H 5B -9
H M1-17
LP 11-54
E H 11-9
LP 11-54
LP 11-54
LP 11-54
E H 11-9
LP 12A -3
LP 12A -3
LP 12A -3
LP 12A -3LP 12A -3
E H 12A -2
E H 12A -2
E H 12A -2
R P B -3R P B -3 R P B -3R P B -3 R P B -3R P B -3
NN
E H 2-3E H 2-3
E H 5B -9
E H 5B -9
H M1-17
LP 12A -3
E H 5A -3 E H 5A -3
R
R
E H 9C -2
E H 9C -2 E H 9C -2
E H 9C -2
E H 9C -2E H 9C -2E H 9C -2E H 9C -2E H 9C -2E H 9C -2
E H 9C -4
E H 9C -4
E H 9C -4
E H 9C -4
E H 9C -4
E H 9C -4
E H 9C -4
E H 9C -4E H 9C -4E H 9C -4E H 9C -4E H 9C -6E H 9C -6E H 9C -6E H 9C -6
E H 9C -6
E H 9C -6
E H 9C -6
E H 9C -8E H 9C -8E H 9C -8
E H 9C -8
E H 9C -8E H 9C -8E H 9C -8
E H 9C -10
E H 9C -10
E H 9C -10
E H 9C -10
E H 9C -10
E H 9C -10
E H 9C -9E H 9C -9E H 9C -9E H 9C -9E H 9C -9
E H 9C -9
E H 9C -11 E H 9C -9E H 9C -11
E H 9C -11
E H 9C -11
E H 9C -11
E H 9C -11
E H 9C -6
R P B -4
R P B -4
R P B -4
R P B -4
R P B -4
R P B -4 R P B -4
R P B -4 R P B -4
R P B -4
R P B -4
R P B -4
R P B -4
R P B -4 R P B -4
R P B -4 R P B -4
R
E H 5B -7
S
S
S
S
S
S
S
S
S
S
S S
S
S
S
S
S S S
JJ
A1.1
A1.2
A1.3
A2.1
A2.2
A2.3
A3.1
A3.2
A3.3
A4.1
A4.2
A4.3
B1.1
B1.2
B1.3
B2.1
B2.2
B2.3
B4.1
B4.2
B4.3
B3.1
B3.2
B3.3
D1.1
D1.2
D2.1
D2.2
E1.1
E1.2
E2.1
C1.1
C1.2
F1.1
E2.2
F1.2
HALL A HALL B
HALL C HALL D
HALL E
HALL F
WA1 WA2 WA3 WA4 WB1 WB2 WB3 WB4 WC WD1 WD2
D2.3
D2.4
WE1 WE2
HALL F
PANEL - EH5B
HALL E
PANEL - EH9B
RELAY - RCE-8
HALL D
PANEL - EH2G, H3F
RELAY - LAP 315
HALL D
PANEL - H3G
RELAY - LAP 319
HALL C
PANEL - 5DHE1
RELAY - LAP 040
HALL A
PANEL - 4HE24A4
RELAY - 4HE24R4 (LAP 117)
HALL A
PANEL - 4HE24A1
RELAY - 4HE24R1 (LAP 114)
HALL A
PANEL - 4HE24A3
RELAY - 4HE24R3 (LAP 116)
HALL A
PANEL - 4HE24A2
RELAY - 4HE24R2 (LAP 115)
HALL B
PANEL - 5BHE1, 5BLE1
RELAY - LAP 032
HALL B
PANEL - 5CHE1, 5CLE1
RELAY - LAP 036
HALL D
PANEL - EH2H, H1l
RELAY - LAP 320
HALL D
PANEL - H1J
RELAY - LAP 311
HALL A HALL B
HALL C HALL D HALL E
HALL F
WA1 WA2 WA3 WA4 WB1 WB2 WB3 WB4 WC WD1 WD2 WE1 WE2
Z O
N E
A
Z O
N E
A
Z O
N E
A
Z O
N E
A
Z O
N E
B
Z O
N E
B
Z O
N E
B
Z O
N E
B
Z O
N E
C
Z O
N E
D
Z O
N E
D
Z O
N E
E
Z O
N E
E
Z O
N E
F
Engineering | Planning | Allied Services
Offices Nationwide www.hanson-inc.com
Hanson Professional Services Inc.
CONSULTANTS
EB0007061
AA0003116
IB0001058
SHEET TITLE
REVIEWED BY:
DRAWN BY:
DESIGN BY:
PROJECT NO:
ISSUE:
© Copyright Hanson Professional Services Inc. 2024
54321 6
E
D
C
B
A
54321 6
MARK DATE DESCRIPTION
SEAL
/1
/2
:3 :3
A
M
A u to d e sk
D o c s /2
G
O C
C C
W e s t B ld g C a tw a lk
L ig h ti n g /O
C C
C W
E S
T B
L D
G C
A T
W A
L K
L
IG
H T
IN
G
R
.r v t
2300 Maitland Center Pkwy, Suite Maitland, FL 32751 407-790-7397
OCCC West Bldg Catwalk Lighting
9800 International Dr.
Orlando, FL 32819
OVERALL LIGHTING
PLAN - WEST
BUILDING
CATWALKS
E1.1
07/10/2024
23G0084
XT/BM
MB/ML
XT/AJT
100% CD
CATWALK LIGHTING - OVERALL PLAN
CATWALK LIGHTING - ZONING PLAN
DEMOLITION LEGEND
EXISTING CATWALK LIGHTING FIXTURE TO BE
REMOVED. DISCONNECT AND REMOVE CIRCUIT
CABLING BACK TO OVERCURRENT PROTECTION
DEVICE. REMOVE RELAY WIRING BACK TO RELAY
DEVICE. ABANDON CONDUIT IN-PLACE. REFER TO
DETAIL 3 ON SHEET E5.0 FOR ADDITIONAL
INFORMATION.
EXISTING OVERHEAD CATWALK STRIP LIGHTING
FIXTURE TO BE REMOVED. DISCONNECT AND
REMOVE CIRCUIT CABLING AND CONDUIT BACK TO
OVERCURRENT PROTECTION DEVICE. REMOVE
RELAY WIRING BACK TO RELAY DEVICE.
GENERAL NOTES
1. REFER TO SHEET E0.1 FOR GENERAL ELECTRICAL NOTES
2. REFER TO SPECIFICATIONS
3. DEMOLITION OF EXISTING CATWALK LIGHTING SHALL
TAKE PLACE AFTER NEW CATWALK LIGHTS ARE
INSTALLED AND OPERABLE.
WEST HALL A1
WA1
Engineering | Planning | Allied Services
Offices Nationwide www.hanson-inc.com
Hanson Professional Services Inc.
CONSULTANTS
EB0007061
AA0003116
IB0001058
SHEET TITLE
REVIEWED BY:
DRAWN BY:
DESIGN BY:
PROJECT NO:
ISSUE:
© Copyright Hanson Professional Services Inc. 2024
54321 6
E
D
C
B
A
54321 6
MARK DATE DESCRIPTION
SEAL
/1
/2
:3 :4
A
M
A u to d e sk
D o c s /2
G
O C
C C
W e s t B ld g C a tw a lk
L ig h ti n g /O
C C
C W
E S
T B
L D
G C
A T
W A
L K
L
IG
H T
IN
G
R
.r v t
2300 Maitland Center Pkwy, Suite Maitland, FL 32751 407-790-7397
OCCC West Bldg Catwalk Lighting
9800 International Dr.
Orlando, FL 32819
LIGHTING
DEMOLITION PLAN -
AREA A1.1
ED1.A1.1
07/10/2024
23G0084
XT/BM
MB/ML
XT/AJT
100% CD
SCALE: 1/8" = 1'-0"
CATWALK LIGHTING - DEMOLITION - AREA A1.1
4'0 8' 16'
A1.1 A2.1 A3.1 A4.1 B1.1 B2.1 B3.1 B4.1 C1.1
C1.2
D1.1 D2.1
D2.4
E1.1 E2.1
E1.2 E2.2
F1.1
F1.2
A1.2 A2.2 A3.2 A4.2 B1.2 B2.2 B3.2 B4.2
A1.3 A2.3 A3.3 A4.3 B1.3 B2.3 B3.3 B4.3
D1.2 D2.2
D2.3
HALL A HALL B
HALL C
HALL D
HALL E
HALL F
WA1 WA2 WA3 WA4 WB1 WB2 WB3 WB4 WC WD1 WD2 WE1 WE2
REMOVED. DISCONNECT AND REMOVE CIRCUIT
CABLING BACK TO OVERCURRENT PROTECTION
DEVICE. REMOVE RELAY WIRING BACK TO RELAY
DEVICE. ABANDON CONDUIT IN-PLACE. REFER TO
DETAIL 3 ON SHEET E5.0 FOR ADDITIONAL
INFORMATION.
EXISTING OVERHEAD CATWALK STRIP LIGHTING
FIXTURE TO BE REMOVED. DISCONNECT AND
REMOVE CIRCUIT CABLING AND CONDUIT BACK TO
OVERCURRENT PROTECTION DEVICE. REMOVE
RELAY WIRING BACK TO RELAY DEVICE.
GENERAL NOTES
1. REFER TO SHEET E0.1 FOR GENERAL ELECTRICAL NOTES
2. REFER TO SPECIFICATIONS
3. DEMOLITION OF EXISTING CATWALK LIGHTING SHALL
TAKE PLACE AFTER NEW CATWALK LIGHTS ARE
INSTALLED AND OPERABLE.
WEST HALL A1
WA1
Engineering | Planning | Allied Services
Offices Nationwide www.hanson-inc.com
Hanson Professional Services Inc.
CONSULTANTS
EB0007061
AA0003116
IB0001058
SHEET TITLE
REVIEWED BY:
DRAWN BY:
DESIGN BY:
PROJECT NO:
ISSUE:
© Copyright Hanson Professional Services Inc. 2024
54321 6
E
D
C
B
A
54321 6
MARK DATE DESCRIPTION
SEAL
/1
/2
:3 :4
A
M
A u to d e sk
D o c s /2
G
O C
C C
W e s t B ld g C a tw a lk
L ig h ti n g /O
C C
C W
E S
T B
L D
G C
A T
W A
L K
L
IG
H T
IN
G
R
.r v t
2300 Maitland Center Pkwy, Suite Maitland, FL 32751 407-790-7397
OCCC West Bldg Catwalk Lighting
9800 International Dr.
Orlando, FL 32819
LIGHTING
DEMOLITION PLAN -
AREA A1.2
ED1.A1.2
07/10/2024
23G0084
XT/BM
MB/ML
XT/AJT
100% CD
SCALE: 1/8" = 1'-0"
CATWALK LIGHTING - DEMOLITION - AREA A1.2
4'0 8' 16'
A1.1 A2.1 A3.1 A4.1 B1.1 B2.1 B3.1 B4.1 C1.1
C1.2
D1.1 D2.1
D2.4
E1.1 E2.1
E1.2 E2.2
F1.1
F1.2
A1.2 A2.2 A3.2 A4.2 B1.2 B2.2 B3.2 B4.2
A1.3 A2.3 A3.3 A4.3 B1.3 B2.3 B3.3 B4.3
D1.2 D2.2
D2.3
HALL A HALL B
HALL C
HALL D
HALL E
REMOVED. DISCONNECT AND REMOVE CIRCUIT
CABLING BACK TO OVERCURRENT PROTECTION
DEVICE. REMOVE RELAY WIRING BACK TO RELAY
DEVICE. ABANDON CONDUIT IN-PLACE. REFER TO
DETAIL 3 ON SHEET E5.0 FOR ADDITIONAL
INFORMATION.
EXISTING OVERHEAD CATWALK STRIP LIGHTING
FIXTURE TO BE REMOVED. DISCONNECT AND
REMOVE CIRCUIT CABLING AND CONDUIT BACK TO
OVERCURRENT PROTECTION DEVICE. REMOVE
RELAY WIRING BACK TO RELAY DEVICE.
GENERAL NOTES
1. REFER TO SHEET E0.1 FOR GENERAL ELECTRICAL NOTES
2. REFER TO SPECIFICATIONS
3. DEMOLITION OF EXISTING CATWALK LIGHTING SHALL
TAKE PLACE AFTER NEW CATWALK LIGHTS ARE
INSTALLED AND OPERABLE.
WEST HALL A1
WA1
Engineering | Planning | Allied Services
Offices Nationwide www.hanson-inc.com
Hanson Professional Services Inc.
CONSULTANTS
EB0007061
AA0003116
IB0001058
SHEET TITLE
REVIEWED BY:
DRAWN BY:
DESIGN BY:
PROJECT NO:
ISSUE:
© Copyright Hanson Professional Services Inc. 2024
54321 6
E
D
C
B
A
54321 6
MARK DATE DESCRIPTION
SEAL
/1
/2
:3 :4
A
M
A u to d e sk
D o c s /2
G
O C
C C
W e s t B ld g C a tw a lk
L ig h ti n g /O
C C
C W
E S
T B
L D
G C
A T
W A
L K
L
IG
H T
IN
G
R
.r v t
2300 Maitland Center Pkwy, Suite Maitland, FL 32751 407-790-7397
OCCC West Bldg Catwalk Lighting
9800 International Dr.
Orlando, FL 32819
LIGHTING
DEMOLITION PLAN -
AREA A1.3
ED1.A1.3
07/10/2024
23G0084
XT/BM
MB/ML
XT/AJT
100% CD
SCALE: 1/8" = 1'-0"
CATWALK LIGHTING - DEMOLITION - AREA A1.3
4'0 8' 16'
A1.1 A2.1 A3.1 A4.1 B1.1 B2.1 B3.1 B4.1 C1.1
C1.2
D1.1 D2.1
D2.4
E1.1 E2.1
E1.2 E2.2
F1.1
F1.2
A1.2 A2.2 A3.2 A4.2 B1.2 B2.2 B3.2 B4.2
A1.3 A2.3 A3.3 A4.3 B1.3 B2.3 B3.3 B4.3
D1.2 D2.2
D2.3
HALL A HALL B
HALL C
HALL D
HALL E
REMOVED. DISCONNECT AND REMOVE CIRCUIT
CABLING BACK TO OVERCURRENT PROTECTION
DEVICE. REMOVE RELAY WIRING BACK TO RELAY
DEVICE. ABANDON CONDUIT IN-PLACE. REFER TO
DETAIL 3 ON SHEET E5.0 FOR ADDITIONAL
INFORMATION.
EXISTING OVERHEAD CATWALK STRIP LIGHTING
FIXTURE TO BE REMOVED. DISCONNECT AND
REMOVE CIRCUIT CABLING AND CONDUIT BACK TO
OVERCURRENT PROTECTION DEVICE. REMOVE
RELAY WIRING BACK TO RELAY DEVICE.
GENERAL NOTES
1. REFER TO SHEET E0.1 FOR GENERAL ELECTRICAL NOTES
2. REFER TO SPECIFICATIONS
3. DEMOLITION OF EXISTING CATWALK LIGHTING SHALL
TAKE PLACE AFTER NEW CATWALK LIGHTS ARE
INSTALLED AND OPERABLE.
4HE24A4
4HE24R4 (LAP 117)
WEST HALL A2
WA2
Engineering | Planning | Allied Services
Offices Nationwide www.hanson-inc.com
Hanson Professional Services Inc.
CONSULTANTS
EB0007061
AA0003116
IB0001058
SHEET TITLE
REVIEWED BY:
DRAWN BY:
DESIGN BY:
PROJECT NO:
ISSUE:
© Copyright Hanson Professional Services Inc. 2024
54321 6
E
D
C
B
A
54321 6
MARK DATE DESCRIPTION
SEAL
/1
/2
:3 :4
A
M
A u to d e sk
D o c s /2
G
O C
C C
W e s t B ld g C a tw a lk
L ig h ti n g /O
C C
C W
E S
T B
L D
G C
A T
W A
L K
L
IG
H T
IN
G
R
.r v t
2300 Maitland Center Pkwy, Suite Maitland, FL 32751 407-790-7397
OCCC West Bldg Catwalk Lighting
9800 International Dr.
Orlando, FL 32819
LIGHTING
DEMOLITION PLAN -
AREA A2.1
ED1.A2.1
07/10/2024
23G0084
XT/BM
MB/ML
XT/AJT
100% CD
SCALE: 1/8" = 1'-0"
CATWALK LIGHTING - DEMOLITION - AREA A2.1
4'0 8' 16'
A1.1 A2.1 A3.1 A4.1 B1.1 B2.1 B3.1 B4.1 C1.1
C1.2
D1.1 D2.1
D2.4
E1.1 E2.1
E1.2 E2.2
F1.1
F1.2
A1.2 A2.2 A3.2 A4.2 B1.2 B2.2 B3.2 B4.2
A1.3 A2.3 A3.3 A4.3 B1.3 B2.3 B3.3 B4.3
D1.2 D2.2
D2.3
HALL A HALL B
HALL C
HALL D
HALL E
REMOVED. DISCONNECT AND REMOVE CIRCUIT
CABLING BACK TO OVERCURRENT PROTECTION
DEVICE. REMOVE RELAY WIRING BACK TO RELAY
DEVICE. ABANDON CONDUIT IN-PLACE. REFER TO
DETAIL 3 ON SHEET E5.0 FOR ADDITIONAL
INFORMATION.
EXISTING OVERHEAD CATWALK STRIP LIGHTING
FIXTURE TO BE REMOVED. DISCONNECT AND
REMOVE CIRCUIT CABLING AND CONDUIT BACK TO
OVERCURRENT PROTECTION DEVICE. REMOVE
RELAY WIRING BACK TO RELAY DEVICE.
GENERAL NOTES
1. REFER TO SHEET E0.1 FOR GENERAL ELECTRICAL NOTES
2. REFER TO SPECIFICATIONS
3. DEMOLITION OF EXISTING CATWALK LIGHTING SHALL
TAKE PLACE AFTER NEW CATWALK LIGHTS ARE
INSTALLED AND OPERABLE.
4HE24A3
4HE24R3 (LAP 116)
WEST HALL A2
WA2
Engineering | Planning | Allied Services
Offices Nationwide www.hanson-inc.com
Hanson Professional Services Inc.
CONSULTANTS
EB0007061
AA0003116
IB0001058
SHEET TITLE
REVIEWED BY:
DRAWN BY:
DESIGN BY:
PROJECT NO:
ISSUE:
© Copyright Hanson Professional Services Inc. 2024
54321 6
E
D
C
B
A
54321 6
MARK DATE DESCRIPTION
SEAL
/1
/2
:3 :4
A
M
A u to d e sk
D o c s /2
G
O C
C C
W e s t B ld g C a tw a lk
L ig h ti n g /O
C C
C W
E S
T B
L D
G C
A T
W A
L K
L
IG
H T
IN
G
R
.r v t
2300 Maitland Center Pkwy, Suite Maitland, FL 32751 407-790-7397
OCCC West Bldg Catwalk Lighting
9800 International Dr.
Orlando, FL 32819
LIGHTING
DEMOLITION PLAN -
AREA A2.2
ED1.A2.2
07/10/2024
23G0084
XT/BM
MB/ML
XT/AJT
100% CD
SCALE: 1/8" = 1'-0"
CATWALK LIGHTING - DEMOLITION - AREA A2.2
4'0 8' 16'
A1.1 A2.1 A3.1 A4.1 B1.1 B2.1 B3.1 B4.1 C1.1
C1.2
D1.1 D2.1
D2.4
E1.1 E2.1
E1.2 E2.2
F1.1
F1.2
A1.2 A2.2 A3.2 A4.2 B1.2 B2.2 B3.2 B4.2
A1.3 A2.3 A3.3 A4.3 B1.3 B2.3 B3.3 B4.3
D1.2 D2.2
D2.3
HALL A HALL B
HALL C
HALL D
HALL E
REMOVED. DISCONNECT AND REMOVE CIRCUIT
CABLING BACK TO OVERCURRENT PROTECTION
DEVICE. REMOVE RELAY WIRING BACK TO RELAY
DEVICE. ABANDON CONDUIT IN-PLACE. REFER TO
DETAIL 3 ON SHEET E5.0 FOR ADDITIONAL
INFORMATION.
EXISTING OVERHEAD CATWALK STRIP LIGHTING
FIXTURE TO BE REMOVED. DISCONNECT AND
REMOVE CIRCUIT CABLING AND CONDUIT BACK TO
OVERCURRENT PROTECTION DEVICE. REMOVE
RELAY WIRING BACK TO RELAY DEVICE.
GENERAL NOTES
1. REFER TO SHEET E0.1 FOR GENERAL ELECTRICAL NOTES
2. REFER TO SPECIFICATIONS
3. DEMOLITION OF EXISTING CATWALK LIGHTING SHALL
TAKE PLACE AFTER NEW CATWALK LIGHTS ARE
INSTALLED AND OPERABLE.
WEST HALL A2
WA2
Engineering | Planning | Allied Services
Offices Nationwide www.hanson-inc.com
Hanson Professional Services Inc.
CONSULTANTS
EB0007061
AA0003116
IB0001058
SHEET TITLE
REVIEWED BY:
DRAWN BY:
DESIGN BY:
PROJECT NO:
ISSUE:
© Copyright Hanson Professional Services Inc. 2024
54321 6
E
D
C
B
A
54321 6
MARK DATE DESCRIPTION
SEAL
/1
/2
:3 :4
A
M
A u to d e sk
D o c s /2
G
O C
C C
W e s t B ld g C a tw a lk
L ig h ti n g /O
C C
C W
E S
T B
L D
G C
A T
W A
L K
L
IG
H T
IN
G
R
.r v t
2300 Maitland Center Pkwy, Suite Maitland, FL 32751 407-790-7397
OCCC West Bldg Catwalk Lighting
9800 International Dr.
Orlando, FL 32819
LIGHTING
DEMOLITION PLAN -
AREA A2.3
ED1.A2.3
07/10/2024
23G0084
XT/BM
MB/ML
XT/AJT
100% CD
SCALE: 1/8" = 1'-0"
CATWALK LIGHTING - DEMOLITION - AREA A2.3
4'0 8' 16'
A1.1 A2.1 A3.1 A4.1 B1.1 B2.1 B3.1 B4.1 C1.1
C1.2
D1.1 D2.1
D2.4
E1.1 E2.1
E1.2 E2.2
F1.1
F1.2
A1.2 A2.2 A3.2 A4.2 B1.2 B2.2 B3.2 B4.2
A1.3 A2.3 A3.3 A4.3 B1.3 B2.3 B3.3 B4.3
D1.2 D2.2
D2.3
HALL A HALL B
HALL C
HALL D
HALL E
REMOVED. DISCONNECT AND REMOVE CIRCUIT
CABLING BACK TO OVERCURRENT PROTECTION
DEVICE. REMOVE RELAY WIRING BACK TO RELAY
DEVICE. ABANDON CONDUIT IN-PLACE. REFER TO
DETAIL 3 ON SHEET E5.0 FOR ADDITIONAL
INFORMATION.
EXISTING OVERHEAD CATWALK STRIP LIGHTING
FIXTURE TO BE REMOVED. DISCONNECT AND
REMOVE CIRCUIT CABLING AND CONDUIT BACK TO
OVERCURRENT PROTECTION DEVICE. REMOVE
RELAY WIRING BACK TO RELAY DEVICE.
GENERAL NOTES
1. REFER TO SHEET E0.1 FOR GENERAL ELECTRICAL NOTES
2. REFER TO SPECIFICATIONS
3. DEMOLITION OF EXISTING CATWALK LIGHTING SHALL
TAKE PLACE AFTER NEW CATWALK LIGHTS ARE
INSTALLED AND OPERABLE.
WEST HALL A3
WA3
Engineering | Planning | Allied Services
Offices Nationwide www.hanson-inc.com
Hanson Professional Services Inc.
CONSULTANTS
EB0007061
AA0003116
IB0001058
SHEET TITLE
REVIEWED BY:
DRAWN BY:
DESIGN BY:
PROJECT NO:
ISSUE:
© Copyright Hanson Professional Services Inc. 2024
54321 6
E
D
C
B
A
54321 6
MARK DATE DESCRIPTION
SEAL
/1
/2
:3 :4
A
M
A u to d e sk
D o c s /2
G
O C
C C
W e s t B ld g C a tw a lk
L ig h ti n g /O
C C
C W
E S
T B
L D
G C
A T
W A
L K
L
IG
H T
IN
G
R
.r v t
2300 Maitland Center Pkwy, Suite Maitland, FL 32751 407-790-7397
OCCC West Bldg Catwalk Lighting
9800 International Dr.
Orlando, FL 32819
LIGHTING
DEMOLITION PLAN -
AREA A3.1
ED1.A3.1
07/10/2024
23G0084
XT/BM
MB/ML
XT/AJT
100% CD
SCALE: 1/8" = 1'-0"
CATWALK LIGHTING - DEMOLITION - AREA A3.1
4'0 8' 16'
A1.1 A2.1 A3.1 A4.1 B1.1 B2.1 B3.1 B4.1 C1.1
C1.2
D1.1 D2.1
D2.4
E1.1 E2.1
E1.2 E2.2
F1.1
F1.2
A1.2 A2.2 A3.2 A4.2 B1.2 B2.2 B3.2 B4.2
A1.3 A2.3 A3.3 A4.3 B1.3 B2.3 B3.3 B4.3
D1.2 D2.2
D2.3
HALL A HALL B
HALL C
HALL D
HALL E
REMOVED. DISCONNECT AND REMOVE CIRCUIT
CABLING BACK TO OVERCURRENT PROTECTION
DEVICE. REMOVE RELAY WIRING BACK TO RELAY
DEVICE. ABANDON CONDUIT IN-PLACE. REFER TO
DETAIL 3 ON SHEET E5.0 FOR ADDITIONAL
INFORMATION.
EXISTING OVERHEAD CATWALK STRIP LIGHTING
FIXTURE TO BE REMOVED. DISCONNECT AND
REMOVE CIRCUIT CABLING AND CONDUIT BACK TO
OVERCURRENT PROTECTION DEVICE. REMOVE
RELAY WIRING BACK TO RELAY DEVICE.
GENERAL NOTES
1. REFER TO SHEET E0.1 FOR GENERAL ELECTRICAL NOTES
2. REFER TO SPECIFICATIONS
3. DEMOLITION OF EXISTING CATWALK LIGHTING SHALL
TAKE PLACE AFTER NEW CATWALK LIGHTS ARE
INSTALLED AND OPERABLE.
WEST HALL A3
WA3
Engineering | Planning | Allied Services
Offices Nationwide www.hanson-inc.com
Hanson Professional Services Inc.
CONSULTANTS
EB0007061
AA0003116
IB0001058
SHEET TITLE
REVIEWED BY:
DRAWN BY:
DESIGN BY:
PROJECT NO:
ISSUE:
© Copyright Hanson Professional Services Inc. 2024
54321 6
E
D
C
B
A
54321 6
MARK DATE DESCRIPTION
SEAL
/1
/2
:3 :4
A
M
A u to d e sk
D o c s /2
G
O C
C C
W e s t B ld g C a tw a lk
L ig h ti n g /O
C C
C W
E S
T B
L D
G C
A T
W A
L K
L
IG
H T
IN
G
R
.r v t
2300 Maitland Center Pkwy, Suite Maitland, FL 32751 407-790-7397
OCCC West Bldg Catwalk Lighting
9800 International Dr.
Orlando, FL 32819
LIGHTING
DEMOLITION PLAN -
AREA A3.2
ED1.A3.2
07/10/2024
23G0084
XT/BM
MB/ML
XT/AJT
100% CD
SCALE: 1/8" = 1'-0"
CATWALK LIGHTING - DEMOLITION - AREA A3.2
4'0 8' 16'
A1.1 A2.1 A3.1 A4.1 B1.1 B2.1 B3.1 B4.1 C1.1
C1.2
D1.1 D2.1
D2.4
E1.1 E2.1
E1.2 E2.2
F1.1
F1.2
A1.2 A2.2 A3.2 A4.2 B1.2 B2.2 B3.2 B4.2
A1.3 A2.3 A3.3 A4.3 B1.3 B2.3 B3.3 B4.3
D1.2 D2.2
D2.3
HALL A HALL B
HALL C
HALL D
HALL E
REMOVED. DISCONNECT AND REMOVE CIRCUIT
CABLING BACK TO OVERCURRENT PROTECTION
DEVICE. REMOVE RELAY WIRING BACK TO RELAY
DEVICE. ABANDON CONDUIT IN-PLACE. REFER TO
DETAIL 3 ON SHEET E5.0 FOR ADDITIONAL
INFORMATION.
EXISTING OVERHEAD CATWALK STRIP LIGHTING
FIXTURE TO BE REMOVED. DISCONNECT AND
REMOVE CIRCUIT CABLING AND CONDUIT BACK TO
OVERCURRENT PROTECTION DEVICE. REMOVE
RELAY WIRING BACK TO RELAY DEVICE.
GENERAL NOTES
1. REFER TO SHEET E0.1 FOR GENERAL ELECTRICAL NOTES
2. REFER TO SPECIFICATIONS
3. DEMOLITION OF EXISTING CATWALK LIGHTING SHALL
TAKE PLACE AFTER NEW CATWALK LIGHTS ARE
INSTALLED AND OPERABLE.
WEST HALL A3
WA3
Engineering | Planning | Allied Services
Offices Nationwide www.hanson-inc.com
Hanson Professional Services Inc.
CONSULTANTS
EB0007061
AA0003116
IB0001058
SHEET TITLE
REVIEWED BY:
DRAWN BY:
DESIGN BY:
PROJECT NO:
ISSUE:
© Copyright Hanson Professional Services Inc. 2024
54321 6
E
D
C
B
A
54321 6
MARK DATE DESCRIPTION
SEAL
/1
/2
:3 :4
A
M
A u to d e sk
D o c s /2
G
O C
C C
W e s t B ld g C a tw a lk
L ig h ti n g /O
C C
C W
E S
T B
L D
G C
A T
W A
L K
L
IG
H T
IN
G
R
.r v t
2300 Maitland Center Pkwy, Suite Maitland, FL 32751 407-790-7397
OCCC West Bldg Catwalk Lighting
9800 International Dr.
Orlando, FL 32819
LIGHTING
DEMOLITION PLAN -
AREA A3.3
ED1.A3.3
07/10/2024
23G0084
XT/BM
MB/ML
XT/AJT
100% CD
SCALE: 1/8" = 1'-0"
CATWALK LIGHTING - DEMOLITION - AREA A3.3
4'0 8' 16'
A1.1 A2.1 A3.1 A4.1 B1.1 B2.1 B3.1 B4.1 C1.1
C1.2
D1.1 D2.1
D2.4
E1.1 E2.1
E1.2 E2.2
F1.1
F1.2
A1.2 A2.2 A3.2 A4.2 B1.2 B2.2 B3.2 B4.2
A1.3 A2.3 A3.3 A4.3 B1.3 B2.3 B3.3 B4.3
D1.2 D2.2
D2.3
HALL A HALL B
HALL C
HALL D
HALL E
REMOVED. DISCONNECT AND REMOVE CIRCUIT
CABLING BACK TO OVERCURRENT PROTECTION
DEVICE. REMOVE RELAY WIRING BACK TO RELAY
DEVICE. ABANDON CONDUIT IN-PLACE. REFER TO
DETAIL 3 ON SHEET E5.0 FOR ADDITIONAL
INFORMATION.
EXISTING OVERHEAD CATWALK STRIP LIGHTING
FIXTURE TO BE REMOVED. DISCONNECT AND
REMOVE CIRCUIT CABLING AND CONDUIT BACK TO
OVERCURRENT PROTECTION DEVICE. REMOVE
RELAY WIRING BACK TO RELAY DEVICE.
GENERAL NOTES
1. REFER TO SHEET E0.1 FOR GENERAL ELECTRICAL NOTES
2. REFER TO SPECIFICATIONS
3. DEMOLITION OF EXISTING CATWALK LIGHTING SHALL
TAKE PLACE AFTER NEW CATWALK LIGHTS ARE
INSTALLED AND OPERABLE.
4HE24A1
4HE24R1 (LAP 114)
WEST HALL A4
WA4
Engineering | Planning | Allied Services
Offices Nationwide www.hanson-inc.com
Hanson Professional Services Inc.
CONSULTANTS
EB0007061
AA0003116
IB0001058
SHEET TITLE
REVIEWED BY:
DRAWN BY:
DESIGN BY:
PROJECT NO:
ISSUE:
© Copyright Hanson Professional Services Inc. 2024
54321 6
E
D
C
B
A
54321 6
MARK DATE DESCRIPTION
SEAL
/1
/2
:3 :4
A
M
A u to d e sk
D o c s /2
G
O C
C C
W e s t B ld g C a tw a lk
L ig h ti n g /O
C C
C W
E S
T B
L D
G C
A T
W A
L K
L
IG
H T
IN
G
R
.r v t
2300 Maitland Center Pkwy, Suite Maitland, FL 32751 407-790-7397
OCCC West Bldg Catwalk Lighting
9800 International Dr.
Orlando, FL 32819
LIGHTING
DEMOLITION PLAN -
AREA A4.1
ED1.A4.1
07/10/2024
23G0084
XT/BM
MB/ML
XT/AJT
100% CD
SCALE: 1/8" = 1'-0"
CATWALK LIGHTING - DEMOLITION - AREA A4.1
4'0 8' 16'
A1.1 A2.1 A3.1 A4.1 B1.1 B2.1 B3.1 B4.1 C1.1
C1.2
D1.1 D2.1
D2.4
E1.1 E2.1
E1.2 E2.2
F1.1
F1.2
A1.2 A2.2 A3.2 A4.2 B1.2 B2.2 B3.2 B4.2
A1.3 A2.3 A3.3 A4.3 B1.3 B2.3 B3.3 B4.3
D1.2 D2.2
D2.3
HALL A HALL B
HALL C
HALL D
HALL E
REMOVED. DISCONNECT AND REMOVE CIRCUIT
CABLING BACK TO OVERCURRENT PROTECTION
DEVICE. REMOVE RELAY WIRING BACK TO RELAY
DEVICE. ABANDON CONDUIT IN-PLACE. REFER TO
DETAIL 3 ON SHEET E5.0 FOR ADDITIONAL
INFORMATION.
EXISTING OVERHEAD CATWALK STRIP LIGHTING
FIXTURE TO BE REMOVED. DISCONNECT AND
REMOVE CIRCUIT CABLING AND CONDUIT BACK TO
OVERCURRENT PROTECTION DEVICE. REMOVE
RELAY WIRING BACK TO RELAY DEVICE.
GENERAL NOTES
1. REFER TO SHEET E0.1 FOR GENERAL ELECTRICAL NOTES
2. REFER TO SPECIFICATIONS
3. DEMOLITION OF EXISTING CATWALK LIGHTING SHALL
TAKE PLACE AFTER NEW CATWALK LIGHTS ARE
INSTALLED AND OPERABLE.
4HE24A2
4HE24R2 (LAP 115)
WEST HALL A4
WA4
Engineering | Planning | Allied Services
Offices Nationwide www.hanson-inc.com
Hanson Professional Services Inc.
CONSULTANTS
EB0007061
AA0003116
IB0001058
SHEET TITLE
REVIEWED BY:
DRAWN BY:
DESIGN BY:
PROJECT NO:
ISSUE:
© Copyright Hanson Professional Services Inc. 2024
54321 6
E
D
C
B
A
54321 6
MARK DATE DESCRIPTION
SEAL
/1
/2
:3 :4
A
M
A u to d e sk
D o c s /2
G
O C
C C
W e s t B ld g C a tw a lk
L ig h ti n g /O
C C
C W
E S
T B
L D
G C
A T
W A
L K
L
IG
H T
IN
G
R
.r v t
2300 Maitland Center Pkwy, Suite Maitland, FL 32751 407-790-7397
OCCC West Bldg Catwalk Lighting
9800 International Dr.
Orlando, FL 32819
LIGHTING
DEMOLITION PLAN -
AREA A4.2
ED1.A4.2
07/10/2024
23G0084
XT/BM
MB/ML
XT/AJT
100% CD
SCALE: 1/8" = 1'-0"
CATWALK LIGHTING - DEMOLITION - AREA A4.2
4'0 8' 16'
A1.1 A2.1 A3.1 A4.1 B1.1 B2.1 B3.1 B4.1 C1.1
C1.2
D1.1 D2.1
D2.4
E1.1 E2.1
E1.2 E2.2
F1.1
F1.2
A1.2 A2.2 A3.2 A4.2 B1.2 B2.2 B3.2 B4.2
A1.3 A2.3 A3.3 A4.3 B1.3 B2.3 B3.3 B4.3
D1.2 D2.2
D2.3
HALL A HALL B
HALL C
HALL D
HALL E
REMOVED. DISCONNECT AND REMOVE CIRCUIT
CABLING BACK TO OVERCURRENT PROTECTION
DEVICE. REMOVE RELAY WIRING BACK TO RELAY
DEVICE. ABANDON CONDUIT IN-PLACE. REFER TO
DETAIL 3 ON SHEET E5.0 FOR ADDITIONAL
INFORMATION.
EXISTING OVERHEAD CATWALK STRIP LIGHTING
FIXTURE TO BE REMOVED. DISCONNECT AND
REMOVE CIRCUIT CABLING AND CONDUIT BACK TO
OVERCURRENT PROTECTION DEVICE. REMOVE
RELAY WIRING BACK TO RELAY DEVICE.
GENERAL NOTES
1. REFER TO SHEET E0.1 FOR GENERAL ELECTRICAL NOTES
2. REFER TO SPECIFICATIONS
3. DEMOLITION OF EXISTING CATWALK LIGHTING SHALL
TAKE PLACE AFTER NEW CATWALK LIGHTS ARE
INSTALLED AND OPERABLE.
WEST HALL A4
WA4
Engineering | Planning | Allied Services
Offices Nationwide www.hanson-inc.com
Hanson Professional Services Inc.
CONSULTANTS
EB0007061
AA0003116
IB0001058
SHEET TITLE
REVIEWED BY:
DRAWN BY:
DESIGN BY:
PROJECT NO:
ISSUE:
© Copyright Hanson Professional Services Inc. 2024
54321 6
E
D
C
B
A
54321 6
MARK DATE DESCRIPTION
SEAL
/1
/2
:3 :5
A
M
A u to d e sk
D o c s /2
G
O C
C C
W e s t B ld g C a tw a lk
L ig h ti n g /O
C C
C W
E S
T B
L D
G C
A T
W A
L K
L
IG
H T
IN
G
R
.r v t
2300 Maitland Center Pkwy, Suite Maitland, FL 32751 407-790-7397
OCCC West Bldg Catwalk Lighting
9800 International Dr.
Orlando, FL 32819
LIGHTING
DEMOLITION PLAN -
AREA A4.3
ED1.A4.3
07/10/2024
23G0084
XT/BM
MB/ML
XT/AJT
100% CD
SCALE: 1/8" = 1'-0"
CATWALK LIGHTING - DEMOLITION - AREA A4.3
4'0 8' 16'
A1.1 A2.1 A3.1 A4.1 B1.1 B2.1 B3.1 B4.1 C1.1
C1.2
D1.1 D2.1
D2.4
E1.1 E2.1
E1.2 E2.2
F1.1
F1.2
A1.2 A2.2 A3.2 A4.2 B1.2 B2.2 B3.2 B4.2
A1.3 A2.3 A3.3 A4.3 B1.3 B2.3 B3.3 B4.3
D1.2 D2.2
D2.3
HALL A HALL B
HALL C
HALL D
HALL E
UP UP
EXISTING CATWALK LIGHTING FIXTURE TO BE
REMOVED. DISCONNECT AND REMOVE CIRCUIT
CABLING BACK TO OVERCURRENT PROTECTION
DEVICE. REMOVE RELAY WIRING BACK TO RELAY
DEVICE. ABANDON CONDUIT IN-PLACE. REFER TO
DETAIL 3 ON SHEET E5.0 FOR ADDITIONAL
INFORMATION.
EXISTING OVERHEAD CATWALK STRIP LIGHTING
FIXTURE TO BE REMOVED. DISCONNECT AND
REMOVE CIRCUIT CABLING AND CONDUIT BACK TO
OVERCURRENT PROTECTION DEVICE. REMOVE
RELAY WIRING BACK TO RELAY DEVICE.
GENERAL NOTES
1. REFER TO SHEET E0.1 FOR GENERAL ELECTRICAL NOTES
2. REFER TO SPECIFICATIONS
3. DEMOLITION OF EXISTING CATWALK LIGHTING SHALL
TAKE PLACE AFTER NEW CATWALK LIGHTS ARE
INSTALLED AND OPERABLE.
WEST HALL B1
WB1
Engineering | Planning | Allied Services
Offices Nationwide www.hanson-inc.com
Hanson Professional Services Inc.
CONSULTANTS
EB00070…
This is the start of the file's text. The full file is on GovTribe.