PRICING WORKSHEET- IFB# W91QF5-17-B-0001 OPTION YEAR THREE (3)

SPEC

ESTIMATED
UNIT
UNIT
ITEM
SECTION
DESCRIPTION
QUANTITY
MEASURE
PRICE

AMOUNT

OPTION YEAR THREE: 11 AUGUST 2020 THRU 10 AUGUST 2021. CONTRACTOR SHALL PROVIDE ALL LABOR, MATERIALS, EQUIPMENT, AND SUPERVISION REQUIRED TO REPAIR OR REPLACE ROOFING ON VARIOUS BUILDINGS LOCATED ON FORT LEE (PETERSBURG), VIRGINIA, IN ACCORDANCE WITH THE TERMS AND SPECIFICATIONS INCORPORATED HEREIN.

ROOF DECKS – CLINS 3001AA THRU 3001AH

3001AA
SECTION R
REMOVE EXISTING AND REPLACE WITH NEW STEEL ROOF DECKING, INCLUDES ALL CLOSURES AND ACCESSORIES.
35
SQ

REMOVE EXISTING WOOD ROOF DECK AND REPLACE WITH NEW WOOD ROOF DECKING. –

CLINS 3001AB THRU 3001AF

3001AB
SECTION R
1" NOMINAL TONGUE AND GROOVE WOOD DECK (TREATED).
300
BF
3001AC
SECTION S
2" NOMINAL TONGUE AND GROOVE WOOD DECK (TREATED).
200
BF
3001AD
SECTION S
3/4" EXTERIOR PLYWOOD (5 PLY).
100
SQ
3001AE
SECTION S
1/2" EXTERIOR PLYWOOD (5 PLY).
100
SQ
3001AF
SECTION Q
REMOVE AND DISPOSE OF EXISTING INSULATION, PER INCH OF DEPTH.
1,000
SQ

PARAPET WALL DAMPPROOFING – CLINS 3001AG AND 3001AH

3001AG
SECTION C
DAMPPROOFING FOR MINOR POROSITY.
100
SF
3001AH
SECTION C
DAMPPROOFING FOR SEVERE POROSITY.
200
SF

PROVIDE RIGID ROOF INSULATION IN CONJUNCTION WITH ROOFING SYSTEMS SPECIFIED. –

CLINS 3001AJ THRU 3001AS

3001AJ
SECTION T
1” THICK POLY-ISO BOARD.
250
SQ
3001AK
SECTION T
1-1/2” THICK POLY-ISO BOARD.
250
SQ
3001AL
SECTION T
2-1/2” THICK POLY-ISO BOARD.
200
SQ
3001AM
SECTION T
PROVIDE VAPOR BARRIER.
450
SQ
3001AN
SECTION T
PROVIDE RESIN-SIZED BUILDING PAPER (15 LB.).
200
SQ
3001AP
SECTION T
PROVIDE TAPERED ROOF INSULATION.
2500
BF
3001AQ
SECTION T
REMOVE EXISTING CANTS AND REPLACE WITH NEW 4" X 4" FIBERBOARD CANTS.
750
LF
3001AR
SECTION T
REMOVE EXISTING CANTS AND REPLACE WITH NEW 4" X 4" TREATED WOOD CANTS.
1,000
LF
3001AS
SECTION S
REMOVE EXISTING NAILERS AND REPLACE WITH NEW 2 X 6 TREATED WOOD NAILERS.
1,000
BF

SHINGLED ROOF SYSTEMS – CLINS 3001AT THRU 3001BC

3001AT
SECTION Q
REMOVE AND DISPOSE OF EXISTING ASPHALT SHINGLES.
1,100
SQ
3001AU
SECTION U
INSTALL NEW SELF-ADHERING MODIFIED BITUMEN UNDERLAYMENT.
2000
SF

PROVIDE NEW ASPHALT SHINGLES – CLINS 3001AV AND 3001AX

3001AV
SECTION U
CLASS A (25 YEAR) ASPHALT SHINGLES WITH A 60 MILE PER HOUR BASIC WIND SPEED WARRANTY.
200
SQ
3001AW
SECTION U
CLASS A (40 YEAR) ARCHITECTURAL ASPHALT SHINGLES WITH AN 80 MILE PER HOUR BASIC WIND SPEED WARRANTY.
150
SQ
3001AX
SECTION U
CLASS A (50 YEAR) ARCHITECTURAL ASPHALT SHINGLES WITH A 110 MILE PER HOUR BASIC WIND SPEED WARRANTY.
100
SQ
3001AY
SECTION Q
REMOVE AND DISPOSE OF EXISTING ROLL ROOFING.
75
SQ
3001AZ
SECTION U
INSTALL NEW ROLL ROOFING.
50
SQ

REMOVE EXISTING PRE-FORMED NON-STRUCTURAL METAL ROOFING AND REPLACE WITH

NEW PRE-FORMED NON-STRUCTURAL METAL ROOFING. – CLINS 3001BD AND 3001BE

3001BA
SECTION W
COATED STEEL ROOFING.
50
SQ
3001BB
SECTION W
COATED ALUMINUM ROOFING.
50
SQ
3001BC
SECTION I
COAT ROOFING WITH ALUMINUM PIGMENTED FIBERED BITUMEN ROOF COATING.
450
SQ

BUILT-UP ROOF SYSTEM – CLINS 3001BD THRU 3001BE

3001BD
SECTION D
FLOOD COAT AND GRAVEL EXISTING BUILT-UP ROOFING.
450
SQ
3001BE
SECTION X
REMOVE AND DISPOSE OF ASBESTOS-CONTAINING ROOFING AND FLASHING IN ACCORDANCE WITH ALL APPLICABLE FEDERAL, STATE AND LOCAL LAWS. INCLUDE ANY NECESSARY TEMPORARY “DRY IN” REQUIREMENTS.
250
SF

REMOVE EXISTING BUILT-UP ROOFING AND REPLACE WITH NEW AGGREGATE SURFACED BUILT-UP

ROOFING SYSTEM. – CLINS 3001BF THRU 3001BJ

3001BF
SECTION T
4-PLY BUILT-UP ROOF SYSTEM.
25
SQ
3001BG
SECTION T
5-PLY BUILT-UP ROOF SYSTEM.
15
SQ
3001BH
SECTION T
REMOVE EXISTING BASE FLASHING AND REPLACE WITH NEW 2-PLY BITUMINOUS BASE FLASHING.
1,000
SF
3001BJ
SECTION T
REMOVE EXISTING BASE FLASHING AND REPLACE WITH NEW 3-PLY BITUMINOUS BASE FLASHING.
1,000
SF

REMOVE EXISTING BUILT-UP ROOFING AND REPLACE WITH NEW SINGLE-PLY REINFORCED MODIFIED

BITUMEN SHEET ROOFING SYSTEM. – CLINS 3001BK THRU 3001BQ

3001BK
SECTION J
160 MIL, TORCH APPLIED ROOF SYSTEM.
100
SQ
3001BL
SECTION J
160 MIL, MOP APPLIED ROOF SYSTEM.
100
SQ
3001BM
SECTION J
REMOVE EXISTING BASE FLASHING AND REPLACE WITH NEW 160 MIL SINGLE-PLY REINFORCED MODIFIED BITUMEN BASE FLASHING.
1,500
SF
3001BN
SECTION J
REMOVE EXISTING BUILT-UP ROOFING AND REPLACE WITH NEW 180 MIL SINGLE-PLY REINFORCED MODIFIED BITUMEN ROOF SYSTEM.
150
SQ
3001BP
SECTION J
REMOVE EXISTING BASE FLASHING AND REPLACE WITH NEW 180 MIL SINGLE-PLY REINFORCED MODIFIED BITUMEN BASE FLASHING.
1,500
SF
3001BQ
SECTION J
INSTALL NEW ASPHALT WALKWAY OR ASPHALT PLANKS.
1,000
SF

CSPE (HYPALON) ROOF SYSTEMS – CLINS 3001BT AND 3001BU

3001BR
SECTION K
REMOVE EXISTING ROOF SYSTEM AND REPLACE WITH NEW MECHANICALLY FASTENED 60 MIL REINFORCED CSPE ROOF SYSTEM.
50
SQ
3001BS
SECTION K
REMOVE EXISTING ROOF SYSTEM AND REPLACE WITH NEW FULLY ADHERED 60 MIL REINFORCED CSPE ROOF SYSTEM.
50
SQ

EPDM ROOF SYSTEMS – CLINS 3001BV THRU 3001CD

3001BT
SECTION L
INSTALL NEW MECHANICALLY FASTENED 60 MIL REINFORCED EPDM ROOF SYSTEM OVER EXISTING BUILT-UP ROOF.
75
SQ
3001BU
SECTION L
INSTALL NEW FULLY ADHERED 60 MIL REINFORCED EPDM ROOF SYSTEM OVER EXISTING BUILT-UP ROOF.
75
SQ
3001BV
SECTION L
REMOVE EXISTING ROOF SYSTEM AND REPLACE WITH NEW BALLASTED 60 MIL REINFORCED EPDM ROOF SYSTEM.
50
SQ
3001BW
SECTION L
REMOVE EXISTING ROOF SYSTEM AND REPLACE WITH NEW MECHANICALLY FASTENED 60 MIL REINFORCED EPDM ROOF SYSTEM.
75
SQ
3001BX
SECTION L
REMOVE EXISTING ROOF SYSTEM AND REPLACE WITH NEW FULLY ADHERED EPDM 60 MIL REINFORCED ROOF SYSTEM.
75
SQ
3001BY
SECTION L
INSTALL NEW EPDM WALL AND CURB FLASHING.
1500
SF
3001BZ
SECTION L
INSTALL RUBBER PIPE VENTS.
67
EA
3001CA
SECTION E
INSTALL TERMINATION BARS.
1500
LF
3001CB
SECTION L
INSTALL WALKPADS.
1300
SF

CPA/PVC ROOF SYSTEMS – CLINS 3001CB AND 3001CC

3001CC
SECTION M
REMOVE EXISTING ROOF SYSTEM AND REPLACE WITH NEW MECHANICALLY FASTENED 60 MIL REINFORCED CPA/PVC ROOF SYSTEM.
50
SQ
3001CD
SECTION M
REMOVE EXISTING ROOF SYSTEM AND REPLACE WITH NEW FULLY ADHERED 60 MIL REINFORCED CPA/PVC ROOF SYSTEM.
50
SQ

TPO ROOF SYSTEMS – CLINS 3001CG AND 3001CH

3001CE
SECTION N
REMOVE EXISTING ROOF SYSTEM AND REPLACE WITH NEW MECHANICALLY FASTENED 60 MIL REINFORCED TPO ROOF SYSTEM.
50
SQ
3001CF
SECTION N
REMOVE EXISTING ROOF SYSTEM AND REPLACE WITH NEW FULLY ADHERED 60 MIL REINFORCED TPO ROOF SYSTEM.
50
SQ

ELASTOMERIC ROOF COATINGS OVER POLYURETHANE FOAM (SPF) – CLINS 3001CJ AND 3001CK

3001CG
SECTION O
INSTALL NEW POLYURETHANE FOAM INSULATION, PER INCH OF DEPTH, INCLUDING PREPARATION OF ROOF DECK OR EXISTING INSULATION TO REMAIN.
125
SQ
3001CH
SECTION O
INSTALL NEW ELASTOMERIC ROOF COATING, INCLUDING PREPARATION OF ROOF DECK, NEW INSULATION OR EXISTING INSULATION TO REMAIN.
75
SQ

REMOVE EXISTING SHEETMETAL ITEMS AND REPLACE WITH NEW SHEETMETAL ITEMS. –

CLINS 3001CL THRU 3001ES

3001CJ
SECTION E
REMOVE EXISTING METAL BASE FLASHING AND REPLACE WITH NEW ALUMINUM BASE FLASHING.
250
SF
3001CK
SECTION E
REMOVE EXISTING METAL BASE FLASHING AND REPLACE WITH NEW COPPER BASE FLASHING.
150
SF
3001CL
SECTION E
REMOVE EXISTING METAL BASE FLASHING AND REPLACE WITH NEW STAINLESS STEEL BASE FLASHING.
50
SF
3001CM
SECTION E
REMOVE EXISTING METAL BASE FLASHING AND REPLACE WITH NEW ALUMINUM STEP FLASHING.
500
SF
3001CN
SECTION E
REMOVE EXISTING METAL BASE FLASHING AND REPLACE WITH NEW COPPER STEP FLASHING.
200
SF
3001CP
SECTION E
REMOVE EXISTING METAL BASE FLASHING AND REPLACE WITH NEW STAINLESS STEEL STEP FLASHING.
100
SF
3001CQ
SECTION E
REMOVE EXISTING METAL COUNTER-FLASHING AND REPLACE WITH NEW ALUMINUM COUNTERFLASHING.
750
LF
3001CR
SECTION E
REMOVE EXISTING METAL COUNTER-FLASHING AND REPLACE WITH NEW COPPER COUNTERFLASHING.
40
LF
3001CS
SECTION E
REMOVE EXISTING METAL COUNTER-FLASHING AND REPLACE WITH NEW STAINLESS STEEL COUNTERFLASHING.
80
LF
3001CT
SECTION E
REMOVE EXISTING METAL GRAVELSTOP AND REPLACE WITH NEW ALUMINUM GRAVELSTOP (UP TO 6" HIGH).
40
LF
3001CU
SECTION E
REMOVE EXISTING METAL GRAVELSTOP AND REPLACE WITH NEW ANODIZED ALUMINUM GRAVELSTOP (UP TO 6" HIGH).
500
LF
3001CV
SECTION E
REMOVE EXISTING METAL GRAVELSTOP AND REPLACE WITH NEW COPPER GRAVELSTOP (UP TO 6" HIGH).
40
LF
3001CW
SECTION E
REMOVE EXISTING METAL GRAVELSTOP AND REPLACE WITH NEW STAINLESS STEEL GRAVELSTOP (UP TO 6"HIGH).
40
LF
3001CX
SECTION E
REMOVE EXISTING METAL GRAVELSTOP AND REPLACE WITH NEW ALUMINUM GRAVELSTOP (6" TO 12" HIGH).
50
LF
3001CY
SECTION E
REMOVE EXISTING METAL GRAVELSTOP AND REPLACE WITH NEW ANODIZED ALUMINUM GRAVELSTOP (6" TO 12" HIGH).
100
LF
3001CZ
SECTION E
REMOVE EXISTING METAL GRAVELSTOP AND REPLACE WITH NEW COPPER GRAVELSTOP (6" TO 12" HIGH).
50
LF
3001DA
SECTION E
REMOVE EXISTING METAL GRAVELSTOP AND REPLACE WITH NEW STAINLESS STEEL GRAVELSTOP (6" TO 12" HIGH).
250
LF
3001DB
SECTION E
REMOVE EXISTING METAL DRIP EDGE AND REPLACE WITH NEW ALUMINUM DRIP EDGE.
4,000
LF
3001DC
SECTION E
REMOVE EXISTING METAL DRIP EDGE AND REPLACE WITH NEW COPPER DRIP EDGE.
75
LF
3001DD
SECTION E
REMOVE EXISTING METAL DRIP EDGE AND REPLACE WITH NEW STAINLESS STEEL DRIP EDGE.
150
LF
3001DE
SECTION E
REMOVE EXISTING OPEN VALLEY FLASHING AND REPLACE WITH NEW ALUMINUM OPEN VALLEY FLASHING.
300
SF
3001DF
SECTION E
REMOVE EXISTING OPEN VALLEY FLASHING AND REPLACE WITH NEW COPPER OPEN VALLEY FLASHING.
150
SF
3001DG
SECTION E
REMOVE EXISTING OPEN VALLEY FLASHING AND REPLACE WITH NEW STAINLESS STEEL OPEN VALLEY FLASHING.
150
SF
3001DH
SECTION E
REMOVE EXISTING METAL COPING AND REPLACE WITH NEW ALUMINUM COPING.
300
SF
3001DJ
SECTION E
REMOVE EXISTING METAL COPING AND REPLACE WITH NEW COPPER COPING.
200
SF
3001DK
SECTION E
REMOVE EXISTING METAL COPING AND REPLACE WITH NEW STAINLESS STEEL COPING.
300
SF
3001DL
SECTION E
REMOVE EXISTING METAL EXPANSION JOINTS AND REPLACE WITH NEW ALUMINUM EXPANSION JOINTS.
300
SF
3001DM
SECTION E
REMOVE EXISTING METAL EXPANSION JOINTS AND REPLACE WITH NEW COPPER EXPANSION JOINTS.
50
SF
3001DN
SECTION E
REMOVE EXISTING METAL EXPANSION JOINTS AND REPLACE WITH NEW STAINLESS STEEL EXPANSION JOINTS.
67
SF
3001DP
SECTION E
REMOVE EXISTING FLASHING WITH MISCELLANEOUS SHAPES AND REPLACE WITH NEW ALUMINUM FLASHING.
450
SF
3001DQ
SECTION E
REMOVE EXISTING FLASHING WITH MISCELLANEOUS SHAPES AND REPLACE WITH NEW COPPER FLASHING.
250
SF
3001DR
SECTION E
REMOVE EXISTING FLASHING WITH MISCELLANEOUS SHAPES AND REPLACE WITH NEW STAINLESS STEEL FLASHING.
150
SF
3001DS
SECTION E
INSTALL NEW 5-INCH WIDE PRE-FINISHED ALUMINUM OGEE GUTTERS.
650
LF
3001DT
SECTION E
INSTALL NEW 6-INCH WIDE PRE-FINISHED ALUMINUM OGEE GUTTERS.
650
LF
3001DU
SECTION E
INSTALL NEW 6-INCH WIDE COPPER BOX GUTTERS.
500
LF
3001DV
SECTION E
INSTALL NEW 8-INCH WIDE COPPER BOX GUTTERS.
30
LF
3001DW
SECTION E
INSTALL NEW 5-INCH WIDE COPPER HALF ROUND GUTTERS.
150
LF
3001DX
SECTION E
INSTALL NEW 6-INCH WIDE COPPER HALF ROUND GUTTERS.
100
LF
3001DY
SECTION E
INSTALL NEW 5-INCH WIDE COPPER OGEE GUTTERS.
150
LF
3001DZ
SECTION E
INSTALL NEW 6-INCH WIDE COPPER OGEE GUTTERS.
150
LF
3001EA
SECTION E
INSTALL NEW 6-INCH WIDE STAINLESS STEEL BOX GUTTERS.
250
LF
3001EB
SECTION E
INSTALL NEW 2-1/4" X 3-1/4" PRE-FINISHED ALUMINUM DOWNSPOUTS.
300
LF
3001EC
SECTION E
INSTALL NEW 3" X 4" PREFINISHED ALUMINUM DOWNSPOUTS.
1,000
LF
3001ED
SECTION E
INSTALL NEW 2-1/4" X 3-1/4" COPPER DOWNSPOUTS.
250
LF
3001EE
SECTION E
INSTALL NEW 3" X 4" COPPER DOWNSPOUTS.
500
LF
3001EF
SECTION E
INSTALL NEW 3" ROUND COPPER DOWNSPOUTS.
100
LF
3001EG
SECTION E
INSTALL NEW 4" ROUND COPPER DOWNSPOUTS.
250
LF
3001EH
SECTION E
INSTALL NEW 6" ROUND COPPER DOWNSPOUTS.
200
LF
3001EJ
SECTION E
INSTALL NEW 3" X 4" STAINLESS STEEL DOWNSPOUTS.
250
LF
3001EK
SECTION E
REMOVE EXISTING METAL CONDUCTOR HEADS AND REPLACE WITH NEW COPPER CONDUCTOR HEADS.
30
SF
3001EL
SECTION E
REMOVE EXISTING METAL CONDUCTOR HEADS AND REPLACE WITH NEW STAINLESS STEEL CONDUCTOR HEADS.
30
SF
3001EM
SECTION E
REMOVE EXISTING METAL SCUPPER LINING AND REPLACE WITH NEW COPPER SCUPPER LINING.
30
SF
3001EN
SECTION E
REMOVE EXISTING METAL SCUPPER LINING AND REPLACE WITH NEW STAINLESS STEEL SCUPPER LINING.
30
SF
3001EP
SECTION E
REMOVE AND REINSTALL EXISTING GUTTERS AND DOWNSPOUTS.
150
LF
3001EQ
SECTION E
REALIGN AND RESECURE EXISTING GUTTERS AND DOWNSPOUTS, INCLUDES ALL NEW HARDWARE.
3,000
LF
3001ER
SECTION E
REMOVE AND DISPOSE OF EXISTING GUTTERS AND DOWNSPOUTS.
7,000
LF
3001ES
SECTION E
RESOLDER GUTTER JOINTS.
50
EA
3001ET
SECTION P
REPAIR BROKEN GUTTER JOINTS WITH SEALANT.
50
EA
3001EU
SECTION Q
CLEAN AND DISPOSE OF DEBRIS IN GUTTERS.
$3,500
LF
3001EV
-- -- --
INSTALL NEW COMMERCIAL-SIZED CONCRETE SPLASHBLOCKS.
50
EA
3001EW
SECTION E
INSTALL NEW COPPER SPLASHPANS.
10
EA
3001EX
SECTION E
INSTALL NEW STAINLESS STEEL SPLASHPANS.
10
EA
3001EY
SECTION Q
CLEAN AND CLEAR ROOF DRAINS.
50
EA
3001EZ
SECTION E
REMOVE EXISTING ROOF DRAIN SUMPS AND REPLACE WITH NEW 6-POUND LEAD DRAIN SUMPS (24" X 24" WITH 4"FLANGE).
30
EA
3001FA
-- -- --
REMOVE EXISTING ROOF DRAIN SUMPS AND REPLACE WITH NEW PVC DRAIN SUMPS (24" X 24" WITH 4"FLANGE).
17
EA
3001FB
SECTION Q
REMOVE EXISTING ROOF DRAIN STRAINERS AND REPLACE WITH NEW METAL ROOF DRAIN STRAINERS.
10
EA
3001FC
SECTION Q
REMOVE EXISTING ROOF DRAIN STRAINERS AND REPLACE WITH NEW POLY (VINYL CHLORIDE) (PVC) ROOF DRAIN STRAINERS.
10
EA

REMOVE EXISTING ROOF DRAIN AND REPLACE WITH NEW ROOF DRAIN, JOSAN 22010 SERIES,

COATED CAST IRON, OR EQUAL, WITH METAL STRAINER AND INCLUDING ALL ACCESSORIES

AND FLASHINGS. – CLINS 3001FF THRU 3001FL

3001FD
-- -- --
3-INCH DIAMETER ROOF DRAIN.
7
EA
3001FE
-- -- --
4-INCH DIAMETER ROOF DRAIN.
10
EA
3001FF
-- -- --
6-INCH DIAMETER ROOF DRAIN.
7
EA
3001FG
-- -- --
REMOVE EXISTING DRAIN PIPE WITH AND REPLACE WITH NEW 3" DIAMETER SCHEDULE 40 PVC DRAIN PIPE, INCLUDING ELBOWS, COUPLINGS, ETC.
150
LF
3001FH
-- -- --
REMOVE EXISTING DRAIN PIPE WITH AND REPLACE WITH NEW 4" DIAMETER SCHEDULE 40 PVC DRAIN PIPE, INCLUDING ELBOWS, COUPLINGS, ETC.
300
LF
3001FJ
-- -- --
REMOVE EXISTING DRAIN PIPE WITH AND REPLACE WITH NEW 6" DIAMETER SCHEDULE 40 PVC DRAIN PIPE, INCLUDING ELBOWS, COUPLINGS, ETC.
150
LF
3001FK
SECTION E
REMOVE EXISTING PITCH POCKET AND REPLACE WITH NEW COPPER PITCH POCKET, INCLUDING NAILERS, FLASHING, COUNTERFLASHING, METAL JOINT

COVER, ETC.

75
EA
3001FL
SECTION E
REMOVE EXISTING PITCH POCKET AND REPLACE WITH NEW STAINLESS STEEL PITCH POCKET, INCLUDING NAILERS, FLASHING, COUNTERFLASHING, METAL JOINT COVER, ETC.
75
EA
3001FM
SECTION E
REMOVE AND REPLACE EXISTING PITCH FROM PITCH POCKETAND REPAIR PITCH POCKET.
50
CF
3001FN
SECTION E
REMOVE EXISTING PIPE VENT FLASHING AND REPLACE WITH NEW LEAD PIPE VENT FLASHING.
50
EA
3001FP
SECTION F
REMOVE EXISTING ROOF HATCH AND REPLACE WITH NEW 2'-6" X 3'-6" ROOF HATCH WITH ALUMINUM CURB AND COVER.
14
EA
3001FQ
SECTION E
REMOVE EXISTING PIPE VENT FLASHING AND REPLACE WITH NEW GALV-NEOPRENE PIPE VENT FLASHING.
50
EA
3001FR
SECTION P
INSTALL NEW JOINT SEALANT.
3,000
LF
3001FS
SECTION P
REMOVE EXISTING JOINT SEALANT AND INSTALL NEW JOINT SEALANT.
2,600
LF
3001FT
SECTION Q
CUT NEW REGLET IN MASONRY.
300
LF
3001FU
SECTION Q
CUT NEW REGLET IN CONCRETE.
100
LF
3001FV
SECTION Q
REMOVE AND REINSTALL EXISTING ATTIC VENTILATORS.
17
EA
3001FW
SECTION E
REMOVE EXISTING ATTIC VENTILATORS AND REPLACE WITH NEW RESIDENTIAL OR COMMMERCIAL VENTILATORS.
50
LF
3001FX
SECTION U
REMOVE EXISTING RIDGE VENT AND REPLACE WITH NEW CONTINUOUS RIDGE VENT.
2,000
LF
3001FY
SECTION S

SECTION G

REMOVE EXISTING WOOD FASCIA AND REPLACE WITH NEW PAINTED WOOD FASCIA BOARD. (USE THIS ITEM FOR STANDARD-DIMENSIONED LUMBER.)
750
BF
3001GA
SECTION S

SECTION G

REMOVE EXISTING WOOD FASCIA AND REPLACE WITH NEW PAINTED WOOD FASCIA BOARD. (USE THIS ITEM FOR CUSTOM-MILLED LUMBER.)
150
BF

REMOVE EXISTING PRE-FORMED NON-STRUCTURAL METAL ROOFING AND REPLACE WITH

NEW PRE-FORMED NON-STRUCTURAL METAL ROOFING. – CLINS 3001 - - AND 3001 - -

3001GB
SECTION H
COATED STEEL ROOFING.
50
SQ
3001GC
SECTION H
COATED ALUMINUM ROOFING.
50
SQ
3001GD
SECTION Q
DISCONNECT AND RECONNECT EXISTING ROOF-MOUNTED ELECTRICAL EQUIPMENT.
34
EA
SECTION Q
LABOR CHARGES FOR ROOF LEAK INVESTIGATION AND REPAIRS. (THIS ITEM TO BE USED WITH MATERIALS FOR ISOLATED MINOR ROOF LEAK REPAIRS.)
300
HR

CONSTRUCTION AIDS - CLINS 3001GE AND 3001GH

3001GE
SECTION A
PROVIDE FIXED STEEL TUBULAR SCAFFOLDING. (COST PER CSF OF BUILDING; ONE USE PER MONTH.)
34
CSF
3001GF
SECTION A
PROVIDE MOBILE SCAFFOLD. (COST FOR

40-FOOT AERIAL LIFT.)

34
MO
3001GG
SECTION A
SURVEY EXISTING ROOF SYSTEM AND PROVIDE A WRITTEN REPORT DETAILING EXISTING CONDITIONS AND REQUIRED MAINTENANCE.
34
SQ
3001GH
SECTION A
SURVEY EXISTING ROOF SYSTEM AND BUILDING STRUCTURE AND PROVIDE A WRITTEN REPORT DETAILING EXISTING STRUCTURAL CONDITIONS, LOAD CALCULATIONS & CAPABILITIES AND REQUIRED MAINTENANCE.
50
SQ

OPTION YEAR THREE: ESTIMATED TOTAL ( LINE ITEMS 3001AA THROUGH 3001GH)