White Horse Wildlife Management Area Storage Building - Design and Construction Documents
This document set consists of architectural, mechanical, plumbing, and electrical drawings and specifications for a storage building project for the West Virginia Division of Natural Resources, Wildlife Resources Section at White Horse Wildlife Management Area. The project includes construction of a storage facility with multiple functional spaces: unheated bays (101), office (103), bunk/storage (104), restroom (105), and storage (106). The scope of work encompasses HVAC systems with propane and electric heating, plumbing with water and sanitary systems, electrical power distribution and lighting, and fire alarm systems. The drawings indicate scale relationships at 3/16"=1'-0" and 1/4"=1'-0", with design completion dated August 4, 2020. The project number is 20024, and professional design services were provided by Chapman Technical Group with offices in St. Albans and Buckhannon, West Virginia, and GRW (a division providing architecture, civil engineering, and related services).
The specifications detail comprehensive installation requirements for all mechanical, plumbing, and electrical systems. HVAC equipment includes a 125 MBH propane unit heater (Reznor UDAS125), electric wall heaters, exhaust and supply fans, package terminal AC units (GE model), and motorized louvers, with all materials and labor responsibility assigned to the mechanical contractor. Plumbing systems specify Schedule 40 PVC piping for sanitary and storm drainage, Type L copper for hot and cold water service, and fixtures including Kohler lavatories and toilets, a Navien instantaneous water heater (150,000 BTU input), and a Bradley combination emergency shower/eyewash station. Electrical work requires 250-amp service with a panelboard, conduit installation per NEC standards, LED lighting fixtures from manufacturers including Lithonia and Cooper, and a fire alarm system with addressable smoke and heat detectors, manual pull stations, and audible/visual notification devices. All work must comply with current editions of applicable codes (International Plumbing Code, NEC, NFPA standards), include one-year warranties on materials and workmanship, and provide as-built drawings and operation manuals upon completion.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
L
L
SF
EF
EWH
HP
HP
STORAGE
BUNK/STORAGE
RESTROOM
OFFICE
UNHEATED
BAYS
HP
SF
GUH
T x x
AIRPORT PLANNING / DEVELOPMENT
ARCHITECTURE / INTERIOR DESIGN
CIVIL ENGINEERING / SITE DEVELOPMENT
ENVIRONMENTAL ENGINEERING
LANDSCAPE ARCHITECTURE
SURVEYING
St. Albans, WV
(304) 727-5501
Buckhannon, WV
(304) 472-8914 a division of
GRW
AutoCAD SHX Text MOUNT TOP OF LOUVER +12'-0" ABOVE FINISHED FLOOR. MOUNT TOP OF FAN +12'-0" ABOVE FINISHED FLOOR. MOUNT TOP OF WALL HEATER +6'-0" ABOVE FINISHED FLOOR. WALL CAP. MOUNT PACKAGE TERMINAL AC UNIT +8" ABOVE FINISHED FLOOR. MOUNT UNIT HEATER +9'-O" ABOVE FINISHED FLOOR. FRESH AIR AND VENT THROUGH WALL NEAR ROOF EVE. PROVIDE CONCENTRIC VENT KIT THROUGH WALL. INSULATE EACH INTERIOR PIPE TO PREVENT CONDENSATION.
AutoCAD SHX Text
%%UPLAN NOTES:
AutoCAD SHX Text A
AutoCAD SHX Text A
AutoCAD SHX Text A
AutoCAD SHX Text B
AutoCAD SHX Text B
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text D
AutoCAD SHX Text 6"%%C
AutoCAD SHX Text
MODEL NO.
AutoCAD SHX Text
MARK
AutoCAD SHX Text
ELECTRIC HEATER SCHEDULE
AutoCAD SHX Text
MBH
AutoCAD SHX Text
KW
AutoCAD SHX Text
CFM
AutoCAD SHX Text
VOLTS / PHASE
AutoCAD SHX Text
NOTES
AutoCAD SHX Text
MANUFACTURER
AutoCAD SHX Text
WEIGHT
AutoCAD SHX Text
(LBS)
AutoCAD SHX Text
%%UNOTES:
AutoCAD SHX Text
1) WALL HEATER WITH BUILT-IN THERMOSTAT CONTROL; THERMAL OVERLOAD; FAN DELAY SWITCH; POWER DISCONNECT SWITCH; SURFACE MOUNT CABINET.
AutoCAD SHX Text
EWH-1
AutoCAD SHX Text
QMARK
AutoCAD SHX Text
VOLTS / PHASE
AutoCAD SHX Text
EXHAUST AND SUPPLY FAN SCHEDULE
AutoCAD SHX Text
MARK
AutoCAD SHX Text
MANUFACTURER.
AutoCAD SHX Text
MODEL NO.
AutoCAD SHX Text
(LBS)
AutoCAD SHX Text
WEIGHT
AutoCAD SHX Text
CFM
AutoCAD SHX Text T.S.
AutoCAD SHX Text
S.P. (IN)
AutoCAD SHX Text
SONES
AutoCAD SHX Text
HP OR WATTS
AutoCAD SHX Text
NOTES
AutoCAD SHX Text
%%UNOTES:
AutoCAD SHX Text
SF-1
AutoCAD SHX Text
COOK
AutoCAD SHX Text
12XP40D15
AutoCAD SHX Text
AutoCAD SHX Text 1,250
AutoCAD SHX Text 4,605
AutoCAD SHX Text 0.125
AutoCAD SHX Text 1,465
AutoCAD SHX Text 8.7
AutoCAD SHX Text
1/8 HP
AutoCAD SHX Text 120V/1%%C
AutoCAD SHX Text 1,3
AutoCAD SHX Text
RPM
AutoCAD SHX Text
FAN
AutoCAD SHX Text
CWH
AutoCAD SHX Text
AutoCAD SHX Text 1.5
AutoCAD SHX Text 5.1
AutoCAD SHX Text 120V/1%%C
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
FLA
AutoCAD SHX Text 12.6
AutoCAD SHX Text
MCA
AutoCAD SHX Text 15.8
AutoCAD SHX Text
MOCP
AutoCAD SHX Text 20A
AutoCAD SHX Text
ELECTRICAL DATA
AutoCAD SHX Text
FLA
AutoCAD SHX Text 2.8
AutoCAD SHX Text
MCA
AutoCAD SHX Text 3.5
AutoCAD SHX Text
MOCP
AutoCAD SHX Text 20A
AutoCAD SHX Text
LP GAS UNIT HEATER SCHEDULE
AutoCAD SHX Text %%uNOTES
AutoCAD SHX Text
GUH-1
AutoCAD SHX Text
MARK
AutoCAD SHX Text
MANUFACTURER
AutoCAD SHX Text
MODEL NO.
AutoCAD SHX Text
WEIGHT
AutoCAD SHX Text
MBH
AutoCAD SHX Text
INPUT
AutoCAD SHX Text
CFM
AutoCAD SHX Text
NOTES
AutoCAD SHX Text
(LBS)
AutoCAD SHX Text
MBH
AutoCAD SHX Text
OUTPUT
AutoCAD SHX Text
VOLTS/PHASE
AutoCAD SHX Text
REZNOR
AutoCAD SHX Text
UDAS125
AutoCAD SHX Text
AutoCAD SHX Text 125.0
AutoCAD SHX Text 99.6
AutoCAD SHX Text 1/20
AutoCAD SHX Text 1,540
AutoCAD SHX Text
AutoCAD SHX Text 120V/1%%C
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
1) SEPERATED COMBUSTION, LOWSTATIC UNIT HEATER WITH CONCENTRIC VENT KIT AND WALL MOUNT THERMOSTAT.
AutoCAD SHX Text
FLA
AutoCAD SHX Text 5.1
AutoCAD SHX Text
MCA
AutoCAD SHX Text 6.4
AutoCAD SHX Text
MOCP
AutoCAD SHX Text 20A
AutoCAD SHX Text
FAN
AutoCAD SHX Text
HP
AutoCAD SHX Text
EAT
AutoCAD SHX Text
(%%DF)
AutoCAD SHX Text
LAT
AutoCAD SHX Text
(%%DF)
AutoCAD SHX Text
SF-2
AutoCAD SHX Text
COOK
AutoCAD SHX Text
12XP40D15
AutoCAD SHX Text
AutoCAD SHX Text 1,250
AutoCAD SHX Text 4,605
AutoCAD SHX Text 0.125
AutoCAD SHX Text 1,465
AutoCAD SHX Text 8.7
AutoCAD SHX Text
1/8 HP
AutoCAD SHX Text 120V/1%%C
AutoCAD SHX Text 1,3
AutoCAD SHX Text 2.8
AutoCAD SHX Text 3.5
AutoCAD SHX Text 20A
AutoCAD SHX Text
LOUVER SCHEDULE
AutoCAD SHX Text
(DAMPER)
AutoCAD SHX Text
MANUFACTURER
AutoCAD SHX Text
%%UNOTES:
AutoCAD SHX Text
MARK
AutoCAD SHX Text
MODEL NO.
AutoCAD SHX Text SIZE (WxH)
AutoCAD SHX Text
CFM
AutoCAD SHX Text
VOLTS/PHASE
AutoCAD SHX Text
MOD
AutoCAD SHX Text
NOTES
AutoCAD SHX Text
1) EXTRUDED ALUMINUM LOUVER WITH STANDARD FRAME; BIRDSREEN; INSECT SCREEN.
AutoCAD SHX Text
2) COLOR OF LOUVER SHALL BE SELECTED BY ARCH.
AutoCAD SHX Text L-1
AutoCAD SHX Text
RUSKIN
AutoCAD SHX Text
ELF375X
AutoCAD SHX Text 40"x20"
AutoCAD SHX Text 1,250
AutoCAD SHX Text
YES
AutoCAD SHX Text 120V/1%%C
AutoCAD SHX Text 1,2
AutoCAD SHX Text
USE
AutoCAD SHX Text
RELIEF
AutoCAD SHX Text
WITH
AutoCAD SHX Text
INTERLOCK
AutoCAD SHX Text
SF-1
AutoCAD SHX Text
ABBREVIATIONS
AutoCAD SHX Text
ABOVE FINISHED FLOOR
AutoCAD SHX Text
AFF
AutoCAD SHX Text
ELECTRIC WALL HEATER
AutoCAD SHX Text
ELECTRICAL CONTRACTOR
AutoCAD SHX Text
EWH
AutoCAD SHX Text
EXHAUST FAN
AutoCAD SHX Text
EF
AutoCAD SHX Text
EC
AutoCAD SHX Text
GENERAL CONTRACTOR
AutoCAD SHX Text
GC
AutoCAD SHX Text
LOUVER
AutoCAD SHX Text
MOTORIZED DAMPER
AutoCAD SHX Text L
AutoCAD SHX Text
MOD
AutoCAD SHX Text
WITHOUT
AutoCAD SHX Text
WITH
AutoCAD SHX Text
UNLESS NOTED OTHERWISE
AutoCAD SHX Text W/O
AutoCAD SHX Text W/
AutoCAD SHX Text
TYPICAL
AutoCAD SHX Text
UNO
AutoCAD SHX Text
(TYP)
AutoCAD SHX Text
NTS
AutoCAD SHX Text
NOT TO SCALE
AutoCAD SHX Text
MH
AutoCAD SHX Text
MOUNTING HEIGHT
AutoCAD SHX Text
CUBIC FEET PER MINUTE
AutoCAD SHX Text
CFM
AutoCAD SHX Text
ENTER AIR TEMPERATURE
AutoCAD SHX Text
EAT
AutoCAD SHX Text
ENERGY EFFICIENCY RATIO
AutoCAD SHX Text
EER
AutoCAD SHX Text
HORSEPOWER
AutoCAD SHX Text
HP
AutoCAD SHX Text
KILOWATTS
AutoCAD SHX Text
KW
AutoCAD SHX Text
LEAVING AIR TEMPERATURE
AutoCAD SHX Text
LAT
AutoCAD SHX Text
THOUSAND BTU/HR
AutoCAD SHX Text
MBH
AutoCAD SHX Text
REVOLUTIONS PER MINUTE
AutoCAD SHX Text
RPM
AutoCAD SHX Text
TIP SPEED
AutoCAD SHX Text
TS
AutoCAD SHX Text
WEATHER PROOF
AutoCAD SHX Text
WP
AutoCAD SHX Text
ELECTRIC UNIT HEATER
AutoCAD SHX Text
EUH
AutoCAD SHX Text L-2
AutoCAD SHX Text
RUSKIN
AutoCAD SHX Text
ELF375X
AutoCAD SHX Text 40"x20"
AutoCAD SHX Text 1,250
AutoCAD SHX Text
YES
AutoCAD SHX Text 120V/1%%C
AutoCAD SHX Text 1,2
AutoCAD SHX Text
RELIEF
AutoCAD SHX Text
SF-2
AutoCAD SHX Text
EF-1
AutoCAD SHX Text
COOK
AutoCAD SHX Text
GC-146
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 1,630
AutoCAD SHX Text 0.250
AutoCAD SHX Text
AutoCAD SHX Text 1.2
AutoCAD SHX Text 35 W
AutoCAD SHX Text 120V/1%%C
AutoCAD SHX Text 2,3
AutoCAD SHX Text 0.3
AutoCAD SHX Text 0.4
AutoCAD SHX Text 20A
AutoCAD SHX Text
%%UNOTES
AutoCAD SHX Text
MARK
AutoCAD SHX Text
MANUFACTURER
AutoCAD SHX Text
(LB)
AutoCAD SHX Text
WEIGHT
AutoCAD SHX Text
MODEL NO.
AutoCAD SHX Text
PACKAGED TERMINAL AC UNIT SCHEDULE
AutoCAD SHX Text
COOLING CAPACITY
AutoCAD SHX Text
MBH
AutoCAD SHX Text
TOTAL
AutoCAD SHX Text
EER
AutoCAD SHX Text
NOTES
AutoCAD SHX Text
GE
AutoCAD SHX Text
AutoCAD SHX Text
HP-1
AutoCAD SHX Text
AZ58H07D
AutoCAD SHX Text
AutoCAD SHX Text 7.3
AutoCAD SHX Text 13.0
AutoCAD SHX Text
1) ZONELINE UNIT WITH ARCHITECTURAL LOUVER; GALVANIZED STEEL WALL CASE; ROOM CABINET; CHASSIS; LINE CORD CONNECTION KIT WITH MALE PLUG. 2) UNIT MOUNTED 5800 SERIES CONTROLS. 3) COLOR OF LOUVER BY ARCHITECTURAL..
AutoCAD SHX Text
HEATING CAPACITY
AutoCAD SHX Text
MBH
AutoCAD SHX Text
TOTAL
AutoCAD SHX Text
COP
AutoCAD SHX Text 6.4
AutoCAD SHX Text 3.7
AutoCAD SHX Text
AUX. HEATER
AutoCAD SHX Text
MBH
AutoCAD SHX Text
TOTAL
AutoCAD SHX Text
KW
AutoCAD SHX Text 2.6
AutoCAD SHX Text
VOLTS/PHASE
AutoCAD SHX Text 240V/1%%C
AutoCAD SHX Text 8.6
AutoCAD SHX Text
AutoCAD SHX Text
(HIGH)
AutoCAD SHX Text
CFM
AutoCAD SHX Text
FLA
AutoCAD SHX Text 11.6
AutoCAD SHX Text
MCA
AutoCAD SHX Text 14.5
AutoCAD SHX Text
MOCA
AutoCAD SHX Text 20A
AutoCAD SHX Text
GE
AutoCAD SHX Text
AutoCAD SHX Text
HP-2
AutoCAD SHX Text
AZ58H12D
AutoCAD SHX Text
AutoCAD SHX Text 11.8
AutoCAD SHX Text 11.7
AutoCAD SHX Text 10.9
AutoCAD SHX Text 3.4
AutoCAD SHX Text 3.5
AutoCAD SHX Text 240V/1%%C
AutoCAD SHX Text 11.7
AutoCAD SHX Text
AutoCAD SHX Text 15.6
AutoCAD SHX Text 19.5
AutoCAD SHX Text 20A
AutoCAD SHX Text
3) SOLID STATE SPEED CONTROL (MOUNT ON SIDE OF FAN HOUSING).
AutoCAD SHX Text
2) DIRECT DRIVE CEILING FAN WITH BACKDRAFT DAMPER; GRILLE; POWER DISCONNECT; WALL CAP.
AutoCAD SHX Text
1) DIRECT DRIVE PACKAGE PROPELLER WALL SUPPLY FAN WITH OSHA WIRE GUARD; WALL COLLAR; SHUTTER; NON-FUSED POWER DISCONNECT; REMOTE WALL
AutoCAD SHX Text
MOUNT FAN SWITCH; RAIN HOOD.
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text
GE
AutoCAD SHX Text
AutoCAD SHX Text
HP-3
AutoCAD SHX Text
AZ58H12D
AutoCAD SHX Text
AutoCAD SHX Text 11.8
AutoCAD SHX Text 11.7
AutoCAD SHX Text 10.9
AutoCAD SHX Text 3.4
AutoCAD SHX Text 3.5
AutoCAD SHX Text 240V/1%%C
AutoCAD SHX Text 11.7
AutoCAD SHX Text
AutoCAD SHX Text 15.6
AutoCAD SHX Text 19.5
AutoCAD SHX Text 20A
AutoCAD SHX Text E
AutoCAD SHX Text B
AutoCAD SHX Text F
AutoCAD SHX Text F
AutoCAD SHX Text G
AutoCAD SHX Text T
AutoCAD SHX Text
GUH-1
AutoCAD SHX Text
SYMBOL LEGEND
AutoCAD SHX Text
SYNBOL
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
EQUIPMENT SYMBOL - SEE LIST ON DWGS.
AutoCAD SHX Text
THERMOSTAT
AutoCAD SHX Text A
AutoCAD SHX Text
PLAN NOTES
AutoCAD SHX Text
ROUND SHEET METAL DUCT
AutoCAD SHX Text 10"ø
AutoCAD SHX Text
DUCT SIZE - 10" DIAMETER
AutoCAD SHX Text G
AutoCAD SHX Text
HVAC PLAN
AutoCAD SHX Text
SCALE: 3/16"=1'-0"
AutoCAD SHX Text
HVAC PLAN AND SCHEDULES
AutoCAD SHX Text M1
AutoCAD SHX Text
REVISION
AutoCAD SHX Text
SHEET NO.
AutoCAD SHX Text
CHECKED BY:
AutoCAD SHX Text
DESIGNED BY:
AutoCAD SHX Text
DRAWN BY:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
JOB NUMBER:
AutoCAD SHX Text
SEAL
AutoCAD SHX Text
BY
AutoCAD SHX Text
DATE
AutoCAD SHX Text
REVISIONS
AutoCAD SHX Text
REVISION
AutoCAD SHX Text
NUMBER
AutoCAD SHX Text
PROJECT INFORMATION
AutoCAD SHX Text Chapman
AutoCAD SHX Text Technical
AutoCAD SHX Text Group
AutoCAD SHX Text www.chaptech.com
AutoCAD SHX Text
KMK
AutoCAD SHX Text
KMK
AutoCAD SHX Text
STAFF
AutoCAD SHX Text
AUGUST 4, 2020
AutoCAD SHX Text 1/4"=1'-0"
AutoCAD SHX Text 20024
AutoCAD SHX Text
AutoCAD SHX Text
DIVISION OF NATURAL RESOURCES
AutoCAD SHX Text
WILDLIFE RESOURCES SECTION
AutoCAD SHX Text
WHITE HORSE WILDLIFE MANAGEMENT AREA
AutoCAD SHX Text
STORAGE BUILDING
FAN FLANGE ON ALL FOUR SIDES MOUNT TO BUILDING
BUILDING FRAMING AROUND ALL FOUR SIDES OF FAN3
BUILDING SIDING2
1 BUILDING FRAMING
NOT TO SCALE
EXHAUST FAN
ADJUSTABLE MOUNTING ANGLE ON ALL FOUR SIDES MOUNT TO BUILDING
7 45 DEGREE WEATHER HOOD
8 BACKDRAFT LOUVER DAMPER
9 STAINLESS STEEL BIRDSCREEN
NOT TO SCALE
DAMPER
3 WALL
1 LOUVER
2 1
4 STAINLESS STEEL BIRDSCREEN
5 SHEET METAL SCREW ON ALL
FOUR SIDES AT 12" CENTER
TO CENTER
AIRPORT PLANNING / DEVELOPMENT
ARCHITECTURE / INTERIOR DESIGN
CIVIL ENGINEERING / SITE DEVELOPMENT
ENVIRONMENTAL ENGINEERING
LANDSCAPE ARCHITECTURE
SURVEYING
St. Albans, WV
(304) 727-5501
Buckhannon, WV
(304) 472-8914 a division of
GRW
AutoCAD SHX Text
%%UDETAIL OF PROPELLER WALL SUPPLY FAN
AutoCAD SHX Text
%%UDETAIL OF LOUVER
AutoCAD SHX Text
SECTION 15500 - HEATING, VENTILATION AND AIR CONDITIONING
AutoCAD SHX Text
GENERAL
AutoCAD SHX Text
1. DESCRIPTION OF THE WORK:
AutoCAD SHX Text
A. THE CONTRACTOR SHALL FURNISH AND INSTALL EQUIPMENT AS INDICATED ON
AutoCAD SHX Text
THE DRAWINGS. ITEMS NOT LISTED OR DETAILED, BUT REQUIRED FOR
AutoCAD SHX Text
INSTALLATION OF A COMPLETE, FULLY FUNCTIONAL HEATING, AIR CONDITIONING
AutoCAD SHX Text
AND VENTILATION SYSTEM SHALL BE FURNISHED AND INSTALLED BY THIS
AutoCAD SHX Text
CONTRACTOR.
AutoCAD SHX Text
B. THE EXTENT OF THE MECHANICAL WORK IS INDICATED ON THE DRAWINGS.
AutoCAD SHX Text
THIS CONTRACTOR SHALL BE RESPONSIBLE FOR INSTALLING FACTORY PROVIDED
AutoCAD SHX Text
ACCESSORIES.
AutoCAD SHX Text
C. THE ENTIRE INSTALLATION SHALL BE IN ACCORDANCE WITH THE DRAWINGS,
AutoCAD SHX Text
SPECIFICATIONS, APPLICABLE REQUIREMENTS OF THE MANUFACTURERS OF THE
AutoCAD SHX Text
EQUIPMENT AND LOCAL CODES REQUIREMENTS, AND IN ACCORDANCE WITH
AutoCAD SHX Text
SMACNA STANDARDS AND THE LATEST EDITIONS OF THE STATE BUILDING CODES,
AutoCAD SHX Text
NFPA-90A, AND NFPA-101.
AutoCAD SHX Text
II. OPERATION MANUALS
AutoCAD SHX Text
A. MAINTENANCE MANUALS AND INSTRUCTIONS: FURNISH THREE (3) SETS OF
AutoCAD SHX Text
COMPLETE OPERATING INSTRUCTIONS COVERING ENTIRE HEATING, VENTILATING AND
AutoCAD SHX Text
AIR CONDITIONING SYSTEM.
AutoCAD SHX Text
III. SYSTEM REQUIREMENTS
AutoCAD SHX Text
A. NOISE AND VIBRATION: EQUIPMENT SHALL OPERATE QUIETLY AND THE DESIGN
AutoCAD SHX Text
OF THE SUPPORTS SHALL BE SUCH THAT THE OPERATION OF THE EQUIPMENT
AutoCAD SHX Text
SHALL CAUSE NO PERCEPTIBLE VIBRATION IN THE FLOORING ADJACENT TO THE
AutoCAD SHX Text
EQUIPMENT, NOR CAUSE, DIRECTLY OR INDIRECTLY, VIBRATION OR OBJECTIONABLE
AutoCAD SHX Text
NOISE IN ANY OTHER PORTION OF THE BUILDING AND/OR IN THE BUILDING
AutoCAD SHX Text
STRUCTURE ITSELF.
AutoCAD SHX Text
B. FOUNDATIONS: FURNISH ALL FOUNDATIONS FOR EQUIPMENT COVERED IN THE
AutoCAD SHX Text
SPECIFICATIONS, AS A PART OF THIS SECTION, UNLESS OTHERWISE INDICATED ON
AutoCAD SHX Text
THE DRAWINGS.
AutoCAD SHX Text
IV. WARRANTY:
AutoCAD SHX Text
A. FURNISH A FIVE (5) YEAR WARRANTY ON ALL COMPRESSORS, A 10 YEAR
AutoCAD SHX Text
WARRANTY ON HEAT EXCHANGERS, AND A ONE (1) YEAR SERVICE AND
AutoCAD SHX Text
GUARANTEE ON ALL CONTROLS, COMPRESSORS, EQUIPMENT AND MATERIALS.
AutoCAD SHX Text
V. MECHANICAL SUBMITTALS
AutoCAD SHX Text
A. SUBMITTALS ARE REQUIRED ON THE FOLLOWING ITEMS:
AutoCAD SHX Text
1. PROPANE HEATERS
AutoCAD SHX Text
2. EXHAUST AND SUPPLY FANS
AutoCAD SHX Text
3. PTAC-UNITS
AutoCAD SHX Text
4. LOUVERS
AutoCAD SHX Text
VI. AS BUILT DRAWINGS
AutoCAD SHX Text
A. FURNISH THE OWNER WITH 3 SETS OF AS-BUILT DRAWINGS UPON
AutoCAD SHX Text
COMPLETION OF THE WORK.
AutoCAD SHX Text
PART 2 - PRODUCTS
AutoCAD SHX Text
I. SHEET METAL WORK. NOTE: THE INSTALLATION OF THE HVAC SYSTEM,
AutoCAD SHX Text
INCLUDING BUT NOT LIMITED TO, RETURN AND SUPPLY DROPS, TRUNK LINES,
AutoCAD SHX Text
BRANCH LINES AND DIFFUSERS SHALL BE COMPLETED IN SUCH A MANNER TO
AutoCAD SHX Text
PRESENT A SYSTEM SUITABLE FOR THE INTENDED PURPOSE. ANY PART OF THE
AutoCAD SHX Text
SYSTEM NOT CONFORMING TO THE ABOVE PURPOSE SHALL BE REMOVED AND
AutoCAD SHX Text
REPLACED BY THIS CONTRACTOR.
AutoCAD SHX Text
A. SUPPLY GALVANIZED SHEET METAL WORK IN ACCORDANCE WITH ASHRAE OR
AutoCAD SHX Text
SMACNA STANDARDS. SIZE OF DUCT INDICATED ON DRAWINGS IS FINISHED INSIDE
AutoCAD SHX Text
DIMENSION.
AutoCAD SHX Text
B. PROVIDE OFFSETS, ELBOWS, AND TRANSITIONS IN DUCTWORK WHERE
AutoCAD SHX Text
NECESSARY, WHETHER OR NOT SHOWN.
AutoCAD SHX Text
C. USE WEIGHTS, BRACING, JOINTS, AND ALL DETAILS IN ACCORDANCE WITH
AutoCAD SHX Text
SMACNA.
AutoCAD SHX Text
D. MAKE INTERIOR OF DUCT SMOOTH AND JOINTS AIR TIGHT. WHERE
AutoCAD SHX Text
NECESSARY TO ENSURE TIGHTNESS, CAULK JOINTS. MAKE THE ENTIRE
AutoCAD SHX Text
INSTALLATION RIGID WITH DUCTWORK FREE FROM RATTLES AND AIR NOISES WHEN
AutoCAD SHX Text
IN OPERATION.
AutoCAD SHX Text
E. MAKE ELBOWS WITH INSIDE RADIUS EQUAL TO THE WIDTH OF THE DUCT
AutoCAD SHX Text
EXCEPT WHERE OTHERWISE SPECIFIED OR NECESSITATED BY UNAVOIDABLE SPACE
AutoCAD SHX Text
CONDITIONS. WHERE INSIDE RADIUS IS LESS THAN 3/4 (THREE FOURTHS) THE
AutoCAD SHX Text
DUCT WIDTH, MULTIPLE TURNING VANES SHALL BE PROVIDED. PROVIDE SQUARE
AutoCAD SHX Text
ELBOWS WITH TUTTLE AND BAILEY "DUCTURNS" OR BARBER COLEMAN "AIRTURNS".
AutoCAD SHX Text
F. INCLUDE ANGLE OF DIVERGENCE FOR ENLARGEMENT NOT TO EXCEED 15
AutoCAD SHX Text
DEGREES WHERE SPACE CONDITIONS PERMIT. INCLUDED ANGLE OF CONVERGENCE
AutoCAD SHX Text
FOR CONTRACTING NOT TO EXCEED 30 DEGREES.
AutoCAD SHX Text
G. PROVIDE FLEXIBLE DUCT CONNECTIONS AT CONNECTION POINTS TO AC UNITS
AutoCAD SHX Text
FOR BOTH SUPPLY AND RETURN DUCTS, AND AT OTHER LOCATIONS INDICATED ON
AutoCAD SHX Text
THE DRAWINGS. FLEXIBLE CONNECTIONS ARE TO BE MADE WITH WOVEN CANVAS
AutoCAD SHX Text
COLLARS NOT LESS THAN TWO INCHES (2") LONG. SECURE COLLARS TO THE
AutoCAD SHX Text
DUCT AND FAN CONNECTIONS BY GALVANIZED CHANNELS. PROVIDE A BRAIDED
AutoCAD SHX Text
COPPER BRIDGE STRAP ACROSS FLEXIBLE CONNECTIONS. PROVIDE FLEXIBLE
AutoCAD SHX Text
CONNECTIONS AT CONNECTION TO EACH FAN.
AutoCAD SHX Text
I. INSTALL LOUVERS AS INDICATED.
AutoCAD SHX Text
PART 3 - EXECUTION
AutoCAD SHX Text
I. SUPERVISION OF ELECTRICAL WORK
AutoCAD SHX Text
A. THIS CONTRACTOR SHALL BE RESPONSIBLE FOR SUPERVISION OF ALL WIRING
AutoCAD SHX Text
(INCLUDING CONTROL WIRING) OF EQUIPMENT INCLUDED IN THIS SECTION AND
AutoCAD SHX Text
SHALL FURNISH ALL NECESSARY DIAGRAMS REQUIRED, INCLUDING CONTROL WIRING
AutoCAD SHX Text
DIAGRAMS. THIS CONTRACTOR SHALL MOUNT OR SUPERVISE MOUNTING OF ALL
AutoCAD SHX Text
CONTROL DEVICES.
AutoCAD SHX Text
II. PAINTING
AutoCAD SHX Text
A. EXCEPT AS SPECIFIED HEREIN, ALL PAINTING WILL BE DONE BY OTHERS.
AutoCAD SHX Text
LEAVE WORK FREE FROM RUST, DIRT, GREASE AND PLASTER.
AutoCAD SHX Text
B. EQUIPMENT WITH A FACTORY APPLIED FINISH SHALL HAVE SCRATCHES, CHIPS,
AutoCAD SHX Text
ETC. PRIMED AND TOUCHED UP WITH MATERIALS WHICH WILL PROTECT THE
AutoCAD SHX Text
SURFACE AND MATCH THE ADJACENT AREAS.
AutoCAD SHX Text
C. INTERIOR OF SHEETMETAL DUCT WHICH IS VISIBLE THROUGH REGISTERS OR
AutoCAD SHX Text
GRILLES SHALL BE PAINTED FLAT BLACK BY THIS CONTRACTOR.
AutoCAD SHX Text
III. CLEANING AND ADJUSTMENTS
AutoCAD SHX Text
A. UPON COMPLETION OF WORK, CLEAN, OIL AND GREASE ALL FANS, MOTORS,
AutoCAD SHX Text
OTHER RUNNING EQUIPMENT AND APPARATUS AND MAKE CERTAIN THAT ALL SUCH
AutoCAD SHX Text
APPARATUS AND MECHANISMS ARE IN PROPER WORKING ORDER AND MADE READY
AutoCAD SHX Text
FOR TEST.
AutoCAD SHX Text
IV. IDENTIFICATION
AutoCAD SHX Text
A. FURNISH AND INSTALL NAMEPLATES ON ALL HVAC EQUIPMENT PROVIDED BY
AutoCAD SHX Text
OWNER AND CONTRACTOR. NAMEPLATES SHALL BE MADE FROM WHITE ENGRAVING
AutoCAD SHX Text
STOCK WITH BLACK LETTERS AND BLACK FOUR EDGE BEVEL. WORDING SHALL
AutoCAD SHX Text
DESCRIBE ITEMS USING SAME DESIGNATION AS THE ELECTRICAL PANEL SCHEDULE,
AutoCAD SHX Text
AND NAMEPLATES SHALL BE ATTACHED USING PROPER SIZE AND TYPE
AutoCAD SHX Text
STAINLESS-STEEL BOLTS OR SELF-DRILLING SCREWS.
AutoCAD SHX Text
B. GLUE-ON, TAPE-ON OR TAPE TYPE NAMEPLATES ARE NOT ACCEPTABLE.
AutoCAD SHX Text
END OF SECTION 15500
AutoCAD SHX Text
1. PROVIDE ALL MATERIALS AND EQUIPMENT AND PERFORM ALL LABOR REQUIRED TO INSTALL COMPLETE AND OPERABLE HVAC SYSTEM AS INDICATED ON THE DRAWINGS, AS SPECIFIED AND AS REQUIRED BY CODE. 2. CERTAIN ITEMS SUCH AS RISES AND DROPS IN DUCTWORK, ARE INDICATED FOR CLARITY IN CERTAIN AREAS. THIS DOES NOT RELIEVE THE CONTRACTOR OF PROVIDED THESE ITEMS NOT SHOWN IN OTHER AREAS AS REQUIRED FOR A COMPLETE INSTALLATION. 3. UNLESS NOTED OTHERWISE, LOCATE ALL ROOM THERMOSTATS AND HUMIDISTAT 5'-0" ABOVE FINISH FLOOR. 4. ALL DUCTWORK SHALL CLEAR DOORS AND WINDOWS. 5. ALL DUCTWORK DIMENSIONS, AS SHOWN ON DRAWINGS, ARE INTERNAL CLEAR DIMENSIONS. DUCT SIZE SHALL BE INCREASED IN SIZE TO COMPENSATE FOR INTERNAL LININGS. 6. LOCATE ALL MECHANICAL EQUIPMENT FOR UNOBSTRUCTED ACCESS TO UNIT ACCESS PANELS, AND CONTROLS. 7. ALL DUCTS SHALL BE GROUNDED ACROSS FLEXIBLE CONNECTIONS WITH FLEXIBLE COPPER GROUNDING STRAPS. 8. CONTROL RELAYS SHALL BE FURNISHED AND WIRED BY THE ELECTRICAL CONTRACTOR. MECHANICAL CONTRACTOR SHALL BE RESPONSIBLE FOR MOUNTING THE RELAY IN THE EQUIPMENT. 9. COORDINATE INSTALLATION OF ALL HVAC EQUIPMENT, DUCTWORK, SUPPORTS, ETC. WITH STRUCTURAL DRAWINGS.
AutoCAD SHX Text
%%UGENERAL MECHANICAL NOTES:
AutoCAD SHX Text
5. GAS UNIT HEATERS
AutoCAD SHX Text
HVAC DETAILS AND SPECIFICATIONS
AutoCAD SHX Text M2
AutoCAD SHX Text
REVISION
AutoCAD SHX Text
SHEET NO.
AutoCAD SHX Text
CHECKED BY:
AutoCAD SHX Text
DESIGNED BY:
AutoCAD SHX Text
DRAWN BY:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
JOB NUMBER:
AutoCAD SHX Text
SEAL
AutoCAD SHX Text
BY
AutoCAD SHX Text
DATE
AutoCAD SHX Text
REVISIONS
AutoCAD SHX Text
REVISION
AutoCAD SHX Text
NUMBER
AutoCAD SHX Text
PROJECT INFORMATION
AutoCAD SHX Text Chapman
AutoCAD SHX Text Technical
AutoCAD SHX Text Group
AutoCAD SHX Text www.chaptech.com
AutoCAD SHX Text
KMK
AutoCAD SHX Text
KMK
AutoCAD SHX Text
STAFF
AutoCAD SHX Text
AUGUST 4, 2020
AutoCAD SHX Text 1/4"=1'-0"
AutoCAD SHX Text 20024
AutoCAD SHX Text
AutoCAD SHX Text
DIVISION OF NATURAL RESOURCES
AutoCAD SHX Text
WILDLIFE RESOURCES SECTION
AutoCAD SHX Text
WHITE HORSE WILDLIFE MANAGEMENT AREA
S A
N
SAN
STORAGE
BUNK/STORAGE
RESTROOM
OFFICE
UNHEATED
BAY
S A
N
AIRPORT PLANNING / DEVELOPMENT
ARCHITECTURE / INTERIOR DESIGN
CIVIL ENGINEERING / SITE DEVELOPMENT
ENVIRONMENTAL ENGINEERING
LANDSCAPE ARCHITECTURE
SURVEYING
St. Albans, WV
(304) 727-5501
Buckhannon, WV
(304) 472-8914 a division of
GRW
AutoCAD SHX Text
GRADE OR PAVING
AutoCAD SHX Text
CAST IRON CLEANOUT
AutoCAD SHX Text
WITH COVER FOR DUTY
AutoCAD SHX Text
REQ'D
AutoCAD SHX Text
(USE REDUCING TYPE WHERE
AutoCAD SHX Text
SEWER MATERIAL AND
AutoCAD SHX Text
SIZE AS SPECIFIED.
AutoCAD SHX Text
SURFACE CLEANOUT
AutoCAD SHX Text
NTS
AutoCAD SHX Text
PVC EXTENSION
AutoCAD SHX Text
SAME SIZE AS SEWER
AutoCAD SHX Text
UP TO 6"
AutoCAD SHX Text
PVC LONG SWEEP 1/4
AutoCAD SHX Text
BEND OR CAST IRON
AutoCAD SHX Text
COMB. "Y" & 1/8 BEND
AutoCAD SHX Text
REQ'D).
AutoCAD SHX Text
6" THICK 24" SQUARE
AutoCAD SHX Text
CONCRETE PAD SLOPE
AutoCAD SHX Text
AWAY FROM COVER
AutoCAD SHX Text
EXTEND CLEANOUT ABOVE GRADE
AutoCAD SHX Text
AS REQ'D TO DIVERT SURFACE
AutoCAD SHX Text
WATER AWAY FROM CLEANOUT
AutoCAD SHX Text
%%UDOWNSPOUT DETAIL
AutoCAD SHX Text
NTS
AutoCAD SHX Text
OR PAVING
AutoCAD SHX Text
FINISH GRADE
AutoCAD SHX Text
COVER
AutoCAD SHX Text
18" MIN.
AutoCAD SHX Text
FOUNDATION
AutoCAD SHX Text
PVC EIGHTH BEND
AutoCAD SHX Text
FOR WEIGHT & TYPE OF JOINT
AutoCAD SHX Text
PVC SOIL PIPE SEE SPECIFICATIONS
AutoCAD SHX Text
PVC EIGHTH BEND
AutoCAD SHX Text
DOWN SPOUT
AutoCAD SHX Text
CUT CAP TO RECEIVE
AutoCAD SHX Text
EXTERIOR WALL
AutoCAD SHX Text
DOWN SPOUT
AutoCAD SHX Text
PROVIDE SCH. 40 PVC CAP
AutoCAD SHX Text
%%UDS
AutoCAD SHX Text E
AutoCAD SHX Text 4"
AutoCAD SHX Text SEE CIVIL DRAWINGS FOR CONTINUATION. 4" SANITARY UP WITH TEST TEE AND CLEANOUT AT BASE. CONTINUE 4" VENT UP WITH 4" VENT THRU ROOF. 4" TRAPPED HUB DRAIN TO WITH 4"x6" INCREASER TO SERVE BACKFLOW PREVENTER. 2" VENT UP. SEE DOWNSPOUT DETAIL AND CIVIL DRAWINGS FOR CONTINUATION.
AutoCAD SHX Text A
AutoCAD SHX Text B
AutoCAD SHX Text C
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text
PLAN NOTES:
AutoCAD SHX Text
%%UDS
AutoCAD SHX Text E
AutoCAD SHX Text 4"
AutoCAD SHX Text
%%UDS
AutoCAD SHX Text E
AutoCAD SHX Text 4"
AutoCAD SHX Text
%%UFCO
AutoCAD SHX Text
%%USCO
AutoCAD SHX Text A
AutoCAD SHX Text 4"
AutoCAD SHX Text 4"
AutoCAD SHX Text 2"
AutoCAD SHX Text
%%U2"FD-A
AutoCAD SHX Text
%%U2"FD-A
AutoCAD SHX Text B
AutoCAD SHX Text
NOTE: SEE SHEET P2 FOR FIXTURE DESIGNATIONS
AutoCAD SHX Text 1 1/2"
AutoCAD SHX Text
%%U4"VTR
AutoCAD SHX Text
20" INV. BFF
AutoCAD SHX Text
23" INV. BFF
AutoCAD SHX Text C
AutoCAD SHX Text 4"
AutoCAD SHX Text D
AutoCAD SHX Text 3"
AutoCAD SHX Text
%%UDS
AutoCAD SHX Text E
AutoCAD SHX Text 4"
AutoCAD SHX Text
%%UDS
AutoCAD SHX Text E
AutoCAD SHX Text 4"
AutoCAD SHX Text
%%UFCO
AutoCAD SHX Text 2"
AutoCAD SHX Text 2"
AutoCAD SHX Text 1 1/2"
AutoCAD SHX Text
%%UDS
AutoCAD SHX Text E
AutoCAD SHX Text 4"
AutoCAD SHX Text D
AutoCAD SHX Text 4"
AutoCAD SHX Text 4"
AutoCAD SHX Text
%%U4"FD-B
AutoCAD SHX Text
DRAINAGE AND VENT PLAN
AutoCAD SHX Text
SCALE: 3/16"=1'-0"
AutoCAD SHX Text
DRAINAGE AND VENT PLAN
AutoCAD SHX Text P1
AutoCAD SHX Text
REVISION
AutoCAD SHX Text
SHEET NO.
AutoCAD SHX Text
CHECKED BY:
AutoCAD SHX Text
DESIGNED BY:
AutoCAD SHX Text
DRAWN BY:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
JOB NUMBER:
AutoCAD SHX Text
SEAL
AutoCAD SHX Text
BY
AutoCAD SHX Text
DATE
AutoCAD SHX Text
REVISIONS
AutoCAD SHX Text
REVISION
AutoCAD SHX Text
NUMBER
AutoCAD SHX Text
PROJECT INFORMATION
AutoCAD SHX Text Chapman
AutoCAD SHX Text Technical
AutoCAD SHX Text Group
AutoCAD SHX Text www.chaptech.com
AutoCAD SHX Text
KMK
AutoCAD SHX Text
KMK
AutoCAD SHX Text
STAFF
AutoCAD SHX Text
AUGUST 4, 2020
AutoCAD SHX Text 1/4"=1'-0"
AutoCAD SHX Text 20024
AutoCAD SHX Text
AutoCAD SHX Text
DIVISION OF NATURAL RESOURCES
AutoCAD SHX Text
WILDLIFE RESOURCES SECTION
AutoCAD SHX Text
WHITE HORSE WILDLIFE MANAGEMENT AREA
S
WH
STORAGE
BUNK/STORAGE
RESTROOM
OFFICE
HEATED
BAYS
GUH
AIRPORT PLANNING / DEVELOPMENT
ARCHITECTURE / INTERIOR DESIGN
CIVIL ENGINEERING / SITE DEVELOPMENT
ENVIRONMENTAL ENGINEERING
LANDSCAPE ARCHITECTURE
SURVEYING
St. Albans, WV
(304) 727-5501
Buckhannon, WV
(304) 472-8914 a division of
GRW
AutoCAD SHX Text
PROPANE PIPING
AutoCAD SHX Text P
AutoCAD SHX Text
FLOOR CLEANOUT
AutoCAD SHX Text
WALL HYDRANT
AutoCAD SHX Text
SURFACE CLEANOUT
AutoCAD SHX Text
FIXTURE DESIGNATION
AutoCAD SHX Text
FLOOR DRAIN
AutoCAD SHX Text
PLAN NOTE
AutoCAD SHX Text
WH
AutoCAD SHX Text A
AutoCAD SHX Text
%%UP-1
AutoCAD SHX Text
%%USCO
AutoCAD SHX Text
%%UFD
AutoCAD SHX Text
SHOCK ABSORBER, LETTER
AutoCAD SHX Text
%%UFCO
AutoCAD SHX Text
PLUMBING SYMBOL LEGEND
AutoCAD SHX Text
SANITARY SEWER
AutoCAD SHX Text
STORM PIPING
AutoCAD SHX Text
HOT WATER PIPE (HW)
AutoCAD SHX Text
COLD WATER PIPE (CW)
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
ST
AutoCAD SHX Text
SAN
AutoCAD SHX Text
VENT PIPING
AutoCAD SHX Text
SYMBOL
AutoCAD SHX Text
PROPANE VALVE IN VERTICAL
AutoCAD SHX Text
PROPANE VALVE
AutoCAD SHX Text
CHECK VALVE
AutoCAD SHX Text
BALL VALVE
AutoCAD SHX Text
VENT THRU ROOF
AutoCAD SHX Text
TURN UP OR FROM BELOW
AutoCAD SHX Text
TURN DOWN
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
UNION
AutoCAD SHX Text
VTR
AutoCAD SHX Text
SYMBOL
AutoCAD SHX Text A
AutoCAD SHX Text
DESIGNATES SIZE
AutoCAD SHX Text
ABOVE FINISHED FLOOR
AutoCAD SHX Text
AFF
AutoCAD SHX Text
BELOW FINISH FLOOR
AutoCAD SHX Text
BFF
AutoCAD SHX Text
DOWN
AutoCAD SHX Text
DN
AutoCAD SHX Text
GENERAL CONTRACTOR
AutoCAD SHX Text
GC
AutoCAD SHX Text
PLUMBING CONTRACTOR
AutoCAD SHX Text
PC
AutoCAD SHX Text
WITH
AutoCAD SHX Text
VENT THRU ROOF
AutoCAD SHX Text W/
AutoCAD SHX Text
VTR
AutoCAD SHX Text
TYPICAL
AutoCAD SHX Text
(TYP)
AutoCAD SHX Text
NTS
AutoCAD SHX Text
NOT TO SCALE
AutoCAD SHX Text
BRITISH THERMAL UNIT
AutoCAD SHX Text
BTU
AutoCAD SHX Text
GALLON PER MINUTE
AutoCAD SHX Text
GPM
AutoCAD SHX Text
PLAN NOTES:
AutoCAD SHX Text A
AutoCAD SHX Text 1" WATER SERVICE FROM WELL. SEE CIVIL DRAWINGS AND COORDINATE WITH G.C.. WATER ENTRANCE, SEE DETAIL THIS SHEET. WATER HEATING, SEE DETAIL ON SHEET P3. CONTINUOUS 1/2" PIPING BELOW SLAB TO SERVE S-1 SINK. S-1 SINK. SINK. EMERGENCY STATION, SEE DETAIL THIS SHEET. HOSE BIB AT 30" WITH SERVICE BALL VALVE IN VERTICAL FOR SERVICE. COORDINATE WITH ELECTRICIAN. BALL VALVE WITH DRAIN FEATURE. PROPANE SERVICE LINE AND REGULATOR BY PROPANE PROVIDER. CONNECTED LOAD IS 275,000 BTU'S. CONTRACTOR SHALL CONNECT TO REGULATOR. NOTE: PROPANE TANK LOCATION SHALL BE PROPANE TANK LOCATION SHALL BE FIELD COORDINATED DURING CONSTRUCTION. SLEEVE AND SEAL GAS LINE THRU WALL WITH LINK TYPE SEAL. MAKE CONNECTION TO UNIT HEATER WITH VALVE UNION AND DIRT LEG. 2" COMBUSTION AIR AND VENT PIPING FOR WATER HEATER. INSULATE EACH TO PREVENT SWEATING. WATER HEATING CONCENTRIC VENT THRU WALL NEAR EVE OF METAL BUILDING.
AutoCAD SHX Text B
AutoCAD SHX Text C
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text F
AutoCAD SHX Text
%%UWH
AutoCAD SHX Text 3/4"
AutoCAD SHX Text
%%UL-1H
AutoCAD SHX Text
%%UWC-1H
AutoCAD SHX Text
%%USH-1H
AutoCAD SHX Text
%%US-1
AutoCAD SHX Text A
AutoCAD SHX Text C
AutoCAD SHX Text
%%UICB
AutoCAD SHX Text
%%UWS-1
AutoCAD SHX Text
%%UWH
AutoCAD SHX Text D
AutoCAD SHX Text
REDUCER TYP.
AutoCAD SHX Text
%%UHB
AutoCAD SHX Text F
AutoCAD SHX Text G
AutoCAD SHX Text
%%UHB
AutoCAD SHX Text F
AutoCAD SHX Text 1/2"
AutoCAD SHX Text 3/4"
AutoCAD SHX Text 3/4"
AutoCAD SHX Text 3/4"
AutoCAD SHX Text 3/4"
AutoCAD SHX Text 3/4"
AutoCAD SHX Text 1"
AutoCAD SHX Text 3/4"
AutoCAD SHX Text G
AutoCAD SHX Text H
AutoCAD SHX Text 3/4"
AutoCAD SHX Text H
AutoCAD SHX Text J
AutoCAD SHX Text K
AutoCAD SHX Text J
AutoCAD SHX Text K
AutoCAD SHX Text
DOWN
AutoCAD SHX Text
%%UWATER WELL ENTRANCE DETAIL
AutoCAD SHX Text
NTS
AutoCAD SHX Text R
AutoCAD SHX Text 1"
AutoCAD SHX Text
AutoCAD SHX Text 1"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
NOTES:
AutoCAD SHX Text
AutoCAD SHX Text 1" INCOMING WATER SERVICE SLEEVE AND SEAL THRU SLAB. BUILDING SHUT OFF VALVE. PRESSURE TANK AMTROL WX-250D VERTICAL 44 GALLON EXPANSION TANK WITH BASE. 1" PRO-PLUMBER BRASS TEE WITH (2) 1/4" CONNECTIONS FOR PRESSURE SWITCH AND PRESSURE GAUGE AND (2) 3/4" CONNECTIONS FOR DRAIN VALVE AND PRESSURE RELIEF VALVE. PRESSURE SWITCH. PRESSURE GAUGE. DRAIN VALVE. PRESSURE RELIEF VALVE SET AT 100 PSI.
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
PRESSURE TANK SHOWN ABOVE CONNECTION FOR CLARITY
AutoCAD SHX Text
SUPPLY TO BUILDING
AutoCAD SHX Text
%%UEMERGENCY STATION RISER
AutoCAD SHX Text
NTS
AutoCAD SHX Text
FLOOR SUPPORT
AutoCAD SHX Text
WALL SUPPORT TYP.
AutoCAD SHX Text
1 1/4" TEPID
AutoCAD SHX Text
EMERGENCY
AutoCAD SHX Text
%%UEMV-1
AutoCAD SHX Text 1"
AutoCAD SHX Text 3/4"
AutoCAD SHX Text
EMERGENCY
AutoCAD SHX Text
ES-1
AutoCAD SHX Text
MIXING VALVE
AutoCAD SHX Text
WATER SUPPLY
AutoCAD SHX Text
STATION
AutoCAD SHX Text
%%UES-1
AutoCAD SHX Text
%%UTMV-1
AutoCAD SHX Text E
AutoCAD SHX Text 3/4"
AutoCAD SHX Text 1"
AutoCAD SHX Text B
AutoCAD SHX Text
PUMP DISCONNECT
AutoCAD SHX Text
PUMP POWER CIRCUIT
AutoCAD SHX Text
AutoCAD SHX Text
MBH
AutoCAD SHX Text P
AutoCAD SHX Text 3/4"
AutoCAD SHX Text 1"
AutoCAD SHX Text M
AutoCAD SHX Text L
AutoCAD SHX Text L
AutoCAD SHX Text M
AutoCAD SHX Text
PIPING PLAN
AutoCAD SHX Text
SCALE: 3/16"=1'-0"
AutoCAD SHX Text
PIPING PLAN
AutoCAD SHX Text P2
AutoCAD SHX Text
REVISION
AutoCAD SHX Text
SHEET NO.
AutoCAD SHX Text
CHECKED BY:
AutoCAD SHX Text
DESIGNED BY:
AutoCAD SHX Text
DRAWN BY:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
JOB NUMBER:
AutoCAD SHX Text
SEAL
AutoCAD SHX Text
BY
AutoCAD SHX Text
DATE
AutoCAD SHX Text
REVISIONS
AutoCAD SHX Text
REVISION
AutoCAD SHX Text
NUMBER
AutoCAD SHX Text
PROJECT INFORMATION
AutoCAD SHX Text Chapman
AutoCAD SHX Text Technical
AutoCAD SHX Text Group
AutoCAD SHX Text www.chaptech.com
AutoCAD SHX Text
KMK
AutoCAD SHX Text
KMK
AutoCAD SHX Text
STAFF
AutoCAD SHX Text
AUGUST 4, 2020
AutoCAD SHX Text 1/4"=1'-0"
AutoCAD SHX Text 20024
AutoCAD SHX Text
AutoCAD SHX Text
DIVISION OF NATURAL RESOURCES
AutoCAD SHX Text
WILDLIFE RESOURCES SECTION
AutoCAD SHX Text
WHITE HORSE WILDLIFE MANAGEMENT AREA
P
WALL
AIRPORT PLANNING / DEVELOPMENT
ARCHITECTURE / INTERIOR DESIGN
CIVIL ENGINEERING / SITE DEVELOPMENT
ENVIRONMENTAL ENGINEERING
LANDSCAPE ARCHITECTURE
SURVEYING
St. Albans, WV
(304) 727-5501
Buckhannon, WV
(304) 472-8914 a division of
GRW
AutoCAD SHX Text
WALL
AutoCAD SHX Text
FLOOR/
AutoCAD SHX Text 1/2"
AutoCAD SHX Text 1/2"
AutoCAD SHX Text 1 1/2"
AutoCAD SHX Text 1 1/2"
AutoCAD SHX Text
WS-1
AutoCAD SHX Text EL MUSTEE MODEL #17F LAUNDRY TUB ONE-PIECE MOLDED CONSTRUCTION USING DURASTONE, A BLEND OF NATURAL CRUSHED STONE AND POLYESTER RESINS. TUB TO INCLUDE BUILT-IN SCRUB BOARD, INTEGRALLY MOLDED DRAIN ASSEMBLY, WALL MOUNTING HARDWARE, HEAVY GAUGE STEEL LEGS WITH BUILT-IN LEVELERS. 19 GALLON CAPACITY TUB, 13” DEEP. SHALL MEET ANSI SPECIFICATION DEEP. SHALL MEET ANSI SPECIFICATION Z 124-2011. COLOR: WHITE. INCLUDE FAUCET BLOCK AND FAUCET WITH VACUUM BREAKER.
AutoCAD SHX Text
REMARKS
AutoCAD SHX Text
MANUFACTURER
AutoCAD SHX Text
MODEL
AutoCAD SHX Text
MARK
AutoCAD SHX Text
SPECIALTY SCHEDULE
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
%%UFD-A
AutoCAD SHX Text
ZURN
AutoCAD SHX Text
ZN-415-5B
AutoCAD SHX Text
RESTROOM
AutoCAD SHX Text
FLOOR DRAIN
AutoCAD SHX Text S-1
AutoCAD SHX Text 1/2"
AutoCAD SHX Text 1/2"
AutoCAD SHX Text 1 1/2"
AutoCAD SHX Text 1 1/2"
AutoCAD SHX Text
COUNTER
AutoCAD SHX Text
COUNTER SINK; JUST MODEL #DL2233-A-GR, 18 GAUGE
AutoCAD SHX Text
STAINLESS STEEL SINK PUNCHED 8" ON CENTER FOR ZURN
AutoCAD SHX Text
T&S #B-2731 FAUCET, LESS SPRAYER. PROVIDE STRAINER
AutoCAD SHX Text
BASKETS, WHEEL STOPS, SUPPLIES AND TRAP.
AutoCAD SHX Text
DROP IN
AutoCAD SHX Text
FIXTURE SCHEDULE
AutoCAD SHX Text
MARK
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
HW
AutoCAD SHX Text
CW
AutoCAD SHX Text
SAN
AutoCAD SHX Text
MOUNTING
AutoCAD SHX Text
VENT
AutoCAD SHX Text
HEIGHT
AutoCAD SHX Text 2"
AutoCAD SHX Text
SET
AutoCAD SHX Text
FLOOR
AutoCAD SHX Text 3"
AutoCAD SHX Text
AutoCAD SHX Text 1/2"
AutoCAD SHX Text
WC-1H
AutoCAD SHX Text L-1H
AutoCAD SHX Text
RIM
AutoCAD SHX Text
34" TO
AutoCAD SHX Text 1/2"
AutoCAD SHX Text 1/2"
AutoCAD SHX Text 1 1/2"
AutoCAD SHX Text 1 1/2"
AutoCAD SHX Text CAST IRON BODY WITH BOTTOM OUTLET AND ADJUSTABLE 5" ROUND NICKEL BRONZE STRAINER. PROVIDE "SURE SEAL" TRAP PRIMER IN DRAIN.
AutoCAD SHX Text
SH-1H
AutoCAD SHX Text 1/2"
AutoCAD SHX Text 1/2"
AutoCAD SHX Text 1 1/2"
AutoCAD SHX Text 2"
AutoCAD SHX Text
ADA
AutoCAD SHX Text CLARION MODEL MP3837BF34CD 34" STALL-ONE PIECE THREE WALL FIBERGLASS REINFORCED POLYESTER RESIN SHOWER STALL WITH INTEGRAL NAILING FLANGE OUTSIDE DIM. 38" WIDE, 38" DEEP 78" HIGH. UNIT MEETS REQUIREMENTS OF ANSI Z124.2 FOR PLASTIC SHOWERS. FURNISH UNIT ACCESSORIZED WITH #503218 GRAB BAR, #5018GRAB BAR, #660 SOAP LEDGES, #400 N/L-LH-32"SDL FOLDING SEAT, BRASS DRAIN. SHOWER TRIM; #CH-SSMV-1 MIXING VALVE WITH LIMIT STOP. #ZHGB-24 HAND HELD SHOWER. #IN-36 CURTAIN ROD. UNIT SHALL BE INSTALLED ADA COMPLIANT. FURNISH AND INSTALL CLARION COLLAPSIBLE THRESHOLD WITH 2.5 END CAPS.
AutoCAD SHX Text
GENERAL NOTES:
AutoCAD SHX Text
1. PERFORM ALL WORK IN ACCORDANCE WITH CURRENT EDITION OF INTERNATIONAL PLUMBING CODE AND ALL APPLICABLE LOCAL CODES AND ORDINANCES. 2. CONTRACTOR SHALL VISIT SITE TO VERIFY ALL EXISTING CONDITIONS THAT MAY AFFECT WORK. 3. CONTRACT SHALL INCLUDE ALL MATERIALS, LABOR, TOOLS, ETC., FOR A COMPLETE AND OPERABLE INSTALLATION. ALL MATERIALS SHALL BE NEW, SPECIFICATION GRADE, AND U.L. LISTED PRODUCTS, UNLESS NOTED OTHERWISE. 4. COORDINATE ALL WORK AND SCHEDULES WITH OWNER, ARCHITECT AND OTHER CONTRACTORS. 5. STORE MATERIALS WHERE DIRECTED. PROTECT STORED MATERIALS AND INSTALLED WORK FROM DAMAGE. REPLACE ALL DAMAGED ITEMS WITH NEW. 6. REMOVE DIRT, DEBRIS AND UNUSED MATERIALS FROM SITE REGULARLY AND DISPOSE OF BY PROPER AND LEGAL METHODS. 7. PROVIDE UNIONS AND VALVES AT ALL EQUIPMENT. 8. PROVIDE PROPER SEALS AND FIRE STOPPING AT ALL WALL AND CEILING PENETRATIONS. REFER TO ARCHITECTURAL DRAWINGS FOR LOCATIONS AND RATINGS FOR WALLS AND CEILINGS.
AutoCAD SHX Text
9. PERFORM TESTING AND MAKE FINAL ADJUSTMENTS TO VERIFY PROPER PERFORM TESTING AND MAKE FINAL ADJUSTMENTS TO VERIFY PROPER PERFORMANCE OF ALL SYSTEMS AND EQUIPMENT. 10. MAINTAIN "AS BUILT" RECORDS OF ALL INSTALLED ITEMS AND PROVIDE TO ARCHITECT AT PROJECT COMPLETION. 11. MOUNT ALL HANDICAP ACCESSIBLE DEVICES AND EQUIPMENT PER UNIFORM FEDERAL ACCESSIBILITY STANDARDS (UFAS) 12. COORDINATE ALL SANITARY, VENT, DOMESTIC AND PROPANE PIPING ELEVATIONS WITH OTHER CONTRACTORS PRIOR TO INSTALLING ANY PIPING. 13. PIPING SHALL NOT BE ROUTED ABOVE ELECTRIC PANELS. 14. ALL PIPING IN EXTERIOR WALLS TO BE RUN ON BUILDING SIDE OF ALL PIPING IN EXTERIOR WALLS TO BE RUN ON BUILDING SIDE OF INSULATION. 15. COORDINATE PIPING IN TOILET AREAS WITH RECESSED TOILET ACCESSORIES. COORDINATE PIPING IN TOILET AREAS WITH RECESSED TOILET ACCESSORIES. OFFSET PIPING AS REQUIRED TO ALLOW RECESS OF THESE ITEMS. SEE ENLARGED TOILET PLANS FOR LOCATIONS. 16. VENT PIPING THROUGH METAL ROOFING SHALL BE PAINTED TO MATCH ROOF VENT PIPING THROUGH METAL ROOFING SHALL BE PAINTED TO MATCH ROOF 17. ALL EXTERIOR PROPANE PIPING SHALL BE PRIMED AND PAINTED WITH TWO ALL EXTERIOR PROPANE PIPING SHALL BE PRIMED AND PAINTED WITH TWO COATS OF EPOXY.
AutoCAD SHX Text 1 1/2"
AutoCAD SHX Text 1"
AutoCAD SHX Text 1 1/2"
AutoCAD SHX Text 1 1/2"
AutoCAD SHX Text
%%UES-1
AutoCAD SHX Text
%%UEMV-1
AutoCAD SHX Text
WALL
AutoCAD SHX Text
FLOOR/
AutoCAD SHX Text COMBININATION EMERGENCY SHOWER EYE/FACE WASH: BRADLEY NO. S19-310PTT SHOWER HEAD AND EYE WASH BOWL CONSTRUCTED OF STAINLESS STEEL, CROME-PLATED BRASS 1" IPS STAY-OPEN BALL VALVE, TWIN PERFORATED DISC/FACED WASH HEADS WITH PROTECTIVE POP-OFF SPRAY HEAD COVERS, PIPE AND FITTINGS TO 1 1/4" GALVANIZED STEEL, 1 1/4" IPS WATER SUPPLY FROM BRADLEY S19-2200 THERMOSTATIC MIXING VALVE.
AutoCAD SHX Text
%%UFCO
AutoCAD SHX Text
%%USCO
AutoCAD SHX Text
HYDRANT (CW)
AutoCAD SHX Text
RECESSED WALL
AutoCAD SHX Text
%%UWH
AutoCAD SHX Text Z-1320
AutoCAD SHX Text
ZURN
AutoCAD SHX Text
ZURN
AutoCAD SHX Text
ZN-1400 NL
AutoCAD SHX Text
FLOOR CLEANOUT
AutoCAD SHX Text
ICE MAKER
AutoCAD SHX Text
%%UICB
AutoCAD SHX Text
BIM875
AutoCAD SHX Text
GUY GRAY
AutoCAD SHX Text
CONNECTION BOX
AutoCAD SHX Text RECESSED 16 GAUGE STEEL BOX WITH EPOXY FINISH 1/2"x1/4" COMPRESSION ANGLE VALVE.
AutoCAD SHX Text BRONZE NICKEL PLATED QUARTER TURN NON-FREEZE HYDRANT WITH HOSE CONNECTION, INTEGRAL VACUUM BREAKER, "T" HANDLE KEY, AND STAINLESS STEEL BOX WITH FULL 180° COVER OPENING.
AutoCAD SHX Text ADJUSTABLE FLOOR CLEANOUT CAST IRON BODY WITH GAS & WATER TIGHT ABS TAPERED THREAD PLUG AND ROUND NICKEL BRONZE ADJUSTABLE TOP.
AutoCAD SHX Text
EXPOSED HOSE BIB
AutoCAD SHX Text
%%UHB
AutoCAD SHX Text
PRIER
AutoCAD SHX Text
C-158NP.75
AutoCAD SHX Text EXPOSED, NICKEL-CHROME PLATED FINISH, CAST BRASS BODY, SOLID BRASS STEM, 3/4" HOSE CONNECTION, STANDARD HANDLE, AND PRIER MODEL P-002CP VACUUM BREAKER, ASSE 1011.
AutoCAD SHX Text
%%UFD-B
AutoCAD SHX Text
ZURN
AutoCAD SHX Text
ZN-415-9B
AutoCAD SHX Text
FLOOR DRAIN
AutoCAD SHX Text CAST IRON BODY WITH BOTTOM OUTLET AND ADJUSTABLE 9" ROUND NICKEL BRONZE STRAINER. PROVIDE "SURE SEAL" TRAP PRIMER IN DRAIN.
AutoCAD SHX Text 1"
AutoCAD SHX Text
CONDENSATE
AutoCAD SHX Text WH-1 WATER HEATER: NAVIEN NPE-180A INSTANTANEOUS HEATER; 150,000 BTU WATER HEATER: NAVIEN NPE-180A INSTANTANEOUS HEATER; 150,000 BTU INPUT; 96% EFFICIENCY; CONDENSING; DUAL STAINLESS STEEL HEAT EXCHANGER; CONCENTRIC VENTING; MICROPROCESSOR CONTROL; AIR PRESSURE SENSOR ON COMBUSTION AIR; GAS PRESSURE SENSOR; LEAK DETECTOR; AIR INTAKE FILTER; 53.6 GPM @ 77° TEMPERATURE RISE; 15 YEAR HEAT EXCHANGER WARRANTY; 5YEAR WARRANTY ON PARTS AND COMPONENTS; 1 YEAR LABOR WARRANTY. 199 MBH INPUT; 2" PVC INTAKE AND EXHAUST WITH CONCENTRIC VENTING.
AutoCAD SHX Text
%%UWATER HEATING EQUIPMENT
AutoCAD SHX Text SCHEMATIC ONLY, WATER HEATING SYSTEM SHALL BE INSTALLED PER MANUFACTURERS WRITTEN INSTALLATION MANUAL INCLUDING HORIZONTAL VENTING AND COMBUSTION AIR PIPING.
AutoCAD SHX Text
NOTE:
AutoCAD SHX Text
PRESSURE RELIEF VALVE
AutoCAD SHX Text
BOILER DRAIN VALVE
AutoCAD SHX Text
UNION
AutoCAD SHX Text
BALL VALVE
AutoCAD SHX Text
%%UWATER HEATING SYMBOLS
AutoCAD SHX Text
%%UWATER HEATER SCHEMATIC
AutoCAD SHX Text
NTS
AutoCAD SHX Text
%%UWH-1
AutoCAD SHX Text 3/4"
AutoCAD SHX Text 3/4"
AutoCAD SHX Text
%%UCONCENTRIC VENTING
AutoCAD SHX Text
WATER HEATER.
AutoCAD SHX Text
CONCENTRIC KIT FURNISHED WITH
AutoCAD SHX Text
2" SCH. 40 PVC VENT PIPE AND
AutoCAD SHX Text
2" SCH. 40 PVC AIR INTAKE PIPE
AutoCAD SHX Text
FROM HEATER, SEAL PIPING
AutoCAD SHX Text
THROUGH WALL. TERMINATE WITH
AutoCAD SHX Text
GAS VALVE
AutoCAD SHX Text
TO F.D.
AutoCAD SHX Text KOHLER #K3979 ELONGATED WATER CLOSET FLOOR SET, SIPHON JET, VITREOUS CHINA, REVERSE TRAP, LOW CONSUMPTION, ELONGATED, DIRECT FEED SIPHON JET ACTION, TWO PIECE TOILET, WHITE ELONGATED OLSONITE #95 OPEN FRONT SEAT LESS COVER WITH STAINLESS CHECK HINGE AND CLOSET BOLT/WAX RING KIT.
AutoCAD SHX Text KOHLER #K2005 20"X18" WALL LAVATORY, WHITE WITH PUNCHING ON 4" CENTERS FOR T&S B-1141 FAUCET, GRID STRAINER, TRAP, TAILPIECE, WHEEL STOPS AND JR SMITH #0710 CHAIR TYPE CONCEALED ARM CARRIER. COMBINATION TRAP AND SUPPLY WRAP PROTECTOR KIT.
AutoCAD SHX Text
PIPING
AutoCAD SHX Text
CONCEALED
AutoCAD SHX Text
IN WALL
AutoCAD SHX Text
PLUMBING SCHEDULES DETAILS AND NOTES
AutoCAD SHX Text P3
AutoCAD SHX Text
REVISION
AutoCAD SHX Text
SHEET NO.
AutoCAD SHX Text
CHECKED BY:
AutoCAD SHX Text
DESIGNED BY:
AutoCAD SHX Text
DRAWN BY:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
JOB NUMBER:
AutoCAD SHX Text
SEAL
AutoCAD SHX Text
BY
AutoCAD SHX Text
DATE
AutoCAD SHX Text
REVISIONS
AutoCAD SHX Text
REVISION
AutoCAD SHX Text
NUMBER
AutoCAD SHX Text
PROJECT INFORMATION
AutoCAD SHX Text Chapman
AutoCAD SHX Text Technical
AutoCAD SHX Text Group
AutoCAD SHX Text www.chaptech.com
AutoCAD SHX Text
KMK
AutoCAD SHX Text
KMK
AutoCAD SHX Text
STAFF
AutoCAD SHX Text
AUGUST 4, 2020
AutoCAD SHX Text 1/4"=1'-0"
AutoCAD SHX Text 20024
AutoCAD SHX Text
AutoCAD SHX Text
DIVISION OF NATURAL RESOURCES
AutoCAD SHX Text
WILDLIFE RESOURCES SECTION
AutoCAD SHX Text
WHITE HORSE WILDLIFE MANAGEMENT AREA
AIRPORT PLANNING / DEVELOPMENT
ARCHITECTURE / INTERIOR DESIGN
CIVIL ENGINEERING / SITE DEVELOPMENT
ENVIRONMENTAL ENGINEERING
LANDSCAPE ARCHITECTURE
SURVEYING
St. Albans, WV
(304) 727-5501
Buckhannon, WV
(304) 472-8914 a division of
GRW
AutoCAD SHX Text
PART 1 - GENERAL
AutoCAD SHX Text
I. DESCRIPTION OF THE WORK
AutoCAD SHX Text
A. THE EXTENT OF THE PLUMBING WORK IS INDICATED ON THE DRAWINGS.
AutoCAD SHX Text
II. CODES
AutoCAD SHX Text
A. ALL EQUIPMENT AND THE ENTIRE INSTALLATION SHALL BE IN ACCORDANCE
AutoCAD SHX Text
WITH THE APPLICABLE PROVISIONS OF THE CURRENT EDITION OF THE
AutoCAD SHX Text
INTERNATIONAL PLUMBING CODE, O.S.H.A. REQUIREMENTS, LIFE SAFETY CODE
AutoCAD SHX Text
AND ALL APPLICABLE LOCAL AND STATE LAWS AND ORDINANCES.
AutoCAD SHX Text
B. THE CONTRACTOR SHALL PAY ALL INSPECTION FEES AND PURCHASE ALL
AutoCAD SHX Text
PERMITS REQUIRED FOR THIS WORK.
AutoCAD SHX Text
III. LOCATION OF EQUIPMENT
AutoCAD SHX Text
A. THE CONTRACTOR SHALL NOTE THAT THE PLUMBING DRAWINGS ARE INTENDED
AutoCAD SHX Text
TO INDICATE ONLY THE EXTENT DIAGRAMMATICALLY, GENERAL CHARACTER AND
AutoCAD SHX Text
LOCATION OF THE WORK. WORK INTENDED, BUT HAVING MINOR DETAILS
AutoCAD SHX Text
OBVIOUSLY OMITTED, SHALL BE FURNISHED AND INSTALLED COMPLETE BY THIS
AutoCAD SHX Text
CONTRACTOR AT HIS EXPENSE.
AutoCAD SHX Text
IV. ROUGH-IN
AutoCAD SHX Text
A. VERIFY FINAL LOCATIONS FOR ROUGH-INS WITH SHOP DRAWINGS, FIELD
AutoCAD SHX Text
MEASUREMENTS AND WITH THE REQUIREMENTS OF THE ACTUAL EQUIPMENT TO
AutoCAD SHX Text
BE CONNECTED PRIOR TO ROUGH-IN.
AutoCAD SHX Text
B. OBTAIN FROM OWNER AND GENERAL CONTRACTOR COPIES OF "EQUIPMENT
AutoCAD SHX Text
BROCHURE" AND A SET OF SHOP DRAWINGS OF EQUIPMENT BEFORE
AutoCAD SHX Text
ROUGHING IN ANY WATER, WASTE, CONNECTIONS, ETC. CHANGES RESULTING
AutoCAD SHX Text
FROM FAILURE TO OBTAIN THIS INFORMATION WILL NOT RESULT IN ADDITIONAL
AutoCAD SHX Text
COST.
AutoCAD SHX Text
V. WARRANTIES
AutoCAD SHX Text
A. GUARANTEE ALL PLUMBING SYSTEM MATERIALS AND WORKMANSHIP TO BE
AutoCAD SHX Text
FREE FROM DEFECTS FOR A PERIOD OF ONE (1) YEAR FROM THE DATE OF FINAL
AutoCAD SHX Text
ACCEPTANCE AND PROPERLY CORRECT LATENT DEFECTS ARISING WITHIN THIS
AutoCAD SHX Text
PERIOD UPON NOTIFICATION BY THE OWNER'S REPRESENTATIVE WITHOUT
AutoCAD SHX Text
ADDITIONAL COMPENSATION.
AutoCAD SHX Text
VI. CHANGES
AutoCAD SHX Text
A. THE DRAWINGS INDICATE GENERALLY THE LOCATIONS OF PLUMBING FIXTURES,
AutoCAD SHX Text
APPARATUS, PIPING, ETC., BUT IF, BEFORE INSTALLATION, IT IS FOUND NECESSARY
AutoCAD SHX Text
TO CHANGE THE LOCATION OF SAME TO ACCOMMODATE THE CONDITIONS AT THE
AutoCAD SHX Text
BUILDING, SUCH CHANGES SHALL BE MADE WITHOUT ADDITIONAL COST TO THE
AutoCAD SHX Text
OWNER AND AS DIRECTED BY THE OWNER.
AutoCAD SHX Text
VII. PLUMBING SUBMITTALS:
AutoCAD SHX Text
A. SUBMITTALS ARE REQUIRED ON THE FOLLOWING ITEMS AND THEY MAY BE
AutoCAD SHX Text
SELECTED FROM ONE OF THE MANUFACTURERS LISTED OR APPROVED EQUAL:
AutoCAD SHX Text
1. PLUMBING FIXTURES
AutoCAD SHX Text
a. AMERICAN STANDARD
AutoCAD SHX Text
b. KOHLER
AutoCAD SHX Text
2. FLOOR DRAINS & SPECIALTIES
AutoCAD SHX Text
a. ZURN
AutoCAD SHX Text
b. J.R. SMITH
AutoCAD SHX Text
VIII. AS BUILT DRAWINGS
AutoCAD SHX Text
A. FURNISH THE OWNER THREE (3) SETS OF AS-BUILT DRAWINGS UPON
AutoCAD SHX Text
COMPLETION OF THE WORK.
AutoCAD SHX Text
PART 2 - PRODUCTS
AutoCAD SHX Text
I. PIPING
AutoCAD SHX Text
A. INTERIOR SANITARY AND STORM SYSTEMS SHALL BE SCH. 40 PVC PIPE AND
AutoCAD SHX Text
FITTINGS. CAST IRON NO-HUB SHALL BE USED ABOVE SLAB WHERE ABOVE
AutoCAD SHX Text
B. INTERIOR HOT AND COLD WATER PIPE ABOVE CEILING SHALL BE TYPE "L" HARD
AutoCAD SHX Text
DRAWN COPPER WITH WROUGHT COPPER FITTINGS, LEAD FREE SOLDER JOINTS.
AutoCAD SHX Text
C. EXPOSED PIPE IN RESTROOMS SHALL BE CHROME PLATED BRASS WITH
AutoCAD SHX Text
CHROME PLATED WALL PLATES, AMERICAN BRASS CO. OR EQUIVALENT.
AutoCAD SHX Text
II. CLEANOUTS
AutoCAD SHX Text
A. FLOOR CLEANOUTS SHALL HAVE CAST IRON BODY, NICKEL BRONZE SCORIATED
AutoCAD SHX Text
TOP AND RUBBER GASKETED CONNECTION.
AutoCAD SHX Text
III. VALVES
AutoCAD SHX Text
A. INTERIOR: BALL VALVES SHALL BE 125 POUND, SCREWED, ALL BRONZE, TWO
AutoCAD SHX Text
PIECE, FULL PORT DESIGN. NIBCO T-580 OR EQUIVALENT.
AutoCAD SHX Text
IV. STOP VALVES
AutoCAD SHX Text
A. CROME PLATED MACHINED FROM SOILD BRASS, 1/4 TURN BALL TYPE
AutoCAD SHX Text
OPERATION, PTFE SEATS. COMPLIES WITH ASME A112.18.6. EQUAL TO
AutoCAD SHX Text
B. SINKS AND LAVATORIES SHALL HAVE CHROME PLATED COPPER P-TRAPS 17
AutoCAD SHX Text
GA. MIN.
AutoCAD SHX Text
VII. ESCUTCHEON PLATES
AutoCAD SHX Text
A. CHROME PLATED ESCUTCHEON PLATES FOR ALL EXPOSED PIPE PASSING
AutoCAD SHX Text
THROUGH WALLS, FLOORS OR CEILINGS.
AutoCAD SHX Text
VIII. PIPE INSULATION
AutoCAD SHX Text
A. INSULATE HOT AND COLD WATER PIPING WITH 1" THICK FLEXIBLE
AutoCAD SHX Text
ELECTROMETRIC CELLULAR PIPE INSULATION. SELF SEALING JACKET.
AutoCAD SHX Text
PART 3 - EXECUTION
AutoCAD SHX Text
I. INSTALLATION OF PIPING
AutoCAD SHX Text
A. ON VERTICAL SANITARY DRAIN LINES, CONNECT ALL SOIL AND WASTE INLETS
AutoCAD SHX Text
THROUGH SANITARY TEES, WYES, OR WYES AND EIGHT BENDS. SHORT RADIUS
AutoCAD SHX Text
FITTINGS MAY BE USED FOR VENT PIPING. ON HORIZONTAL LINES, CONNECT ALL
AutoCAD SHX Text
WASTE AND SOIL CONNECTIONS THROUGH WYES, OR WYES AND EIGHT BENDS.
AutoCAD SHX Text
DOUBLE BRANCH FITTINGS MAY BE USED ON VERTICAL LINES AND HORIZONTAL
AutoCAD SHX Text
RUNS PROVIDING PROPER GRADES CAN BE MAINTAINED.
AutoCAD SHX Text
B. MAKE SCREW JOINTS BETWEEN THREADED CONNECTIONS AND OTHER PIPES
AutoCAD SHX Text
WATER-TIGHT WITH APPROVED COMPOUND.
AutoCAD SHX Text
C. PITCH HORIZONTAL DRAINS 1/8" PER FOOT MINIMUM, OR AS PER LOCAL
AutoCAD SHX Text
CODE.
AutoCAD SHX Text
D. PROVIDE CLEANOUTS AT EVERY CHANGE IN DIRECTION OF MORE THAN
AutoCAD SHX Text
FORTY-FIVE DEGREES AND EVERY HUNDRED FEET AS REQUIRED BY LOCAL CODES.
AutoCAD SHX Text
E. CUT BRASS AND COPPER PIPE BY MEANS OF A TUBING CUTTER. REMOVE
AutoCAD SHX Text
ALL BURRS AND METAL CHIPS, DIRT, ETC., BEFORE JOINING PIPE. CHROME
AutoCAD SHX Text
PLATED PIPE SHALL SHOW NO WRENCH MARKS AFTER INSTALLATION; NO THREADS
AutoCAD SHX Text
SHALL SHOW.
AutoCAD SHX Text
F. ADEQUATELY SUPPORT ALL PIPING ABOVE FLOORS, INSIDE THE BUILDING
AutoCAD SHX Text
FROM OR ON THE BUILDING STRUCTURE. SUPPORT PIPING SUSPENDED FROM
AutoCAD SHX Text
THE BUILDING STRUCTURE BY MEANS OF THE SPECIFIED PIPE HANGERS AND
AutoCAD SHX Text
RODS. MAKE MAXIMUM SPACING BETWEEN PIPE SUPPORTS AS FOLLOWS:
AutoCAD SHX Text
COPER AND STEEL MAXIMUM SPAN
AutoCAD SHX Text
3/4" & UNDER 5'
AutoCAD SHX Text 1" 7'
AutoCAD SHX Text 1-1/4" 7'
AutoCAD SHX Text 1-1/2" 9'
AutoCAD SHX Text 2" 10'
AutoCAD SHX Text
II. INSTALLATION OF VALVES
AutoCAD SHX Text
A. ISOLATE ALL MAJOR PIPING ASSEMBLIES AS SHOWN ON THE DRAWINGS AND
AutoCAD SHX Text
AS REQUIRED FOR PROPER OPERATION AND MAINTENANCE. ALL VALVES SHALL
AutoCAD SHX Text
BE ACCESSIBLE. PROVIDE VALVE BOXES AND ACCESS PANELS WHERE REQUIRED
AutoCAD SHX Text
FOR ACCESSIBILITY.
AutoCAD SHX Text
III. INSTALLATION OF TRAPS
AutoCAD SHX Text
A. TRAP EACH FIXTURE BY WATER SEALING TRAP PLACED AS NEAR THE FIXTURE
AutoCAD SHX Text
AS POSSIBLE.
AutoCAD SHX Text
B. VENT ALL TRAPS AS PER LOCAL PLUMBING CODE REQUIREMENTS.
AutoCAD SHX Text
IV. INSTALLATION OF PIPE SLEEVES
AutoCAD SHX Text
A. INSTALL PIPE SLEEVES AT ALL LOCATIONS WHERE PIPE PASSES THROUGH
AutoCAD SHX Text
WALLS, FLOORS, OR CEILINGS.
AutoCAD SHX Text
V. INSTALLATION OF AIR CHAMBERS
AutoCAD SHX Text
A. INSTALL A WATER HAMMER ARRESTOR AT EACH FIXTURE, OR GROUP OF
AutoCAD SHX Text
FIXTURES. WATER HAMMER ARRESTERS, SHALL BE ZURN SHOKTROL SIZED AND
AutoCAD SHX Text
INSTALLED PER MANUFACTURER'S RECOMMENDATION.
AutoCAD SHX Text
VI. INSTALLATION OF FIXTURE TRIM AND FITTINGS
AutoCAD SHX Text
A. INSTALL THE FIXTURE TRIM AND FITTINGS SPECIFIED, TAKING CARE TO
AutoCAD SHX Text
PROPERLY ANCHOR EACH FIXTURE.
AutoCAD SHX Text
B. WHEN THE USE OF A WRENCH IS NECESSARY ON CHROMIUM PLATED PIPING
AutoCAD SHX Text
PROTECT THE PIPE FROM MARRING BY USE OF FELT OR CLOTH WRAPPING
AutoCAD SHX Text
BENEATH WRENCH JAWS.
AutoCAD SHX Text
VII. INSTALLATION OF PIPE INSULATION
AutoCAD SHX Text
A. INSULATE ALL DOMESTIC HOT AND COLD WATER PIPING.
AutoCAD SHX Text
VIII. TESTS AND INSPECTIONS
AutoCAD SHX Text
A. MAKE ALL WATER AND PROPANE TESTS OF THE PIPING SYSTEMS IN THE
AutoCAD SHX Text
PRESENCE OF AND TO THE SATISFACTION OF THE OWNER OR HIS DESIGNATED
AutoCAD SHX Text
REPRESENTATIVE, AND LOCAL OFFICIALS. CONDUCT THESE TESTS AT SUCH
AutoCAD SHX Text
PLACES AND WITH TIMING TO PERMIT WORK TO PROCEED WITH AS LITTLE
AutoCAD SHX Text
INTERRUPTION AS POSSIBLE. MAKE TEST BEFORE WORK IS CONCEALED.
AutoCAD SHX Text
B. TEST WATER PIPING TO HYDROSTATIC PRESSURE OF 150 PSI AND HOLD FOR
AutoCAD SHX Text
4 HOURS WITH LESS THAN 2 PSI LOSS IN PRESSURE.
AutoCAD SHX Text
D. AFTER THE INSTALLATION OF SANITARY PIPING AND BEFORE THE PIPE IS
AutoCAD SHX Text
CONCEALED OR THE FIXTURES ARE INSTALLED, CAP OR PLUG THE ENDS OF THE
AutoCAD SHX Text
SYSTEM AND FILL ALL LINES WITH WATER TO TOP OF VENTS (BUT NOT LESS THAN
AutoCAD SHX Text
10' OF HEAD), ALLOW TO STAND UNTIL A THOROUGH INSPECTION HAS BEEN
AutoCAD SHX Text
MADE. SHOULD LEAKS APPEAR, MAKE NECESSARY CORRECTIONS AND REPEAT
AutoCAD SHX Text
THE TESTS UNTIL THE SYSTEM IS TIGHT.
AutoCAD SHX Text
E. DO NOT USE RESIN, CANDLE WAX, OR ANY OTHER SUCH SUBSTANCE FOR
AutoCAD SHX Text
STOPPING LEAKS IN CAST IRON SOIL, WASTE OR VENT LINES. CAULKING OF
AutoCAD SHX Text
SCREW JOINTS TO STOP LEAKS WILL NOT BE PERMITTED.
AutoCAD SHX Text
F. LABEL ALL VALVES IN EQUIPMENT ROOM AS TO SERVICE AND FUNCTION WITH
AutoCAD SHX Text
BRASS TAGS. PLACE ON VALVES WITH STEEL RINGS. LABEL COLD WATER
AutoCAD SHX Text
PIPING, HOT WATER PIPING AND HOT WATER RETURN PIPING WITH PIPE MARKERS.
AutoCAD SHX Text
VALVE LABELS AND PIPE MARKERS SHALL BE SETON NAME PLATE CO.
AutoCAD SHX Text
IX. STERILIZATION
AutoCAD SHX Text
A. THE STERILIZATION PROCESS SHALL COMPLY WITH ALL GOVERNING
AutoCAD SHX Text
REGULATIONS AND WITH THE STERILIZATION PROCEDURES RECOMMENDED BY THE
AutoCAD SHX Text
AMERICAN WATER WORKS ASSOCIATION. THE CHLORINATION PROCESS MAY BE
AutoCAD SHX Text
SIMPLIFIED BY FIRST FLUSHING THE SYSTEM THOROUGHLY CLEAN, THEN CHARGING
AutoCAD SHX Text
WITH WATER CONTAINING A MINIMUM OF 50 PARTS PER MILLION OF CHLORINE,
AutoCAD SHX Text
ALLOWING THIS TO STAND FOR 24 HOURS, THEN THOROUGHLY FLUSHING. AFTER
AutoCAD SHX Text
STERILIZATION AND FINAL FLUSHING, THE LOCAL HEALTH AUTHORITY IS TO BE
AutoCAD SHX Text
NOTIFIED, AND THEIR FINAL APPROVAL OBTAINED IN WRITING.
AutoCAD SHX Text
END OF SECTION 15400
AutoCAD SHX Text
PVC PIPE SIZE MAXIMUM SPAN
AutoCAD SHX Text 1 1/2" 4'
AutoCAD SHX Text 2" 4'
AutoCAD SHX Text
PIPE SIZE
AutoCAD SHX Text
c. ZURN
AutoCAD SHX Text
d. JUST
AutoCAD SHX Text
e. ELKAY
AutoCAD SHX Text
f. EL MUSTEE
AutoCAD SHX Text
c. WATTS
AutoCAD SHX Text
d. GUY GRAY
AutoCAD SHX Text
CEILING SPACE IS USED FOR PLENUM RETURN OR PIPING SHALL BE INSULATED
AutoCAD SHX Text
TO MEET 25/50 SMOKE AND FLAME SPREAD RATING.
AutoCAD SHX Text 3" 4'
AutoCAD SHX Text 4" 4'
AutoCAD SHX Text
G. INSTALL…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .