PRICING WORKSHEET- IFB# W91QF5-17-B-0001 OPTION YEAR FOUR (4)

SPEC

ESTIMATED
UNIT
UNIT
ITEM
SECTION
DESCRIPTION
QUANTITY
MEASURE
PRICE

AMOUNT

OPTION YEAR FOUR: 11 AUGUST 2021 THRU 10 AUGUST 2022. CONTRACTOR SHALL PROVIDE ALL LABOR, MATERIALS, EQUIPMENT, AND SUPERVISION REQUIRED TO REPAIR OR REPLACE ROOFING ON VARIOUS BUILDINGS LOCATED ON FORT LEE (PETERSBURG), VIRGINIA, IN ACCORDANCE WITH THE TERMS AND SPECIFICATIONS INCORPORATED HEREIN.

ROOF DECKS – CLINS 4001AA THRU 4001AH

4001AA
SECTION R
REMOVE EXISTING AND REPLACE WITH NEW STEEL ROOF DECKING, INCLUDES ALL CLOSURES AND ACCESSORIES.
35
SQ

REMOVE EXISTING WOOD ROOF DECK AND REPLACE WITH NEW WOOD ROOF DECKING. –

CLINS 4001AB THRU 4001AF

4001AB
SECTION R
1" NOMINAL TONGUE AND GROOVE WOOD DECK (TREATED).
300
BF
4001AC
SECTION S
2" NOMINAL TONGUE AND GROOVE WOOD DECK (TREATED).
200
BF
4001AD
SECTION S
3/4" EXTERIOR PLYWOOD (5 PLY).
100
SQ
4001AE
SECTION S
1/2" EXTERIOR PLYWOOD (5 PLY).
100
SQ
4001AF
SECTION Q
REMOVE AND DISPOSE OF EXISTING INSULATION, PER INCH OF DEPTH.
1,000
SQ

PARAPET WALL DAMPPROOFING – CLINS 4001AG AND 4001AH

4001AG
SECTION C
DAMPPROOFING FOR MINOR POROSITY.
100
SF
4001AH
SECTION C
DAMPPROOFING FOR SEVERE POROSITY.
200
SF

PROVIDE RIGID ROOF INSULATION IN CONJUNCTION WITH ROOFING SYSTEMS SPECIFIED. –

CLINS 4001AJ THRU 4001AS

4001AJ
SECTION T
1” THICK POLY-ISO BOARD.
250
SQ
4001AK
SECTION T
1-1/2” THICK POLY-ISO BOARD.
250
SQ
4001AL
SECTION T
2-1/2” THICK POLY-ISO BOARD.
200
SQ
4001AM
SECTION T
PROVIDE VAPOR BARRIER.
450
SQ
4001AN
SECTION T
PROVIDE RESIN-SIZED BUILDING PAPER (15 LB.).
200
SQ
4001AP
SECTION T
PROVIDE TAPERED ROOF INSULATION.
2500
BF
4001AQ
SECTION T
REMOVE EXISTING CANTS AND REPLACE WITH NEW 4" X 4" FIBERBOARD CANTS.
750
LF
4001AR
SECTION T
REMOVE EXISTING CANTS AND REPLACE WITH NEW 4" X 4" TREATED WOOD CANTS.
1,000
LF
4001AS
SECTION S
REMOVE EXISTING NAILERS AND REPLACE WITH NEW 2 X 6 TREATED WOOD NAILERS.
1,000
BF

SHINGLED ROOF SYSTEMS – CLINS 4001AT THRU 4001BC

4001AT
SECTION Q
REMOVE AND DISPOSE OF EXISTING ASPHALT SHINGLES.
1,100
SQ
4001AU
SECTION U
INSTALL NEW SELF-ADHERING MODIFIED BITUMEN UNDERLAYMENT.
2000
SF

PROVIDE NEW ASPHALT SHINGLES – CLINS 4001AV AND 4001AX

4001AV
SECTION U
CLASS A (25 YEAR) ASPHALT SHINGLES WITH A 60 MILE PER HOUR BASIC WIND SPEED WARRANTY.
200
SQ
4001AW
SECTION U
CLASS A (40 YEAR) ARCHITECTURAL ASPHALT SHINGLES WITH AN 80 MILE PER HOUR BASIC WIND SPEED WARRANTY.
150
SQ
4001AX
SECTION U
CLASS A (50 YEAR) ARCHITECTURAL ASPHALT SHINGLES WITH A 110 MILE PER HOUR BASIC WIND SPEED WARRANTY.
100
SQ
4001AY
SECTION Q
REMOVE AND DISPOSE OF EXISTING ROLL ROOFING.
75
SQ
4001AZ
SECTION U
INSTALL NEW ROLL ROOFING.
50
SQ

REMOVE EXISTING PRE-FORMED NON-STRUCTURAL METAL ROOFING AND REPLACE WITH

NEW PRE-FORMED NON-STRUCTURAL METAL ROOFING. – CLINS 4001BD AND 4001BE

4001BA
SECTION W
COATED STEEL ROOFING.
50
SQ
4001BB
SECTION W
COATED ALUMINUM ROOFING.
50
SQ
4001BC
SECTION I
COAT ROOFING WITH ALUMINUM PIGMENTED FIBERED BITUMEN ROOF COATING.
450
SQ

BUILT-UP ROOF SYSTEM – CLINS 4001BD THRU 4001BE

4001BD
SECTION D
FLOOD COAT AND GRAVEL EXISTING BUILT-UP ROOFING.
450
SQ
4001BE
SECTION X
REMOVE AND DISPOSE OF ASBESTOS-CONTAINING ROOFING AND FLASHING IN ACCORDANCE WITH ALL APPLICABLE FEDERAL, STATE AND LOCAL LAWS. INCLUDE ANY NECESSARY TEMPORARY “DRY IN” REQUIREMENTS.
250
SF

REMOVE EXISTING BUILT-UP ROOFING AND REPLACE WITH NEW AGGREGATE SURFACED BUILT-UP

ROOFING SYSTEM. – CLINS 4001BF THRU 4001BJ

4001BF
SECTION T
4-PLY BUILT-UP ROOF SYSTEM.
25
SQ
4001BG
SECTION T
5-PLY BUILT-UP ROOF SYSTEM.
15
SQ
4001BH
SECTION T
REMOVE EXISTING BASE FLASHING AND REPLACE WITH NEW 2-PLY BITUMINOUS BASE FLASHING.
1,000
SF
4001BJ
SECTION T
REMOVE EXISTING BASE FLASHING AND REPLACE WITH NEW 3-PLY BITUMINOUS BASE FLASHING.
1,000
SF

REMOVE EXISTING BUILT-UP ROOFING AND REPLACE WITH NEW SINGLE-PLY REINFORCED MODIFIED

BITUMEN SHEET ROOFING SYSTEM. – CLINS 4001BK THRU 4001BQ

4001BK
SECTION J
160 MIL, TORCH APPLIED ROOF SYSTEM.
100
SQ
4001BL
SECTION J
160 MIL, MOP APPLIED ROOF SYSTEM.
100
SQ
4001BM
SECTION J
REMOVE EXISTING BASE FLASHING AND REPLACE WITH NEW 160 MIL SINGLE-PLY REINFORCED MODIFIED BITUMEN BASE FLASHING.
1,500
SF
4001BN
SECTION J
REMOVE EXISTING BUILT-UP ROOFING AND REPLACE WITH NEW 180 MIL SINGLE-PLY REINFORCED MODIFIED BITUMEN ROOF SYSTEM.
150
SQ
4001BP
SECTION J
REMOVE EXISTING BASE FLASHING AND REPLACE WITH NEW 180 MIL SINGLE-PLY REINFORCED MODIFIED BITUMEN BASE FLASHING.
1,500
SF
4001BQ
SECTION J
INSTALL NEW ASPHALT WALKWAY OR ASPHALT PLANKS.
1,000
SF

CSPE (HYPALON) ROOF SYSTEMS – CLINS 4001BT AND 4001BU

4001BR
SECTION K
REMOVE EXISTING ROOF SYSTEM AND REPLACE WITH NEW MECHANICALLY FASTENED 60 MIL REINFORCED CSPE ROOF SYSTEM.
50
SQ
4001BS
SECTION K
REMOVE EXISTING ROOF SYSTEM AND REPLACE WITH NEW FULLY ADHERED 60 MIL REINFORCED CSPE ROOF SYSTEM.
50
SQ

EPDM ROOF SYSTEMS – CLINS 0001BV THRU 0001CD

4001BT
SECTION L
INSTALL NEW MECHANICALLY FASTENED 60 MIL REINFORCED EPDM ROOF SYSTEM OVER EXISTING BUILT-UP ROOF.
75
SQ
4001BU
SECTION L
INSTALL NEW FULLY ADHERED 60 MIL REINFORCED EPDM ROOF SYSTEM OVER EXISTING BUILT-UP ROOF.
75
SQ
4001BV
SECTION L
REMOVE EXISTING ROOF SYSTEM AND REPLACE WITH NEW BALLASTED 60 MIL REINFORCED EPDM ROOF SYSTEM.
50
SQ
4001BW
SECTION L
REMOVE EXISTING ROOF SYSTEM AND REPLACE WITH NEW MECHANICALLY FASTENED 60 MIL REINFORCED EPDM ROOF SYSTEM.
75
SQ
4001BX
SECTION L
REMOVE EXISTING ROOF SYSTEM AND REPLACE WITH NEW FULLY ADHERED EPDM 60 MIL REINFORCED ROOF SYSTEM.
75
SQ
4001BY
SECTION L
INSTALL NEW EPDM WALL AND CURB FLASHING.
1500
SF
4001BZ
SECTION L
INSTALL RUBBER PIPE VENTS.
67
EA
4001CA
SECTION E
INSTALL TERMINATION BARS.
1500
LF
4001CB
SECTION L
INSTALL WALKPADS.
1300
SF

CPA/PVC ROOF SYSTEMS – CLINS 4001CB AND 4001CC

4001CC
SECTION M
REMOVE EXISTING ROOF SYSTEM AND REPLACE WITH NEW MECHANICALLY FASTENED 60 MIL REINFORCED CPA/PVC ROOF SYSTEM.
50
SQ
4001CD
SECTION M
REMOVE EXISTING ROOF SYSTEM AND REPLACE WITH NEW FULLY ADHERED 60 MIL REINFORCED CPA/PVC ROOF SYSTEM.
50
SQ

TPO ROOF SYSTEMS – CLINS 4001CG AND 4001CH

4001CE
SECTION N
REMOVE EXISTING ROOF SYSTEM AND REPLACE WITH NEW MECHANICALLY FASTENED 60 MIL REINFORCED TPO ROOF SYSTEM.
50
SQ
4001CF
SECTION N
REMOVE EXISTING ROOF SYSTEM AND REPLACE WITH NEW FULLY ADHERED 60 MIL REINFORCED TPO ROOF SYSTEM.
50
SQ

ELASTOMERIC ROOF COATINGS OVER POLYURETHANE FOAM (SPF) – CLINS 4001CJ AND 4001CK

4001CG
SECTION O
INSTALL NEW POLYURETHANE FOAM INSULATION, PER INCH OF DEPTH, INCLUDING PREPARATION OF ROOF DECK OR EXISTING INSULATION TO REMAIN.
125
SQ
4001CH
SECTION O
INSTALL NEW ELASTOMERIC ROOF COATING, INCLUDING PREPARATION OF ROOF DECK, NEW INSULATION OR EXISTING INSULATION TO REMAIN.
75
SQ

REMOVE EXISTING SHEETMETAL ITEMS AND REPLACE WITH NEW SHEETMETAL ITEMS. –

CLINS 4001CL THRU 4001ES

4001CJ
SECTION E
REMOVE EXISTING METAL BASE FLASHING AND REPLACE WITH NEW ALUMINUM BASE FLASHING.
250
SF
4001CK
SECTION E
REMOVE EXISTING METAL BASE FLASHING AND REPLACE WITH NEW COPPER BASE FLASHING.
150
SF
4001CL
SECTION E
REMOVE EXISTING METAL BASE FLASHING AND REPLACE WITH NEW STAINLESS STEEL BASE FLASHING.
50
SF
4001CM
SECTION E
REMOVE EXISTING METAL BASE FLASHING AND REPLACE WITH NEW ALUMINUM STEP FLASHING.
500
SF
4001CN
SECTION E
REMOVE EXISTING METAL BASE FLASHING AND REPLACE WITH NEW COPPER STEP FLASHING.
200
SF
4001CP
SECTION E
REMOVE EXISTING METAL BASE FLASHING AND REPLACE WITH NEW STAINLESS STEEL STEP FLASHING.
100
SF
4001CQ
SECTION E
REMOVE EXISTING METAL COUNTER-FLASHING AND REPLACE WITH NEW ALUMINUM COUNTERFLASHING.
750
LF
4001CR
SECTION E
REMOVE EXISTING METAL COUNTER-FLASHING AND REPLACE WITH NEW COPPER COUNTERFLASHING.
40
LF
4001CS
SECTION E
REMOVE EXISTING METAL COUNTER-FLASHING AND REPLACE WITH NEW STAINLESS STEEL COUNTERFLASHING.
80
LF
4001CT
SECTION E
REMOVE EXISTING METAL GRAVELSTOP AND REPLACE WITH NEW ALUMINUM GRAVELSTOP (UP TO 6" HIGH).
40
LF
4001CU
SECTION E
REMOVE EXISTING METAL GRAVELSTOP AND REPLACE WITH NEW ANODIZED ALUMINUM GRAVELSTOP (UP TO 6" HIGH).
500
LF
4001CV
SECTION E
REMOVE EXISTING METAL GRAVELSTOP AND REPLACE WITH NEW COPPER GRAVELSTOP (UP TO 6" HIGH).
40
LF
4001CW
SECTION E
REMOVE EXISTING METAL GRAVELSTOP AND REPLACE WITH NEW STAINLESS STEEL GRAVELSTOP (UP TO 6"HIGH).
40
LF
4001CX
SECTION E
REMOVE EXISTING METAL GRAVELSTOP AND REPLACE WITH NEW ALUMINUM GRAVELSTOP (6" TO 12" HIGH).
50
LF
4001CY
SECTION E
REMOVE EXISTING METAL GRAVELSTOP AND REPLACE WITH NEW ANODIZED ALUMINUM GRAVELSTOP (6" TO 12" HIGH).
100
LF
4001CZ
SECTION E
REMOVE EXISTING METAL GRAVELSTOP AND REPLACE WITH NEW COPPER GRAVELSTOP (6" TO 12" HIGH).
50
LF
4001DA
SECTION E
REMOVE EXISTING METAL GRAVELSTOP AND REPLACE WITH NEW STAINLESS STEEL GRAVELSTOP (6" TO 12" HIGH).
250
LF
4001DB
SECTION E
REMOVE EXISTING METAL DRIP EDGE AND REPLACE WITH NEW ALUMINUM DRIP EDGE.
4,000
LF
4001DC
SECTION E
REMOVE EXISTING METAL DRIP EDGE AND REPLACE WITH NEW COPPER DRIP EDGE.
75
LF
4001DD
SECTION E
REMOVE EXISTING METAL DRIP EDGE AND REPLACE WITH NEW STAINLESS STEEL DRIP EDGE.
150
LF
4001DE
SECTION E
REMOVE EXISTING OPEN VALLEY FLASHING AND REPLACE WITH NEW ALUMINUM OPEN VALLEY FLASHING.
300
SF
4001DF
SECTION E
REMOVE EXISTING OPEN VALLEY FLASHING AND REPLACE WITH NEW COPPER OPEN VALLEY FLASHING.
150
SF
4001DG
SECTION E
REMOVE EXISTING OPEN VALLEY FLASHING AND REPLACE WITH NEW STAINLESS STEEL OPEN VALLEY FLASHING.
150
SF
4001DH
SECTION E
REMOVE EXISTING METAL COPING AND REPLACE WITH NEW ALUMINUM COPING.
300
SF
4001DJ
SECTION E
REMOVE EXISTING METAL COPING AND REPLACE WITH NEW COPPER COPING.
200
SF
4001DK
SECTION E
REMOVE EXISTING METAL COPING AND REPLACE WITH NEW STAINLESS STEEL COPING.
300
SF
4001DL
SECTION E
REMOVE EXISTING METAL EXPANSION JOINTS AND REPLACE WITH NEW ALUMINUM EXPANSION JOINTS.
300
SF
4001DM
SECTION E
REMOVE EXISTING METAL EXPANSION JOINTS AND REPLACE WITH NEW COPPER EXPANSION JOINTS.
50
SF
4001DN
SECTION E
REMOVE EXISTING METAL EXPANSION JOINTS AND REPLACE WITH NEW STAINLESS STEEL EXPANSION JOINTS.
67
SF
4001DP
SECTION E
REMOVE EXISTING FLASHING WITH MISCELLANEOUS SHAPES AND REPLACE WITH NEW ALUMINUM FLASHING.
450
SF
4001DQ
SECTION E
REMOVE EXISTING FLASHING WITH MISCELLANEOUS SHAPES AND REPLACE WITH NEW COPPER FLASHING.
250
SF
4001DR
SECTION E
REMOVE EXISTING FLASHING WITH MISCELLANEOUS SHAPES AND REPLACE WITH NEW STAINLESS STEEL FLASHING.
150
SF
4001DS
SECTION E
INSTALL NEW 5-INCH WIDE PRE-FINISHED ALUMINUM OGEE GUTTERS.
650
LF
4001DT
SECTION E
INSTALL NEW 6-INCH WIDE PRE-FINISHED ALUMINUM OGEE GUTTERS.
650
LF
4001DU
SECTION E
INSTALL NEW 6-INCH WIDE COPPER BOX GUTTERS.
500
LF
4001DV
SECTION E
INSTALL NEW 8-INCH WIDE COPPER BOX GUTTERS.
30
LF
4001DW
SECTION E
INSTALL NEW 5-INCH WIDE COPPER HALF ROUND GUTTERS.
150
LF
4001DX
SECTION E
INSTALL NEW 6-INCH WIDE COPPER HALF ROUND GUTTERS.
100
LF
4001DY
SECTION E
INSTALL NEW 5-INCH WIDE COPPER OGEE GUTTERS.
150
LF
4001DZ
SECTION E
INSTALL NEW 6-INCH WIDE COPPER OGEE GUTTERS.
150
LF
4001EA
SECTION E
INSTALL NEW 6-INCH WIDE STAINLESS STEEL BOX GUTTERS.
250
LF
4001EB
SECTION E
INSTALL NEW 2-1/4" X 3-1/4" PRE-FINISHED ALUMINUM DOWNSPOUTS.
300
LF
4001EC
SECTION E
INSTALL NEW 3" X 4" PREFINISHED ALUMINUM DOWNSPOUTS.
1,000
LF
4001ED
SECTION E
INSTALL NEW 2-1/4" X 3-1/4" COPPER DOWNSPOUTS.
250
LF
4001EE
SECTION E
INSTALL NEW 3" X 4" COPPER DOWNSPOUTS.
500
LF
4001EF
SECTION E
INSTALL NEW 3" ROUND COPPER DOWNSPOUTS.
100
LF
4001EG
SECTION E
INSTALL NEW 4" ROUND COPPER DOWNSPOUTS.
250
LF
4001EH
SECTION E
INSTALL NEW 6" ROUND COPPER DOWNSPOUTS.
200
LF
4001EJ
SECTION E
INSTALL NEW 3" X 4" STAINLESS STEEL DOWNSPOUTS.
250
LF
4001EK
SECTION E
REMOVE EXISTING METAL CONDUCTOR HEADS AND REPLACE WITH NEW COPPER CONDUCTOR HEADS.
30
SF
4001EL
SECTION E
REMOVE EXISTING METAL CONDUCTOR HEADS AND REPLACE WITH NEW STAINLESS STEEL CONDUCTOR HEADS.
30
SF
4001EM
SECTION E
REMOVE EXISTING METAL SCUPPER LINING AND REPLACE WITH NEW COPPER SCUPPER LINING.
30
SF
4001EN
SECTION E
REMOVE EXISTING METAL SCUPPER LINING AND REPLACE WITH NEW STAINLESS STEEL SCUPPER LINING.
30
SF
4001EP
SECTION E
REMOVE AND REINSTALL EXISTING GUTTERS AND DOWNSPOUTS.
150
LF
4001EQ
SECTION E
REALIGN AND RESECURE EXISTING GUTTERS AND DOWNSPOUTS, INCLUDES ALL NEW HARDWARE.
3,000
LF
4001ER
SECTION E
REMOVE AND DISPOSE OF EXISTING GUTTERS AND DOWNSPOUTS.
7,000
LF
4001ES
SECTION E
RESOLDER GUTTER JOINTS.
50
EA
4001ET
SECTION P
REPAIR BROKEN GUTTER JOINTS WITH SEALANT.
50
EA
4001EU
SECTION Q
CLEAN AND DISPOSE OF DEBRIS IN GUTTERS.
$3,500
LF
4001EV
-- -- --
INSTALL NEW COMMERCIAL-SIZED CONCRETE SPLASHBLOCKS.
50
EA
4001EW
SECTION E
INSTALL NEW COPPER SPLASHPANS.
10
EA
4001EX
SECTION E
INSTALL NEW STAINLESS STEEL SPLASHPANS.
10
EA
4001EY
SECTION Q
CLEAN AND CLEAR ROOF DRAINS.
50
EA
4001EZ
SECTION E
REMOVE EXISTING ROOF DRAIN SUMPS AND REPLACE WITH NEW 6-POUND LEAD DRAIN SUMPS (24" X 24" WITH 4"FLANGE).
30
EA
4001FA
-- -- --
REMOVE EXISTING ROOF DRAIN SUMPS AND REPLACE WITH NEW PVC DRAIN SUMPS (24" X 24" WITH 4"FLANGE).
17
EA
4001FB
SECTION Q
REMOVE EXISTING ROOF DRAIN STRAINERS AND REPLACE WITH NEW METAL ROOF DRAIN STRAINERS.
10
EA
4001FC
SECTION Q
REMOVE EXISTING ROOF DRAIN STRAINERS AND REPLACE WITH NEW POLY (VINYL CHLORIDE) (PVC) ROOF DRAIN STRAINERS.
10
EA

REMOVE EXISTING ROOF DRAIN AND REPLACE WITH NEW ROOF DRAIN, JOSAN 22010 SERIES,

COATED CAST IRON, OR EQUAL, WITH METAL STRAINER AND INCLUDING ALL ACCESSORIES

AND FLASHINGS. – CLINS 4001FF THRU 4001FL

4001FD
-- -- --
3-INCH DIAMETER ROOF DRAIN.
7
EA
4001FE
-- -- --
4-INCH DIAMETER ROOF DRAIN.
10
EA
4001FF
-- -- --
6-INCH DIAMETER ROOF DRAIN.
7
EA
4001FG
-- -- --
REMOVE EXISTING DRAIN PIPE WITH AND REPLACE WITH NEW 3" DIAMETER SCHEDULE 40 PVC DRAIN PIPE, INCLUDING ELBOWS, COUPLINGS, ETC.
150
LF
4001FH
-- -- --
REMOVE EXISTING DRAIN PIPE WITH AND REPLACE WITH NEW 4" DIAMETER SCHEDULE 40 PVC DRAIN PIPE, INCLUDING ELBOWS, COUPLINGS, ETC.
300
LF
4001FJ
-- -- --
REMOVE EXISTING DRAIN PIPE WITH AND REPLACE WITH NEW 6" DIAMETER SCHEDULE 40 PVC DRAIN PIPE, INCLUDING ELBOWS, COUPLINGS, ETC.
150
LF
4001FK
SECTION E
REMOVE EXISTING PITCH POCKET AND REPLACE WITH NEW COPPER PITCH POCKET, INCLUDING NAILERS, FLASHING, COUNTERFLASHING, METAL JOINT

COVER, ETC.

75
EA
4001FL
SECTION E
REMOVE EXISTING PITCH POCKET AND REPLACE WITH NEW STAINLESS STEEL PITCH POCKET, INCLUDING NAILERS, FLASHING, COUNTERFLASHING, METAL JOINT COVER, ETC.
75
EA
4001FM
SECTION E
REMOVE AND REPLACE EXISTING PITCH FROM PITCH POCKETAND REPAIR PITCH POCKET.
50
CF
4001FN
SECTION E
REMOVE EXISTING PIPE VENT FLASHING AND REPLACE WITH NEW LEAD PIPE VENT FLASHING.
50
EA
4001FP
SECTION F
REMOVE EXISTING ROOF HATCH AND REPLACE WITH NEW 2'-6" X 3'-6" ROOF HATCH WITH ALUMINUM CURB AND COVER.
14
EA
4001FQ
SECTION E
REMOVE EXISTING PIPE VENT FLASHING AND REPLACE WITH NEW GALV-NEOPRENE PIPE VENT FLASHING.
50
EA
4001FR
SECTION P
INSTALL NEW JOINT SEALANT.
3,000
LF
4001FS
SECTION P
REMOVE EXISTING JOINT SEALANT AND INSTALL NEW JOINT SEALANT.
2,600
LF
4001FT
SECTION Q
CUT NEW REGLET IN MASONRY.
300
LF
4001FU
SECTION Q
CUT NEW REGLET IN CONCRETE.
100
LF
4001FV
SECTION Q
REMOVE AND REINSTALL EXISTING ATTIC VENTILATORS.
17
EA
4001FW
SECTION E
REMOVE EXISTING ATTIC VENTILATORS AND REPLACE WITH NEW RESIDENTIAL OR COMMMERCIAL VENTILATORS.
50
LF
4001FX
SECTION U
REMOVE EXISTING RIDGE VENT AND REPLACE WITH NEW CONTINUOUS RIDGE VENT.
2,000
LF
4001FY
SECTION S

SECTION G

REMOVE EXISTING WOOD FASCIA AND REPLACE WITH NEW PAINTED WOOD FASCIA BOARD. (USE THIS ITEM FOR STANDARD-DIMENSIONED LUMBER.)
750
BF
4001GA
SECTION S

SECTION G

REMOVE EXISTING WOOD FASCIA AND REPLACE WITH NEW PAINTED WOOD FASCIA BOARD. (USE THIS ITEM FOR CUSTOM-MILLED LUMBER.)
150
BF

REMOVE EXISTING PRE-FORMED NON-STRUCTURAL METAL ROOFING AND REPLACE WITH

NEW PRE-FORMED NON-STRUCTURAL METAL ROOFING. – CLINS 4001 - - AND 4001 - -

4001GB
SECTION H
COATED STEEL ROOFING.
50
SQ
4001GC
SECTION H
COATED ALUMINUM ROOFING.
50
SQ
4001GD
SECTION Q
DISCONNECT AND RECONNECT EXISTING ROOF-MOUNTED ELECTRICAL EQUIPMENT.
34
EA
SECTION Q
LABOR CHARGES FOR ROOF LEAK INVESTIGATION AND REPAIRS. (THIS ITEM TO BE USED WITH MATERIALS FOR ISOLATED MINOR ROOF LEAK REPAIRS.)
300
HR

CONSTRUCTION AIDS - CLINS 4001GE AND 4001GH

4001GE
SECTION A
PROVIDE FIXED STEEL TUBULAR SCAFFOLDING. (COST PER CSF OF BUILDING; ONE USE PER MONTH.)
34
CSF
4001GF
SECTION A
PROVIDE MOBILE SCAFFOLD. (COST FOR

40-FOOT AERIAL LIFT.)

34
MO
4001GG
SECTION A
SURVEY EXISTING ROOF SYSTEM AND PROVIDE A WRITTEN REPORT DETAILING EXISTING CONDITIONS AND REQUIRED MAINTENANCE.
34
SQ
4001GH
SECTION A
SURVEY EXISTING ROOF SYSTEM AND BUILDING STRUCTURE AND PROVIDE A WRITTEN REPORT DETAILING EXISTING STRUCTURAL CONDITIONS, LOAD CALCULATIONS & CAPABILITIES AND REQUIRED MAINTENANCE.
50
SQ

OPTION YEAR FOUR ESTIMATED TOTAL( LINE ITEMS 4001AA THROUGH 4001GH)