limited-asbestos-roof-survey-grp8-bldg-23jan2018.pdf

PDF 778 KB Posted

Attached to
FY23 OHARNG CJAG Demolition Project
Solicitation number
W91364-23-B-0005
Issued by

About this file

This document is a bulk sample analysis certificate from Amianthus LLC Environmental Consulting regarding asbestos testing of roofing materials from buildings at the Ravenna Arsenal in Ravenna, Ohio. Ten roof samples were analyzed using polarized light microscopy and dispersion staining in accordance with EPA methods. The report indicates that friable materials containing 10% or less asbestos are to be treated as asbestos-containing unless point counting verification shows lower amounts. Quantification was determined by calibrated visual estimation.

The related federal contract opportunity is a solicitation from the Department of the Army Ohio Army National Guard for the FY23 OHARNG CJAG Demolition Project. No other details are provided regarding required products or services, response dates, pricing terms, set asides, or incumbent contractors.

View the file

Other files

File Type Posted
W91364-23-B-0005-0002 Ack.pdf PDF
W91364-23-B-0005 Q-A.docx DOCX document
W91364-23 B 0005 CJAG Demo 2023 MFR.pdf PDF
grp-8-white-painted-exterior-facia-trim-doors-feb2018.pdf PDF
ABS_GA_63-838_02_99F.pdf PDF
crjmtc_hazassmt_sep2018.pdf PDF
ABS_GA_61-851_02_99F.pdf PDF
W91364-23-B-0005 Q-A.docx DOCX document
ABS_GA_69-853_02_99F.pdf PDF
ABS_GA_61-852_02_99F.pdf PDF
ABS_GA_69-854_02_99F.pdf PDF
FY23 Demo-Pav -Site Visit Sign In 2023.08.22.pdf PDF
FY23 Demo - Site Visit Sign In 2023.08.15.pdf PDF
W91364-23-B-0005 Q-A.docx DOCX document
OHARNG Sol W91364-23-B-0005-0002.pdf PDF
W91364-23-B-0005 Q-A.docx DOCX document
Wage Determiation.pdf PDF
WageDetermination-.pdf PDF
Instructions to Bidders.docx DOCX document
OHARNG Sol W91364-23-B-0005-0001.pdf PDF
FY23 Demo PWS 3922013.pdf PDF
RFI-Form.pdf PDF
OHARNG Sol W91364-23-B-0005.pdf PDF
Bid Form CJAG Demo.docx DOCX document
Show all 24

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Amianthus LLC Environmental Consulting

583 Grayton Road

Berea, Ohio 44017

216-346-7694 fax 440-891-0022

AIHA PAT for Bulk Asbestos no. 198622 This confidential report relates only to those item(s) tested and does not represent an endorsement by AIHA or any agency of the U.S. Government

Analysis Method: EPA 600/R-93/116

CERTIFICATE OF ANALYSIS

Client: Precision Environmental Co. Report Date: 01/24/2018

5500 Old Brecksville Rd. Project: 18-04-038

Independence, Ohio 44131 Log No.: 2147

BULK SAMPLE ANALYSIS SUMMARY

Sample Identification:

Ten (10) samples representing suspect roofing materials associated with the Inert Storage Warehouse buildings 00832, 00833 and 00834 at the Ravenna Arsenal in Ravenna, Ohio were submitted by Mr. Daniel

C. Peders, CAHES #31134, exp. 8-4-2018. Samples were collected on January 23, 2018 by Mr. Peders were submitted to Amianthus LLC laboratory in Berea, Ohio for asbestos content determination.

Analytical Method:

Analytical procedures were performed in accordance with the U. S. Environmental Protection Agency (EPA)

Recommended Method for the Determination of Asbestos in Bulk Samples by Polarized Light Microscopy and

Dispersion Staining (PLM/DS) (EPA-600/M4-82-020, EPA-600/R-93-116). This report relates only to those samples actually analyzed, and may not be indicative of other similar appearing materials existing at this, or other sites.

Quantification of asbestos content was determined by Calibrated Visual Estimation.

The EPAs requires that friable samples with analytical results of 10% or less asbestos, by visual estimation, be treated as asbestos-containing material unless these quantities are verified using the point counting method. The point counting method is a systematic technique for estimating concentration, also using PLM. The point counting method, however, does not increase the analyst’s ability to detect fibers.

In any given material, fibers with a small diameter (<0.25µm) may not be detected by the PLM method. Floor tile and other resinously bound material may yield a false negative if the asbestos fibers are too small to be resolved using PLM. Additional analytical methods may be required.

Analysis Performed By: Daniel C. Peders Approved By:

Date: March 1, 2017 Daniel C. Peders

Laboratory Director

Report Date: 01/24/2018

Project: 18-04-038

Log No.: 2147

AIHA PAT for Bulk Asbestos no. 198622 This confidential report relates only to those item(s) tested and does not represent an endorsement by AIHA or any agency of the U.S. Government

Comments: PLM is not consistently reliable in detecting asbestos in floor coverings and similar non-friable organically bound materials. Before this material can be considered or treated as non-asbestos containing, confirmation must be made by quantitative TEM. (PC) Indicates Stratified Point Count Performed. Method not performed unless stated. Quantification at <0.25% by volume is possible with this method. (PC-Trace) represents this limitation of quantitation. (PC-Trace) means that asbestos was detected but is not quantifiable under the Point Count regimen.

Analysis Performed By: _Daniel C. Peders_______________ Approved By:_______________________________

Date: _January 24, 2018____________________ Daniel C. Peders

Laboratory Director

Asbestos Type(s) Detected Non-Asbestos Materials 1 of 1

L a b N o

Client No. Description Location Color % C h ry s o til e

A m o si te

C ro c id o lit

O th e r

C e llu lo s

F ib ro u s G la ss

M in e ra l W o o l

O th e r F ib ro u s

M a te ri ls

N o n -F ib ro u s

M a te ri ls

Comments

56458 ISW-01 Asphalt-based roof sheeting Flat roof over 00832 under metal roof

Black 40 0 0 0 0 0 0 60 Multiple asbestos-containing layers 56459 ISW-02 Black 35 0 0 0 0 0 0 65

56460 ISW-03 Asphalt-based roof tar At parapet of center dividing wall under metal and black rubber

Black 0 0 0 0 20 0 0 80

56461 ISW-04 Black 0 0 0 0 15 0 0 85

56462 ISW-05 White caulk On seams of metal roofs White 0 0 0 0 0 0 0 100

56463 ISW-06 White 0 0 0 0 0 0 0 100

56464 ISW-07 Asphalt-based roof sheeting Flat roof over 00833 under metal roof Black 40 0 0 0 0 0 0 60 Multiple asbestos-containing layers

56465 ISW-08 Black 45 0 0 0 0 0 0 55

56466 ISW-09 Asphalt-based roof sheeting Flat roof over 00834 under metal roof

Black 45 0 0 0 0 0 0 55 Multiple asbestos-containing layers 56467 ISW-10 Black 45 0 0 0 0 0 0 55

This confidential report relates only to those item(s) tested and does not represent an endorsement by AIHA or any agency of the U.S. Government

Comments: PLM is not consistently reliable in detecting asbestos in floor coverings and similar non-friable organically bound materials. Before this material can be considered or treated as non-asbestos containing, confirmation must be made by quantitative TEM. (PC) Indicates Stratified Point Count Performed. Method not performed unless stated. Quantification at <0.25% by volume is possible with this method. (PC-Trace) represents this limitation of quantitation. (PC-Trace)

Analysis Performed By: _Daniel C. Peders_______________ Approved By:_______________________________

This confidential report relates only to those item(s) tested and does not represent an endorsement by AIHA or any agency of the U.S. Government

Comments: PLM is not consistently reliable in detecting asbestos in floor coverings and similar non-friable organically bound materials. Before this material can be considered or treated as non-asbestos containing, confirmation must be made by quantitative TEM. (PC) Indicates Stratified Point Count Performed. Method not performed unless stated. Quantification at <0.25% by volume is possible with this method. (PC-Trace) represents this limitation of quantitation. (PC-Trace)

Analysis Performed By: _Daniel C. Peders_______________ Approved By:_______________________________

Typical Interior Structure (00832) with wood roof deck and wood roof joists.

Typical roof construction with metal roof (00832) over asphalt-based roofing materials (00834)

This confidential report relates only to those item(s) tested and does not represent an endorsement by AIHA or any agency of the U.S. Government

Comments: PLM is not consistently reliable in detecting asbestos in floor coverings and similar non-friable organically bound materials. Before this material can be considered or treated as non-asbestos containing, confirmation must be made by quantitative TEM. (PC) Indicates Stratified Point Count Performed. Method not performed unless stated. Quantification at <0.25% by volume is possible with this method. (PC-Trace) represents this limitation of quantitation. (PC-Trace)

Analysis Performed By: _Daniel C. Peders_______________ Approved By:_______________________________

00832 00832 metal roof over asphalt-based roofing material

(ISW-01 & 02)

00832 tar coating (ISW-03) on center parapet wall under metal and rubber flashing

This confidential report relates only to those item(s) tested and does not represent an endorsement by AIHA or any agency of the U.S. Government

Comments: PLM is not consistently reliable in detecting asbestos in floor coverings and similar non-friable organically bound materials. Before this material can be considered or treated as non-asbestos containing, confirmation must be made by quantitative TEM. (PC) Indicates Stratified Point Count Performed. Method not performed unless stated. Quantification at <0.25% by volume is possible with this method. (PC-Trace) represents this limitation of quantitation. (PC-Trace)

Analysis Performed By: _Daniel C. Peders_______________ Approved By:_______________________________

00832 white caulk (ISW-05) on seams of metal roof 00833 00832 tar coating (ISW-04) on center parapet wall under metal and rubber flashing

This confidential report relates only to those item(s) tested and does not represent an endorsement by AIHA or any agency of the U.S. Government

Comments: PLM is not consistently reliable in detecting asbestos in floor coverings and similar non-friable organically bound materials. Before this material can be considered or treated as non-asbestos containing, confirmation must be made by quantitative TEM. (PC) Indicates Stratified Point Count Performed. Method not performed unless stated. Quantification at <0.25% by volume is possible with this method. (PC-Trace) represents this limitation of quantitation. (PC-Trace)

Analysis Performed By: _Daniel C. Peders_______________ Approved By:_______________________________

00833 metal roof over asphalt-based roofing material

(ISW-07 & 08)

00834 00833 metal roof over asphalt-based roofing material

(ISW-09 & 10)