CGSC ESS Conversion to C-Cure Building Breakout 13 JAN 2026.xlsx

XLSX spreadsheet 22 KB Posted

Attached to
CGSC Access Control System Replacement
Solicitation number
W91QF4-26-Q-A040
Issued by

About this file

This is a building breakout spreadsheet detailing the conversion of the CGSC (Command and General Staff College) ESS (Electronic Security System) to C-Cure access control technology, with a scheduled implementation date of January 13, 2026. The document serves as a project planning and scheduling tool for the access control system replacement initiative being procured under solicitation W91QF4-26-Q-A040.

The spreadsheet provides a granular breakdown of project tasks, phases, and activities required to transition from the existing ESS infrastructure to the C-Cure access control platform at the CGSC facility. This supporting documentation aligns with the Army's Request for Quote for commercial access control system services under NAICS code 561621 (Security Systems Services), issued by the Department of the Army Materiel Command Mission and Installation Contracting Command at Fort Eustis. The conversion project is structured to ensure comprehensive planning and coordination of all building-level system modifications necessary to implement the new C-Cure access control solution prior to the January 2026 completion target. Contractors responding to the solicitation would use this breakout schedule to understand the scope, complexity, and timeline expectations for executing the access control system replacement at the CGSC facility.

View the file

Other files

Show all 22

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Lewis & Clark

Army U Access Control Migration to C-Cure
Lewis & Clark
Provided by Eric Cashin CAC G-34
LABOR
HoursDescriptionUnit CostExtension
Install 14 iSTAR Controllers
Install G2-RM-4E Modules
Install HID Readers
Programming, provisioning and testing systems
Site Prep, commissioning
Design/Project management
Install Misc hardware/wire, wiring, etc
EQUIPMENT
QtyDescriptionPanel LocationUnit CostExtension
1iSTAR Ultra G2 - GSTAR016 16 Door ControllerRm 1115
9HID PIV Dual Factor (Contact/Contactless) Card ReaderRm 1115
1iSTAR Ultra G2 - GSTAR008 8 Door ControllerRm 1130
5HID PIV Dual Factor (Contact/Contactless) Card ReaderRm 1130
1iSTAR Ultra G2 - GSTAR016 16 Door ControllerRm 1203
10HID PIV Dual Factor (Contact/Contactless) Card ReaderRm 1203
1iSTAR Ultra G2 - GSTAR016 16 Door ControllerRm 1603
12HID PIV Dual Factor (Contact/Contactless) Card ReaderRm 1603
1iSTAR Ultra G2 - GSTAR008 8 Door ControllerRm 2026
4HID PIV Dual Factor (Contact/Contactless) Card ReaderRm 2026
1iSTAR Ultra G2 - GSTAR008 8 Door ControllerRm 2112
6HID PIV Dual Factor (Contact/Contactless) Card ReaderRm 2112
1iSTAR Ultra G2 - GSTAR008 8 Door ControllerRm 2175
8HID PIV Dual Factor (Contact/Contactless) Card ReaderRm 2175
1iSTAR Ultra G2 - GSTAR008 8 Door ControllerRm 2548
2HID PIV Dual Factor (Contact/Contactless) Card ReaderRm 2548
1iSTAR Ultra G2 - GSTAR016 16 Door ControllerRm 2603
1iSTAR Ultra G2 - GSTAR-ACM 8 door expansion boardRm 2603
18HID PIV Dual Factor (Contact/Contactless) Card ReaderRm 2603
1iSTAR Ultra G2 - GSTAR008 8 Door ControllerRm 3112
6HID PIV Dual Factor (Contact/Contactless) Card ReaderRm 3112
1iSTAR Ultra G2 - GSTAR008 8 Door ControllerRm 3168
3HID PIV Dual Factor (Contact/Contactless) Card ReaderRm 3168
1iSTAR Ultra G2 - GSTAR016 16 Door ControllerRm 3603
9HID PIV Dual Factor (Contact/Contactless) Card ReaderRm 3603
1iSTAR Ultra G2 - GSTAR016 16 Door ControllerRm 4112
1iSTAR Ultra G2 - GSTAR-ACM 8 door expansion boardRm 4112
16G2-RM-4E Door Control ModuleRm 4112
18HID PIV Dual Factor (Contact/Contactless) Card ReaderRm 4112
1iSTAR Ultra G2 - GSTAR016 16 Door ControllerRm 4170
8G2-RM-4E Door Control ModuleRm 4170
10HID PIV Dual Factor (Contact/Contactless) Card ReaderRm 4170
1MISC Wiring, Hardware, Mounting Plates, Batteries, etc
CGSC - NETWORK VIDEO CONTROLLER / RECORDER REPLACEMENT
QtyDescriptionUnit CostExtension
Avigilon NVR6 FIPS with Unity Video Management System EnterpriseVideo Server (200TB)
Avigilon AI Appliance 2XAI Integration Appliance
Programming, provisioning and testing systems
Migrate existing cameras to NIPRnet
Site Prep, commissioning
Design/Project management

CARL

Army U Access Control Migration to C-Cure
CARL
Provided by Eric Cashin CAC G-34
LABOR
HoursDescriptionUnit CostExtension
Install 1 iSTAR Controllers
Install HID Readers
Programming, provisioning and testing systems
Site Prep, commissioning
Design/Project management
Install Misc hardware/wire, wiring, etc
EQUIPMENT
QtyDescriptionPanel LocationUnit CostExtension
1iSTAR Ultra G2 - GSTAR016 16 Door ControllerC209
15HID PIV Dual Factor (Contact/Contactless) Card ReaderC209
1MISC Wiring, Hardware, Mounting Plates, Batteries, etc

GIF

Army U Access Control Migration to C-Cure
GIF
Provided by Eric Cashin CAC G-34
LABOR
HoursDescriptionUnit CostExtension
Install 1 iSTAR Controller
Install HID Readers
Programming, provisioning and testing systems
Site Prep, commissioning
Design/Project management
Install Misc hardware/wire, wiring, etc
EQUIPMENT
QtyDescriptionPanel LocationUnit CostExtension
1iSTAR Ultra G2 - GSTAR016 16 Door ControllerG227
11HID PIV Dual Factor (Contact/Contactless) Card ReaderG227
1MISC Wiring, Hardware, Mounting Plates, Batteries, etc

Flint

Army U Access Control Migration to C-Cure
FLINT
Provided by Eric Cashin CAC G-34
LABOR
HoursDescriptionUnit CostExtension
Install 1 iSTAR Controller
Install HID Readers
Programming, provisioning and testing systems
Site Prep, commissioning
Design/Project management
Install Misc hardware/wire, wiring, etc
EQUIPMENT
QtyDescriptionPanel LocationUnit CostExtension
1iSTAR Ultra G2 - GSTAR008 8 Door Controller142
7HID PIV Dual Factor (Contact/Contactless) Card Reader142
1MISC Wiring, Hardware, Mounting Plates, Batteries, etc

Muir

Army U Access Control Migration to C-Cure
MUIR
Provided by Eric Cashin CAC G-34
LABOR
HoursDescriptionUnit CostExtension
Install 1 iSTAR Controller
Install HID Readers
Programming, provisioning and testing systems
Site Prep, commissioning
Design/Project management
Install Misc hardware/wire, wiring, etc
EQUIPMENT
QtyDescriptionPanel LocationUnit CostExtension
1iSTAR Ultra G2 - GSTAR016 16 Door Controller117
7HID PIV Dual Factor (Contact/Contactless) Card Reader117
1MISC Wiring, Hardware, Mounting Plates, Batteries, etc

Truesdale

Army U Access Control Migration to C-Cure
Truesdale
Provided by Eric Cashin CAC G-34
LABOR
HoursDescriptionUnit CostExtension
Install 1 iSTAR Controller
Install HID Readers
Programming, provisioning and testing systems
Install New Lock, Door Switch, REX, Reader
Site Prep, commissioning
Design/Project management
Install Misc hardware/wire, wiring, etc
EQUIPMENT
QtyDescriptionPanel LocationUnit CostExtension
1iSTAR Ultra G2 - GSTAR016 16 Door Controller
10HID PIV Dual Factor (Contact/Contactless) Card Reader
1Electric Door Strike / Latch (new door)
1Door Position Switch (new door)
1Request-to-Exit Motion
1MISC Wiring, Hardware, Mounting Plates, Batteries, etc