ATTACHMENT_2_PRICING_WORKSHEET_OPTION_YEAR_ONE.docx

DOCX document 31 KB Posted

Attached to
Fort Lee Roofing Repair and Replacement
Solicitation number
W91QF517B0001
Issued by

About this file

Pricing Worksheet - Option Year One

View the file

Other files

Show all 14

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

PRICING WORKSHEET- IFB# W91QF5-17-B-0001 OPTION YEAR ONE (1)

SPEC

ESTIMATED
UNIT
UNIT
ITEM
SECTION
DESCRIPTION
QUANTITY
MEASURE
PRICE

AMOUNT

OPTION YEAR ONE: 11 AUGUST 2018 THRU 10 AUGUST 2019. CONTRACTOR SHALL PROVIDE ALL LABOR, MATERIALS, EQUIPMENT, AND SUPERVISION REQUIRED TO REPAIR OR REPLACE ROOFING ON VARIOUS BUILDINGS LOCATED ON FORT LEE (PETERSBURG), VIRGINIA, IN ACCORDANCE WITH THE TERMS AND SPECIFICATIONS INCORPORATED HEREIN.

ROOF DECKS – CLINS 1001AA THRU 1001AH

1001AA
SECTION R
REMOVE EXISTING AND REPLACE WITH NEW STEEL ROOF DECKING, INCLUDES ALL CLOSURES AND ACCESSORIES.
35
SQ

REMOVE EXISTING WOOD ROOF DECK AND REPLACE WITH NEW WOOD ROOF DECKING. –

CLINS 1001AB THRU 1001AF

1001AB
SECTION R
1" NOMINAL TONGUE AND GROOVE WOOD DECK (TREATED).
300
BF
1001AC
SECTION S
2" NOMINAL TONGUE AND GROOVE WOOD DECK (TREATED).
200
BF
1001AD
SECTION S
3/4" EXTERIOR PLYWOOD (5 PLY).
100
SQ
1001AE
SECTION S
1/2" EXTERIOR PLYWOOD (5 PLY).
100
SQ
1001AF
SECTION Q
REMOVE AND DISPOSE OF EXISTING INSULATION, PER INCH OF DEPTH.
1,000
SQ

PARAPET WALL DAMPPROOFING – CLINS 1001AG AND 1001AH

1001AG
SECTION C
DAMPPROOFING FOR MINOR POROSITY.
100
SF
1001AH
SECTION C
DAMPPROOFING FOR SEVERE POROSITY.
200
SF

PROVIDE RIGID ROOF INSULATION IN CONJUNCTION WITH ROOFING SYSTEMS SPECIFIED. –

CLINS 1001AJ THRU 1001AS

1001AJ
SECTION T
1” THICK POLY-ISO BOARD.
250
SQ
1001AK
SECTION T
1-1/2” THICK POLY-ISO BOARD.
250
SQ
1001AL
SECTION T
2-1/2” THICK POLY-ISO BOARD.
200
SQ
1001AM
SECTION T
PROVIDE VAPOR BARRIER.
450
SQ
0001AN
SECTION T
PROVIDE RESIN-SIZED BUILDING PAPER (15 LB.).
200
SQ
1001AP
SECTION T
PROVIDE TAPERED ROOF INSULATION.
2500
BF
0001AQ
SECTION T
REMOVE EXISTING CANTS AND REPLACE WITH NEW 4" X 4" FIBERBOARD CANTS.
750
LF
1001AR
SECTION T
REMOVE EXISTING CANTS AND REPLACE WITH NEW 4" X 4" TREATED WOOD CANTS.
1,000
LF
1001AS
SECTION S
REMOVE EXISTING NAILERS AND REPLACE WITH NEW 2 X 6 TREATED WOOD NAILERS.
1,000
BF

SHINGLED ROOF SYSTEMS – CLINS 1001AT THRU 1001BC

1001AT
SECTION Q
REMOVE AND DISPOSE OF EXISTING ASPHALT SHINGLES.
1,100
SQ
1001AU
SECTION U
INSTALL NEW SELF-ADHERING MODIFIED BITUMEN UNDERLAYMENT.
2000
SF

PROVIDE NEW ASPHALT SHINGLES – CLINS 1001AV AND 1001AX

1001AV
SECTION U
CLASS A (25 YEAR) ASPHALT SHINGLES WITH A 60 MILE PER HOUR BASIC WIND SPEED WARRANTY.
200
SQ
1001AW
SECTION U
CLASS A (40 YEAR) ARCHITECTURAL ASPHALT SHINGLES WITH AN 80 MILE PER HOUR BASIC WIND SPEED WARRANTY.
150
SQ
1001AX
SECTION U
CLASS A (50 YEAR) ARCHITECTURAL ASPHALT SHINGLES WITH A 110 MILE PER HOUR BASIC WIND SPEED WARRANTY.
100
SQ
1001AY
SECTION Q
REMOVE AND DISPOSE OF EXISTING ROLL ROOFING.
75
SQ
1001AZ
SECTION U
INSTALL NEW ROLL ROOFING.
50
SQ

REMOVE EXISTING PRE-FORMED NON-STRUCTURAL METAL ROOFING AND REPLACE WITH

NEW PRE-FORMED NON-STRUCTURAL METAL ROOFING. – CLINS 1001BD AND 1001BE

1001BA
SECTION W
COATED STEEL ROOFING.
50
SQ
1001BB
SECTION W
COATED ALUMINUM ROOFING.
50
SQ
1001BC
SECTION I
COAT ROOFING WITH ALUMINUM PIGMENTED FIBERED BITUMEN ROOF COATING.
450
SQ

BUILT-UP ROOF SYSTEM – CLINS 1001BD THRU 1001BE

1001BD
SECTION D
FLOOD COAT AND GRAVEL EXISTING BUILT-UP ROOFING.
450
SQ
1001BE
SECTION X
REMOVE AND DISPOSE OF ASBESTOS-CONTAINING ROOFING AND FLASHING IN ACCORDANCE WITH ALL APPLICABLE FEDERAL, STATE AND LOCAL LAWS. INCLUDE ANY NECESSARY TEMPORARY “DRY IN” REQUIREMENTS.
250
SF

REMOVE EXISTING BUILT-UP ROOFING AND REPLACE WITH NEW AGGREGATE SURFACED BUILT-UP

ROOFING SYSTEM. – CLINS 1001BF THRU 1001BJ

1001BF
SECTION T
4-PLY BUILT-UP ROOF SYSTEM.
25
SQ
1001BG
SECTION T
5-PLY BUILT-UP ROOF SYSTEM.
15
SQ
0001BH
SECTION T
REMOVE EXISTING BASE FLASHING AND REPLACE WITH NEW 2-PLY BITUMINOUS BASE FLASHING.
1,000
SF
1001BJ
SECTION T
REMOVE EXISTING BASE FLASHING AND REPLACE WITH NEW 3-PLY BITUMINOUS BASE FLASHING.
1,000
SF

REMOVE EXISTING BUILT-UP ROOFING AND REPLACE WITH NEW SINGLE-PLY REINFORCED MODIFIED

BITUMEN SHEET ROOFING SYSTEM. – CLINS 1001BK THRU 1001BQ

1001BK
SECTION J
160 MIL, TORCH APPLIED ROOF SYSTEM.
100
SQ
1001BL
SECTION J
160 MIL, MOP APPLIED ROOF SYSTEM.
100
SQ
1001BM
SECTION J
REMOVE EXISTING BASE FLASHING AND REPLACE WITH NEW 160 MIL SINGLE-PLY REINFORCED MODIFIED BITUMEN BASE FLASHING.
1,500
SF
1001BN
SECTION J
REMOVE EXISTING BUILT-UP ROOFING AND REPLACE WITH NEW 180 MIL SINGLE-PLY REINFORCED MODIFIED BITUMEN ROOF SYSTEM.
150
SQ
1001BP
SECTION J
REMOVE EXISTING BASE FLASHING AND REPLACE WITH NEW 180 MIL SINGLE-PLY REINFORCED MODIFIED BITUMEN BASE FLASHING.
1,500
SF
1001BQ
SECTION J
INSTALL NEW ASPHALT WALKWAY OR ASPHALT PLANKS.
1,000
SF

CSPE (HYPALON) ROOF SYSTEMS – CLINS 1001BT AND 1001BU

1001BR
SECTION K
REMOVE EXISTING ROOF SYSTEM AND REPLACE WITH NEW MECHANICALLY FASTENED 60 MIL REINFORCED CSPE ROOF SYSTEM.
50
SQ
1001BS
SECTION K
REMOVE EXISTING ROOF SYSTEM AND REPLACE WITH NEW FULLY ADHERED 60 MIL REINFORCED CSPE ROOF SYSTEM.
50
SQ

EPDM ROOF SYSTEMS – CLINS 1001BV THRU 1001CD

1001BT
SECTION L
INSTALL NEW MECHANICALLY FASTENED 60 MIL REINFORCED EPDM ROOF SYSTEM OVER EXISTING BUILT-UP ROOF.
75
SQ
1001BU
SECTION L
INSTALL NEW FULLY ADHERED 60 MIL REINFORCED EPDM ROOF SYSTEM OVER EXISTING BUILT-UP ROOF.
75
SQ
1001BV
SECTION L
REMOVE EXISTING ROOF SYSTEM AND REPLACE WITH NEW BALLASTED 60 MIL REINFORCED EPDM ROOF SYSTEM.
50
SQ
1001BW
SECTION L
REMOVE EXISTING ROOF SYSTEM AND REPLACE WITH NEW MECHANICALLY FASTENED 60 MIL REINFORCED EPDM ROOF SYSTEM.
75
SQ
1001BX
SECTION L
REMOVE EXISTING ROOF SYSTEM AND REPLACE WITH NEW FULLY ADHERED EPDM 60 MIL REINFORCED ROOF SYSTEM.
75
SQ
1001BY
SECTION L
INSTALL NEW EPDM WALL AND CURB FLASHING.
1500
SF
1001BZ
SECTION L
INSTALL RUBBER PIPE VENTS.
67
EA
1001CA
SECTION E
INSTALL TERMINATION BARS.
1500
LF
1001CB
SECTION L
INSTALL WALKPADS.
1300
SF

CPA/PVC ROOF SYSTEMS – CLINS 1001CB AND 1001CC

0001CC
SECTION M
REMOVE EXISTING ROOF SYSTEM AND REPLACE WITH NEW MECHANICALLY FASTENED 60 MIL REINFORCED CPA/PVC ROOF SYSTEM.
50
SQ
1001CD
SECTION M
REMOVE EXISTING ROOF SYSTEM AND REPLACE WITH NEW FULLY ADHERED 60 MIL REINFORCED CPA/PVC ROOF SYSTEM.
50
SQ

TPO ROOF SYSTEMS – CLINS 1001CG AND 1001CH

1001CE
SECTION N
REMOVE EXISTING ROOF SYSTEM AND REPLACE WITH NEW MECHANICALLY FASTENED 60 MIL REINFORCED TPO ROOF SYSTEM.
50
SQ
1001CF
SECTION N
REMOVE EXISTING ROOF SYSTEM AND REPLACE WITH NEW FULLY ADHERED 60 MIL REINFORCED TPO ROOF SYSTEM.
50
SQ

ELASTOMERIC ROOF COATINGS OVER POLYURETHANE FOAM (SPF) – CLINS 1001CJ AND 1001CK

1001CG
SECTION O
INSTALL NEW POLYURETHANE FOAM INSULATION, PER INCH OF DEPTH, INCLUDING PREPARATION OF ROOF DECK OR EXISTING INSULATION TO REMAIN.
125
SQ
1001CH
SECTION O
INSTALL NEW ELASTOMERIC ROOF COATING, INCLUDING PREPARATION OF ROOF DECK, NEW INSULATION OR EXISTING INSULATION TO REMAIN.
75
SQ

REMOVE EXISTING SHEETMETAL ITEMS AND REPLACE WITH NEW SHEETMETAL ITEMS. –

CLINS 1001CL THRU 1001ES

1001CJ
SECTION E
REMOVE EXISTING METAL BASE FLASHING AND REPLACE WITH NEW ALUMINUM BASE FLASHING.
250
SF
1001CK
SECTION E
REMOVE EXISTING METAL BASE FLASHING AND REPLACE WITH NEW COPPER BASE FLASHING.
150
SF
1001CL
SECTION E
REMOVE EXISTING METAL BASE FLASHING AND REPLACE WITH NEW STAINLESS STEEL BASE FLASHING.
50
SF
1001CM
SECTION E
REMOVE EXISTING METAL BASE FLASHING AND REPLACE WITH NEW ALUMINUM STEP FLASHING.
500
SF
1001CN
SECTION E
REMOVE EXISTING METAL BASE FLASHING AND REPLACE WITH NEW COPPER STEP FLASHING.
200
SF
1001CP
SECTION E
REMOVE EXISTING METAL BASE FLASHING AND REPLACE WITH NEW STAINLESS STEEL STEP FLASHING.
100
SF
1001CQ
SECTION E
REMOVE EXISTING METAL COUNTER-FLASHING AND REPLACE WITH NEW ALUMINUM COUNTERFLASHING.
750
LF
1001CR
SECTION E
REMOVE EXISTING METAL COUNTER-FLASHING AND REPLACE WITH NEW COPPER COUNTERFLASHING.
40
LF
1001CS
SECTION E
REMOVE EXISTING METAL COUNTER-FLASHING AND REPLACE WITH NEW STAINLESS STEEL COUNTERFLASHING.
80
LF
1001CT
SECTION E
REMOVE EXISTING METAL GRAVELSTOP AND REPLACE WITH NEW ALUMINUM GRAVELSTOP (UP TO 6" HIGH).
40
LF
1001CU
SECTION E
REMOVE EXISTING METAL GRAVELSTOP AND REPLACE WITH NEW ANODIZED ALUMINUM GRAVELSTOP (UP TO 6" HIGH).
500
LF
1001CV
SECTION E
REMOVE EXISTING METAL GRAVELSTOP AND REPLACE WITH NEW COPPER GRAVELSTOP (UP TO 6" HIGH).
40
LF
1001CW
SECTION E
REMOVE EXISTING METAL GRAVELSTOP AND REPLACE WITH NEW STAINLESS STEEL GRAVELSTOP (UP TO 6"HIGH).
40
LF
1001CX
SECTION E
REMOVE EXISTING METAL GRAVELSTOP AND REPLACE WITH NEW ALUMINUM GRAVELSTOP (6" TO 12" HIGH).
50
LF
1001CY
SECTION E
REMOVE EXISTING METAL GRAVELSTOP AND REPLACE WITH NEW ANODIZED ALUMINUM GRAVELSTOP (6" TO 12" HIGH).
100
LF
1001CZ
SECTION E
REMOVE EXISTING METAL GRAVELSTOP AND REPLACE WITH NEW COPPER GRAVELSTOP (6" TO 12" HIGH).
50
LF
1001DA
SECTION E
REMOVE EXISTING METAL GRAVELSTOP AND REPLACE WITH NEW STAINLESS STEEL GRAVELSTOP (6" TO 12" HIGH).
250
LF
1001DB
SECTION E
REMOVE EXISTING METAL DRIP EDGE AND REPLACE WITH NEW ALUMINUM DRIP EDGE.
4,000
LF
1001DC
SECTION E
REMOVE EXISTING METAL DRIP EDGE AND REPLACE WITH NEW COPPER DRIP EDGE.
75
LF
1001DD
SECTION E
REMOVE EXISTING METAL DRIP EDGE AND REPLACE WITH NEW STAINLESS STEEL DRIP EDGE.
150
LF
1001DE
SECTION E
REMOVE EXISTING OPEN VALLEY FLASHING AND REPLACE WITH NEW ALUMINUM OPEN VALLEY FLASHING.
300
SF
1001DF
SECTION E
REMOVE EXISTING OPEN VALLEY FLASHING AND REPLACE WITH NEW COPPER OPEN VALLEY FLASHING.
150
SF
1001DG
SECTION E
REMOVE EXISTING OPEN VALLEY FLASHING AND REPLACE WITH NEW STAINLESS STEEL OPEN VALLEY FLASHING.
150
SF
1001DH
SECTION E
REMOVE EXISTING METAL COPING AND REPLACE WITH NEW ALUMINUM COPING.
300
SF
1001DJ
SECTION E
REMOVE EXISTING METAL COPING AND REPLACE WITH NEW COPPER COPING.
200
SF
1001DK
SECTION E
REMOVE EXISTING METAL COPING AND REPLACE WITH NEW STAINLESS STEEL COPING.
300
SF
1001DL
SECTION E
REMOVE EXISTING METAL EXPANSION JOINTS AND REPLACE WITH NEW ALUMINUM EXPANSION JOINTS.
300
SF
1001DM
SECTION E
REMOVE EXISTING METAL EXPANSION JOINTS AND REPLACE WITH NEW COPPER EXPANSION JOINTS.
50
SF
1001DN
SECTION E
REMOVE EXISTING METAL EXPANSION JOINTS AND REPLACE WITH NEW STAINLESS STEEL EXPANSION JOINTS.
67
SF
1001DP
SECTION E
REMOVE EXISTING FLASHING WITH MISCELLANEOUS SHAPES AND REPLACE WITH NEW ALUMINUM FLASHING.
450
SF
1001DQ
SECTION E
REMOVE EXISTING FLASHING WITH MISCELLANEOUS SHAPES AND REPLACE WITH NEW COPPER FLASHING.
250
SF
1001DR
SECTION E
REMOVE EXISTING FLASHING WITH MISCELLANEOUS SHAPES AND REPLACE WITH NEW STAINLESS STEEL FLASHING.
150
SF
1001DS
SECTION E
INSTALL NEW 5-INCH WIDE PRE-FINISHED ALUMINUM OGEE GUTTERS.
650
LF
1001DT
SECTION E
INSTALL NEW 6-INCH WIDE PRE-FINISHED ALUMINUM OGEE GUTTERS.
650
LF
1001DU
SECTION E
INSTALL NEW 6-INCH WIDE COPPER BOX GUTTERS.
500
LF
1001DV
SECTION E
INSTALL NEW 8-INCH WIDE COPPER BOX GUTTERS.
30
LF
1001DW
SECTION E
INSTALL NEW 5-INCH WIDE COPPER HALF ROUND GUTTERS.
150
LF
1001DX
SECTION E
INSTALL NEW 6-INCH WIDE COPPER HALF ROUND GUTTERS.
100
LF
1001DY
SECTION E
INSTALL NEW 5-INCH WIDE COPPER OGEE GUTTERS.
150
LF
1001DZ
SECTION E
INSTALL NEW 6-INCH WIDE COPPER OGEE GUTTERS.
150
LF
1001EA
SECTION E
INSTALL NEW 6-INCH WIDE STAINLESS STEEL BOX GUTTERS.
250
LF
1001EB
SECTION E
INSTALL NEW 2-1/4" X 3-1/4" PRE-FINISHED ALUMINUM DOWNSPOUTS.
300
LF
1001EC
SECTION E
INSTALL NEW 3" X 4" PREFINISHED ALUMINUM DOWNSPOUTS.
1,000
LF
1001ED
SECTION E
INSTALL NEW 2-1/4" X 3-1/4" COPPER DOWNSPOUTS.
250
LF
0001EE
SECTION E
INSTALL NEW 3" X 4" COPPER DOWNSPOUTS.
500
LF
1001EF
SECTION E
INSTALL NEW 3" ROUND COPPER DOWNSPOUTS.
100
LF
1001EG
SECTION E
INSTALL NEW 4" ROUND COPPER DOWNSPOUTS.
250
LF
1001EH
SECTION E
INSTALL NEW 6" ROUND COPPER DOWNSPOUTS.
200
LF
1001EJ
SECTION E
INSTALL NEW 3" X 4" STAINLESS STEEL DOWNSPOUTS.
250
LF
1001EK
SECTION E
REMOVE EXISTING METAL CONDUCTOR HEADS AND REPLACE WITH NEW COPPER CONDUCTOR HEADS.
30
SF
1001EL
SECTION E
REMOVE EXISTING METAL CONDUCTOR HEADS AND REPLACE WITH NEW STAINLESS STEEL CONDUCTOR HEADS.
30
SF
1001EM
SECTION E
REMOVE EXISTING METAL SCUPPER LINING AND REPLACE WITH NEW COPPER SCUPPER LINING.
30
SF
1001EN
SECTION E
REMOVE EXISTING METAL SCUPPER LINING AND REPLACE WITH NEW STAINLESS STEEL SCUPPER LINING.
30
SF
1001EP
SECTION E
REMOVE AND REINSTALL EXISTING GUTTERS AND DOWNSPOUTS.
150
LF
1001EQ
SECTION E
REALIGN AND RESECURE EXISTING GUTTERS AND DOWNSPOUTS, INCLUDES ALL NEW HARDWARE.
3,000
LF
1001ER
SECTION E
REMOVE AND DISPOSE OF EXISTING GUTTERS AND DOWNSPOUTS.
7,000
LF
1001ES
SECTION E
RESOLDER GUTTER JOINTS.
50
EA
1001ET
SECTION P
REPAIR BROKEN GUTTER JOINTS WITH SEALANT.
50
EA
1001EU
SECTION Q
CLEAN AND DISPOSE OF DEBRIS IN GUTTERS.
$3,500
LF
1001EV
-- -- --
INSTALL NEW COMMERCIAL-SIZED CONCRETE SPLASHBLOCKS.
50
EA
1001EW
SECTION E
INSTALL NEW COPPER SPLASHPANS.
10
EA
1001EX
SECTION E
INSTALL NEW STAINLESS STEEL SPLASHPANS.
10
EA
1001EY
SECTION Q
CLEAN AND CLEAR ROOF DRAINS.
50
EA
1001EZ
SECTION E
REMOVE EXISTING ROOF DRAIN SUMPS AND REPLACE WITH NEW 6-POUND LEAD DRAIN SUMPS (24" X 24" WITH 4"FLANGE).
30
EA
1001FA
-- -- --
REMOVE EXISTING ROOF DRAIN SUMPS AND REPLACE WITH NEW PVC DRAIN SUMPS (24" X 24" WITH 4"FLANGE).
17
EA
1001FB
SECTION Q
REMOVE EXISTING ROOF DRAIN STRAINERS AND REPLACE WITH NEW METAL ROOF DRAIN STRAINERS.
10
EA
1001FC
SECTION Q
REMOVE EXISTING ROOF DRAIN STRAINERS AND REPLACE WITH NEW POLY (VINYL CHLORIDE) (PVC) ROOF DRAIN STRAINERS.
10
EA

REMOVE EXISTING ROOF DRAIN AND REPLACE WITH NEW ROOF DRAIN, JOSAN 22010 SERIES,

COATED CAST IRON, OR EQUAL, WITH METAL STRAINER AND INCLUDING ALL ACCESSORIES

AND FLASHINGS. – CLINS 1001FF THRU 1001FL

1001FD
-- -- --
3-INCH DIAMETER ROOF DRAIN.
7
EA
1001FE
-- -- --
4-INCH DIAMETER ROOF DRAIN.
10
EA
1001FF
-- -- --
6-INCH DIAMETER ROOF DRAIN.
7
EA
1001FG
-- -- --
REMOVE EXISTING DRAIN PIPE WITH AND REPLACE WITH NEW 3" DIAMETER SCHEDULE 40 PVC DRAIN PIPE, INCLUDING ELBOWS, COUPLINGS, ETC.
150
LF
1001FH
-- -- --
REMOVE EXISTING DRAIN PIPE WITH AND REPLACE WITH NEW 4" DIAMETER SCHEDULE 40 PVC DRAIN PIPE, INCLUDING ELBOWS, COUPLINGS, ETC.
300
LF
1001FJ
-- -- --
REMOVE EXISTING DRAIN PIPE WITH AND REPLACE WITH NEW 6" DIAMETER SCHEDULE 40 PVC DRAIN PIPE, INCLUDING ELBOWS, COUPLINGS, ETC.
150
LF
1001FK
SECTION E
REMOVE EXISTING PITCH POCKET AND REPLACE WITH NEW COPPER PITCH POCKET, INCLUDING NAILERS, FLASHING, COUNTERFLASHING, METAL JOINT

COVER, ETC.

75
EA
1001FL
SECTION E
REMOVE EXISTING PITCH POCKET AND REPLACE WITH NEW STAINLESS STEEL PITCH POCKET, INCLUDING NAILERS, FLASHING, COUNTERFLASHING, METAL JOINT COVER, ETC.
75
EA
1001FM
SECTION E
REMOVE AND REPLACE EXISTING PITCH FROM PITCH POCKETAND REPAIR PITCH POCKET.
50
CF
1001FN
SECTION E
REMOVE EXISTING PIPE VENT FLASHING AND REPLACE WITH NEW LEAD PIPE VENT FLASHING.
50
EA
1001FP
SECTION F
REMOVE EXISTING ROOF HATCH AND REPLACE WITH NEW 2'-6" X 3'-6" ROOF HATCH WITH ALUMINUM CURB AND COVER.
14
EA
1001FQ
SECTION E
REMOVE EXISTING PIPE VENT FLASHING AND REPLACE WITH NEW GALV-NEOPRENE PIPE VENT FLASHING.
50
EA
1001FR
SECTION P
INSTALL NEW JOINT SEALANT.
3,000
LF
1001FS
SECTION P
REMOVE EXISTING JOINT SEALANT AND INSTALL NEW JOINT SEALANT.
2,600
LF
1001FT
SECTION Q
CUT NEW REGLET IN MASONRY.
300
LF
1001FU
SECTION Q
CUT NEW REGLET IN CONCRETE.
100
LF
1001FV
SECTION Q
REMOVE AND REINSTALL EXISTING ATTIC VENTILATORS.
17
EA
1001FW
SECTION E
REMOVE EXISTING ATTIC VENTILATORS AND REPLACE WITH NEW RESIDENTIAL OR COMMMERCIAL VENTILATORS.
50
LF
1001FX
SECTION U
REMOVE EXISTING RIDGE VENT AND REPLACE WITH NEW CONTINUOUS RIDGE VENT.
2,000
LF
1001FY
SECTION S

SECTION G

REMOVE EXISTING WOOD FASCIA AND REPLACE WITH NEW PAINTED WOOD FASCIA BOARD. (USE THIS ITEM FOR STANDARD-DIMENSIONED LUMBER.)
750
BF
1001GA
SECTION S

SECTION G

REMOVE EXISTING WOOD FASCIA AND REPLACE WITH NEW PAINTED WOOD FASCIA BOARD. (USE THIS ITEM FOR CUSTOM-MILLED LUMBER.)
150
BF

REMOVE EXISTING PRE-FORMED NON-STRUCTURAL METAL ROOFING AND REPLACE WITH

NEW PRE-FORMED NON-STRUCTURAL METAL ROOFING. – CLINS 1001 - - AND 1001

1001GB
SECTION H
COATED STEEL ROOFING.
50
SQ
1001GC
SECTION H
COATED ALUMINUM ROOFING.
50
SQ
1001GD
SECTION Q
DISCONNECT AND RECONNECT EXISTING ROOF-MOUNTED ELECTRICAL EQUIPMENT.
34
EA
SECTION Q
LABOR CHARGES FOR ROOF LEAK INVESTIGATION AND REPAIRS. (THIS ITEM TO BE USED WITH MATERIALS FOR ISOLATED MINOR ROOF LEAK REPAIRS.)
300
HR

CONSTRUCTION AIDS - CLINS 0001GE AND 0001GH

1001GE
SECTION A
PROVIDE FIXED STEEL TUBULAR SCAFFOLDING. (COST PER CSF OF BUILDING; ONE USE PER MONTH.)
34
CSF
1001GF
SECTION A
PROVIDE MOBILE SCAFFOLD. (COST FOR

40-FOOT AERIAL LIFT.)

34
MO
1001GG
SECTION A
SURVEY EXISTING ROOF SYSTEM AND PROVIDE A WRITTEN REPORT DETAILING EXISTING CONDITIONS AND REQUIRED MAINTENANCE.
34
SQ
1001GH
SECTION A
SURVEY EXISTING ROOF SYSTEM AND BUILDING STRUCTURE AND PROVIDE A WRITTEN REPORT DETAILING EXISTING STRUCTURAL CONDITIONS, LOAD CALCULATIONS & CAPABILITIES AND REQUIRED MAINTENANCE.
50
SQ

OPTION YEAR ONE ESTIMATED TOTAL( LINE ITEMS 1001AA THROUGH 1001GH)

File details come from the government source that posted it. Updated .