White Horse Wildlife Management Area Storage Building - Design and Construction Documents

This document set consists of architectural, mechanical, plumbing, and electrical drawings and specifications for a storage building project for the West Virginia Division of Natural Resources, Wildlife Resources Section at White Horse Wildlife Management Area. The project includes construction of a storage facility with multiple functional spaces: unheated bays (101), office (103), bunk/storage (104), restroom (105), and storage (106). The scope of work encompasses HVAC systems with propane and electric heating, plumbing with water and sanitary systems, electrical power distribution and lighting, and fire alarm systems. The drawings indicate scale relationships at 3/16"=1'-0" and 1/4"=1'-0", with design completion dated August 4, 2020. The project number is 20024, and professional design services were provided by Chapman Technical Group with offices in St. Albans and Buckhannon, West Virginia, and GRW (a division providing architecture, civil engineering, and related services).

The specifications detail comprehensive installation requirements for all mechanical, plumbing, and electrical systems. HVAC equipment includes a 125 MBH propane unit heater (Reznor UDAS125), electric wall heaters, exhaust and supply fans, package terminal AC units (GE model), and motorized louvers, with all materials and labor responsibility assigned to the mechanical contractor. Plumbing systems specify Schedule 40 PVC piping for sanitary and storm drainage, Type L copper for hot and cold water service, and fixtures including Kohler lavatories and toilets, a Navien instantaneous water heater (150,000 BTU input), and a Bradley combination emergency shower/eyewash station. Electrical work requires 250-amp service with a panelboard, conduit installation per NEC standards, LED lighting fixtures from manufacturers including Lithonia and Cooper, and a fire alarm system with addressable smoke and heat detectors, manual pull stations, and audible/visual notification devices. All work must comply with current editions of applicable codes (International Plumbing Code, NEC, NFPA standards), include one-year warranties on materials and workmanship, and provide as-built drawings and operation manuals upon completion.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

L

L

SF

EF

EWH

HP

HP

STORAGE

BUNK/STORAGE

RESTROOM

OFFICE

UNHEATED

BAYS

HP

SF

GUH

T x x

AIRPORT PLANNING / DEVELOPMENT

ARCHITECTURE / INTERIOR DESIGN

CIVIL ENGINEERING / SITE DEVELOPMENT

ENVIRONMENTAL ENGINEERING

LANDSCAPE ARCHITECTURE

SURVEYING

St. Albans, WV

(304) 727-5501

Buckhannon, WV

(304) 472-8914 a division of

GRW

AutoCAD SHX Text MOUNT TOP OF LOUVER +12'-0" ABOVE FINISHED FLOOR. MOUNT TOP OF FAN +12'-0" ABOVE FINISHED FLOOR. MOUNT TOP OF WALL HEATER +6'-0" ABOVE FINISHED FLOOR. WALL CAP. MOUNT PACKAGE TERMINAL AC UNIT +8" ABOVE FINISHED FLOOR. MOUNT UNIT HEATER +9'-O" ABOVE FINISHED FLOOR. FRESH AIR AND VENT THROUGH WALL NEAR ROOF EVE. PROVIDE CONCENTRIC VENT KIT THROUGH WALL. INSULATE EACH INTERIOR PIPE TO PREVENT CONDENSATION.

AutoCAD SHX Text

%%UPLAN NOTES:

AutoCAD SHX Text A

AutoCAD SHX Text A

AutoCAD SHX Text A

AutoCAD SHX Text B

AutoCAD SHX Text B

AutoCAD SHX Text C

AutoCAD SHX Text C

AutoCAD SHX Text D

AutoCAD SHX Text E

AutoCAD SHX Text D

AutoCAD SHX Text 6"%%C

AutoCAD SHX Text

MODEL NO.

AutoCAD SHX Text

MARK

AutoCAD SHX Text

ELECTRIC HEATER SCHEDULE

AutoCAD SHX Text

MBH

AutoCAD SHX Text

KW

AutoCAD SHX Text

CFM

AutoCAD SHX Text

VOLTS / PHASE

AutoCAD SHX Text

NOTES

AutoCAD SHX Text

MANUFACTURER

AutoCAD SHX Text

WEIGHT

AutoCAD SHX Text

(LBS)

AutoCAD SHX Text

%%UNOTES:

AutoCAD SHX Text

1) WALL HEATER WITH BUILT-IN THERMOSTAT CONTROL; THERMAL OVERLOAD; FAN DELAY SWITCH; POWER DISCONNECT SWITCH; SURFACE MOUNT CABINET.

AutoCAD SHX Text

EWH-1

AutoCAD SHX Text

QMARK

AutoCAD SHX Text

VOLTS / PHASE

AutoCAD SHX Text

EXHAUST AND SUPPLY FAN SCHEDULE

AutoCAD SHX Text

MARK

AutoCAD SHX Text

MANUFACTURER.

AutoCAD SHX Text

MODEL NO.

AutoCAD SHX Text

(LBS)

AutoCAD SHX Text

WEIGHT

AutoCAD SHX Text

CFM

AutoCAD SHX Text T.S.

AutoCAD SHX Text

S.P. (IN)

AutoCAD SHX Text

SONES

AutoCAD SHX Text

HP OR WATTS

AutoCAD SHX Text

NOTES

AutoCAD SHX Text

%%UNOTES:

AutoCAD SHX Text

SF-1

AutoCAD SHX Text

COOK

AutoCAD SHX Text

12XP40D15

AutoCAD SHX Text

AutoCAD SHX Text 1,250

AutoCAD SHX Text 4,605

AutoCAD SHX Text 0.125

AutoCAD SHX Text 1,465

AutoCAD SHX Text 8.7

AutoCAD SHX Text

1/8 HP

AutoCAD SHX Text 120V/1%%C

AutoCAD SHX Text 1,3

AutoCAD SHX Text

RPM

AutoCAD SHX Text

FAN

AutoCAD SHX Text

CWH

AutoCAD SHX Text

AutoCAD SHX Text 1.5

AutoCAD SHX Text 5.1

AutoCAD SHX Text 120V/1%%C

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

FLA

AutoCAD SHX Text 12.6

AutoCAD SHX Text

MCA

AutoCAD SHX Text 15.8

AutoCAD SHX Text

MOCP

AutoCAD SHX Text 20A

AutoCAD SHX Text

ELECTRICAL DATA

AutoCAD SHX Text

FLA

AutoCAD SHX Text 2.8

AutoCAD SHX Text

MCA

AutoCAD SHX Text 3.5

AutoCAD SHX Text

MOCP

AutoCAD SHX Text 20A

AutoCAD SHX Text

LP GAS UNIT HEATER SCHEDULE

AutoCAD SHX Text %%uNOTES

AutoCAD SHX Text

GUH-1

AutoCAD SHX Text

MARK

AutoCAD SHX Text

MANUFACTURER

AutoCAD SHX Text

MODEL NO.

AutoCAD SHX Text

WEIGHT

AutoCAD SHX Text

MBH

AutoCAD SHX Text

INPUT

AutoCAD SHX Text

CFM

AutoCAD SHX Text

NOTES

AutoCAD SHX Text

(LBS)

AutoCAD SHX Text

MBH

AutoCAD SHX Text

OUTPUT

AutoCAD SHX Text

VOLTS/PHASE

AutoCAD SHX Text

REZNOR

AutoCAD SHX Text

UDAS125

AutoCAD SHX Text

AutoCAD SHX Text 125.0

AutoCAD SHX Text 99.6

AutoCAD SHX Text 1/20

AutoCAD SHX Text 1,540

AutoCAD SHX Text

AutoCAD SHX Text 120V/1%%C

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

1) SEPERATED COMBUSTION, LOWSTATIC UNIT HEATER WITH CONCENTRIC VENT KIT AND WALL MOUNT THERMOSTAT.

AutoCAD SHX Text

FLA

AutoCAD SHX Text 5.1

AutoCAD SHX Text

MCA

AutoCAD SHX Text 6.4

AutoCAD SHX Text

MOCP

AutoCAD SHX Text 20A

AutoCAD SHX Text

FAN

AutoCAD SHX Text

HP

AutoCAD SHX Text

EAT

AutoCAD SHX Text

(%%DF)

AutoCAD SHX Text

LAT

AutoCAD SHX Text

(%%DF)

AutoCAD SHX Text

SF-2

AutoCAD SHX Text

COOK

AutoCAD SHX Text

12XP40D15

AutoCAD SHX Text

AutoCAD SHX Text 1,250

AutoCAD SHX Text 4,605

AutoCAD SHX Text 0.125

AutoCAD SHX Text 1,465

AutoCAD SHX Text 8.7

AutoCAD SHX Text

1/8 HP

AutoCAD SHX Text 120V/1%%C

AutoCAD SHX Text 1,3

AutoCAD SHX Text 2.8

AutoCAD SHX Text 3.5

AutoCAD SHX Text 20A

AutoCAD SHX Text

LOUVER SCHEDULE

AutoCAD SHX Text

(DAMPER)

AutoCAD SHX Text

MANUFACTURER

AutoCAD SHX Text

%%UNOTES:

AutoCAD SHX Text

MARK

AutoCAD SHX Text

MODEL NO.

AutoCAD SHX Text SIZE (WxH)

AutoCAD SHX Text

CFM

AutoCAD SHX Text

VOLTS/PHASE

AutoCAD SHX Text

MOD

AutoCAD SHX Text

NOTES

AutoCAD SHX Text

1) EXTRUDED ALUMINUM LOUVER WITH STANDARD FRAME; BIRDSREEN; INSECT SCREEN.

AutoCAD SHX Text

2) COLOR OF LOUVER SHALL BE SELECTED BY ARCH.

AutoCAD SHX Text L-1

AutoCAD SHX Text

RUSKIN

AutoCAD SHX Text

ELF375X

AutoCAD SHX Text 40"x20"

AutoCAD SHX Text 1,250

AutoCAD SHX Text

YES

AutoCAD SHX Text 120V/1%%C

AutoCAD SHX Text 1,2

AutoCAD SHX Text

USE

AutoCAD SHX Text

RELIEF

AutoCAD SHX Text

WITH

AutoCAD SHX Text

INTERLOCK

AutoCAD SHX Text

SF-1

AutoCAD SHX Text

ABBREVIATIONS

AutoCAD SHX Text

ABOVE FINISHED FLOOR

AutoCAD SHX Text

AFF

AutoCAD SHX Text

ELECTRIC WALL HEATER

AutoCAD SHX Text

ELECTRICAL CONTRACTOR

AutoCAD SHX Text

EWH

AutoCAD SHX Text

EXHAUST FAN

AutoCAD SHX Text

EF

AutoCAD SHX Text

EC

AutoCAD SHX Text

GENERAL CONTRACTOR

AutoCAD SHX Text

GC

AutoCAD SHX Text

LOUVER

AutoCAD SHX Text

MOTORIZED DAMPER

AutoCAD SHX Text L

AutoCAD SHX Text

MOD

AutoCAD SHX Text

WITHOUT

AutoCAD SHX Text

WITH

AutoCAD SHX Text

UNLESS NOTED OTHERWISE

AutoCAD SHX Text W/O

AutoCAD SHX Text W/

AutoCAD SHX Text

TYPICAL

AutoCAD SHX Text

UNO

AutoCAD SHX Text

(TYP)

AutoCAD SHX Text

NTS

AutoCAD SHX Text

NOT TO SCALE

AutoCAD SHX Text

MH

AutoCAD SHX Text

MOUNTING HEIGHT

AutoCAD SHX Text

CUBIC FEET PER MINUTE

AutoCAD SHX Text

CFM

AutoCAD SHX Text

ENTER AIR TEMPERATURE

AutoCAD SHX Text

EAT

AutoCAD SHX Text

ENERGY EFFICIENCY RATIO

AutoCAD SHX Text

EER

AutoCAD SHX Text

HORSEPOWER

AutoCAD SHX Text

HP

AutoCAD SHX Text

KILOWATTS

AutoCAD SHX Text

KW

AutoCAD SHX Text

LEAVING AIR TEMPERATURE

AutoCAD SHX Text

LAT

AutoCAD SHX Text

THOUSAND BTU/HR

AutoCAD SHX Text

MBH

AutoCAD SHX Text

REVOLUTIONS PER MINUTE

AutoCAD SHX Text

RPM

AutoCAD SHX Text

TIP SPEED

AutoCAD SHX Text

TS

AutoCAD SHX Text

WEATHER PROOF

AutoCAD SHX Text

WP

AutoCAD SHX Text

ELECTRIC UNIT HEATER

AutoCAD SHX Text

EUH

AutoCAD SHX Text L-2

AutoCAD SHX Text

RUSKIN

AutoCAD SHX Text

ELF375X

AutoCAD SHX Text 40"x20"

AutoCAD SHX Text 1,250

AutoCAD SHX Text

YES

AutoCAD SHX Text 120V/1%%C

AutoCAD SHX Text 1,2

AutoCAD SHX Text

RELIEF

AutoCAD SHX Text

SF-2

AutoCAD SHX Text

EF-1

AutoCAD SHX Text

COOK

AutoCAD SHX Text

GC-146

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 1,630

AutoCAD SHX Text 0.250

AutoCAD SHX Text

AutoCAD SHX Text 1.2

AutoCAD SHX Text 35 W

AutoCAD SHX Text 120V/1%%C

AutoCAD SHX Text 2,3

AutoCAD SHX Text 0.3

AutoCAD SHX Text 0.4

AutoCAD SHX Text 20A

AutoCAD SHX Text

%%UNOTES

AutoCAD SHX Text

MARK

AutoCAD SHX Text

MANUFACTURER

AutoCAD SHX Text

(LB)

AutoCAD SHX Text

WEIGHT

AutoCAD SHX Text

MODEL NO.

AutoCAD SHX Text

PACKAGED TERMINAL AC UNIT SCHEDULE

AutoCAD SHX Text

COOLING CAPACITY

AutoCAD SHX Text

MBH

AutoCAD SHX Text

TOTAL

AutoCAD SHX Text

EER

AutoCAD SHX Text

NOTES

AutoCAD SHX Text

GE

AutoCAD SHX Text

AutoCAD SHX Text

HP-1

AutoCAD SHX Text

AZ58H07D

AutoCAD SHX Text

AutoCAD SHX Text 7.3

AutoCAD SHX Text 13.0

AutoCAD SHX Text

1) ZONELINE UNIT WITH ARCHITECTURAL LOUVER; GALVANIZED STEEL WALL CASE; ROOM CABINET; CHASSIS; LINE CORD CONNECTION KIT WITH MALE PLUG. 2) UNIT MOUNTED 5800 SERIES CONTROLS. 3) COLOR OF LOUVER BY ARCHITECTURAL..

AutoCAD SHX Text

HEATING CAPACITY

AutoCAD SHX Text

MBH

AutoCAD SHX Text

TOTAL

AutoCAD SHX Text

COP

AutoCAD SHX Text 6.4

AutoCAD SHX Text 3.7

AutoCAD SHX Text

AUX. HEATER

AutoCAD SHX Text

MBH

AutoCAD SHX Text

TOTAL

AutoCAD SHX Text

KW

AutoCAD SHX Text 2.6

AutoCAD SHX Text

VOLTS/PHASE

AutoCAD SHX Text 240V/1%%C

AutoCAD SHX Text 8.6

AutoCAD SHX Text

AutoCAD SHX Text

(HIGH)

AutoCAD SHX Text

CFM

AutoCAD SHX Text

FLA

AutoCAD SHX Text 11.6

AutoCAD SHX Text

MCA

AutoCAD SHX Text 14.5

AutoCAD SHX Text

MOCA

AutoCAD SHX Text 20A

AutoCAD SHX Text

GE

AutoCAD SHX Text

AutoCAD SHX Text

HP-2

AutoCAD SHX Text

AZ58H12D

AutoCAD SHX Text

AutoCAD SHX Text 11.8

AutoCAD SHX Text 11.7

AutoCAD SHX Text 10.9

AutoCAD SHX Text 3.4

AutoCAD SHX Text 3.5

AutoCAD SHX Text 240V/1%%C

AutoCAD SHX Text 11.7

AutoCAD SHX Text

AutoCAD SHX Text 15.6

AutoCAD SHX Text 19.5

AutoCAD SHX Text 20A

AutoCAD SHX Text

3) SOLID STATE SPEED CONTROL (MOUNT ON SIDE OF FAN HOUSING).

AutoCAD SHX Text

2) DIRECT DRIVE CEILING FAN WITH BACKDRAFT DAMPER; GRILLE; POWER DISCONNECT; WALL CAP.

AutoCAD SHX Text

1) DIRECT DRIVE PACKAGE PROPELLER WALL SUPPLY FAN WITH OSHA WIRE GUARD; WALL COLLAR; SHUTTER; NON-FUSED POWER DISCONNECT; REMOTE WALL

AutoCAD SHX Text

MOUNT FAN SWITCH; RAIN HOOD.

AutoCAD SHX Text E

AutoCAD SHX Text E

AutoCAD SHX Text

GE

AutoCAD SHX Text

AutoCAD SHX Text

HP-3

AutoCAD SHX Text

AZ58H12D

AutoCAD SHX Text

AutoCAD SHX Text 11.8

AutoCAD SHX Text 11.7

AutoCAD SHX Text 10.9

AutoCAD SHX Text 3.4

AutoCAD SHX Text 3.5

AutoCAD SHX Text 240V/1%%C

AutoCAD SHX Text 11.7

AutoCAD SHX Text

AutoCAD SHX Text 15.6

AutoCAD SHX Text 19.5

AutoCAD SHX Text 20A

AutoCAD SHX Text E

AutoCAD SHX Text B

AutoCAD SHX Text F

AutoCAD SHX Text F

AutoCAD SHX Text G

AutoCAD SHX Text T

AutoCAD SHX Text

GUH-1

AutoCAD SHX Text

SYMBOL LEGEND

AutoCAD SHX Text

SYNBOL

AutoCAD SHX Text

DESCRIPTION

AutoCAD SHX Text

EQUIPMENT SYMBOL - SEE LIST ON DWGS.

AutoCAD SHX Text

THERMOSTAT

AutoCAD SHX Text A

AutoCAD SHX Text

PLAN NOTES

AutoCAD SHX Text

ROUND SHEET METAL DUCT

AutoCAD SHX Text 10"ø

AutoCAD SHX Text

DUCT SIZE - 10" DIAMETER

AutoCAD SHX Text G

AutoCAD SHX Text

HVAC PLAN

AutoCAD SHX Text

SCALE: 3/16"=1'-0"

AutoCAD SHX Text

HVAC PLAN AND SCHEDULES

AutoCAD SHX Text M1

AutoCAD SHX Text

REVISION

AutoCAD SHX Text

SHEET NO.

AutoCAD SHX Text

CHECKED BY:

AutoCAD SHX Text

DESIGNED BY:

AutoCAD SHX Text

DRAWN BY:

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text

JOB NUMBER:

AutoCAD SHX Text

SEAL

AutoCAD SHX Text

BY

AutoCAD SHX Text

DATE

AutoCAD SHX Text

REVISIONS

AutoCAD SHX Text

REVISION

AutoCAD SHX Text

NUMBER

AutoCAD SHX Text

PROJECT INFORMATION

AutoCAD SHX Text Chapman

AutoCAD SHX Text Technical

AutoCAD SHX Text Group

AutoCAD SHX Text www.chaptech.com

AutoCAD SHX Text

KMK

AutoCAD SHX Text

KMK

AutoCAD SHX Text

STAFF

AutoCAD SHX Text

AUGUST 4, 2020

AutoCAD SHX Text 1/4"=1'-0"

AutoCAD SHX Text 20024

AutoCAD SHX Text

AutoCAD SHX Text

DIVISION OF NATURAL RESOURCES

AutoCAD SHX Text

WILDLIFE RESOURCES SECTION

AutoCAD SHX Text

WHITE HORSE WILDLIFE MANAGEMENT AREA

AutoCAD SHX Text

STORAGE BUILDING

FAN FLANGE ON ALL FOUR SIDES MOUNT TO BUILDING

BUILDING FRAMING AROUND ALL FOUR SIDES OF FAN3

BUILDING SIDING2

1 BUILDING FRAMING

NOT TO SCALE

EXHAUST FAN

ADJUSTABLE MOUNTING ANGLE ON ALL FOUR SIDES MOUNT TO BUILDING

7 45 DEGREE WEATHER HOOD

8 BACKDRAFT LOUVER DAMPER

9 STAINLESS STEEL BIRDSCREEN

NOT TO SCALE

DAMPER

3 WALL

1 LOUVER

2 1

4 STAINLESS STEEL BIRDSCREEN

5 SHEET METAL SCREW ON ALL

FOUR SIDES AT 12" CENTER

TO CENTER

AIRPORT PLANNING / DEVELOPMENT

ARCHITECTURE / INTERIOR DESIGN

CIVIL ENGINEERING / SITE DEVELOPMENT

ENVIRONMENTAL ENGINEERING

LANDSCAPE ARCHITECTURE

SURVEYING

St. Albans, WV

(304) 727-5501

Buckhannon, WV

(304) 472-8914 a division of

GRW

AutoCAD SHX Text

%%UDETAIL OF PROPELLER WALL SUPPLY FAN

AutoCAD SHX Text

%%UDETAIL OF LOUVER

AutoCAD SHX Text

SECTION 15500 - HEATING, VENTILATION AND AIR CONDITIONING

AutoCAD SHX Text

GENERAL

AutoCAD SHX Text

1. DESCRIPTION OF THE WORK:

AutoCAD SHX Text

A. THE CONTRACTOR SHALL FURNISH AND INSTALL EQUIPMENT AS INDICATED ON

AutoCAD SHX Text

THE DRAWINGS. ITEMS NOT LISTED OR DETAILED, BUT REQUIRED FOR

AutoCAD SHX Text

INSTALLATION OF A COMPLETE, FULLY FUNCTIONAL HEATING, AIR CONDITIONING

AutoCAD SHX Text

AND VENTILATION SYSTEM SHALL BE FURNISHED AND INSTALLED BY THIS

AutoCAD SHX Text

CONTRACTOR.

AutoCAD SHX Text

B. THE EXTENT OF THE MECHANICAL WORK IS INDICATED ON THE DRAWINGS.

AutoCAD SHX Text

THIS CONTRACTOR SHALL BE RESPONSIBLE FOR INSTALLING FACTORY PROVIDED

AutoCAD SHX Text

ACCESSORIES.

AutoCAD SHX Text

C. THE ENTIRE INSTALLATION SHALL BE IN ACCORDANCE WITH THE DRAWINGS,

AutoCAD SHX Text

SPECIFICATIONS, APPLICABLE REQUIREMENTS OF THE MANUFACTURERS OF THE

AutoCAD SHX Text

EQUIPMENT AND LOCAL CODES REQUIREMENTS, AND IN ACCORDANCE WITH

AutoCAD SHX Text

SMACNA STANDARDS AND THE LATEST EDITIONS OF THE STATE BUILDING CODES,

AutoCAD SHX Text

NFPA-90A, AND NFPA-101.

AutoCAD SHX Text

II. OPERATION MANUALS

AutoCAD SHX Text

A. MAINTENANCE MANUALS AND INSTRUCTIONS: FURNISH THREE (3) SETS OF

AutoCAD SHX Text

COMPLETE OPERATING INSTRUCTIONS COVERING ENTIRE HEATING, VENTILATING AND

AutoCAD SHX Text

AIR CONDITIONING SYSTEM.

AutoCAD SHX Text

III. SYSTEM REQUIREMENTS

AutoCAD SHX Text

A. NOISE AND VIBRATION: EQUIPMENT SHALL OPERATE QUIETLY AND THE DESIGN

AutoCAD SHX Text

OF THE SUPPORTS SHALL BE SUCH THAT THE OPERATION OF THE EQUIPMENT

AutoCAD SHX Text

SHALL CAUSE NO PERCEPTIBLE VIBRATION IN THE FLOORING ADJACENT TO THE

AutoCAD SHX Text

EQUIPMENT, NOR CAUSE, DIRECTLY OR INDIRECTLY, VIBRATION OR OBJECTIONABLE

AutoCAD SHX Text

NOISE IN ANY OTHER PORTION OF THE BUILDING AND/OR IN THE BUILDING

AutoCAD SHX Text

STRUCTURE ITSELF.

AutoCAD SHX Text

B. FOUNDATIONS: FURNISH ALL FOUNDATIONS FOR EQUIPMENT COVERED IN THE

AutoCAD SHX Text

SPECIFICATIONS, AS A PART OF THIS SECTION, UNLESS OTHERWISE INDICATED ON

AutoCAD SHX Text

THE DRAWINGS.

AutoCAD SHX Text

IV. WARRANTY:

AutoCAD SHX Text

A. FURNISH A FIVE (5) YEAR WARRANTY ON ALL COMPRESSORS, A 10 YEAR

AutoCAD SHX Text

WARRANTY ON HEAT EXCHANGERS, AND A ONE (1) YEAR SERVICE AND

AutoCAD SHX Text

GUARANTEE ON ALL CONTROLS, COMPRESSORS, EQUIPMENT AND MATERIALS.

AutoCAD SHX Text

V. MECHANICAL SUBMITTALS

AutoCAD SHX Text

A. SUBMITTALS ARE REQUIRED ON THE FOLLOWING ITEMS:

AutoCAD SHX Text

1. PROPANE HEATERS

AutoCAD SHX Text

2. EXHAUST AND SUPPLY FANS

AutoCAD SHX Text

3. PTAC-UNITS

AutoCAD SHX Text

4. LOUVERS

AutoCAD SHX Text

VI. AS BUILT DRAWINGS

AutoCAD SHX Text

A. FURNISH THE OWNER WITH 3 SETS OF AS-BUILT DRAWINGS UPON

AutoCAD SHX Text

COMPLETION OF THE WORK.

AutoCAD SHX Text

PART 2 - PRODUCTS

AutoCAD SHX Text

I. SHEET METAL WORK. NOTE: THE INSTALLATION OF THE HVAC SYSTEM,

AutoCAD SHX Text

INCLUDING BUT NOT LIMITED TO, RETURN AND SUPPLY DROPS, TRUNK LINES,

AutoCAD SHX Text

BRANCH LINES AND DIFFUSERS SHALL BE COMPLETED IN SUCH A MANNER TO

AutoCAD SHX Text

PRESENT A SYSTEM SUITABLE FOR THE INTENDED PURPOSE. ANY PART OF THE

AutoCAD SHX Text

SYSTEM NOT CONFORMING TO THE ABOVE PURPOSE SHALL BE REMOVED AND

AutoCAD SHX Text

REPLACED BY THIS CONTRACTOR.

AutoCAD SHX Text

A. SUPPLY GALVANIZED SHEET METAL WORK IN ACCORDANCE WITH ASHRAE OR

AutoCAD SHX Text

SMACNA STANDARDS. SIZE OF DUCT INDICATED ON DRAWINGS IS FINISHED INSIDE

AutoCAD SHX Text

DIMENSION.

AutoCAD SHX Text

B. PROVIDE OFFSETS, ELBOWS, AND TRANSITIONS IN DUCTWORK WHERE

AutoCAD SHX Text

NECESSARY, WHETHER OR NOT SHOWN.

AutoCAD SHX Text

C. USE WEIGHTS, BRACING, JOINTS, AND ALL DETAILS IN ACCORDANCE WITH

AutoCAD SHX Text

SMACNA.

AutoCAD SHX Text

D. MAKE INTERIOR OF DUCT SMOOTH AND JOINTS AIR TIGHT. WHERE

AutoCAD SHX Text

NECESSARY TO ENSURE TIGHTNESS, CAULK JOINTS. MAKE THE ENTIRE

AutoCAD SHX Text

INSTALLATION RIGID WITH DUCTWORK FREE FROM RATTLES AND AIR NOISES WHEN

AutoCAD SHX Text

IN OPERATION.

AutoCAD SHX Text

E. MAKE ELBOWS WITH INSIDE RADIUS EQUAL TO THE WIDTH OF THE DUCT

AutoCAD SHX Text

EXCEPT WHERE OTHERWISE SPECIFIED OR NECESSITATED BY UNAVOIDABLE SPACE

AutoCAD SHX Text

CONDITIONS. WHERE INSIDE RADIUS IS LESS THAN 3/4 (THREE FOURTHS) THE

AutoCAD SHX Text

DUCT WIDTH, MULTIPLE TURNING VANES SHALL BE PROVIDED. PROVIDE SQUARE

AutoCAD SHX Text

ELBOWS WITH TUTTLE AND BAILEY "DUCTURNS" OR BARBER COLEMAN "AIRTURNS".

AutoCAD SHX Text

F. INCLUDE ANGLE OF DIVERGENCE FOR ENLARGEMENT NOT TO EXCEED 15

AutoCAD SHX Text

DEGREES WHERE SPACE CONDITIONS PERMIT. INCLUDED ANGLE OF CONVERGENCE

AutoCAD SHX Text

FOR CONTRACTING NOT TO EXCEED 30 DEGREES.

AutoCAD SHX Text

G. PROVIDE FLEXIBLE DUCT CONNECTIONS AT CONNECTION POINTS TO AC UNITS

AutoCAD SHX Text

FOR BOTH SUPPLY AND RETURN DUCTS, AND AT OTHER LOCATIONS INDICATED ON

AutoCAD SHX Text

THE DRAWINGS. FLEXIBLE CONNECTIONS ARE TO BE MADE WITH WOVEN CANVAS

AutoCAD SHX Text

COLLARS NOT LESS THAN TWO INCHES (2") LONG. SECURE COLLARS TO THE

AutoCAD SHX Text

DUCT AND FAN CONNECTIONS BY GALVANIZED CHANNELS. PROVIDE A BRAIDED

AutoCAD SHX Text

COPPER BRIDGE STRAP ACROSS FLEXIBLE CONNECTIONS. PROVIDE FLEXIBLE

AutoCAD SHX Text

CONNECTIONS AT CONNECTION TO EACH FAN.

AutoCAD SHX Text

I. INSTALL LOUVERS AS INDICATED.

AutoCAD SHX Text

PART 3 - EXECUTION

AutoCAD SHX Text

I. SUPERVISION OF ELECTRICAL WORK

AutoCAD SHX Text

A. THIS CONTRACTOR SHALL BE RESPONSIBLE FOR SUPERVISION OF ALL WIRING

AutoCAD SHX Text

(INCLUDING CONTROL WIRING) OF EQUIPMENT INCLUDED IN THIS SECTION AND

AutoCAD SHX Text

SHALL FURNISH ALL NECESSARY DIAGRAMS REQUIRED, INCLUDING CONTROL WIRING

AutoCAD SHX Text

DIAGRAMS. THIS CONTRACTOR SHALL MOUNT OR SUPERVISE MOUNTING OF ALL

AutoCAD SHX Text

CONTROL DEVICES.

AutoCAD SHX Text

II. PAINTING

AutoCAD SHX Text

A. EXCEPT AS SPECIFIED HEREIN, ALL PAINTING WILL BE DONE BY OTHERS.

AutoCAD SHX Text

LEAVE WORK FREE FROM RUST, DIRT, GREASE AND PLASTER.

AutoCAD SHX Text

B. EQUIPMENT WITH A FACTORY APPLIED FINISH SHALL HAVE SCRATCHES, CHIPS,

AutoCAD SHX Text

ETC. PRIMED AND TOUCHED UP WITH MATERIALS WHICH WILL PROTECT THE

AutoCAD SHX Text

SURFACE AND MATCH THE ADJACENT AREAS.

AutoCAD SHX Text

C. INTERIOR OF SHEETMETAL DUCT WHICH IS VISIBLE THROUGH REGISTERS OR

AutoCAD SHX Text

GRILLES SHALL BE PAINTED FLAT BLACK BY THIS CONTRACTOR.

AutoCAD SHX Text

III. CLEANING AND ADJUSTMENTS

AutoCAD SHX Text

A. UPON COMPLETION OF WORK, CLEAN, OIL AND GREASE ALL FANS, MOTORS,

AutoCAD SHX Text

OTHER RUNNING EQUIPMENT AND APPARATUS AND MAKE CERTAIN THAT ALL SUCH

AutoCAD SHX Text

APPARATUS AND MECHANISMS ARE IN PROPER WORKING ORDER AND MADE READY

AutoCAD SHX Text

FOR TEST.

AutoCAD SHX Text

IV. IDENTIFICATION

AutoCAD SHX Text

A. FURNISH AND INSTALL NAMEPLATES ON ALL HVAC EQUIPMENT PROVIDED BY

AutoCAD SHX Text

OWNER AND CONTRACTOR. NAMEPLATES SHALL BE MADE FROM WHITE ENGRAVING

AutoCAD SHX Text

STOCK WITH BLACK LETTERS AND BLACK FOUR EDGE BEVEL. WORDING SHALL

AutoCAD SHX Text

DESCRIBE ITEMS USING SAME DESIGNATION AS THE ELECTRICAL PANEL SCHEDULE,

AutoCAD SHX Text

AND NAMEPLATES SHALL BE ATTACHED USING PROPER SIZE AND TYPE

AutoCAD SHX Text

STAINLESS-STEEL BOLTS OR SELF-DRILLING SCREWS.

AutoCAD SHX Text

B. GLUE-ON, TAPE-ON OR TAPE TYPE NAMEPLATES ARE NOT ACCEPTABLE.

AutoCAD SHX Text

END OF SECTION 15500

AutoCAD SHX Text

1. PROVIDE ALL MATERIALS AND EQUIPMENT AND PERFORM ALL LABOR REQUIRED TO INSTALL COMPLETE AND OPERABLE HVAC SYSTEM AS INDICATED ON THE DRAWINGS, AS SPECIFIED AND AS REQUIRED BY CODE. 2. CERTAIN ITEMS SUCH AS RISES AND DROPS IN DUCTWORK, ARE INDICATED FOR CLARITY IN CERTAIN AREAS. THIS DOES NOT RELIEVE THE CONTRACTOR OF PROVIDED THESE ITEMS NOT SHOWN IN OTHER AREAS AS REQUIRED FOR A COMPLETE INSTALLATION. 3. UNLESS NOTED OTHERWISE, LOCATE ALL ROOM THERMOSTATS AND HUMIDISTAT 5'-0" ABOVE FINISH FLOOR. 4. ALL DUCTWORK SHALL CLEAR DOORS AND WINDOWS. 5. ALL DUCTWORK DIMENSIONS, AS SHOWN ON DRAWINGS, ARE INTERNAL CLEAR DIMENSIONS. DUCT SIZE SHALL BE INCREASED IN SIZE TO COMPENSATE FOR INTERNAL LININGS. 6. LOCATE ALL MECHANICAL EQUIPMENT FOR UNOBSTRUCTED ACCESS TO UNIT ACCESS PANELS, AND CONTROLS. 7. ALL DUCTS SHALL BE GROUNDED ACROSS FLEXIBLE CONNECTIONS WITH FLEXIBLE COPPER GROUNDING STRAPS. 8. CONTROL RELAYS SHALL BE FURNISHED AND WIRED BY THE ELECTRICAL CONTRACTOR. MECHANICAL CONTRACTOR SHALL BE RESPONSIBLE FOR MOUNTING THE RELAY IN THE EQUIPMENT. 9. COORDINATE INSTALLATION OF ALL HVAC EQUIPMENT, DUCTWORK, SUPPORTS, ETC. WITH STRUCTURAL DRAWINGS.

AutoCAD SHX Text

%%UGENERAL MECHANICAL NOTES:

AutoCAD SHX Text

5. GAS UNIT HEATERS

AutoCAD SHX Text

HVAC DETAILS AND SPECIFICATIONS

AutoCAD SHX Text M2

AutoCAD SHX Text

REVISION

AutoCAD SHX Text

SHEET NO.

AutoCAD SHX Text

CHECKED BY:

AutoCAD SHX Text

DESIGNED BY:

AutoCAD SHX Text

DRAWN BY:

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text

JOB NUMBER:

AutoCAD SHX Text

SEAL

AutoCAD SHX Text

BY

AutoCAD SHX Text

DATE

AutoCAD SHX Text

REVISIONS

AutoCAD SHX Text

REVISION

AutoCAD SHX Text

NUMBER

AutoCAD SHX Text

PROJECT INFORMATION

AutoCAD SHX Text Chapman

AutoCAD SHX Text Technical

AutoCAD SHX Text Group

AutoCAD SHX Text www.chaptech.com

AutoCAD SHX Text

KMK

AutoCAD SHX Text

KMK

AutoCAD SHX Text

STAFF

AutoCAD SHX Text

AUGUST 4, 2020

AutoCAD SHX Text 1/4"=1'-0"

AutoCAD SHX Text 20024

AutoCAD SHX Text

AutoCAD SHX Text

DIVISION OF NATURAL RESOURCES

AutoCAD SHX Text

WILDLIFE RESOURCES SECTION

AutoCAD SHX Text

WHITE HORSE WILDLIFE MANAGEMENT AREA

S A

N

SAN

STORAGE

BUNK/STORAGE

RESTROOM

OFFICE

UNHEATED

BAY

S A

N

AIRPORT PLANNING / DEVELOPMENT

ARCHITECTURE / INTERIOR DESIGN

CIVIL ENGINEERING / SITE DEVELOPMENT

ENVIRONMENTAL ENGINEERING

LANDSCAPE ARCHITECTURE

SURVEYING

St. Albans, WV

(304) 727-5501

Buckhannon, WV

(304) 472-8914 a division of

GRW

AutoCAD SHX Text

GRADE OR PAVING

AutoCAD SHX Text

CAST IRON CLEANOUT

AutoCAD SHX Text

WITH COVER FOR DUTY

AutoCAD SHX Text

REQ'D

AutoCAD SHX Text

(USE REDUCING TYPE WHERE

AutoCAD SHX Text

SEWER MATERIAL AND

AutoCAD SHX Text

SIZE AS SPECIFIED.

AutoCAD SHX Text

SURFACE CLEANOUT

AutoCAD SHX Text

NTS

AutoCAD SHX Text

PVC EXTENSION

AutoCAD SHX Text

SAME SIZE AS SEWER

AutoCAD SHX Text

UP TO 6"

AutoCAD SHX Text

PVC LONG SWEEP 1/4

AutoCAD SHX Text

BEND OR CAST IRON

AutoCAD SHX Text

COMB. "Y" & 1/8 BEND

AutoCAD SHX Text

REQ'D).

AutoCAD SHX Text

6" THICK 24" SQUARE

AutoCAD SHX Text

CONCRETE PAD SLOPE

AutoCAD SHX Text

AWAY FROM COVER

AutoCAD SHX Text

EXTEND CLEANOUT ABOVE GRADE

AutoCAD SHX Text

AS REQ'D TO DIVERT SURFACE

AutoCAD SHX Text

WATER AWAY FROM CLEANOUT

AutoCAD SHX Text

%%UDOWNSPOUT DETAIL

AutoCAD SHX Text

NTS

AutoCAD SHX Text

OR PAVING

AutoCAD SHX Text

FINISH GRADE

AutoCAD SHX Text

COVER

AutoCAD SHX Text

18" MIN.

AutoCAD SHX Text

FOUNDATION

AutoCAD SHX Text

PVC EIGHTH BEND

AutoCAD SHX Text

FOR WEIGHT & TYPE OF JOINT

AutoCAD SHX Text

PVC SOIL PIPE SEE SPECIFICATIONS

AutoCAD SHX Text

PVC EIGHTH BEND

AutoCAD SHX Text

DOWN SPOUT

AutoCAD SHX Text

CUT CAP TO RECEIVE

AutoCAD SHX Text

EXTERIOR WALL

AutoCAD SHX Text

DOWN SPOUT

AutoCAD SHX Text

PROVIDE SCH. 40 PVC CAP

AutoCAD SHX Text

%%UDS

AutoCAD SHX Text E

AutoCAD SHX Text 4"

AutoCAD SHX Text SEE CIVIL DRAWINGS FOR CONTINUATION. 4" SANITARY UP WITH TEST TEE AND CLEANOUT AT BASE. CONTINUE 4" VENT UP WITH 4" VENT THRU ROOF. 4" TRAPPED HUB DRAIN TO WITH 4"x6" INCREASER TO SERVE BACKFLOW PREVENTER. 2" VENT UP. SEE DOWNSPOUT DETAIL AND CIVIL DRAWINGS FOR CONTINUATION.

AutoCAD SHX Text A

AutoCAD SHX Text B

AutoCAD SHX Text C

AutoCAD SHX Text D

AutoCAD SHX Text E

AutoCAD SHX Text

PLAN NOTES:

AutoCAD SHX Text

%%UDS

AutoCAD SHX Text E

AutoCAD SHX Text 4"

AutoCAD SHX Text

%%UDS

AutoCAD SHX Text E

AutoCAD SHX Text 4"

AutoCAD SHX Text

%%UFCO

AutoCAD SHX Text

%%USCO

AutoCAD SHX Text A

AutoCAD SHX Text 4"

AutoCAD SHX Text 4"

AutoCAD SHX Text 2"

AutoCAD SHX Text

%%U2"FD-A

AutoCAD SHX Text

%%U2"FD-A

AutoCAD SHX Text B

AutoCAD SHX Text

NOTE: SEE SHEET P2 FOR FIXTURE DESIGNATIONS

AutoCAD SHX Text 1 1/2"

AutoCAD SHX Text

%%U4"VTR

AutoCAD SHX Text

20" INV. BFF

AutoCAD SHX Text

23" INV. BFF

AutoCAD SHX Text C

AutoCAD SHX Text 4"

AutoCAD SHX Text D

AutoCAD SHX Text 3"

AutoCAD SHX Text

%%UDS

AutoCAD SHX Text E

AutoCAD SHX Text 4"

AutoCAD SHX Text

%%UDS

AutoCAD SHX Text E

AutoCAD SHX Text 4"

AutoCAD SHX Text

%%UFCO

AutoCAD SHX Text 2"

AutoCAD SHX Text 2"

AutoCAD SHX Text 1 1/2"

AutoCAD SHX Text

%%UDS

AutoCAD SHX Text E

AutoCAD SHX Text 4"

AutoCAD SHX Text D

AutoCAD SHX Text 4"

AutoCAD SHX Text 4"

AutoCAD SHX Text

%%U4"FD-B

AutoCAD SHX Text

DRAINAGE AND VENT PLAN

AutoCAD SHX Text

SCALE: 3/16"=1'-0"

AutoCAD SHX Text

DRAINAGE AND VENT PLAN

AutoCAD SHX Text P1

AutoCAD SHX Text

REVISION

AutoCAD SHX Text

SHEET NO.

AutoCAD SHX Text

CHECKED BY:

AutoCAD SHX Text

DESIGNED BY:

AutoCAD SHX Text

DRAWN BY:

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text

JOB NUMBER:

AutoCAD SHX Text

SEAL

AutoCAD SHX Text

BY

AutoCAD SHX Text

DATE

AutoCAD SHX Text

REVISIONS

AutoCAD SHX Text

REVISION

AutoCAD SHX Text

NUMBER

AutoCAD SHX Text

PROJECT INFORMATION

AutoCAD SHX Text Chapman

AutoCAD SHX Text Technical

AutoCAD SHX Text Group

AutoCAD SHX Text www.chaptech.com

AutoCAD SHX Text

KMK

AutoCAD SHX Text

KMK

AutoCAD SHX Text

STAFF

AutoCAD SHX Text

AUGUST 4, 2020

AutoCAD SHX Text 1/4"=1'-0"

AutoCAD SHX Text 20024

AutoCAD SHX Text

AutoCAD SHX Text

DIVISION OF NATURAL RESOURCES

AutoCAD SHX Text

WILDLIFE RESOURCES SECTION

AutoCAD SHX Text

WHITE HORSE WILDLIFE MANAGEMENT AREA

S

WH

STORAGE

BUNK/STORAGE

RESTROOM

OFFICE

HEATED

BAYS

GUH

AIRPORT PLANNING / DEVELOPMENT

ARCHITECTURE / INTERIOR DESIGN

CIVIL ENGINEERING / SITE DEVELOPMENT

ENVIRONMENTAL ENGINEERING

LANDSCAPE ARCHITECTURE

SURVEYING

St. Albans, WV

(304) 727-5501

Buckhannon, WV

(304) 472-8914 a division of

GRW

AutoCAD SHX Text

PROPANE PIPING

AutoCAD SHX Text P

AutoCAD SHX Text

FLOOR CLEANOUT

AutoCAD SHX Text

WALL HYDRANT

AutoCAD SHX Text

SURFACE CLEANOUT

AutoCAD SHX Text

FIXTURE DESIGNATION

AutoCAD SHX Text

FLOOR DRAIN

AutoCAD SHX Text

PLAN NOTE

AutoCAD SHX Text

WH

AutoCAD SHX Text A

AutoCAD SHX Text

%%UP-1

AutoCAD SHX Text

%%USCO

AutoCAD SHX Text

%%UFD

AutoCAD SHX Text

SHOCK ABSORBER, LETTER

AutoCAD SHX Text

%%UFCO

AutoCAD SHX Text

PLUMBING SYMBOL LEGEND

AutoCAD SHX Text

SANITARY SEWER

AutoCAD SHX Text

STORM PIPING

AutoCAD SHX Text

HOT WATER PIPE (HW)

AutoCAD SHX Text

COLD WATER PIPE (CW)

AutoCAD SHX Text

DESCRIPTION

AutoCAD SHX Text

ST

AutoCAD SHX Text

SAN

AutoCAD SHX Text

VENT PIPING

AutoCAD SHX Text

SYMBOL

AutoCAD SHX Text

PROPANE VALVE IN VERTICAL

AutoCAD SHX Text

PROPANE VALVE

AutoCAD SHX Text

CHECK VALVE

AutoCAD SHX Text

BALL VALVE

AutoCAD SHX Text

VENT THRU ROOF

AutoCAD SHX Text

TURN UP OR FROM BELOW

AutoCAD SHX Text

TURN DOWN

AutoCAD SHX Text

DESCRIPTION

AutoCAD SHX Text

UNION

AutoCAD SHX Text

VTR

AutoCAD SHX Text

SYMBOL

AutoCAD SHX Text A

AutoCAD SHX Text

DESIGNATES SIZE

AutoCAD SHX Text

ABOVE FINISHED FLOOR

AutoCAD SHX Text

AFF

AutoCAD SHX Text

BELOW FINISH FLOOR

AutoCAD SHX Text

BFF

AutoCAD SHX Text

DOWN

AutoCAD SHX Text

DN

AutoCAD SHX Text

GENERAL CONTRACTOR

AutoCAD SHX Text

GC

AutoCAD SHX Text

PLUMBING CONTRACTOR

AutoCAD SHX Text

PC

AutoCAD SHX Text

WITH

AutoCAD SHX Text

VENT THRU ROOF

AutoCAD SHX Text W/

AutoCAD SHX Text

VTR

AutoCAD SHX Text

TYPICAL

AutoCAD SHX Text

(TYP)

AutoCAD SHX Text

NTS

AutoCAD SHX Text

NOT TO SCALE

AutoCAD SHX Text

BRITISH THERMAL UNIT

AutoCAD SHX Text

BTU

AutoCAD SHX Text

GALLON PER MINUTE

AutoCAD SHX Text

GPM

AutoCAD SHX Text

PLAN NOTES:

AutoCAD SHX Text A

AutoCAD SHX Text 1" WATER SERVICE FROM WELL. SEE CIVIL DRAWINGS AND COORDINATE WITH G.C.. WATER ENTRANCE, SEE DETAIL THIS SHEET. WATER HEATING, SEE DETAIL ON SHEET P3. CONTINUOUS 1/2" PIPING BELOW SLAB TO SERVE S-1 SINK. S-1 SINK. SINK. EMERGENCY STATION, SEE DETAIL THIS SHEET. HOSE BIB AT 30" WITH SERVICE BALL VALVE IN VERTICAL FOR SERVICE. COORDINATE WITH ELECTRICIAN. BALL VALVE WITH DRAIN FEATURE. PROPANE SERVICE LINE AND REGULATOR BY PROPANE PROVIDER. CONNECTED LOAD IS 275,000 BTU'S. CONTRACTOR SHALL CONNECT TO REGULATOR. NOTE: PROPANE TANK LOCATION SHALL BE PROPANE TANK LOCATION SHALL BE FIELD COORDINATED DURING CONSTRUCTION. SLEEVE AND SEAL GAS LINE THRU WALL WITH LINK TYPE SEAL. MAKE CONNECTION TO UNIT HEATER WITH VALVE UNION AND DIRT LEG. 2" COMBUSTION AIR AND VENT PIPING FOR WATER HEATER. INSULATE EACH TO PREVENT SWEATING. WATER HEATING CONCENTRIC VENT THRU WALL NEAR EVE OF METAL BUILDING.

AutoCAD SHX Text B

AutoCAD SHX Text C

AutoCAD SHX Text D

AutoCAD SHX Text E

AutoCAD SHX Text F

AutoCAD SHX Text

%%UWH

AutoCAD SHX Text 3/4"

AutoCAD SHX Text

%%UL-1H

AutoCAD SHX Text

%%UWC-1H

AutoCAD SHX Text

%%USH-1H

AutoCAD SHX Text

%%US-1

AutoCAD SHX Text A

AutoCAD SHX Text C

AutoCAD SHX Text

%%UICB

AutoCAD SHX Text

%%UWS-1

AutoCAD SHX Text

%%UWH

AutoCAD SHX Text D

AutoCAD SHX Text

REDUCER TYP.

AutoCAD SHX Text

%%UHB

AutoCAD SHX Text F

AutoCAD SHX Text G

AutoCAD SHX Text

%%UHB

AutoCAD SHX Text F

AutoCAD SHX Text 1/2"

AutoCAD SHX Text 3/4"

AutoCAD SHX Text 3/4"

AutoCAD SHX Text 3/4"

AutoCAD SHX Text 3/4"

AutoCAD SHX Text 3/4"

AutoCAD SHX Text 1"

AutoCAD SHX Text 3/4"

AutoCAD SHX Text G

AutoCAD SHX Text H

AutoCAD SHX Text 3/4"

AutoCAD SHX Text H

AutoCAD SHX Text J

AutoCAD SHX Text K

AutoCAD SHX Text J

AutoCAD SHX Text K

AutoCAD SHX Text

DOWN

AutoCAD SHX Text

%%UWATER WELL ENTRANCE DETAIL

AutoCAD SHX Text

NTS

AutoCAD SHX Text R

AutoCAD SHX Text 1"

AutoCAD SHX Text

AutoCAD SHX Text 1"

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

NOTES:

AutoCAD SHX Text

AutoCAD SHX Text 1" INCOMING WATER SERVICE SLEEVE AND SEAL THRU SLAB. BUILDING SHUT OFF VALVE. PRESSURE TANK AMTROL WX-250D VERTICAL 44 GALLON EXPANSION TANK WITH BASE. 1" PRO-PLUMBER BRASS TEE WITH (2) 1/4" CONNECTIONS FOR PRESSURE SWITCH AND PRESSURE GAUGE AND (2) 3/4" CONNECTIONS FOR DRAIN VALVE AND PRESSURE RELIEF VALVE. PRESSURE SWITCH. PRESSURE GAUGE. DRAIN VALVE. PRESSURE RELIEF VALVE SET AT 100 PSI.

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

PRESSURE TANK SHOWN ABOVE CONNECTION FOR CLARITY

AutoCAD SHX Text

SUPPLY TO BUILDING

AutoCAD SHX Text

%%UEMERGENCY STATION RISER

AutoCAD SHX Text

NTS

AutoCAD SHX Text

FLOOR SUPPORT

AutoCAD SHX Text

WALL SUPPORT TYP.

AutoCAD SHX Text

1 1/4" TEPID

AutoCAD SHX Text

EMERGENCY

AutoCAD SHX Text

%%UEMV-1

AutoCAD SHX Text 1"

AutoCAD SHX Text 3/4"

AutoCAD SHX Text

EMERGENCY

AutoCAD SHX Text

ES-1

AutoCAD SHX Text

MIXING VALVE

AutoCAD SHX Text

WATER SUPPLY

AutoCAD SHX Text

STATION

AutoCAD SHX Text

%%UES-1

AutoCAD SHX Text

%%UTMV-1

AutoCAD SHX Text E

AutoCAD SHX Text 3/4"

AutoCAD SHX Text 1"

AutoCAD SHX Text B

AutoCAD SHX Text

PUMP DISCONNECT

AutoCAD SHX Text

PUMP POWER CIRCUIT

AutoCAD SHX Text

AutoCAD SHX Text

MBH

AutoCAD SHX Text P

AutoCAD SHX Text 3/4"

AutoCAD SHX Text 1"

AutoCAD SHX Text M

AutoCAD SHX Text L

AutoCAD SHX Text L

AutoCAD SHX Text M

AutoCAD SHX Text

PIPING PLAN

AutoCAD SHX Text

SCALE: 3/16"=1'-0"

AutoCAD SHX Text

PIPING PLAN

AutoCAD SHX Text P2

AutoCAD SHX Text

REVISION

AutoCAD SHX Text

SHEET NO.

AutoCAD SHX Text

CHECKED BY:

AutoCAD SHX Text

DESIGNED BY:

AutoCAD SHX Text

DRAWN BY:

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text

JOB NUMBER:

AutoCAD SHX Text

SEAL

AutoCAD SHX Text

BY

AutoCAD SHX Text

DATE

AutoCAD SHX Text

REVISIONS

AutoCAD SHX Text

REVISION

AutoCAD SHX Text

NUMBER

AutoCAD SHX Text

PROJECT INFORMATION

AutoCAD SHX Text Chapman

AutoCAD SHX Text Technical

AutoCAD SHX Text Group

AutoCAD SHX Text www.chaptech.com

AutoCAD SHX Text

KMK

AutoCAD SHX Text

KMK

AutoCAD SHX Text

STAFF

AutoCAD SHX Text

AUGUST 4, 2020

AutoCAD SHX Text 1/4"=1'-0"

AutoCAD SHX Text 20024

AutoCAD SHX Text

AutoCAD SHX Text

DIVISION OF NATURAL RESOURCES

AutoCAD SHX Text

WILDLIFE RESOURCES SECTION

AutoCAD SHX Text

WHITE HORSE WILDLIFE MANAGEMENT AREA

P

WALL

AIRPORT PLANNING / DEVELOPMENT

ARCHITECTURE / INTERIOR DESIGN

CIVIL ENGINEERING / SITE DEVELOPMENT

ENVIRONMENTAL ENGINEERING

LANDSCAPE ARCHITECTURE

SURVEYING

St. Albans, WV

(304) 727-5501

Buckhannon, WV

(304) 472-8914 a division of

GRW

AutoCAD SHX Text

WALL

AutoCAD SHX Text

FLOOR/

AutoCAD SHX Text 1/2"

AutoCAD SHX Text 1/2"

AutoCAD SHX Text 1 1/2"

AutoCAD SHX Text 1 1/2"

AutoCAD SHX Text

WS-1

AutoCAD SHX Text EL MUSTEE MODEL #17F LAUNDRY TUB ONE-PIECE MOLDED CONSTRUCTION USING DURASTONE, A BLEND OF NATURAL CRUSHED STONE AND POLYESTER RESINS. TUB TO INCLUDE BUILT-IN SCRUB BOARD, INTEGRALLY MOLDED DRAIN ASSEMBLY, WALL MOUNTING HARDWARE, HEAVY GAUGE STEEL LEGS WITH BUILT-IN LEVELERS. 19 GALLON CAPACITY TUB, 13” DEEP. SHALL MEET ANSI SPECIFICATION DEEP. SHALL MEET ANSI SPECIFICATION Z 124-2011. COLOR: WHITE. INCLUDE FAUCET BLOCK AND FAUCET WITH VACUUM BREAKER.

AutoCAD SHX Text

REMARKS

AutoCAD SHX Text

MANUFACTURER

AutoCAD SHX Text

MODEL

AutoCAD SHX Text

MARK

AutoCAD SHX Text

SPECIALTY SCHEDULE

AutoCAD SHX Text

DESCRIPTION

AutoCAD SHX Text

%%UFD-A

AutoCAD SHX Text

ZURN

AutoCAD SHX Text

ZN-415-5B

AutoCAD SHX Text

RESTROOM

AutoCAD SHX Text

FLOOR DRAIN

AutoCAD SHX Text S-1

AutoCAD SHX Text 1/2"

AutoCAD SHX Text 1/2"

AutoCAD SHX Text 1 1/2"

AutoCAD SHX Text 1 1/2"

AutoCAD SHX Text

COUNTER

AutoCAD SHX Text

COUNTER SINK; JUST MODEL #DL2233-A-GR, 18 GAUGE

AutoCAD SHX Text

STAINLESS STEEL SINK PUNCHED 8" ON CENTER FOR ZURN

AutoCAD SHX Text

T&S #B-2731 FAUCET, LESS SPRAYER. PROVIDE STRAINER

AutoCAD SHX Text

BASKETS, WHEEL STOPS, SUPPLIES AND TRAP.

AutoCAD SHX Text

DROP IN

AutoCAD SHX Text

FIXTURE SCHEDULE

AutoCAD SHX Text

MARK

AutoCAD SHX Text

DESCRIPTION

AutoCAD SHX Text

HW

AutoCAD SHX Text

CW

AutoCAD SHX Text

SAN

AutoCAD SHX Text

MOUNTING

AutoCAD SHX Text

VENT

AutoCAD SHX Text

HEIGHT

AutoCAD SHX Text 2"

AutoCAD SHX Text

SET

AutoCAD SHX Text

FLOOR

AutoCAD SHX Text 3"

AutoCAD SHX Text

AutoCAD SHX Text 1/2"

AutoCAD SHX Text

WC-1H

AutoCAD SHX Text L-1H

AutoCAD SHX Text

RIM

AutoCAD SHX Text

34" TO

AutoCAD SHX Text 1/2"

AutoCAD SHX Text 1/2"

AutoCAD SHX Text 1 1/2"

AutoCAD SHX Text 1 1/2"

AutoCAD SHX Text CAST IRON BODY WITH BOTTOM OUTLET AND ADJUSTABLE 5" ROUND NICKEL BRONZE STRAINER. PROVIDE "SURE SEAL" TRAP PRIMER IN DRAIN.

AutoCAD SHX Text

SH-1H

AutoCAD SHX Text 1/2"

AutoCAD SHX Text 1/2"

AutoCAD SHX Text 1 1/2"

AutoCAD SHX Text 2"

AutoCAD SHX Text

ADA

AutoCAD SHX Text CLARION MODEL MP3837BF34CD 34" STALL-ONE PIECE THREE WALL FIBERGLASS REINFORCED POLYESTER RESIN SHOWER STALL WITH INTEGRAL NAILING FLANGE OUTSIDE DIM. 38" WIDE, 38" DEEP 78" HIGH. UNIT MEETS REQUIREMENTS OF ANSI Z124.2 FOR PLASTIC SHOWERS. FURNISH UNIT ACCESSORIZED WITH #503218 GRAB BAR, #5018GRAB BAR, #660 SOAP LEDGES, #400 N/L-LH-32"SDL FOLDING SEAT, BRASS DRAIN. SHOWER TRIM; #CH-SSMV-1 MIXING VALVE WITH LIMIT STOP. #ZHGB-24 HAND HELD SHOWER. #IN-36 CURTAIN ROD. UNIT SHALL BE INSTALLED ADA COMPLIANT. FURNISH AND INSTALL CLARION COLLAPSIBLE THRESHOLD WITH 2.5 END CAPS.

AutoCAD SHX Text

GENERAL NOTES:

AutoCAD SHX Text

1. PERFORM ALL WORK IN ACCORDANCE WITH CURRENT EDITION OF INTERNATIONAL PLUMBING CODE AND ALL APPLICABLE LOCAL CODES AND ORDINANCES. 2. CONTRACTOR SHALL VISIT SITE TO VERIFY ALL EXISTING CONDITIONS THAT MAY AFFECT WORK. 3. CONTRACT SHALL INCLUDE ALL MATERIALS, LABOR, TOOLS, ETC., FOR A COMPLETE AND OPERABLE INSTALLATION. ALL MATERIALS SHALL BE NEW, SPECIFICATION GRADE, AND U.L. LISTED PRODUCTS, UNLESS NOTED OTHERWISE. 4. COORDINATE ALL WORK AND SCHEDULES WITH OWNER, ARCHITECT AND OTHER CONTRACTORS. 5. STORE MATERIALS WHERE DIRECTED. PROTECT STORED MATERIALS AND INSTALLED WORK FROM DAMAGE. REPLACE ALL DAMAGED ITEMS WITH NEW. 6. REMOVE DIRT, DEBRIS AND UNUSED MATERIALS FROM SITE REGULARLY AND DISPOSE OF BY PROPER AND LEGAL METHODS. 7. PROVIDE UNIONS AND VALVES AT ALL EQUIPMENT. 8. PROVIDE PROPER SEALS AND FIRE STOPPING AT ALL WALL AND CEILING PENETRATIONS. REFER TO ARCHITECTURAL DRAWINGS FOR LOCATIONS AND RATINGS FOR WALLS AND CEILINGS.

AutoCAD SHX Text

9. PERFORM TESTING AND MAKE FINAL ADJUSTMENTS TO VERIFY PROPER PERFORM TESTING AND MAKE FINAL ADJUSTMENTS TO VERIFY PROPER PERFORMANCE OF ALL SYSTEMS AND EQUIPMENT. 10. MAINTAIN "AS BUILT" RECORDS OF ALL INSTALLED ITEMS AND PROVIDE TO ARCHITECT AT PROJECT COMPLETION. 11. MOUNT ALL HANDICAP ACCESSIBLE DEVICES AND EQUIPMENT PER UNIFORM FEDERAL ACCESSIBILITY STANDARDS (UFAS) 12. COORDINATE ALL SANITARY, VENT, DOMESTIC AND PROPANE PIPING ELEVATIONS WITH OTHER CONTRACTORS PRIOR TO INSTALLING ANY PIPING. 13. PIPING SHALL NOT BE ROUTED ABOVE ELECTRIC PANELS. 14. ALL PIPING IN EXTERIOR WALLS TO BE RUN ON BUILDING SIDE OF ALL PIPING IN EXTERIOR WALLS TO BE RUN ON BUILDING SIDE OF INSULATION. 15. COORDINATE PIPING IN TOILET AREAS WITH RECESSED TOILET ACCESSORIES. COORDINATE PIPING IN TOILET AREAS WITH RECESSED TOILET ACCESSORIES. OFFSET PIPING AS REQUIRED TO ALLOW RECESS OF THESE ITEMS. SEE ENLARGED TOILET PLANS FOR LOCATIONS. 16. VENT PIPING THROUGH METAL ROOFING SHALL BE PAINTED TO MATCH ROOF VENT PIPING THROUGH METAL ROOFING SHALL BE PAINTED TO MATCH ROOF 17. ALL EXTERIOR PROPANE PIPING SHALL BE PRIMED AND PAINTED WITH TWO ALL EXTERIOR PROPANE PIPING SHALL BE PRIMED AND PAINTED WITH TWO COATS OF EPOXY.

AutoCAD SHX Text 1 1/2"

AutoCAD SHX Text 1"

AutoCAD SHX Text 1 1/2"

AutoCAD SHX Text 1 1/2"

AutoCAD SHX Text

%%UES-1

AutoCAD SHX Text

%%UEMV-1

AutoCAD SHX Text

WALL

AutoCAD SHX Text

FLOOR/

AutoCAD SHX Text COMBININATION EMERGENCY SHOWER EYE/FACE WASH: BRADLEY NO. S19-310PTT SHOWER HEAD AND EYE WASH BOWL CONSTRUCTED OF STAINLESS STEEL, CROME-PLATED BRASS 1" IPS STAY-OPEN BALL VALVE, TWIN PERFORATED DISC/FACED WASH HEADS WITH PROTECTIVE POP-OFF SPRAY HEAD COVERS, PIPE AND FITTINGS TO 1 1/4" GALVANIZED STEEL, 1 1/4" IPS WATER SUPPLY FROM BRADLEY S19-2200 THERMOSTATIC MIXING VALVE.

AutoCAD SHX Text

%%UFCO

AutoCAD SHX Text

%%USCO

AutoCAD SHX Text

HYDRANT (CW)

AutoCAD SHX Text

RECESSED WALL

AutoCAD SHX Text

%%UWH

AutoCAD SHX Text Z-1320

AutoCAD SHX Text

ZURN

AutoCAD SHX Text

ZURN

AutoCAD SHX Text

ZN-1400 NL

AutoCAD SHX Text

FLOOR CLEANOUT

AutoCAD SHX Text

ICE MAKER

AutoCAD SHX Text

%%UICB

AutoCAD SHX Text

BIM875

AutoCAD SHX Text

GUY GRAY

AutoCAD SHX Text

CONNECTION BOX

AutoCAD SHX Text RECESSED 16 GAUGE STEEL BOX WITH EPOXY FINISH 1/2"x1/4" COMPRESSION ANGLE VALVE.

AutoCAD SHX Text BRONZE NICKEL PLATED QUARTER TURN NON-FREEZE HYDRANT WITH HOSE CONNECTION, INTEGRAL VACUUM BREAKER, "T" HANDLE KEY, AND STAINLESS STEEL BOX WITH FULL 180° COVER OPENING.

AutoCAD SHX Text ADJUSTABLE FLOOR CLEANOUT CAST IRON BODY WITH GAS & WATER TIGHT ABS TAPERED THREAD PLUG AND ROUND NICKEL BRONZE ADJUSTABLE TOP.

AutoCAD SHX Text

EXPOSED HOSE BIB

AutoCAD SHX Text

%%UHB

AutoCAD SHX Text

PRIER

AutoCAD SHX Text

C-158NP.75

AutoCAD SHX Text EXPOSED, NICKEL-CHROME PLATED FINISH, CAST BRASS BODY, SOLID BRASS STEM, 3/4" HOSE CONNECTION, STANDARD HANDLE, AND PRIER MODEL P-002CP VACUUM BREAKER, ASSE 1011.

AutoCAD SHX Text

%%UFD-B

AutoCAD SHX Text

ZURN

AutoCAD SHX Text

ZN-415-9B

AutoCAD SHX Text

FLOOR DRAIN

AutoCAD SHX Text CAST IRON BODY WITH BOTTOM OUTLET AND ADJUSTABLE 9" ROUND NICKEL BRONZE STRAINER. PROVIDE "SURE SEAL" TRAP PRIMER IN DRAIN.

AutoCAD SHX Text 1"

AutoCAD SHX Text

CONDENSATE

AutoCAD SHX Text WH-1 WATER HEATER: NAVIEN NPE-180A INSTANTANEOUS HEATER; 150,000 BTU WATER HEATER: NAVIEN NPE-180A INSTANTANEOUS HEATER; 150,000 BTU INPUT; 96% EFFICIENCY; CONDENSING; DUAL STAINLESS STEEL HEAT EXCHANGER; CONCENTRIC VENTING; MICROPROCESSOR CONTROL; AIR PRESSURE SENSOR ON COMBUSTION AIR; GAS PRESSURE SENSOR; LEAK DETECTOR; AIR INTAKE FILTER; 53.6 GPM @ 77° TEMPERATURE RISE; 15 YEAR HEAT EXCHANGER WARRANTY; 5YEAR WARRANTY ON PARTS AND COMPONENTS; 1 YEAR LABOR WARRANTY. 199 MBH INPUT; 2" PVC INTAKE AND EXHAUST WITH CONCENTRIC VENTING.

AutoCAD SHX Text

%%UWATER HEATING EQUIPMENT

AutoCAD SHX Text SCHEMATIC ONLY, WATER HEATING SYSTEM SHALL BE INSTALLED PER MANUFACTURERS WRITTEN INSTALLATION MANUAL INCLUDING HORIZONTAL VENTING AND COMBUSTION AIR PIPING.

AutoCAD SHX Text

NOTE:

AutoCAD SHX Text

PRESSURE RELIEF VALVE

AutoCAD SHX Text

BOILER DRAIN VALVE

AutoCAD SHX Text

UNION

AutoCAD SHX Text

BALL VALVE

AutoCAD SHX Text

%%UWATER HEATING SYMBOLS

AutoCAD SHX Text

%%UWATER HEATER SCHEMATIC

AutoCAD SHX Text

NTS

AutoCAD SHX Text

%%UWH-1

AutoCAD SHX Text 3/4"

AutoCAD SHX Text 3/4"

AutoCAD SHX Text

%%UCONCENTRIC VENTING

AutoCAD SHX Text

WATER HEATER.

AutoCAD SHX Text

CONCENTRIC KIT FURNISHED WITH

AutoCAD SHX Text

2" SCH. 40 PVC VENT PIPE AND

AutoCAD SHX Text

2" SCH. 40 PVC AIR INTAKE PIPE

AutoCAD SHX Text

FROM HEATER, SEAL PIPING

AutoCAD SHX Text

THROUGH WALL. TERMINATE WITH

AutoCAD SHX Text

GAS VALVE

AutoCAD SHX Text

TO F.D.

AutoCAD SHX Text KOHLER #K3979 ELONGATED WATER CLOSET FLOOR SET, SIPHON JET, VITREOUS CHINA, REVERSE TRAP, LOW CONSUMPTION, ELONGATED, DIRECT FEED SIPHON JET ACTION, TWO PIECE TOILET, WHITE ELONGATED OLSONITE #95 OPEN FRONT SEAT LESS COVER WITH STAINLESS CHECK HINGE AND CLOSET BOLT/WAX RING KIT.

AutoCAD SHX Text KOHLER #K2005 20"X18" WALL LAVATORY, WHITE WITH PUNCHING ON 4" CENTERS FOR T&S B-1141 FAUCET, GRID STRAINER, TRAP, TAILPIECE, WHEEL STOPS AND JR SMITH #0710 CHAIR TYPE CONCEALED ARM CARRIER. COMBINATION TRAP AND SUPPLY WRAP PROTECTOR KIT.

AutoCAD SHX Text

PIPING

AutoCAD SHX Text

CONCEALED

AutoCAD SHX Text

IN WALL

AutoCAD SHX Text

PLUMBING SCHEDULES DETAILS AND NOTES

AutoCAD SHX Text P3

AutoCAD SHX Text

REVISION

AutoCAD SHX Text

SHEET NO.

AutoCAD SHX Text

CHECKED BY:

AutoCAD SHX Text

DESIGNED BY:

AutoCAD SHX Text

DRAWN BY:

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text

JOB NUMBER:

AutoCAD SHX Text

SEAL

AutoCAD SHX Text

BY

AutoCAD SHX Text

DATE

AutoCAD SHX Text

REVISIONS

AutoCAD SHX Text

REVISION

AutoCAD SHX Text

NUMBER

AutoCAD SHX Text

PROJECT INFORMATION

AutoCAD SHX Text Chapman

AutoCAD SHX Text Technical

AutoCAD SHX Text Group

AutoCAD SHX Text www.chaptech.com

AutoCAD SHX Text

KMK

AutoCAD SHX Text

KMK

AutoCAD SHX Text

STAFF

AutoCAD SHX Text

AUGUST 4, 2020

AutoCAD SHX Text 1/4"=1'-0"

AutoCAD SHX Text 20024

AutoCAD SHX Text

AutoCAD SHX Text

DIVISION OF NATURAL RESOURCES

AutoCAD SHX Text

WILDLIFE RESOURCES SECTION

AutoCAD SHX Text

WHITE HORSE WILDLIFE MANAGEMENT AREA

AIRPORT PLANNING / DEVELOPMENT

ARCHITECTURE / INTERIOR DESIGN

CIVIL ENGINEERING / SITE DEVELOPMENT

ENVIRONMENTAL ENGINEERING

LANDSCAPE ARCHITECTURE

SURVEYING

St. Albans, WV

(304) 727-5501

Buckhannon, WV

(304) 472-8914 a division of

GRW

AutoCAD SHX Text

PART 1 - GENERAL

AutoCAD SHX Text

I. DESCRIPTION OF THE WORK

AutoCAD SHX Text

A. THE EXTENT OF THE PLUMBING WORK IS INDICATED ON THE DRAWINGS.

AutoCAD SHX Text

II. CODES

AutoCAD SHX Text

A. ALL EQUIPMENT AND THE ENTIRE INSTALLATION SHALL BE IN ACCORDANCE

AutoCAD SHX Text

WITH THE APPLICABLE PROVISIONS OF THE CURRENT EDITION OF THE

AutoCAD SHX Text

INTERNATIONAL PLUMBING CODE, O.S.H.A. REQUIREMENTS, LIFE SAFETY CODE

AutoCAD SHX Text

AND ALL APPLICABLE LOCAL AND STATE LAWS AND ORDINANCES.

AutoCAD SHX Text

B. THE CONTRACTOR SHALL PAY ALL INSPECTION FEES AND PURCHASE ALL

AutoCAD SHX Text

PERMITS REQUIRED FOR THIS WORK.

AutoCAD SHX Text

III. LOCATION OF EQUIPMENT

AutoCAD SHX Text

A. THE CONTRACTOR SHALL NOTE THAT THE PLUMBING DRAWINGS ARE INTENDED

AutoCAD SHX Text

TO INDICATE ONLY THE EXTENT DIAGRAMMATICALLY, GENERAL CHARACTER AND

AutoCAD SHX Text

LOCATION OF THE WORK. WORK INTENDED, BUT HAVING MINOR DETAILS

AutoCAD SHX Text

OBVIOUSLY OMITTED, SHALL BE FURNISHED AND INSTALLED COMPLETE BY THIS

AutoCAD SHX Text

CONTRACTOR AT HIS EXPENSE.

AutoCAD SHX Text

IV. ROUGH-IN

AutoCAD SHX Text

A. VERIFY FINAL LOCATIONS FOR ROUGH-INS WITH SHOP DRAWINGS, FIELD

AutoCAD SHX Text

MEASUREMENTS AND WITH THE REQUIREMENTS OF THE ACTUAL EQUIPMENT TO

AutoCAD SHX Text

BE CONNECTED PRIOR TO ROUGH-IN.

AutoCAD SHX Text

B. OBTAIN FROM OWNER AND GENERAL CONTRACTOR COPIES OF "EQUIPMENT

AutoCAD SHX Text

BROCHURE" AND A SET OF SHOP DRAWINGS OF EQUIPMENT BEFORE

AutoCAD SHX Text

ROUGHING IN ANY WATER, WASTE, CONNECTIONS, ETC. CHANGES RESULTING

AutoCAD SHX Text

FROM FAILURE TO OBTAIN THIS INFORMATION WILL NOT RESULT IN ADDITIONAL

AutoCAD SHX Text

COST.

AutoCAD SHX Text

V. WARRANTIES

AutoCAD SHX Text

A. GUARANTEE ALL PLUMBING SYSTEM MATERIALS AND WORKMANSHIP TO BE

AutoCAD SHX Text

FREE FROM DEFECTS FOR A PERIOD OF ONE (1) YEAR FROM THE DATE OF FINAL

AutoCAD SHX Text

ACCEPTANCE AND PROPERLY CORRECT LATENT DEFECTS ARISING WITHIN THIS

AutoCAD SHX Text

PERIOD UPON NOTIFICATION BY THE OWNER'S REPRESENTATIVE WITHOUT

AutoCAD SHX Text

ADDITIONAL COMPENSATION.

AutoCAD SHX Text

VI. CHANGES

AutoCAD SHX Text

A. THE DRAWINGS INDICATE GENERALLY THE LOCATIONS OF PLUMBING FIXTURES,

AutoCAD SHX Text

APPARATUS, PIPING, ETC., BUT IF, BEFORE INSTALLATION, IT IS FOUND NECESSARY

AutoCAD SHX Text

TO CHANGE THE LOCATION OF SAME TO ACCOMMODATE THE CONDITIONS AT THE

AutoCAD SHX Text

BUILDING, SUCH CHANGES SHALL BE MADE WITHOUT ADDITIONAL COST TO THE

AutoCAD SHX Text

OWNER AND AS DIRECTED BY THE OWNER.

AutoCAD SHX Text

VII. PLUMBING SUBMITTALS:

AutoCAD SHX Text

A. SUBMITTALS ARE REQUIRED ON THE FOLLOWING ITEMS AND THEY MAY BE

AutoCAD SHX Text

SELECTED FROM ONE OF THE MANUFACTURERS LISTED OR APPROVED EQUAL:

AutoCAD SHX Text

1. PLUMBING FIXTURES

AutoCAD SHX Text

a. AMERICAN STANDARD

AutoCAD SHX Text

b. KOHLER

AutoCAD SHX Text

2. FLOOR DRAINS & SPECIALTIES

AutoCAD SHX Text

a. ZURN

AutoCAD SHX Text

b. J.R. SMITH

AutoCAD SHX Text

VIII. AS BUILT DRAWINGS

AutoCAD SHX Text

A. FURNISH THE OWNER THREE (3) SETS OF AS-BUILT DRAWINGS UPON

AutoCAD SHX Text

COMPLETION OF THE WORK.

AutoCAD SHX Text

PART 2 - PRODUCTS

AutoCAD SHX Text

I. PIPING

AutoCAD SHX Text

A. INTERIOR SANITARY AND STORM SYSTEMS SHALL BE SCH. 40 PVC PIPE AND

AutoCAD SHX Text

FITTINGS. CAST IRON NO-HUB SHALL BE USED ABOVE SLAB WHERE ABOVE

AutoCAD SHX Text

B. INTERIOR HOT AND COLD WATER PIPE ABOVE CEILING SHALL BE TYPE "L" HARD

AutoCAD SHX Text

DRAWN COPPER WITH WROUGHT COPPER FITTINGS, LEAD FREE SOLDER JOINTS.

AutoCAD SHX Text

C. EXPOSED PIPE IN RESTROOMS SHALL BE CHROME PLATED BRASS WITH

AutoCAD SHX Text

CHROME PLATED WALL PLATES, AMERICAN BRASS CO. OR EQUIVALENT.

AutoCAD SHX Text

II. CLEANOUTS

AutoCAD SHX Text

A. FLOOR CLEANOUTS SHALL HAVE CAST IRON BODY, NICKEL BRONZE SCORIATED

AutoCAD SHX Text

TOP AND RUBBER GASKETED CONNECTION.

AutoCAD SHX Text

III. VALVES

AutoCAD SHX Text

A. INTERIOR: BALL VALVES SHALL BE 125 POUND, SCREWED, ALL BRONZE, TWO

AutoCAD SHX Text

PIECE, FULL PORT DESIGN. NIBCO T-580 OR EQUIVALENT.

AutoCAD SHX Text

IV. STOP VALVES

AutoCAD SHX Text

A. CROME PLATED MACHINED FROM SOILD BRASS, 1/4 TURN BALL TYPE

AutoCAD SHX Text

OPERATION, PTFE SEATS. COMPLIES WITH ASME A112.18.6. EQUAL TO

AutoCAD SHX Text

B. SINKS AND LAVATORIES SHALL HAVE CHROME PLATED COPPER P-TRAPS 17

AutoCAD SHX Text

GA. MIN.

AutoCAD SHX Text

VII. ESCUTCHEON PLATES

AutoCAD SHX Text

A. CHROME PLATED ESCUTCHEON PLATES FOR ALL EXPOSED PIPE PASSING

AutoCAD SHX Text

THROUGH WALLS, FLOORS OR CEILINGS.

AutoCAD SHX Text

VIII. PIPE INSULATION

AutoCAD SHX Text

A. INSULATE HOT AND COLD WATER PIPING WITH 1" THICK FLEXIBLE

AutoCAD SHX Text

ELECTROMETRIC CELLULAR PIPE INSULATION. SELF SEALING JACKET.

AutoCAD SHX Text

PART 3 - EXECUTION

AutoCAD SHX Text

I. INSTALLATION OF PIPING

AutoCAD SHX Text

A. ON VERTICAL SANITARY DRAIN LINES, CONNECT ALL SOIL AND WASTE INLETS

AutoCAD SHX Text

THROUGH SANITARY TEES, WYES, OR WYES AND EIGHT BENDS. SHORT RADIUS

AutoCAD SHX Text

FITTINGS MAY BE USED FOR VENT PIPING. ON HORIZONTAL LINES, CONNECT ALL

AutoCAD SHX Text

WASTE AND SOIL CONNECTIONS THROUGH WYES, OR WYES AND EIGHT BENDS.

AutoCAD SHX Text

DOUBLE BRANCH FITTINGS MAY BE USED ON VERTICAL LINES AND HORIZONTAL

AutoCAD SHX Text

RUNS PROVIDING PROPER GRADES CAN BE MAINTAINED.

AutoCAD SHX Text

B. MAKE SCREW JOINTS BETWEEN THREADED CONNECTIONS AND OTHER PIPES

AutoCAD SHX Text

WATER-TIGHT WITH APPROVED COMPOUND.

AutoCAD SHX Text

C. PITCH HORIZONTAL DRAINS 1/8" PER FOOT MINIMUM, OR AS PER LOCAL

AutoCAD SHX Text

CODE.

AutoCAD SHX Text

D. PROVIDE CLEANOUTS AT EVERY CHANGE IN DIRECTION OF MORE THAN

AutoCAD SHX Text

FORTY-FIVE DEGREES AND EVERY HUNDRED FEET AS REQUIRED BY LOCAL CODES.

AutoCAD SHX Text

E. CUT BRASS AND COPPER PIPE BY MEANS OF A TUBING CUTTER. REMOVE

AutoCAD SHX Text

ALL BURRS AND METAL CHIPS, DIRT, ETC., BEFORE JOINING PIPE. CHROME

AutoCAD SHX Text

PLATED PIPE SHALL SHOW NO WRENCH MARKS AFTER INSTALLATION; NO THREADS

AutoCAD SHX Text

SHALL SHOW.

AutoCAD SHX Text

F. ADEQUATELY SUPPORT ALL PIPING ABOVE FLOORS, INSIDE THE BUILDING

AutoCAD SHX Text

FROM OR ON THE BUILDING STRUCTURE. SUPPORT PIPING SUSPENDED FROM

AutoCAD SHX Text

THE BUILDING STRUCTURE BY MEANS OF THE SPECIFIED PIPE HANGERS AND

AutoCAD SHX Text

RODS. MAKE MAXIMUM SPACING BETWEEN PIPE SUPPORTS AS FOLLOWS:

AutoCAD SHX Text

COPER AND STEEL MAXIMUM SPAN

AutoCAD SHX Text

3/4" & UNDER 5'

AutoCAD SHX Text 1" 7'

AutoCAD SHX Text 1-1/4" 7'

AutoCAD SHX Text 1-1/2" 9'

AutoCAD SHX Text 2" 10'

AutoCAD SHX Text

II. INSTALLATION OF VALVES

AutoCAD SHX Text

A. ISOLATE ALL MAJOR PIPING ASSEMBLIES AS SHOWN ON THE DRAWINGS AND

AutoCAD SHX Text

AS REQUIRED FOR PROPER OPERATION AND MAINTENANCE. ALL VALVES SHALL

AutoCAD SHX Text

BE ACCESSIBLE. PROVIDE VALVE BOXES AND ACCESS PANELS WHERE REQUIRED

AutoCAD SHX Text

FOR ACCESSIBILITY.

AutoCAD SHX Text

III. INSTALLATION OF TRAPS

AutoCAD SHX Text

A. TRAP EACH FIXTURE BY WATER SEALING TRAP PLACED AS NEAR THE FIXTURE

AutoCAD SHX Text

AS POSSIBLE.

AutoCAD SHX Text

B. VENT ALL TRAPS AS PER LOCAL PLUMBING CODE REQUIREMENTS.

AutoCAD SHX Text

IV. INSTALLATION OF PIPE SLEEVES

AutoCAD SHX Text

A. INSTALL PIPE SLEEVES AT ALL LOCATIONS WHERE PIPE PASSES THROUGH

AutoCAD SHX Text

WALLS, FLOORS, OR CEILINGS.

AutoCAD SHX Text

V. INSTALLATION OF AIR CHAMBERS

AutoCAD SHX Text

A. INSTALL A WATER HAMMER ARRESTOR AT EACH FIXTURE, OR GROUP OF

AutoCAD SHX Text

FIXTURES. WATER HAMMER ARRESTERS, SHALL BE ZURN SHOKTROL SIZED AND

AutoCAD SHX Text

INSTALLED PER MANUFACTURER'S RECOMMENDATION.

AutoCAD SHX Text

VI. INSTALLATION OF FIXTURE TRIM AND FITTINGS

AutoCAD SHX Text

A. INSTALL THE FIXTURE TRIM AND FITTINGS SPECIFIED, TAKING CARE TO

AutoCAD SHX Text

PROPERLY ANCHOR EACH FIXTURE.

AutoCAD SHX Text

B. WHEN THE USE OF A WRENCH IS NECESSARY ON CHROMIUM PLATED PIPING

AutoCAD SHX Text

PROTECT THE PIPE FROM MARRING BY USE OF FELT OR CLOTH WRAPPING

AutoCAD SHX Text

BENEATH WRENCH JAWS.

AutoCAD SHX Text

VII. INSTALLATION OF PIPE INSULATION

AutoCAD SHX Text

A. INSULATE ALL DOMESTIC HOT AND COLD WATER PIPING.

AutoCAD SHX Text

VIII. TESTS AND INSPECTIONS

AutoCAD SHX Text

A. MAKE ALL WATER AND PROPANE TESTS OF THE PIPING SYSTEMS IN THE

AutoCAD SHX Text

PRESENCE OF AND TO THE SATISFACTION OF THE OWNER OR HIS DESIGNATED

AutoCAD SHX Text

REPRESENTATIVE, AND LOCAL OFFICIALS. CONDUCT THESE TESTS AT SUCH

AutoCAD SHX Text

PLACES AND WITH TIMING TO PERMIT WORK TO PROCEED WITH AS LITTLE

AutoCAD SHX Text

INTERRUPTION AS POSSIBLE. MAKE TEST BEFORE WORK IS CONCEALED.

AutoCAD SHX Text

B. TEST WATER PIPING TO HYDROSTATIC PRESSURE OF 150 PSI AND HOLD FOR

AutoCAD SHX Text

4 HOURS WITH LESS THAN 2 PSI LOSS IN PRESSURE.

AutoCAD SHX Text

D. AFTER THE INSTALLATION OF SANITARY PIPING AND BEFORE THE PIPE IS

AutoCAD SHX Text

CONCEALED OR THE FIXTURES ARE INSTALLED, CAP OR PLUG THE ENDS OF THE

AutoCAD SHX Text

SYSTEM AND FILL ALL LINES WITH WATER TO TOP OF VENTS (BUT NOT LESS THAN

AutoCAD SHX Text

10' OF HEAD), ALLOW TO STAND UNTIL A THOROUGH INSPECTION HAS BEEN

AutoCAD SHX Text

MADE. SHOULD LEAKS APPEAR, MAKE NECESSARY CORRECTIONS AND REPEAT

AutoCAD SHX Text

THE TESTS UNTIL THE SYSTEM IS TIGHT.

AutoCAD SHX Text

E. DO NOT USE RESIN, CANDLE WAX, OR ANY OTHER SUCH SUBSTANCE FOR

AutoCAD SHX Text

STOPPING LEAKS IN CAST IRON SOIL, WASTE OR VENT LINES. CAULKING OF

AutoCAD SHX Text

SCREW JOINTS TO STOP LEAKS WILL NOT BE PERMITTED.

AutoCAD SHX Text

F. LABEL ALL VALVES IN EQUIPMENT ROOM AS TO SERVICE AND FUNCTION WITH

AutoCAD SHX Text

BRASS TAGS. PLACE ON VALVES WITH STEEL RINGS. LABEL COLD WATER

AutoCAD SHX Text

PIPING, HOT WATER PIPING AND HOT WATER RETURN PIPING WITH PIPE MARKERS.

AutoCAD SHX Text

VALVE LABELS AND PIPE MARKERS SHALL BE SETON NAME PLATE CO.

AutoCAD SHX Text

IX. STERILIZATION

AutoCAD SHX Text

A. THE STERILIZATION PROCESS SHALL COMPLY WITH ALL GOVERNING

AutoCAD SHX Text

REGULATIONS AND WITH THE STERILIZATION PROCEDURES RECOMMENDED BY THE

AutoCAD SHX Text

AMERICAN WATER WORKS ASSOCIATION. THE CHLORINATION PROCESS MAY BE

AutoCAD SHX Text

SIMPLIFIED BY FIRST FLUSHING THE SYSTEM THOROUGHLY CLEAN, THEN CHARGING

AutoCAD SHX Text

WITH WATER CONTAINING A MINIMUM OF 50 PARTS PER MILLION OF CHLORINE,

AutoCAD SHX Text

ALLOWING THIS TO STAND FOR 24 HOURS, THEN THOROUGHLY FLUSHING. AFTER

AutoCAD SHX Text

STERILIZATION AND FINAL FLUSHING, THE LOCAL HEALTH AUTHORITY IS TO BE

AutoCAD SHX Text

NOTIFIED, AND THEIR FINAL APPROVAL OBTAINED IN WRITING.

AutoCAD SHX Text

END OF SECTION 15400

AutoCAD SHX Text

PVC PIPE SIZE MAXIMUM SPAN

AutoCAD SHX Text 1 1/2" 4'

AutoCAD SHX Text 2" 4'

AutoCAD SHX Text

PIPE SIZE

AutoCAD SHX Text

c. ZURN

AutoCAD SHX Text

d. JUST

AutoCAD SHX Text

e. ELKAY

AutoCAD SHX Text

f. EL MUSTEE

AutoCAD SHX Text

c. WATTS

AutoCAD SHX Text

d. GUY GRAY

AutoCAD SHX Text

CEILING SPACE IS USED FOR PLENUM RETURN OR PIPING SHALL BE INSULATED

AutoCAD SHX Text

TO MEET 25/50 SMOKE AND FLAME SPREAD RATING.

AutoCAD SHX Text 3" 4'

AutoCAD SHX Text 4" 4'

AutoCAD SHX Text

G. INSTALL…