PRICING WORKSHEET- IFB# W91QF5-17-B-0001 OPTION YEAR TWO (2)

SPEC

ESTIMATED
UNIT
UNIT
ITEM
SECTION
DESCRIPTION
QUANTITY
MEASURE
PRICE

AMOUNT

OPTION YEAR TWO: 11 AUGUST 2019 THRU 10 AUGUST 2020. CONTRACTOR SHALL PROVIDE ALL LABOR, MATERIALS, EQUIPMENT, AND SUPERVISION REQUIRED TO REPAIR OR REPLACE ROOFING ON VARIOUS BUILDINGS LOCATED ON FORT LEE (PETERSBURG), VIRGINIA, IN ACCORDANCE WITH THE TERMS AND SPECIFICATIONS INCORPORATED HEREIN.

ROOF DECKS – CLINS 2001AA THRU 2001AH

2001AA
SECTION R
REMOVE EXISTING AND REPLACE WITH NEW STEEL ROOF DECKING, INCLUDES ALL CLOSURES AND ACCESSORIES.
35
SQ

REMOVE EXISTING WOOD ROOF DECK AND REPLACE WITH NEW WOOD ROOF DECKING. –

CLINS 2001AB THRU 2001AF

2001AB
SECTION R
1" NOMINAL TONGUE AND GROOVE WOOD DECK (TREATED).
300
BF
2001AC
SECTION S
2" NOMINAL TONGUE AND GROOVE WOOD DECK (TREATED).
200
BF
2001AD
SECTION S
3/4" EXTERIOR PLYWOOD (5 PLY).
100
SQ
2001AE
SECTION S
1/2" EXTERIOR PLYWOOD (5 PLY).
100
SQ
2001AF
SECTION Q
REMOVE AND DISPOSE OF EXISTING INSULATION, PER INCH OF DEPTH.
1,000
SQ

PARAPET WALL DAMPPROOFING – CLINS 2001AG AND 2001AH

2001AG
SECTION C
DAMPPROOFING FOR MINOR POROSITY.
100
SF
2001AH
SECTION C
DAMPPROOFING FOR SEVERE POROSITY.
200
SF

PROVIDE RIGID ROOF INSULATION IN CONJUNCTION WITH ROOFING SYSTEMS SPECIFIED. –

CLINS 2001AJ THRU 2001AS

2001AJ
SECTION T
1” THICK POLY-ISO BOARD.
250
SQ
2001AK
SECTION T
1-1/2” THICK POLY-ISO BOARD.
250
SQ
2001AL
SECTION T
2-1/2” THICK POLY-ISO BOARD.
200
SQ
2001AM
SECTION T
PROVIDE VAPOR BARRIER.
450
SQ
2001AN
SECTION T
PROVIDE RESIN-SIZED BUILDING PAPER (15 LB.).
200
SQ
2001AP
SECTION T
PROVIDE TAPERED ROOF INSULATION.
2500
BF
2001AQ
SECTION T
REMOVE EXISTING CANTS AND REPLACE WITH NEW 4" X 4" FIBERBOARD CANTS.
750
LF
2001AR
SECTION T
REMOVE EXISTING CANTS AND REPLACE WITH NEW 4" X 4" TREATED WOOD CANTS.
1,000
LF
2001AS
SECTION S
REMOVE EXISTING NAILERS AND REPLACE WITH NEW 2 X 6 TREATED WOOD NAILERS.
1,000
BF

SHINGLED ROOF SYSTEMS – CLINS 2001AT THRU 2001BC

2001AT
SECTION Q
REMOVE AND DISPOSE OF EXISTING ASPHALT SHINGLES.
1,100
SQ
2001AU
SECTION U
INSTALL NEW SELF-ADHERING MODIFIED BITUMEN UNDERLAYMENT.
2000
SF

PROVIDE NEW ASPHALT SHINGLES – CLINS 2001AV AND 2001AX

2001AV
SECTION U
CLASS A (25 YEAR) ASPHALT SHINGLES WITH A 60 MILE PER HOUR BASIC WIND SPEED WARRANTY.
200
SQ
2001AW
SECTION U
CLASS A (40 YEAR) ARCHITECTURAL ASPHALT SHINGLES WITH AN 80 MILE PER HOUR BASIC WIND SPEED WARRANTY.
150
SQ
2001AX
SECTION U
CLASS A (50 YEAR) ARCHITECTURAL ASPHALT SHINGLES WITH A 110 MILE PER HOUR BASIC WIND SPEED WARRANTY.
100
SQ
2001AY
SECTION Q
REMOVE AND DISPOSE OF EXISTING ROLL ROOFING.
75
SQ
2001AZ
SECTION U
INSTALL NEW ROLL ROOFING.
50
SQ

REMOVE EXISTING PRE-FORMED NON-STRUCTURAL METAL ROOFING AND REPLACE WITH

NEW PRE-FORMED NON-STRUCTURAL METAL ROOFING. – CLINS 2001BD AND 2001BE

2001BA
SECTION W
COATED STEEL ROOFING.
50
SQ
2001BB
SECTION W
COATED ALUMINUM ROOFING.
50
SQ
2001BC
SECTION I
COAT ROOFING WITH ALUMINUM PIGMENTED FIBERED BITUMEN ROOF COATING.
450
SQ

BUILT-UP ROOF SYSTEM – CLINS 2001BD THRU 2001BE

2001BD
SECTION D
FLOOD COAT AND GRAVEL EXISTING BUILT-UP ROOFING.
450
SQ
2001BE
SECTION X
REMOVE AND DISPOSE OF ASBESTOS-CONTAINING ROOFING AND FLASHING IN ACCORDANCE WITH ALL APPLICABLE FEDERAL, STATE AND LOCAL LAWS. INCLUDE ANY NECESSARY TEMPORARY “DRY IN” REQUIREMENTS.
250
SF

REMOVE EXISTING BUILT-UP ROOFING AND REPLACE WITH NEW AGGREGATE SURFACED BUILT-UP

ROOFING SYSTEM. – CLINS 2001BF THRU 2001BJ

2001BF
SECTION T
4-PLY BUILT-UP ROOF SYSTEM.
25
SQ
2001BG
SECTION T
5-PLY BUILT-UP ROOF SYSTEM.
15
SQ
2001BH
SECTION T
REMOVE EXISTING BASE FLASHING AND REPLACE WITH NEW 2-PLY BITUMINOUS BASE FLASHING.
1,000
SF
2001BJ
SECTION T
REMOVE EXISTING BASE FLASHING AND REPLACE WITH NEW 3-PLY BITUMINOUS BASE FLASHING.
1,000
SF

REMOVE EXISTING BUILT-UP ROOFING AND REPLACE WITH NEW SINGLE-PLY REINFORCED MODIFIED

BITUMEN SHEET ROOFING SYSTEM. – CLINS 2001BK THRU 2001BQ

2001BK
SECTION J
160 MIL, TORCH APPLIED ROOF SYSTEM.
100
SQ
2001BL
SECTION J
160 MIL, MOP APPLIED ROOF SYSTEM.
100
SQ
2001BM
SECTION J
REMOVE EXISTING BASE FLASHING AND REPLACE WITH NEW 160 MIL SINGLE-PLY REINFORCED MODIFIED BITUMEN BASE FLASHING.
1,500
SF
2001BN
SECTION J
REMOVE EXISTING BUILT-UP ROOFING AND REPLACE WITH NEW 180 MIL SINGLE-PLY REINFORCED MODIFIED BITUMEN ROOF SYSTEM.
150
SQ
2001BP
SECTION J
REMOVE EXISTING BASE FLASHING AND REPLACE WITH NEW 180 MIL SINGLE-PLY REINFORCED MODIFIED BITUMEN BASE FLASHING.
1,500
SF
2001BQ
SECTION J
INSTALL NEW ASPHALT WALKWAY OR ASPHALT PLANKS.
1,000
SF

CSPE (HYPALON) ROOF SYSTEMS – CLINS 2001BT AND 2001BU

2001BR
SECTION K
REMOVE EXISTING ROOF SYSTEM AND REPLACE WITH NEW MECHANICALLY FASTENED 60 MIL REINFORCED CSPE ROOF SYSTEM.
50
SQ
2001BS
SECTION K
REMOVE EXISTING ROOF SYSTEM AND REPLACE WITH NEW FULLY ADHERED 60 MIL REINFORCED CSPE ROOF SYSTEM.
50
SQ

EPDM ROOF SYSTEMS – CLINS 2001BV THRU 2001CD

2001BT
SECTION L
INSTALL NEW MECHANICALLY FASTENED 60 MIL REINFORCED EPDM ROOF SYSTEM OVER EXISTING BUILT-UP ROOF.
75
SQ
2001BU
SECTION L
INSTALL NEW FULLY ADHERED 60 MIL REINFORCED EPDM ROOF SYSTEM OVER EXISTING BUILT-UP ROOF.
75
SQ
2001BV
SECTION L
REMOVE EXISTING ROOF SYSTEM AND REPLACE WITH NEW BALLASTED 60 MIL REINFORCED EPDM ROOF SYSTEM.
50
SQ
2001BW
SECTION L
REMOVE EXISTING ROOF SYSTEM AND REPLACE WITH NEW MECHANICALLY FASTENED 60 MIL REINFORCED EPDM ROOF SYSTEM.
75
SQ
2001BX
SECTION L
REMOVE EXISTING ROOF SYSTEM AND REPLACE WITH NEW FULLY ADHERED EPDM 60 MIL REINFORCED ROOF SYSTEM.
75
SQ
2001BY
SECTION L
INSTALL NEW EPDM WALL AND CURB FLASHING.
1500
SF
2001BZ
SECTION L
INSTALL RUBBER PIPE VENTS.
67
EA
2001CA
SECTION E
INSTALL TERMINATION BARS.
1500
LF
2001CB
SECTION L
INSTALL WALKPADS.
1300
SF

CPA/PVC ROOF SYSTEMS – CLINS 2001CB AND 2001CC

2001CC
SECTION M
REMOVE EXISTING ROOF SYSTEM AND REPLACE WITH NEW MECHANICALLY FASTENED 60 MIL REINFORCED CPA/PVC ROOF SYSTEM.
50
SQ
2001CD
SECTION M
REMOVE EXISTING ROOF SYSTEM AND REPLACE WITH NEW FULLY ADHERED 60 MIL REINFORCED CPA/PVC ROOF SYSTEM.
50
SQ

TPO ROOF SYSTEMS – CLINS 2001CG AND 2001CH

2001CE
SECTION N
REMOVE EXISTING ROOF SYSTEM AND REPLACE WITH NEW MECHANICALLY FASTENED 60 MIL REINFORCED TPO ROOF SYSTEM.
50
SQ
2001CF
SECTION N
REMOVE EXISTING ROOF SYSTEM AND REPLACE WITH NEW FULLY ADHERED 60 MIL REINFORCED TPO ROOF SYSTEM.
50
SQ

ELASTOMERIC ROOF COATINGS OVER POLYURETHANE FOAM (SPF) – CLINS 2001CJ AND 2001CK

2001CG
SECTION O
INSTALL NEW POLYURETHANE FOAM INSULATION, PER INCH OF DEPTH, INCLUDING PREPARATION OF ROOF DECK OR EXISTING INSULATION TO REMAIN.
125
SQ
2001CH
SECTION O
INSTALL NEW ELASTOMERIC ROOF COATING, INCLUDING PREPARATION OF ROOF DECK, NEW INSULATION OR EXISTING INSULATION TO REMAIN.
75
SQ

REMOVE EXISTING SHEETMETAL ITEMS AND REPLACE WITH NEW SHEETMETAL ITEMS. –

CLINS 2001CL THRU 2001ES

2001CJ
SECTION E
REMOVE EXISTING METAL BASE FLASHING AND REPLACE WITH NEW ALUMINUM BASE FLASHING.
250
SF
2001CK
SECTION E
REMOVE EXISTING METAL BASE FLASHING AND REPLACE WITH NEW COPPER BASE FLASHING.
150
SF
2001CL
SECTION E
REMOVE EXISTING METAL BASE FLASHING AND REPLACE WITH NEW STAINLESS STEEL BASE FLASHING.
50
SF
2001CM
SECTION E
REMOVE EXISTING METAL BASE FLASHING AND REPLACE WITH NEW ALUMINUM STEP FLASHING.
500
SF
2001CN
SECTION E
REMOVE EXISTING METAL BASE FLASHING AND REPLACE WITH NEW COPPER STEP FLASHING.
200
SF
2001CP
SECTION E
REMOVE EXISTING METAL BASE FLASHING AND REPLACE WITH NEW STAINLESS STEEL STEP FLASHING.
100
SF
2001CQ
SECTION E
REMOVE EXISTING METAL COUNTER-FLASHING AND REPLACE WITH NEW ALUMINUM COUNTERFLASHING.
750
LF
2001CR
SECTION E
REMOVE EXISTING METAL COUNTER-FLASHING AND REPLACE WITH NEW COPPER COUNTERFLASHING.
40
LF
2001CS
SECTION E
REMOVE EXISTING METAL COUNTER-FLASHING AND REPLACE WITH NEW STAINLESS STEEL COUNTERFLASHING.
80
LF
2001CT
SECTION E
REMOVE EXISTING METAL GRAVELSTOP AND REPLACE WITH NEW ALUMINUM GRAVELSTOP (UP TO 6" HIGH).
40
LF
2001CU
SECTION E
REMOVE EXISTING METAL GRAVELSTOP AND REPLACE WITH NEW ANODIZED ALUMINUM GRAVELSTOP (UP TO 6" HIGH).
500
LF
2001CV
SECTION E
REMOVE EXISTING METAL GRAVELSTOP AND REPLACE WITH NEW COPPER GRAVELSTOP (UP TO 6" HIGH).
40
LF
2001CW
SECTION E
REMOVE EXISTING METAL GRAVELSTOP AND REPLACE WITH NEW STAINLESS STEEL GRAVELSTOP (UP TO 6"HIGH).
40
LF
2001CX
SECTION E
REMOVE EXISTING METAL GRAVELSTOP AND REPLACE WITH NEW ALUMINUM GRAVELSTOP (6" TO 12" HIGH).
50
LF
2001CY
SECTION E
REMOVE EXISTING METAL GRAVELSTOP AND REPLACE WITH NEW ANODIZED ALUMINUM GRAVELSTOP (6" TO 12" HIGH).
100
LF
2001CZ
SECTION E
REMOVE EXISTING METAL GRAVELSTOP AND REPLACE WITH NEW COPPER GRAVELSTOP (6" TO 12" HIGH).
50
LF
2001DA
SECTION E
REMOVE EXISTING METAL GRAVELSTOP AND REPLACE WITH NEW STAINLESS STEEL GRAVELSTOP (6" TO 12" HIGH).
250
LF
2001DB
SECTION E
REMOVE EXISTING METAL DRIP EDGE AND REPLACE WITH NEW ALUMINUM DRIP EDGE.
4,000
LF
2001DC
SECTION E
REMOVE EXISTING METAL DRIP EDGE AND REPLACE WITH NEW COPPER DRIP EDGE.
75
LF
2001DD
SECTION E
REMOVE EXISTING METAL DRIP EDGE AND REPLACE WITH NEW STAINLESS STEEL DRIP EDGE.
150
LF
2001DE
SECTION E
REMOVE EXISTING OPEN VALLEY FLASHING AND REPLACE WITH NEW ALUMINUM OPEN VALLEY FLASHING.
300
SF
2001DF
SECTION E
REMOVE EXISTING OPEN VALLEY FLASHING AND REPLACE WITH NEW COPPER OPEN VALLEY FLASHING.
150
SF
2001DG
SECTION E
REMOVE EXISTING OPEN VALLEY FLASHING AND REPLACE WITH NEW STAINLESS STEEL OPEN VALLEY FLASHING.
150
SF
2001DH
SECTION E
REMOVE EXISTING METAL COPING AND REPLACE WITH NEW ALUMINUM COPING.
300
SF
2001DJ
SECTION E
REMOVE EXISTING METAL COPING AND REPLACE WITH NEW COPPER COPING.
200
SF
2001DK
SECTION E
REMOVE EXISTING METAL COPING AND REPLACE WITH NEW STAINLESS STEEL COPING.
300
SF
2001DL
SECTION E
REMOVE EXISTING METAL EXPANSION JOINTS AND REPLACE WITH NEW ALUMINUM EXPANSION JOINTS.
300
SF
2001DM
SECTION E
REMOVE EXISTING METAL EXPANSION JOINTS AND REPLACE WITH NEW COPPER EXPANSION JOINTS.
50
SF
2001DN
SECTION E
REMOVE EXISTING METAL EXPANSION JOINTS AND REPLACE WITH NEW STAINLESS STEEL EXPANSION JOINTS.
67
SF
2001DP
SECTION E
REMOVE EXISTING FLASHING WITH MISCELLANEOUS SHAPES AND REPLACE WITH NEW ALUMINUM FLASHING.
450
SF
2001DQ
SECTION E
REMOVE EXISTING FLASHING WITH MISCELLANEOUS SHAPES AND REPLACE WITH NEW COPPER FLASHING.
250
SF
2001DR
SECTION E
REMOVE EXISTING FLASHING WITH MISCELLANEOUS SHAPES AND REPLACE WITH NEW STAINLESS STEEL FLASHING.
150
SF
2001DS
SECTION E
INSTALL NEW 5-INCH WIDE PRE-FINISHED ALUMINUM OGEE GUTTERS.
650
LF
2001DT
SECTION E
INSTALL NEW 6-INCH WIDE PRE-FINISHED ALUMINUM OGEE GUTTERS.
650
LF
2001DU
SECTION E
INSTALL NEW 6-INCH WIDE COPPER BOX GUTTERS.
500
LF
2001DV
SECTION E
INSTALL NEW 8-INCH WIDE COPPER BOX GUTTERS.
30
LF
2001DW
SECTION E
INSTALL NEW 5-INCH WIDE COPPER HALF ROUND GUTTERS.
150
LF
2001DX
SECTION E
INSTALL NEW 6-INCH WIDE COPPER HALF ROUND GUTTERS.
100
LF
2001DY
SECTION E
INSTALL NEW 5-INCH WIDE COPPER OGEE GUTTERS.
150
LF
2001DZ
SECTION E
INSTALL NEW 6-INCH WIDE COPPER OGEE GUTTERS.
150
LF
2001EA
SECTION E
INSTALL NEW 6-INCH WIDE STAINLESS STEEL BOX GUTTERS.
250
LF
2001EB
SECTION E
INSTALL NEW 2-1/4" X 3-1/4" PRE-FINISHED ALUMINUM DOWNSPOUTS.
300
LF
2001EC
SECTION E
INSTALL NEW 3" X 4" PREFINISHED ALUMINUM DOWNSPOUTS.
1,000
LF
2001ED
SECTION E
INSTALL NEW 2-1/4" X 3-1/4" COPPER DOWNSPOUTS.
250
LF
2001EE
SECTION E
INSTALL NEW 3" X 4" COPPER DOWNSPOUTS.
500
LF
2001EF
SECTION E
INSTALL NEW 3" ROUND COPPER DOWNSPOUTS.
100
LF
2001EG
SECTION E
INSTALL NEW 4" ROUND COPPER DOWNSPOUTS.
250
LF
2001EH
SECTION E
INSTALL NEW 6" ROUND COPPER DOWNSPOUTS.
200
LF
2001EJ
SECTION E
INSTALL NEW 3" X 4" STAINLESS STEEL DOWNSPOUTS.
250
LF
2001EK
SECTION E
REMOVE EXISTING METAL CONDUCTOR HEADS AND REPLACE WITH NEW COPPER CONDUCTOR HEADS.
30
SF
2001EL
SECTION E
REMOVE EXISTING METAL CONDUCTOR HEADS AND REPLACE WITH NEW STAINLESS STEEL CONDUCTOR HEADS.
30
SF
2001EM
SECTION E
REMOVE EXISTING METAL SCUPPER LINING AND REPLACE WITH NEW COPPER SCUPPER LINING.
30
SF
2001EN
SECTION E
REMOVE EXISTING METAL SCUPPER LINING AND REPLACE WITH NEW STAINLESS STEEL SCUPPER LINING.
30
SF
2001EP
SECTION E
REMOVE AND REINSTALL EXISTING GUTTERS AND DOWNSPOUTS.
150
LF
2001EQ
SECTION E
REALIGN AND RESECURE EXISTING GUTTERS AND DOWNSPOUTS, INCLUDES ALL NEW HARDWARE.
3,000
LF
2001ER
SECTION E
REMOVE AND DISPOSE OF EXISTING GUTTERS AND DOWNSPOUTS.
7,000
LF
2001ES
SECTION E
RESOLDER GUTTER JOINTS.
50
EA
2001ET
SECTION P
REPAIR BROKEN GUTTER JOINTS WITH SEALANT.
50
EA
2001EU
SECTION Q
CLEAN AND DISPOSE OF DEBRIS IN GUTTERS.
$3,500
LF
2001EV
-- -- --
INSTALL NEW COMMERCIAL-SIZED CONCRETE SPLASHBLOCKS.
50
EA
2001EW
SECTION E
INSTALL NEW COPPER SPLASHPANS.
10
EA
2001EX
SECTION E
INSTALL NEW STAINLESS STEEL SPLASHPANS.
10
EA
2001EY
SECTION Q
CLEAN AND CLEAR ROOF DRAINS.
50
EA
2001EZ
SECTION E
REMOVE EXISTING ROOF DRAIN SUMPS AND REPLACE WITH NEW 6-POUND LEAD DRAIN SUMPS (24" X 24" WITH 4"FLANGE).
30
EA
2001FA
-- -- --
REMOVE EXISTING ROOF DRAIN SUMPS AND REPLACE WITH NEW PVC DRAIN SUMPS (24" X 24" WITH 4"FLANGE).
17
EA
2001FB
SECTION Q
REMOVE EXISTING ROOF DRAIN STRAINERS AND REPLACE WITH NEW METAL ROOF DRAIN STRAINERS.
10
EA
2001FC
SECTION Q
REMOVE EXISTING ROOF DRAIN STRAINERS AND REPLACE WITH NEW POLY (VINYL CHLORIDE) (PVC) ROOF DRAIN STRAINERS.
10
EA

REMOVE EXISTING ROOF DRAIN AND REPLACE WITH NEW ROOF DRAIN, JOSAN 22010 SERIES,

COATED CAST IRON, OR EQUAL, WITH METAL STRAINER AND INCLUDING ALL ACCESSORIES

AND FLASHINGS. – CLINS 2001FF THRU 2001FL

2001FD
-- -- --
3-INCH DIAMETER ROOF DRAIN.
7
EA
2001FE
-- -- --
4-INCH DIAMETER ROOF DRAIN.
10
EA
2001FF
-- -- --
6-INCH DIAMETER ROOF DRAIN.
7
EA
2001FG
-- -- --
REMOVE EXISTING DRAIN PIPE WITH AND REPLACE WITH NEW 3" DIAMETER SCHEDULE 40 PVC DRAIN PIPE, INCLUDING ELBOWS, COUPLINGS, ETC.
150
LF
2001FH
-- -- --
REMOVE EXISTING DRAIN PIPE WITH AND REPLACE WITH NEW 4" DIAMETER SCHEDULE 40 PVC DRAIN PIPE, INCLUDING ELBOWS, COUPLINGS, ETC.
300
LF
2001FJ
-- -- --
REMOVE EXISTING DRAIN PIPE WITH AND REPLACE WITH NEW 6" DIAMETER SCHEDULE 40 PVC DRAIN PIPE, INCLUDING ELBOWS, COUPLINGS, ETC.
150
LF
2001FK
SECTION E
REMOVE EXISTING PITCH POCKET AND REPLACE WITH NEW COPPER PITCH POCKET, INCLUDING NAILERS, FLASHING, COUNTERFLASHING, METAL JOINT

COVER, ETC.

75
EA
2001FL
SECTION E
REMOVE EXISTING PITCH POCKET AND REPLACE WITH NEW STAINLESS STEEL PITCH POCKET, INCLUDING NAILERS, FLASHING, COUNTERFLASHING, METAL JOINT COVER, ETC.
75
EA
2001FM
SECTION E
REMOVE AND REPLACE EXISTING PITCH FROM PITCH POCKETAND REPAIR PITCH POCKET.
50
CF
2001FN
SECTION E
REMOVE EXISTING PIPE VENT FLASHING AND REPLACE WITH NEW LEAD PIPE VENT FLASHING.
50
EA
2001FP
SECTION F
REMOVE EXISTING ROOF HATCH AND REPLACE WITH NEW 2'-6" X 3'-6" ROOF HATCH WITH ALUMINUM CURB AND COVER.
14
EA
2001FQ
SECTION E
REMOVE EXISTING PIPE VENT FLASHING AND REPLACE WITH NEW GALV-NEOPRENE PIPE VENT FLASHING.
50
EA
2001FR
SECTION P
INSTALL NEW JOINT SEALANT.
3,000
LF
2001FS
SECTION P
REMOVE EXISTING JOINT SEALANT AND INSTALL NEW JOINT SEALANT.
2,600
LF
2001FT
SECTION Q
CUT NEW REGLET IN MASONRY.
300
LF
2001FU
SECTION Q
CUT NEW REGLET IN CONCRETE.
100
LF
2001FV
SECTION Q
REMOVE AND REINSTALL EXISTING ATTIC VENTILATORS.
17
EA
2001FW
SECTION E
REMOVE EXISTING ATTIC VENTILATORS AND REPLACE WITH NEW RESIDENTIAL OR COMMMERCIAL VENTILATORS.
50
LF
2001FX
SECTION U
REMOVE EXISTING RIDGE VENT AND REPLACE WITH NEW CONTINUOUS RIDGE VENT.
2,000
LF
2001FY
SECTION S

SECTION G

REMOVE EXISTING WOOD FASCIA AND REPLACE WITH NEW PAINTED WOOD FASCIA BOARD. (USE THIS ITEM FOR STANDARD-DIMENSIONED LUMBER.)
750
BF
2001GA
SECTION S

SECTION G

REMOVE EXISTING WOOD FASCIA AND REPLACE WITH NEW PAINTED WOOD FASCIA BOARD. (USE THIS ITEM FOR CUSTOM-MILLED LUMBER.)
150
BF

REMOVE EXISTING PRE-FORMED NON-STRUCTURAL METAL ROOFING AND REPLACE WITH

NEW PRE-FORMED NON-STRUCTURAL METAL ROOFING. – CLINS 2001 - - AND 2001 - -

2001GB
SECTION H
COATED STEEL ROOFING.
50
SQ
2001GC
SECTION H
COATED ALUMINUM ROOFING.
50
SQ
2001GD
SECTION Q
DISCONNECT AND RECONNECT EXISTING ROOF-MOUNTED ELECTRICAL EQUIPMENT.
34
EA
SECTION Q
LABOR CHARGES FOR ROOF LEAK INVESTIGATION AND REPAIRS. (THIS ITEM TO BE USED WITH MATERIALS FOR ISOLATED MINOR ROOF LEAK REPAIRS.)
300
HR

CONSTRUCTION AIDS - CLINS 2001GE AND 2001GH

2001GE
SECTION A
PROVIDE FIXED STEEL TUBULAR SCAFFOLDING. (COST PER CSF OF BUILDING; ONE USE PER MONTH.)
34
CSF
2001GF
SECTION A
PROVIDE MOBILE SCAFFOLD. (COST FOR

40-FOOT AERIAL LIFT.)

34
MO
2001GG
SECTION A
SURVEY EXISTING ROOF SYSTEM AND PROVIDE A WRITTEN REPORT DETAILING EXISTING CONDITIONS AND REQUIRED MAINTENANCE.
34
SQ
2001GH
SECTION A
SURVEY EXISTING ROOF SYSTEM AND BUILDING STRUCTURE AND PROVIDE A WRITTEN REPORT DETAILING EXISTING STRUCTURAL CONDITIONS, LOAD CALCULATIONS & CAPABILITIES AND REQUIRED MAINTENANCE.
50
SQ

OPTION YEAR TWO: ESTIMATED TOTAL ( LINE ITEMS 2001AA THROUGH 2001GH)