Base Period
ATTACHMENT 2 - SCHEDULE OF SERVICES
Solicitation W91QVN-17-R-0091 Telecommunications Infrastructure Support Services (TISS), USFK-Wide
| Base Period: 1 September 2017 - 31 August 2018 | |||||
| CLIN | CLIN | ||||
| TYPE | SERVICES DESCRIPTION | Qty | Unit | Unit Price | Amount |
| 0001 | FFP | COPPER CABLE | |||
| Install, Splice, Terminate, and Test - Copper Cable (25 to 1200 PR). | 40,000 | FT |
(Linear Foot)
| 0002 | FFP | GROUND ROD | |
| Install Ground Rod to Include Grounding of Cable / Terminal. | 100 | EA | |
| 0003 | FFP | PET HOUSING | |
| Install Protected Entrance Terminal (PET) Housing for Copper Cable. | 50 | EA | |
| 0004 | FFP | SPLICE CASE FOR COPPER CABLE | |
| Install Splice Case for Copper Cable. | 50 | EA | |
| 0005 | FFP | ¾ INCH, FIRE-RETARDANT PLYWOOD BACKBOARD | |
| Provide Contractor Furnished Material (CFM) and Install ¾ Inch, Fire-Retardant Plywood Backboard. | 40 | EA | |
| 0006 | FFP | FIBER OPTIC CABLE IN DUCT | |
| Install, Terminate, Splice, and Test - Fiber Optic Cable in Duct (2 to 144 Fiber Cores). | 160,000 | FT |
(Linear Foot)
| 0007 | FFP | LEAF FIBER OPTIC CABLE IN DUCT | |
| Install, Terminate, Splice, and Test - LEAF Fiber Optic Cable in Duct (12 to 96 Fiber Cores). | 800,000 | FT |
(Linear Foot)
| 0008 | FFP | TERMINATION PANEL | |
| Install Fiber Optic - Termination Panel (Wall Mount or Rack). | 100 | EA | |
| 0009 | FFP | SPLICE ENCLOSURE KIT | |
| Install Fiber Optic Cable - Splice Enclosure Kit (12 to 144 Cores). | 100 | EA | |
| 0010 | FFP | ENCASED BURIED (EB)-20 CONDUIT |
Provide Contractor Furnished Material (CFM) and Install 4 Inch (1 to 4 Ducts) Encased Buried (EB)-20 Conduit Where Vehicular Traffic (i.e., Automotive, Railway) is Present.
Duct Installation to Include Excavation, Backfill, Restoration of Paved and Concrete Surfaces, Concrete Encasing, Spacers, Markers and Warning Tape(Paved Area). 5,000 FT (Linear Foot)
0011 FFP RIGID NONMETALLIC CONDUIT
Provide Contractor Furnished Material (CFM) and Install 4 Inch (1 to 4 Ducts) Rigid Nonmetallic Conduit Schedule 40 PVC Conduit.
Duct Installation to Include Excavation, Backfill, Markers and Warning Tape. 20,000 FT (Linear Foot)
| 0012 | FFP | SUB / MULTI / MESH INNERDUCT | |
| Install Sub-Duct / Innerduct / Multi-Duct / Fabric-Mesh Innerduct. | 10,000 | FT |
(Linear Foot)
| 0013 | FFP | CORE DRILL ½ TO 4 INCH HOLE | |
| Core Drill ½ to 4 Inch Hole. | 1,000 | EA | |
| 0014 | FFP | 2 INCH TO 4 INCH BUILDING ENTRANCE CONDUIT | |
| Provide Contractor Furnished Material (CFM) and Install 2 to 4 Inch Building Entrance Conduit. | 50 | EA | |
| 0015 | FFP | MULTIDIRECTIONAL HANDHOLE | |
| Provide Contractor Furnished Material (CFM) and Install Multidirectional 1220 x 1220 x 1220 Milimeter Handhole to Include Excavation, Restoration, Backfill, Plugging Ducts, All Hardware and Grounding Installation. | 25 | EA | |
| 0016 | FFP | MULTIDIRECTIONAL MAINTENANCE HOLE | |
| Provide Contractor Furnished Material (CFM) and Install Multidirectional W1850mm by L3700 x H2150 Milimeter Maintenance Hole to Include Excavation, Restoration, Backfill, Plugging Ducts, All Hardware and Grounding Installation. | 5 | EA | |
| 0017 | FFP | CAT 6 LAN CABLE | |
| Install, Terminate, and Test CAT 6 LAN Cable. | 500,000 | FT |
(Linear Foot)
| 0018 | FFP | CAT 6 WALL OUTLET BOX | |
| Install CAT 6 Wall Outlet Box. | 500 | EA | |
| 0019 | FFP | NON-METALLIC RACEWAY | |
| Install of Non-Metallic Raceway. | 30,000 | FT |
(Linear Foot)
| 0020 | FFP | 6 TO 12 INCH METAL CABLE LADDER RACK | |
| Install and Bonding of 6 to 12 Inch Metal Cable Ladder Rack. | 10 | FT |
(Linear Foot)
| 0021 | FFP | EQUIPMENT RACK | |
| Install Equipment Rack. | 10 | EA | |
| 0022 | FFP | STRAND AND GUY WIRES FOR AERIAL CABLE | |
| Provide Contractor Furnished Material (CFM) and Install Strand and Guy Wires for Aerial Cable. | 50,000 | FT |
(Linear Foot)
| 0023 | FFP | CABLE ON STRAND USING LASHING MACHINE | |
| Install Cable on Strand Using Lashing Machine to Include Splicing, Termination, and Testing of Cable. | 65,000 | FT |
(Linear Foot)
| 0024 | FFP | SPLICE CASE ON STRAND | |
| Install Splice Case on Strand. | 20 | EA | |
| 0025 | FFP | ½ TO 2 INCH EMT CONDUIT INSIDE | |
| Installation of ½ to 2 Inch Electrical Metallic Tubing (EMT) Conduit Inside of Building. | 35,000 | FT |
(Linear Foot)
| 0026 | FFP | PULL OR DROP BOX FOR PDS | |
| Install Pull or Drop Box for Protected Distribution System (PDS). | 10 | EA | |
| 0027 | FFP | GIP 4 INCH CONDUIT WITH COUPLINGS INSIDE | |
| Provide Contractor Furnished Material (CFM) and Install Galvanized (GIP) 4 Inch Conduit with Couplings Inside of Building. | 100 | FT |
(Linear Foot)
| 0028 | FFP | GIP 4 INCH CONDUIT WITH COUPLINGS BURIED | |
| Provide Contractor Furnished Material (CFM) and Install Galvanized (GIP) 4 Inch Conduit with Couplings Buried at a Minimum of 1 Meter Below the Surface, Encased Within a Minimum of 20 Centimeters of Concrete On All Sides. | 200 | FT |
(Linear Foot)
| 0029 | FFP | DEINSTALL CABLE IN CONDUITS | |
| Deinstall Cable in Conduits. | 1,000,000 | FT |
(Linear Foot)
| 0030 | FFP | CIS TYPE 25 MILIMETER X 4 EACH | |
| Provide Contractor Furnished Material (CFM) and Install Combined Innerduct System (CIS) Type 25 Milimeter x 4 Each (Black, Yellow, Red, Green). | 6,000 | FT |
(Linear Foot)
| 0031 | FFP | OUTSIDE PULL-BOX | |
| Install Outside Pull-Box (Various Sizes). | 40 | EA | |
| 0032 | FFP | PULLING WIRE IN DUCTS | |
| Provide Contractor Furnished Material (CFM) and Install Pulling Wire in Ducts. | 1,000,000 | FT |
(Linear Foot)
| 0033 | FFP | ACCOUNTING FOR CONTRACT SERVICES | |
| Contractor Manpower Reporting (CMR) Must be Reported by 31 October of Each Calendar Year During the Life of the Contract. | 1 | JOB | |
| 0034 | INFO | ESTIMATED COST FOR WAR HAZARD LOSSES |
Estimated Cost for War Hazard Losses is Zero ($0.00).
Total Amount for Base Period
1st Option Period
ATTACHMENT 2 - SCHEDULE OF SERVICES
Solicitation W91QVN-17-R-0091 Telecommunications Infrastructure Support Services (TISS), USFK-Wide
| 1st Option Period: 1 September 2018 - 31 August 2019 | |||||
| CLIN | CLIN | ||||
| TYPE | SERVICES DESCRIPTION | Qty | Unit | Unit Price | Amount |
| 1001 | FFP | COPPER CABLE | |||
| Install, Splice, Terminate, and Test - Copper Cable (25 to 1200 PR). | 40,000 | FT |
(Linear Foot)
| 1002 | FFP | GROUND ROD | |
| Install Ground Rod to Include Grounding of Cable / Terminal. | 100 | EA | |
| 1003 | FFP | PET HOUSING | |
| Install Protected Entrance Terminal (PET) Housing for Copper Cable. | 50 | EA | |
| 1004 | FFP | SPLICE CASE FOR COPPER CABLE | |
| Install Splice Case for Copper Cable. | 50 | EA | |
| 1005 | FFP | ¾ INCH, FIRE-RETARDANT PLYWOOD BACKBOARD | |
| Provide Contractor Furnished Material (CFM) and Install ¾ Inch, Fire-Retardant Plywood Backboard. | 40 | EA | |
| 1006 | FFP | FIBER OPTIC CABLE IN DUCT | |
| Install, Terminate, Splice, and Test - Fiber Optic Cable in Duct (2 to 144 Fiber Cores). | 160,000 | FT |
(Linear Foot)
| 1007 | FFP | LEAF FIBER OPTIC CABLE IN DUCT | |
| Install, Terminate, Splice, and Test - LEAF Fiber Optic Cable in Duct (12 to 96 Fiber Cores). | 800,000 | FT |
(Linear Foot)
| 1008 | FFP | TERMINATION PANEL | |
| Install Fiber Optic - Termination Panel (Wall Mount or Rack). | 100 | EA | |
| 1009 | FFP | SPLICE ENCLOSURE KIT | |
| Install Fiber Optic Cable - Splice Enclosure Kit (12 to 144 Cores). | 100 | EA | |
| 1010 | FFP | ENCASED BURIED (EB)-20 CONDUIT |
Provide Contractor Furnished Material (CFM) and Install 4 Inch (1 to 4 Ducts) Encased Buried (EB)-20 Conduit Where Vehicular Traffic (i.e., Automotive, Railway) is Present.
Duct Installation to Include Excavation, Backfill, Restoration of Paved and Concrete Surfaces, Concrete Encasing, Spacers, Markers and Warning Tape(Paved Area). 5,000 FT (Linear Foot)
1011 FFP RIGID NONMETALLIC CONDUIT
Provide Contractor Furnished Material (CFM) and Install 4 Inch (1 to 4 Ducts) Rigid Nonmetallic Conduit Schedule 40 PVC Conduit.
Duct Installation to Include Excavation, Backfill, Markers and Warning Tape. 20,000 FT (Linear Foot)
| 1012 | FFP | SUB / MULTI / MESH INNERDUCT | |
| Install Sub-Duct / Innerduct / Multi-Duct / Fabric-Mesh Innerduct. | 10,000 | FT |
(Linear Foot)
| 1013 | FFP | CORE DRILL ½ TO 4 INCH HOLE | |
| Core Drill ½ to 4 Inch Hole. | 1,000 | EA | |
| 1014 | FFP | 2 INCH TO 4 INCH BUILDING ENTRANCE CONDUIT | |
| Provide Contractor Furnished Material (CFM) and Install 2 to 4 Inch Building Entrance Conduit. | 50 | EA | |
| 1015 | FFP | MULTIDIRECTIONAL HANDHOLE | |
| Provide Contractor Furnished Material (CFM) and Install Multidirectional 1220 x 1220 x 1220 Milimeter Handhole to Include Excavation, Restoration, Backfill, Plugging Ducts, All Hardware and Grounding Installation. | 25 | EA | |
| 1016 | FFP | MULTIDIRECTIONAL MAINTENANCE HOLE | |
| Provide Contractor Furnished Material (CFM) and Install Multidirectional W1850mm by L3700 x H2150 Milimeter Maintenance Hole to Include Excavation, Restoration, Backfill, Plugging Ducts, All Hardware and Grounding Installation. | 5 | EA | |
| 1017 | FFP | CAT 6 LAN CABLE | |
| Install, Terminate, and Test CAT 6 LAN Cable. | 400,000 | FT |
(Linear Foot)
| 1018 | FFP | CAT 6 WALL OUTLET BOX | |
| Install CAT 6 Wall Outlet Box. | 400 | EA | |
| 1019 | FFP | NON-METALLIC RACEWAY | |
| Install of Non-Metallic Raceway. | 24,000 | FT |
(Linear Foot)
| 1020 | FFP | 6 TO 12 INCH METAL CABLE LADDER RACK | |
| Install and Bonding of 6 to 12 Inch Metal Cable Ladder Rack. | 10 | FT |
(Linear Foot)
| 1021 | FFP | EQUIPMENT RACK | |
| Install Equipment Rack. | 10 | EA | |
| 1022 | FFP | STRAND AND GUY WIRES FOR AERIAL CABLE | |
| Provide Contractor Furnished Material (CFM) and Install Strand and Guy Wires for Aerial Cable. | 50,000 | FT |
(Linear Foot)
| 1023 | FFP | CABLE ON STRAND USING LASHING MACHINE | |
| Install Cable on Strand Using Lashing Machine to Include Splicing, Termination, and Testing of Cable. | 65,000 | FT |
(Linear Foot)
| 1024 | FFP | SPLICE CASE ON STRAND | |
| Install Splice Case on Strand. | 20 | EA | |
| 1025 | FFP | ½ TO 2 INCH EMT CONDUIT INSIDE | |
| Installation of ½ to 2 Inch Electrical Metallic Tubing (EMT) Conduit Inside of Building. | 30,000 | FT |
(Linear Foot)
| 1026 | FFP | PULL OR DROP BOX FOR PDS | |
| Install Pull or Drop Box for Protected Distribution System (PDS). | 10 | EA | |
| 1027 | FFP | GIP 4 INCH CONDUIT WITH COUPLINGS INSIDE | |
| Provide Contractor Furnished Material (CFM) and Install Galvanized (GIP) 4 Inch Conduit with Couplings Inside of Building. | 80 | FT |
(Linear Foot)
| 1028 | FFP | GIP 4 INCH CONDUIT WITH COUPLINGS BURIED | |
| Provide Contractor Furnished Material (CFM) and Install Galvanized (GIP) 4 Inch Conduit with Couplings Buried at a Minimum of 1 Meter Below the Surface, Encased Within a Minimum of 20 Centimeters of Concrete On All Sides. | 160 | FT |
(Linear Foot)
| 1029 | FFP | DEINSTALL CABLE IN CONDUITS | |
| Deinstall Cable in Conduits. | 800,000 | FT |
(Linear Foot)
| 1030 | FFP | CIS TYPE 25 MILIMETER X 4 EACH | |
| Provide Contractor Furnished Material (CFM) and Install Combined Innerduct System (CIS) Type 25 Milimeter x 4 Each (Black, Yellow, Red, Green). | 5,000 | FT |
(Linear Foot)
| 1031 | FFP | OUTSIDE PULL-BOX | |
| Install Outside Pull-Box (Various Sizes). | 35 | EA | |
| 1032 | FFP | PULLING WIRE IN DUCTS | |
| Provide Contractor Furnished Material (CFM) and Install Pulling Wire in Ducts. | 800,000 | FT |
(Linear Foot)
| 1033 | FFP | ACCOUNTING FOR CONTRACT SERVICES | |
| Contractor Manpower Reporting (CMR) Must be Reported by 31 October of Each Calendar Year During the Life of the Contract. | 1 | JOB | |
| 1034 | INFO | ESTIMATED COST FOR WAR HAZARD LOSSES |
Total Amount for 1st Option Period
2nd Option Period
ATTACHMENT 2 - SCHEDULE OF SERVICES
Solicitation W91QVN-17-R-0091 Telecommunications Infrastructure Support Services (TISS), USFK-Wide
| 2nd Option Period: 1 September 2019 - 31 August 2020 | |||||
| CLIN | CLIN | ||||
| TYPE | SERVICES DESCRIPTION | Qty | Unit | Unit Price | Amount |
| 2001 | FFP | COPPER CABLE | |||
| Install, Splice, Terminate, and Test - Copper Cable (25 to 1200 PR). | 40,000 | FT |
(Linear Foot)
| 2002 | FFP | GROUND ROD | |
| Install Ground Rod to Include Grounding of Cable / Terminal. | 100 | EA | |
| 2003 | FFP | PET HOUSING | |
| Install Protected Entrance Terminal (PET) Housing for Copper Cable. | 50 | EA | |
| 2004 | FFP | SPLICE CASE FOR COPPER CABLE | |
| Install Splice Case for Copper Cable. | 50 | EA | |
| 2005 | FFP | ¾ INCH, FIRE-RETARDANT PLYWOOD BACKBOARD | |
| Provide Contractor Furnished Material (CFM) and Install ¾ Inch, Fire-Retardant Plywood Backboard. | 40 | EA | |
| 2006 | FFP | FIBER OPTIC CABLE IN DUCT | |
| Install, Terminate, Splice, and Test - Fiber Optic Cable in Duct (2 to 144 Fiber Cores). | 160,000 | FT |
(Linear Foot)
| 2007 | FFP | LEAF FIBER OPTIC CABLE IN DUCT | |
| Install, Terminate, Splice, and Test - LEAF Fiber Optic Cable in Duct (12 to 96 Fiber Cores). | 800,000 | FT |
(Linear Foot)
| 2008 | FFP | TERMINATION PANEL | |
| Install Fiber Optic - Termination Panel (Wall Mount or Rack). | 100 | EA | |
| 2009 | FFP | SPLICE ENCLOSURE KIT | |
| Install Fiber Optic Cable - Splice Enclosure Kit (12 to 144 Cores). | 100 | EA | |
| 2010 | FFP | ENCASED BURIED (EB)-20 CONDUIT |
Provide Contractor Furnished Material (CFM) and Install 4 Inch (1 to 4 Ducts) Encased Buried (EB)-20 Conduit Where Vehicular Traffic (i.e., Automotive, Railway) is Present.
Duct Installation to Include Excavation, Backfill, Restoration of Paved and Concrete Surfaces, Concrete Encasing, Spacers, Markers and Warning Tape(Paved Area). 5,000 FT (Linear Foot)
2011 FFP RIGID NONMETALLIC CONDUIT
Provide Contractor Furnished Material (CFM) and Install 4 Inch (1 to 4 Ducts) Rigid Nonmetallic Conduit Schedule 40 PVC Conduit.
Duct Installation to Include Excavation, Backfill, Markers and Warning Tape. 20,000 FT (Linear Foot)
| 2012 | FFP | SUB / MULTI / MESH INNERDUCT | |
| Install Sub-Duct / Innerduct / Multi-Duct / Fabric-Mesh Innerduct. | 10,000 | FT |
(Linear Foot)
| 2013 | FFP | CORE DRILL ½ TO 4 INCH HOLE | |
| Core Drill ½ to 4 Inch Hole. | 1,000 | EA | |
| 2014 | FFP | 2 INCH TO 4 INCH BUILDING ENTRANCE CONDUIT | |
| Provide Contractor Furnished Material (CFM) and Install 2 to 4 Inch Building Entrance Conduit. | 50 | EA | |
| 2015 | FFP | MULTIDIRECTIONAL HANDHOLE | |
| Provide Contractor Furnished Material (CFM) and Install Multidirectional 1220 x 1220 x 1220 Milimeter Handhole to Include Excavation, Restoration, Backfill, Plugging Ducts, All Hardware and Grounding Installation. | 25 | EA | |
| 2016 | FFP | MULTIDIRECTIONAL MAINTENANCE HOLE | |
| Provide Contractor Furnished Material (CFM) and Install Multidirectional W1850mm by L3700 x H2150 Milimeter Maintenance Hole to Include Excavation, Restoration, Backfill, Plugging Ducts, All Hardware and Grounding Installation. | 5 | EA | |
| 2017 | FFP | CAT 6 LAN CABLE | |
| Install, Terminate, and Test CAT 6 LAN Cable. | 300,000 | FT |
(Linear Foot)
| 2018 | FFP | CAT 6 WALL OUTLET BOX | |
| Install CAT 6 Wall Outlet Box. | 300 | EA | |
| 2019 | FFP | NON-METALLIC RACEWAY | |
| Install of Non-Metallic Raceway. | 18,000 | FT |
(Linear Foot)
| 2020 | FFP | 6 TO 12 INCH METAL CABLE LADDER RACK | |
| Install and Bonding of 6 to 12 Inch Metal Cable Ladder Rack. | 10 | FT |
(Linear Foot)
| 2021 | FFP | EQUIPMENT RACK | |
| Install Equipment Rack. | 10 | EA | |
| 2022 | FFP | STRAND AND GUY WIRES FOR AERIAL CABLE | |
| Provide Contractor Furnished Material (CFM) and Install Strand and Guy Wires for Aerial Cable. | 50,000 | FT |
(Linear Foot)
| 2023 | FFP | CABLE ON STRAND USING LASHING MACHINE | |
| Install Cable on Strand Using Lashing Machine to Include Splicing, Termination, and Testing of Cable. | 65,000 | FT |
(Linear Foot)
| 2024 | FFP | SPLICE CASE ON STRAND | |
| Install Splice Case on Strand. | 20 | EA | |
| 2025 | FFP | ½ TO 2 INCH EMT CONDUIT INSIDE | |
| Installation of ½ to 2 Inch Electrical Metallic Tubing (EMT) Conduit Inside of Building. | 25,000 | FT |
(Linear Foot)
| 2026 | FFP | PULL OR DROP BOX FOR PDS | |
| Install Pull or Drop Box for Protected Distribution System (PDS). | 10 | EA | |
| 2027 | FFP | GIP 4 INCH CONDUIT WITH COUPLINGS INSIDE | |
| Provide Contractor Furnished Material (CFM) and Install Galvanized (GIP) 4 Inch Conduit with Couplings Inside of Building. | 60 | FT |
(Linear Foot)
| 2028 | FFP | GIP 4 INCH CONDUIT WITH COUPLINGS BURIED | |
| Provide Contractor Furnished Material (CFM) and Install Galvanized (GIP) 4 Inch Conduit with Couplings Buried at a Minimum of 1 Meter Below the Surface, Encased Within a Minimum of 20 Centimeters of Concrete On All Sides. | 120 | FT |
(Linear Foot)
| 2029 | FFP | DEINSTALL CABLE IN CONDUITS | |
| Deinstall Cable in Conduits. | 600,000 | FT |
(Linear Foot)
| 2030 | FFP | CIS TYPE 25 MILIMETER X 4 EACH | |
| Provide Contractor Furnished Material (CFM) and Install Combined Innerduct System (CIS) Type 25 Milimeter x 4 Each (Black, Yellow, Red, Green). | 4,000 | FT |
(Linear Foot)
| 2031 | FFP | OUTSIDE PULL-BOX | |
| Install Outside Pull-Box (Various Sizes). | 30 | EA | |
| 2032 | FFP | PULLING WIRE IN DUCTS | |
| Provide Contractor Furnished Material (CFM) and Install Pulling Wire in Ducts. | 600,000 | FT |
(Linear Foot)
| 2033 | FFP | ACCOUNTING FOR CONTRACT SERVICES | |
| Contractor Manpower Reporting (CMR) Must be Reported by 31 October of Each Calendar Year During the Life of the Contract. | 1 | JOB | |
| 2034 | INFO | ESTIMATED COST FOR WAR HAZARD LOSSES |
Total Amount for 2nd Option Period
3rd Option Period
ATTACHMENT 2 - SCHEDULE OF SERVICES
Solicitation W91QVN-17-R-0091 Telecommunications Infrastructure Support Services (TISS), USFK-Wide
| 3rd Option Period: 1 September 2020 - 31 August 2021 | |||||
| CLIN | CLIN | ||||
| TYPE | SERVICES DESCRIPTION | Qty | Unit | Unit Price | Amount |
| 3001 | FFP | COPPER CABLE | |||
| Install, Splice, Terminate, and Test - Copper Cable (25 to 1200 PR). | 40,000 | FT |
(Linear Foot)
| 3002 | FFP | GROUND ROD | |
| Install Ground Rod to Include Grounding of Cable / Terminal. | 100 | EA | |
| 3003 | FFP | PET HOUSING | |
| Install Protected Entrance Terminal (PET) Housing for Copper Cable. | 50 | EA | |
| 3004 | FFP | SPLICE CASE FOR COPPER CABLE | |
| Install Splice Case for Copper Cable. | 50 | EA | |
| 3005 | FFP | ¾ INCH, FIRE-RETARDANT PLYWOOD BACKBOARD | |
| Provide Contractor Furnished Material (CFM) and Install ¾ Inch, Fire-Retardant Plywood Backboard. | 40 | EA | |
| 3006 | FFP | FIBER OPTIC CABLE IN DUCT | |
| Install, Terminate, Splice, and Test - Fiber Optic Cable in Duct (2 to 144 Fiber Cores). | 160,000 | FT |
(Linear Foot)
| 3007 | FFP | LEAF FIBER OPTIC CABLE IN DUCT | |
| Install, Terminate, Splice, and Test - LEAF Fiber Optic Cable in Duct (12 to 96 Fiber Cores). | 800,000 | FT |
(Linear Foot)
| 3008 | FFP | TERMINATION PANEL | |
| Install Fiber Optic - Termination Panel (Wall Mount or Rack). | 100 | EA | |
| 3009 | FFP | SPLICE ENCLOSURE KIT | |
| Install Fiber Optic Cable - Splice Enclosure Kit (12 to 144 Cores). | 100 | EA | |
| 3010 | FFP | ENCASED BURIED (EB)-20 CONDUIT |
Provide Contractor Furnished Material (CFM) and Install 4 Inch (1 to 4 Ducts) Encased Buried (EB)-20 Conduit Where Vehicular Traffic (i.e., Automotive, Railway) is Present.
Duct Installation to Include Excavation, Backfill, Restoration of Paved and Concrete Surfaces, Concrete Encasing, Spacers, Markers and Warning Tape(Paved Area). 5,000 FT (Linear Foot)
3011 FFP RIGID NONMETALLIC CONDUIT
Provide Contractor Furnished Material (CFM) and Install 4 Inch (1 to 4 Ducts) Rigid Nonmetallic Conduit Schedule 40 PVC Conduit.
Duct Installation to Include Excavation, Backfill, Markers and Warning Tape. 20,000 FT (Linear Foot)
| 3012 | FFP | SUB / MULTI / MESH INNERDUCT | |
| Install Sub-Duct / Innerduct / Multi-Duct / Fabric-Mesh Innerduct. | 10,000 | FT |
(Linear Foot)
| 3013 | FFP | CORE DRILL ½ TO 4 INCH HOLE | |
| Core Drill ½ to 4 Inch Hole. | 1,000 | EA | |
| 3014 | FFP | 2 INCH TO 4 INCH BUILDING ENTRANCE CONDUIT | |
| Provide Contractor Furnished Material (CFM) and Install 2 to 4 Inch Building Entrance Conduit. | 50 | EA | |
| 3015 | FFP | MULTIDIRECTIONAL HANDHOLE | |
| Provide Contractor Furnished Material (CFM) and Install Multidirectional 1220 x 1220 x 1220 Milimeter Handhole to Include Excavation, Restoration, Backfill, Plugging Ducts, All Hardware and Grounding Installation. | 25 | EA | |
| 3016 | FFP | MULTIDIRECTIONAL MAINTENANCE HOLE | |
| Provide Contractor Furnished Material (CFM) and Install Multidirectional W1850mm by L3700 x H2150 Milimeter Maintenance Hole to Include Excavation, Restoration, Backfill, Plugging Ducts, All Hardware and Grounding Installation. | 5 | EA | |
| 3017 | FFP | CAT 6 LAN CABLE | |
| Install, Terminate, and Test CAT 6 LAN Cable. | 200,000 | FT |
(Linear Foot)
| 3018 | FFP | CAT 6 WALL OUTLET BOX | |
| Install CAT 6 Wall Outlet Box. | 200 | EA | |
| 3019 | FFP | NON-METALLIC RACEWAY | |
| Install of Non-Metallic Raceway. | 12,000 | FT |
(Linear Foot)
| 3020 | FFP | 6 TO 12 INCH METAL CABLE LADDER RACK | |
| Install and Bonding of 6 to 12 Inch Metal Cable Ladder Rack. | 10 | FT |
(Linear Foot)
| 3021 | FFP | EQUIPMENT RACK | |
| Install Equipment Rack. | 10 | EA | |
| 3022 | FFP | STRAND AND GUY WIRES FOR AERIAL CABLE | |
| Provide Contractor Furnished Material (CFM) and Install Strand and Guy Wires for Aerial Cable. | 50,000 | FT |
(Linear Foot)
| 3023 | FFP | CABLE ON STRAND USING LASHING MACHINE | |
| Install Cable on Strand Using Lashing Machine to Include Splicing, Termination, and Testing of Cable. | 65,000 | FT |
(Linear Foot)
| 3024 | FFP | SPLICE CASE ON STRAND | |
| Install Splice Case on Strand. | 20 | EA | |
| 3025 | FFP | ½ TO 2 INCH EMT CONDUIT INSIDE | |
| Installation of ½ to 2 Inch Electrical Metallic Tubing (EMT) Conduit Inside of Building. | 20,000 | FT |
(Linear Foot)
| 3026 | FFP | PULL OR DROP BOX FOR PDS | |
| Install Pull or Drop Box for Protected Distribution System (PDS). | 10 | EA | |
| 3027 | FFP | GIP 4 INCH CONDUIT WITH COUPLINGS INSIDE | |
| Provide Contractor Furnished Material (CFM) and Install Galvanized (GIP) 4 Inch Conduit with Couplings Inside of Building. | 40 | FT |
(Linear Foot)
| 3028 | FFP | GIP 4 INCH CONDUIT WITH COUPLINGS BURIED | |
| Provide Contractor Furnished Material (CFM) and Install Galvanized (GIP) 4 Inch Conduit with Couplings Buried at a Minimum of 1 Meter Below the Surface, Encased Within a Minimum of 20 Centimeters of Concrete On All Sides. | 80 | FT |
(Linear Foot)
| 3029 | FFP | DEINSTALL CABLE IN CONDUITS | |
| Deinstall Cable in Conduits. | 400,000 | FT |
(Linear Foot)
| 3030 | FFP | CIS TYPE 25 MILIMETER X 4 EACH | |
| Provide Contractor Furnished Material (CFM) and Install Combined Innerduct System (CIS) Type 25 Milimeter x 4 Each (Black, Yellow, Red, Green). | 3,000 | FT |
(Linear Foot)
| 3031 | FFP | OUTSIDE PULL-BOX | |
| Install Outside Pull-Box (Various Sizes). | 25 | EA | |
| 3032 | FFP | PULLING WIRE IN DUCTS | |
| Provide Contractor Furnished Material (CFM) and Install Pulling Wire in Ducts. | 400,000 | FT |
(Linear Foot)
| 3033 | FFP | ACCOUNTING FOR CONTRACT SERVICES | |
| Contractor Manpower Reporting (CMR) Must be Reported by 31 October of Each Calendar Year During the Life of the Contract. | 1 | JOB | |
| 3034 | INFO | ESTIMATED COST FOR WAR HAZARD LOSSES |
Total Amount for 3rd Option Period
4th Option Period
ATTACHMENT 2 - SCHEDULE OF SERVICES
Solicitation W91QVN-17-R-0091 Telecommunications Infrastructure Support Services (TISS), USFK-Wide
| 4th Option Period: 1 September 2021 - 31 August 2022 | |||||
| CLIN | CLIN | ||||
| TYPE | SERVICES DESCRIPTION | Qty | Unit | Unit Price | Amount |
| 4001 | FFP | COPPER CABLE | |||
| Install, Splice, Terminate, and Test - Copper Cable (25 to 1200 PR). | 40,000 | FT |
(Linear Foot)
| 4002 | FFP | GROUND ROD | |
| Install Ground Rod to Include Grounding of Cable / Terminal. | 100 | EA | |
| 4003 | FFP | PET HOUSING | |
| Install Protected Entrance Terminal (PET) Housing for Copper Cable. | 50 | EA | |
| 4004 | FFP | SPLICE CASE FOR COPPER CABLE | |
| Install Splice Case for Copper Cable. | 50 | EA | |
| 4005 | FFP | ¾ INCH, FIRE-RETARDANT PLYWOOD BACKBOARD | |
| Provide Contractor Furnished Material (CFM) and Install ¾ Inch, Fire-Retardant Plywood Backboard. | 40 | EA | |
| 4006 | FFP | FIBER OPTIC CABLE IN DUCT | |
| Install, Terminate, Splice, and Test - Fiber Optic Cable in Duct (2 to 144 Fiber Cores). | 160,000 | FT |
(Linear Foot)
| 4007 | FFP | LEAF FIBER OPTIC CABLE IN DUCT | |
| Install, Terminate, Splice, and Test - LEAF Fiber Optic Cable in Duct (12 to 96 Fiber Cores). | 800,000 | FT |
(Linear Foot)
| 4008 | FFP | TERMINATION PANEL | |
| Install Fiber Optic - Termination Panel (Wall Mount or Rack). | 100 | EA | |
| 4009 | FFP | SPLICE ENCLOSURE KIT | |
| Install Fiber Optic Cable - Splice Enclosure Kit (12 to 144 Cores). | 100 | EA | |
| 4010 | FFP | ENCASED BURIED (EB)-20 CONDUIT |
Provide Contractor Furnished Material (CFM) and Install 4 Inch (1 to 4 Ducts) Encased Buried (EB)-20 Conduit Where Vehicular Traffic (i.e., Automotive, Railway) is Present.
Duct Installation to Include Excavation, Backfill, Restoration of Paved and Concrete Surfaces, Concrete Encasing, Spacers, Markers and Warning Tape(Paved Area). 5,000 FT (Linear Foot)
4011 FFP RIGID NONMETALLIC CONDUIT
Provide Contractor Furnished Material (CFM) and Install 4 Inch (1 to 4 Ducts) Rigid Nonmetallic Conduit Schedule 40 PVC Conduit.
Duct Installation to Include Excavation, Backfill, Markers and Warning Tape. 20,000 FT (Linear Foot)
| 4012 | FFP | SUB / MULTI / MESH INNERDUCT | |
| Install Sub-Duct / Innerduct / Multi-Duct / Fabric-Mesh Innerduct. | 10,000 | FT |
(Linear Foot)
| 4013 | FFP | CORE DRILL ½ TO 4 INCH HOLE | |
| Core Drill ½ to 4 Inch Hole. | 1,000 | EA | |
| 4014 | FFP | 2 INCH TO 4 INCH BUILDING ENTRANCE CONDUIT | |
| Provide Contractor Furnished Material (CFM) and Install 2 to 4 Inch Building Entrance Conduit. | 50 | EA | |
| 4015 | FFP | MULTIDIRECTIONAL HANDHOLE | |
| Provide Contractor Furnished Material (CFM) and Install Multidirectional 1220 x 1220 x 1220 Milimeter Handhole to Include Excavation, Restoration, Backfill, Plugging Ducts, All Hardware and Grounding Installation. | 25 | EA | |
| 4016 | FFP | MULTIDIRECTIONAL MAINTENANCE HOLE | |
| Provide Contractor Furnished Material (CFM) and Install Multidirectional W1850mm by L3700 x H2150 Milimeter Maintenance Hole to Include Excavation, Restoration, Backfill, Plugging Ducts, All Hardware and Grounding Installation. | 5 | EA | |
| 4017 | FFP | CAT 6 LAN CABLE | |
| Install, Terminate, and Test CAT 6 LAN Cable. | 100,000 | FT |
(Linear Foot)
| 4018 | FFP | CAT 6 WALL OUTLET BOX | |
| Install CAT 6 Wall Outlet Box. | 100 | EA | |
| 4019 | FFP | NON-METALLIC RACEWAY | |
| Install of Non-Metallic Raceway. | 6,000 | FT |
(Linear Foot)
| 4020 | FFP | 6 TO 12 INCH METAL CABLE LADDER RACK | |
| Install and Bonding of 6 to 12 Inch Metal Cable Ladder Rack. | 10 | FT |
(Linear Foot)
| 4021 | FFP | EQUIPMENT RACK | |
| Install Equipment Rack. | 10 | EA | |
| 4022 | FFP | STRAND AND GUY WIRES FOR AERIAL CABLE | |
| Provide Contractor Furnished Material (CFM) and Install Strand and Guy Wires for Aerial Cable. | 50,000 | FT |
(Linear Foot)
| 4023 | FFP | CABLE ON STRAND USING LASHING MACHINE | |
| Install Cable on Strand Using Lashing Machine to Include Splicing, Termination, and Testing of Cable. | 65,000 | FT |
(Linear Foot)
| 4024 | FFP | SPLICE CASE ON STRAND | |
| Install Splice Case on Strand. | 20 | EA | |
| 4025 | FFP | ½ TO 2 INCH EMT CONDUIT INSIDE | |
| Installation of ½ to 2 Inch Electrical Metallic Tubing (EMT) Conduit Inside of Building. | 15,000 | FT |
(Linear Foot)
| 4026 | FFP | PULL OR DROP BOX FOR PDS | |
| Install Pull or Drop Box for Protected Distribution System (PDS). | 10 | EA | |
| 4027 | FFP | GIP 4 INCH CONDUIT WITH COUPLINGS INSIDE | |
| Provide Contractor Furnished Material (CFM) and Install Galvanized (GIP) 4 Inch Conduit with Couplings Inside of Building. | 40 | FT |
(Linear Foot)
| 4028 | FFP | GIP 4 INCH CONDUIT WITH COUPLINGS BURIED | |
| Provide Contractor Furnished Material (CFM) and Install Galvanized (GIP) 4 Inch Conduit with Couplings Buried at a Minimum of 1 Meter Below the Surface, Encased Within a Minimum of 20 Centimeters of Concrete On All Sides. | 80 | FT |
(Linear Foot)
| 4029 | FFP | DEINSTALL CABLE IN CONDUITS | |
| Deinstall Cable in Conduits. | 200,000 | FT |
(Linear Foot)
| 4030 | FFP | CIS TYPE 25 MILIMETER X 4 EACH | |
| Provide Contractor Furnished Material (CFM) and Install Combined Innerduct System (CIS) Type 25 Milimeter x 4 Each (Black, Yellow, Red, Green). | 2,000 | FT |
(Linear Foot)
| 4031 | FFP | OUTSIDE PULL-BOX | |
| Install Outside Pull-Box (Various Sizes). | 20 | EA | |
| 4032 | FFP | PULLING WIRE IN DUCTS | |
| Provide Contractor Furnished Material (CFM) and Install Pulling Wire in Ducts. | 200,000 | FT |
(Linear Foot)
| 4033 | FFP | ACCOUNTING FOR CONTRACT SERVICES | |
| Contractor Manpower Reporting (CMR) Must be Reported by 31 October of Each Calendar Year During the Life of the Contract. | 1 | JOB | |
| 4034 | INFO | ESTIMATED COST FOR WAR HAZARD LOSSES |
Total Amount for 4th Option Period
File details come from the government source that posted it. Updated .