02 82 14.00 10 - B. 673 Asbestos Report - Merged.pdf

PDF 1 MB Posted

Attached to
Indefinite Delivery/Indefinite Quantity Construction Multiple Award Task Order Contract
Solicitation number
W912WJ20R0005
Issued by

About this file

This document contains a federal solicitation for an Indefinite Delivery/Indefinite Quantity Construction Multiple Award Task Order Contract and an asbestos survey report for buildings at Fort Devens, Massachusetts.

The solicitation is for a five-year $90 million ID/IQ MATOC for construction services issued by the U.S. Army Corps of Engineers, New England District. The scope of work includes minor new construction, renovation, repairs, upgrades and alterations for vertical construction projects. Task orders will range from $500,000 to $10 million and may include incidental civil, environmental abatement and design work. The solicitation targets awarding contracts to six small businesses and will use best value procedures. The projected award date is July 2020.

The asbestos survey report evaluates buildings in the Reserve Enclave at Fort Devens. It identifies asbestos-containing materials like pipe insulation and their locations. The report was prepared for the U.S. Army Environmental Center to support base realignment and closure environmental evaluation activities.

View the file

Other files

File Type Posted
W912WJ20R0005 0006.pdf PDF
W912WJ20R0005 0005.pdf PDF
WBS format for Sample Task Order_rev 5-28-2020.xlsx XLSX spreadsheet
Prime Binding Rates Excel Sheet_rev 5-28-20.xlsx XLSX spreadsheet
Attachment 0001 - Prime Binding Rates Excel Sheet_rev 5-18-20.xlsx XLSX spreadsheet
W912WJ20R0005-00004.pdf PDF
WBS format for Sample Task Order Attachment.pdf PDF
W912WJ20R0005-0003.pdf PDF
W912WJ20R0005-0002.pdf PDF
W912WJ20R0005 0001.pdf PDF
Sample Task Order special contract requirements document.doc DOC document
Sample Task Order Rates Excel Sheet.xlsx XLSX spreadsheet
00 41 00.doc DOC document
Drawings - Sample TO.pdf PDF
W912WJ20R0005 Solicitation.pdf PDF
Wage Determination MA20200013.pdf PDF
Specifications - Sample TO.pdf PDF
Prime Binding Rates Excel Sheet.xlsx XLSX spreadsheet
Show all 18

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

AfTAl-A.w; f b\ f Z ICl Sec rio V'j "l.. B z. Ill. 0 ()

A.JJ~

Prografu 1vfanager.~

~?V~ Tas~ Manager. Richard Waterman

This dOC1Jment Is printed on recycled paper ana IS reoy::laJ:/a.

S-Io-q;f' Date

(/q/9F Date

Final Asbestos Report

(AREE 65)

Base Realignment and Closure.

Environ mental Evaluation· (BRAe EE) Part If Fort Devens, MA

Submitted to'

U.s. Army Environmental Center (USAEC) .

Aberdeen proving Ground, Maryland

Revision i ~y1995

Arthur D. Littles [ne.

Acorn Park

. Cambridge, Massachusetts 02140~239()

ADt Reference 67011·63

OAAA1&-91-D-0016

Delivery Order 0011

Fmal Report: - Section No.:

Revision No.:

Date:

Fort Devens BE Part II roc May 1995

Table of Contents

List of Acronyms and Abbreviations ..••••••...•••..•...•••.•••••.•• 1Il

ExQcutivs Summary ..•. II a , •••• 1; e _ ...... III • « ••• ~ ...... '" <II •••• q .... ,. • • ' iv

\Jt~:trve . .. .. . ... . .. .. .. v • : • .. .. _ ... .. • .. .. .. .. ., • • .. ... .. • .. .. • .. J • ..

Previous tsti1l:t:ies-- Project organization an~"""""1"\

--~~ 1.4 Report Organization , .. ~ .. .--c ___

2.2

2.3 c ..••••................•.•.•.•••.• - .

2.1.1 Data Ga£hering and Tracking ....•••....•..•.••••..... 2-1

2.1.1.1 Description of the USAEC ACM AsseSsment checklist . 2~2.·

3.0 Evaluation Results ..•..•••••••••••••••••• ' ••••••••••••••••••. 3-1

3.1 Reserve Enclave ..........•.... ', .•................. ~ ... 3-2

3.2 Build:ing~ Structurally Similar to, But Not Included in, the Reserve

. Enclave ..................•...•....... ~ . . . . . . . . . . . . . 3-2.

Final Report:

Section No.:

Revision No.:

Date:

Fort Devens EEPart II.

Acronyms List May 1995

Li.st of Acronyms and Abbreviations

ACBM

ACM

AHERA

AREE

BRACEE

EPA

HASP

MADU

NESHAP

NIST·

NVLAP

O&M

OSHA

PACM

PLM

QAPjP

QC

SA:CBM

'!EM

TSI

USAEC

USATHAMA

Asbestos-Containing Builcling Materials Asbestos-Containing Materials Asbestos Hazard Emergency Response Act Areas Requiring Environmental Evaluation Base Realignment and Closure, Environmental Evaluation U.S. Environmental Protection Agency- Health and Safety Plan Massachusetts Department of Labor and Industries National Emissions Standard of Ifuzardous Air Polhitants National Institute of Standards and Technology _ National Voluntary Laboratory Accreditation Program Operations and Maintenance .

Occupational Safety and Health Adn:ll.$tration Presumed Asbestos-Containing Materials Polariz:ed Light Microscopy QualitY Assurance Project Plan Quality Control .

Homogenous Suspect Asbestos Containing Building Materials Transmission Electron Microscopy Thennal Systems Insulations U. S . .Army Environmental Center U.S. Army Toxic and Hazardous Materials Agency

6'Jt T/llf t:. f

Final Report:

Section No.:

Fort Devens BE Part n 2.0

Revision No.: 1 Date: May 1995

17 to 13 A A B c F

12 to 9 A B c D F

8to5 B c D E F

4 to 1 c D E F F o F F F F F

According to the USAEC Guidelines for As,bestos Hazard Assessments in u.s. Anny F aciliii.es the· following corrective actions are recommended for each assessment value.

A Ta.tce immediate actioR to isolate the area, restrict access, and/or immediately remove ACBM If removal ~ needed,. action planning needs to include a detailed survey.

B· Initiate a special 0&11 program immediately. Possible follow-up actions may include limiting access to the area or removal.

C Inltiate a special O&M· program and plan for potential removal ofACBM.

D Initiate a special O&M program. Damaged areas should be repaired.

E . Continue a special O&M program and frequently monitor the condition of the ACBM. Tke steps to prevent damage to ACBM. .

F No immediate action necessary. Continue a speCial O&M program until major renovation or demolition requires removal or until assessment factors change. .

o Section 4 - The fourth and final section of the USAEC ACM Assessment Checklist is the sampling results section. Each sample collected was given a sample identification number. The results were presented according to the percent and type of asbestos found in each building material. fu' addition, the drawing number showing the location of the sample was referenced.

3.0 Evaluation Results

Fma! Report:

Section No.!

Revision No.:

Date:

Fort Devens BE Part II 3.0 May 1995

This section summarizes the type and amount of ACBM by area and building function on Fort Devens. There are a total of 20 groupings, 12 pertaining to industrial areas and 8 pertaining to residential areaS (Refer to Figure 1). The groupings are as follows:

1. Reserve Enclave Buildings

2. Buildings structurally similar to, but not included ~ the Reserve Enclave

3. Barnum Road and Industrial Area Buildings

4. Intelligence Schoo~ Buildings

5. North Post Buildings

6. World War I Era Bulldffigs

7. Bachelor OffiCe!:s' Quarters

8. Ma::,o-azine Area

9. World War II Era Wooden

Buildings

10. "Water Treatmentr Sewage Transfer

Stations, Material Storage Buildings, and Post Gates'

11. Buildings Constructed Between 1955 and 1980

12. Buildings Constructed After 1980

13. Verbeck Housing Area

14. Daveo, Salerno, Shiloh, and

Sbit;1ey Housing Areas

15. Colonial Housing Area

16. Multi-Colonial Housing Area

17. Bungalow Housing Area

18. Buena Vista" Housing Area

19. Housing Areas 306, 500, and 800

20. Ranch Hciusing Area

Note: For all buildings refer to the tabIe on page 2·5 for a description of the recommended cone..."'tive action that should he taken for each assessment value.

The tables at the end of this section are arranged according to risk assessment value, material" classification, building number, and pe.rcent and type of asbestos. The tables also present the material description, and the total amount of material present and/or damaged. It should be noted that in some areas, material that is usuaJIy sampled was inaccessible and, therefore, assumed to contain asbestos. .

3.1 Reserve Enclave

Fin~ Report Section No.:

Revision No.:

Date:

Fort Devens BE Part II 3.0 May 1995

Reserve Enclave buildings encompaSs a·large portion of the Main Post with a majority of the buildings constructed during the 1960s. The following building.

materials were found to. contain asbestos: magnesia/cruciform. aircell and wrapped paper pipe insulation, fittings on both asbestos and non-asbestos pipe runs, tank insulation, stack insulation, heat exchanger :insulation, wallf?oard and wallboard with joint compound, duct insulation, and 12 by 12"inch vinyl floor tile and associated mastic. The folloWing materiais were not sampled, but assumed to cont:ain asbestos:

duct joiner, rope gasketing, roofing sealant, fire door insulation, ceiling tile, transite .

board, and 9 by 9-mch'vinyl floor tile and associated mastic. The magnesiafca1cifonn pipe insulation in Buildings 637 and 638 'and pipe fitting insulation in Building .639 were assigned an "AU exposure· assessment value.·

601 608 618 642 658 671 678 685 . 694 34li 602 612 619 643 '665 673 679 686 695 3412 603 613 623 644 666 674 680 687 696 3413 604 614 637 .646 667 675 681' . 688 697 3574

605. 615 638 653 668 676 683 689 2008 3773 606 616 640 656 669 677 684 693 2009 3774

607. 617 641 657 670

'. 3.2 Buildings structurally Similar to, But Not .Included in, the ~eserve Enclave

These buildings are located in the area of the Reserve Enciave,and structuraUy very similar to Enclave buildings. The following building materials were found to contain asbestos: ~ inSulation, pipe and fitting :insulanon on steam lines, pipe fittings on non-asbestos pipe runs~ heat exchanger insulation, pipe fittings on heating hot water lines with non-asbestos pipe iuns, 12 by 12:-inch vinyl floor tile and associated mastic. The follo'wing materials were not sampled, but assumed to contain asbestos:

ductjoinerfanti-vibration material; rope.gasketing, roofing paperftar. roofffig sealant, roof shingles, fire door insulation, and 9 'by 9-mch Vinyl floor tile and associated mastic. Tank insulation in Buildings 647, 651, and 692, magnesiafca1cifoml pipe insulation and pIpe fittings on non-asbestos pipe runs in Building 652 were assigned a "e" exposure assessment value.

64S

. i

·C)(TIfA'T Final Report: Fort Devens EE Part II TOe - Section No.:

Revision No.: I Date: May 1995

3.18 Buena Vista Housing Area ............................. 3 11-

3.19 Honsing Areas 300. 500, and 800 ....... : ................. 3-11 3~~~~~~~~~~~~~~~~~~~~~~~~~~

Appendix A

List of Tables

--;;:;::: y 1. Reserve Enclave Buildings f',.q c;, e s -s:; 7> 11/ Ii IVO /1- =9 2. Buildings Structurally Similar to, .. but not Included in the Reserve Enclave

List of Figures

Figure 1: Building Groups - Asbestos Survey (plate)

Table 1. Reserve Enclave Buildings

ASBESTOS SURVEY SUMMARY REPORT· RESERVE ENCLAVE BUILDINGS

Material Material Assessment ACMl ACMl ACM2 ACM2 Material Total Classification Building Description Index (%) Type (%) Type Total Damage Unit Size Color

ACM 637 MagnesialCalciforrn Pipe Insul.on Stearn Heating Line(s) A 10 CHRYSOTILE 65 45AM120CR 690 690 LF <6" WHITE ACM 637 MagnesiaICalcifonn Pipe Insul.on Stearn Heating Line(s) A 10 REF08A 65 REF08A 690 690 LF <6" WHITE ACM 637 Magnesia/CaIcifonn Pipe Insul.on Slearn Heating Line(s) A 10 REF08A 65 REF08A 690 690 LF <6" WHITE ACM 637 Pipe Fitting(s) on Stearn Heating Lines - Asbestos Runs A 10 REF08A 65 REF08A 66 66 EA <6" NA ACM 637 Pipe Fitting(s) on Stearn Heating Lines - Asbestos Runs A 10 REF08A 65 REF08A 66 66 EA <6" NA ACM 637 Pipe Fitting(s) on Steam Heating Lines - Asbestos Runs A 10 REF08A 65 REF08A 66 66 EA <6" NA ACM 638 MagnesialCalcifonn Pipe Insul.on Stearn Heating Line(s) A 10 CHRYSOTILE 65 45 AMl20CR 690 690 LF <6" WHITE ACM 637 Pipe FittinS(s) on Asbestos Pipe Runs B 40 CHRYSOTILE 35 8 EA <6" NA ACM 637 Aircell Pipe Insulation B 25 CHRYSOTILE 105 15 LF <6" NA ACM 637 Aircell Pipe Insulation B 25 REF 14A 105 15 LF <6" NA ACM 637 Aircell Pipe IDBulation B 25 REF 14A 105 15 LF <6" NA ACM 638 Pipe Fitting(s) on Asbestos Pipe Runs B 40 CHRYSOTILE 38 10 EA <6" NA ACM 638 Pipe Fitting(s) on Asbestos Pipe Runs B 40 REF llA 38 10 EA <6" NA ACM 638 Pipe Fitting(s) on Asbestos Pipe Runs B 40 REF llA 38 10 EA <6" NA ACM 638 Pipe Fitting(s) on Stearn Heating Lines - Asbestos Runs B 10 CHRYSOTILE 65 45AM120CR 76 20 EA <6" NA ACM 644 Breech or Stack Insulation- MagnesiaICaIcifonn B 50 CHRYSOTILE 240 144 SF NA WHITE ACM 644 Breech or Stack Insulation- MagnesiaICalciforrn B 50 REF 13A 240 144 SF NA WHITE ACM 644 Breech or Stack Insulation- MagnesiaICalciforrn B 50 REF 13A 240 144 SF NA WHITE ACM 644 Low Telq)Crature Tank Insulation- MasnesialCalciforrn B 30 CHRYSOTILE 20 15 AMl5 CR 280 280 SF NA NA ACM 644 Low Telq)Crature Tank Insulation- MagnesialCalciforrn B 30 REF 12A 20 REF 12A 280 280 SF NA NA ACM 644 Low Telq)Crature Tank Insulation- MagnesialCalciforrn B 30 REF 12A 20 REF 12A 280 280 SF NA NA ACM 666 Pipe Fitting(s) on Non-Asbestos Pipe Runs B 20 CHRYSOTILE 402 200 EA <6" GRAY ACM 666 Pipe Fitting(s) on Non-Asbestos Pipe Runs B 5 CHRYSOTILE 402 200 EA <6" GRAY ACM 638 Aircell Pipe IDBulation C 25 CHRYSOTILE 60 0 LF <6" NA ACM 641 Pipe FittinS(s) on Stearn Heating Lines - Asbestos Runs C 45 CHRYSOTILE 12 10 AM12 CR 72 4 EA <6" NA ACM 641 Aircell Pipe Insulation C 5 CHRYSOTILE 340 10 LF <6" NA ACM 641 Pipe Filting(s) on Asbestos Pipe Runs C 5 CHRYSOTILE 58 9 EA <6" NA ACM 642 Breech or Stack Insulation- MagnesiaICalciforrn C 50 CHRYSOTILE 700 50 SF NA WHITE ACM 642 Pipe Filting(s) on Stearn Heating Lines· Asbestos Runs C 45 CHRYSOTILE 12 10 AM12 CR 168 15 EA <6" NA ACM 642 Low Telq)Crature Tank Insulation- MagnesialCalciform C 30 CHRYSOTILE 20 15 AMl5CR 280 10 SF NA NA ACM 642 Aircell Pipe Insulation C 5 CHRYSOTILE 1080 80 LF <6" NA ACM 642 Pipe Fitting(s) on Asbestos Pipe Runs C 5 CHRYSOTILE 90 15 EA <6" NA ACM 644 Pipe Fitting(s) on Stearn Heating Lines - Asbestos Runs C 45 CHRYSOTILE 12 10 AMI2 CR 63 3 EA <6" NA ACM 644 Pipe Fitting(s) on Stearn Heating Lines - Asbestos Runs C 45 REF08A 12 REF08A 63 3 EA <6" NA ACM 644 Pipe Filting(s) on Stearn Heating Lines - Asbestos Runs C 45 REF08A 12 REF08A 63 3 EA <6" NA ACM 644 Aircell Pipe IDBulation C 5 CHRYSOTILE 1235 155 LF <6" NA

Page

ASBESTOS SURVEY SUMMARY REPORT - RESERVE ENCLAVE BUILDINGS

Material Material Assessment ACMI ACMI ACM2 ACM2 Material Total Oassification Building Description Index (%) Type (%) Type Total Damage Unit Size Color

ACM 644 Aircell Pipe Insulation C 5 REF04A 1235 155 LF <6" NA ACM 644 Aircell Pipe Insulation C 5 REF04A 1235 155 LF <6" NA ACM 644 Pipe Fitting(s) on Asbestos Pipe Runs C 5 REF04A 115 20 EA <6" NA ACM 644 Pipe Fitting(s) on Asbestos Pipe Runs C 5 REF04A 115 20 EA <6" NA ACM 644 Pipe Fitting(s) on Asbestos Pipe Runs C 5 REF04A 115 20 EA <6" NA ACM 653 Pipe Fitting(s) on Steam Heating Lines - Non-Asb. Runs C 10 CHRYSOTILE 131 5 EA <6" WHITE ACM 653 Pipe Fitting(s) on Steam Heating Lines - Non-Asb. Runs C 10 CHRYSOTILE 131 5 EA <6" WHITE ACM 674 Pipe Fitting(s) on Non-Asbestos Pipe Runs C 20 CHRYSOTILE 470 118 EA <6" GRAY ACM ·674 Pipe Fitting(s) on Non-Asbestos Pipe Runs C 5 CHRYSOTILE 470 118 EA <6" GRAY ACM 683 Breech oc Stack Insulation- Magnesia/Calciform C 40 CHRYSOTILE 30 AMOSITE 20 0 LF >6" GRAY-WHITE ACM 683 Breech oc Stack Insulation- Magnesia/Calciform C 40 REF04A 30 REF04A 20 0 LF >6" GRAY-WHITE ACM 683 Breech oc Stack Insulation- Magnesia/Calciform C 40 REF04A 30 REF04A 20 0 LF >6" GRAY-WHITE ACM 685 Heat Exchanger Insulation- MagnesialCalciform C 70 CHRYSOTILE 80 0 SF NA GRAY-WHITE ACM 685 Heat Exchanger Insulation- MagnesialCalcifl1!11l C 70 REF06A 80 0 SF NA GRAY-WHITE ACM 685 Heat Exchanger Insulation- MagnesialCalciform C 70 REF06A 80 0 SF NA GRAY-WHITE ACM 695 Pipe Fitting(s) on Non-Asbestos Pipe Runs C 20 CHRYSOTILE 20 0 EA <6" GRAY ACM 695 Pipe Fitting(s) on Non-Asbestos Pipe Runs C 5 CHRYSOTILE 20 0 EA <6" GRAY ACM 697 Pipe Fitting(s) on Non-Asbestos Pipe Runs C 20 CHRYSOTILE 114 10 EA <6" GRAY ACM 697 Pipe Fitting(s) on Non-Asbestos Pipe Runs C 20 REF05A 114 10 EA <6" GRAY ACM 697 Pipe Fitting(s) on Non-Asbestos Pipe Runs C 20 REF05A 114 10 EA <6" GRAY ACM 637 Pipe Fitting(s) on Asbestos Pipe Runs D 25 REF 14A 9 0 EA <6" NA ACM 637 Pipe Fitting(s) on Asbestos Pipe Runs D 25 REF 14A 9 0 EA <6" NA ACM 637 Pipe Fitting(s) on Asbestos Pipe Runs D 25 REFI4A 9 0 EA <6" NA ACM 638 Pipe Fitting(s) on Asbestos Pipe Runs D 25 CHRYSOTILE 12 0 EA <6" NA ACM 642 Pipe Fitting(s) on Steam Heating Lines - Asbestos Runs D 60 CHRYSOTILE 14 2 EA >6" NA ACM 644 Pipe Fitting(s) on Steam Heating Lines - Asbestos Runs D 60 CHRYSOTILE 8 EA >6" NA ACM 644 Pipe Fitting(s) on Steam Heating Lines - Asbestos Runs D 60 REF lIA 8 EA >6" NA ACM 644 Pipe Fitting(s) on Steam Heating Lines - Asbestos Runs D 60 REF lIA 8 EA >6" NA ACM 646 Pipe Fitting(s) on Steam Heating Lines - Non-Asb. Runs D 10 CHRYSOTILE 113 3 EA <6" WHITE ACM 646 Pipe Fitting(s) on Steam Heating Lines - Non-Asb. Runs D 10 REF08A 113 3 EA <6" WHITE ACM 646 Pipe Fitting(s) on Steam Heating Lines - Non-Asb. Runs D 10 REF08A 113 3 EA <6" WHITE ACM 656 Pipe Fitting(s) on Steam Heating Lines - Non-Asb. Runs D 10 CHRYSOTILE 12 0 EA <6" WHITE ACM 656 Pipe Fitting(s) on Steam Heating Lines - Non-Asb. Runs D 10 CHRYSOTILE 12 0 EA <6" WHITE ACM 666 Low Temperature Tank Insulation- MagnesialCalciform D 70 CHRYSOTILE 532 I SF NA WHITE ACM 666 Low Temperature Tank Insulation- MagnesialCalciform D 20 CHRYSOTILE 532 I SF NA WHITE ACM 675 Breech or Stack Insulation- MagnesiaICalciform D 40 CHRYSOTILE 100 0 SF NA WHITE

Material Oassification Building

Material Description

ASBESTOS SURVEY SUMMARY REPORT - RESERVE ENCLAVE BUILDINGS

Assessment ACM 1 Index (%)

ACMI

Type

ACM2 ACM2

(%) Type

Material Total

Total Damage Unit Size Color

ACM 676 Breech <.- Stack Insulation- Magnesia/Calciform D 40 CHRYSOTILE 100 0 SF NA GRAY ACM 676 Breech <.- Stack Insulation- MagnesiaiCalciform D 40 REF 07 A 100 0 SF NA GRAY ACM 676 Breech<.-StackInsulation-Magnesia/Calciform D 40 REF07A 100 0 SF NA GRAY ACM 678 Pipe Fitting(s) on Steam Heating Lines - Non-Asb. Runs D 10 CHRYSOTILE 12 0 EA <6" WHITE ACM 678 Pipe Fitting(s) on Steam Heating Lines - Non-Asb. Runs D 10 CHRYSOTILE 12 0 EA <6" WHITE ACM 688 Pipe Fitting(s) on Steam Heating Lines - Non-Asb. Runs D 10 CHRYSOTILE 316 0 EA <6" WHITE ACM 688 Pipe Fitting(s) on Steam Heating Lines-Non-Asb. Runs D 10 CHRYSOTILE 316 0 EA <6" WHITE ACM 689 Pipe Fitting(s) on Steam Heating Lines - Non-Asb. Runs D 10 CHRYSOTILE 226 0 EA <6" WHITE ACM 689 Pipe Fitting(s) on Steam Heating Lines - Non-Asb. Runs D 10 REF 08A 226 0 EA <6" WHITE ACM 689 Pipe Fitting(s) on Steam Heating Lines - Non-Asb. Runs D 10 REF 08A 226 0 EA <6" WHITE ACM 693 Low TeJl1)Crature Tank Insulation- MagnesiaiCalciform D 70 CHRYSOTILE 532 SF NA WHITE ACM 693 Low Temperature Tank Insulation- MagnesiaiCalciform D 70 REF 06A 532 SF NA WHITE ACM 693 Low Temperature Tank Insulation- MagnesiaiCalciform D 70 REF 06A 532 SF NA WHITE

ASSUMED-ACM 637 Duct Joiner or Anti-Vibration Material DIONA 195 0 SF NA WHITE ASSUMED-ACM 638 Duct Joiner or Anti-Vibration Material DIONA 195 0 SF NA WHITE ASSUMED-ACM 641 Duct Joiner or Anti-Vibration Material D 10 NA 25 0 SF NA NA ASSUMED-ACM 641 Rope Gasket DIONA 150 0 LF NA WHITE ASSUMED-ACM 642 Duct Joiner or Anti-Vibration Material D 10 NA 40 1 SF NA NA ASSUMED-ACM 642 Rope Gasket D 10 NA 312 5 LF NA WHITE ASSUMED-ACM 644 Duct Joiner or Anti-Vibration Material DIONA 56 0 SF NA NA ASSUMED-ACM 644 Rope Gasket DIONA 312 3 LF NA WHITE ASSUMED-ACM 666 Duct Joiner or Anti-Vibration Material DIONA 36 0 SF NA GRAY ASSUMED-ACM 671 Duct Joiner or Anti-Vibration Material DIONA 3 0 SF NA WHITE ASSUMED-ACM 675 Duct Joiner or Anti-Vibration Material D 10 NA 14 0 SF NA WHITE ASSUMED-ACM 676 Duct Joiner or Anti-Vibration Material DIONA 14 0 SF NA WHITE ASSUMED-ACM 677 Duct Joiner or Anti-Vibration Material DIONA 36 0 SF NA WHITE ASSUMED-ACM 679 Duct Joiner or Anti-Vibration Material D 10 NA 36 0 SF NA WHITE ASSUMED-ACM 680 Duct Joiner or Anti-Vibration Material DIONA 16 0 SF NA WHITE ASSUMED-ACM 684 Duct Joiner or Anti-Vibration Material D 10 NA 36 0 SF NA WHITE ASSUMED-ACM 686 Duct Joiner or Anti-Vibration Material DIONA 16 0 SF NA WHITE ASSUMED-ACM 687 Duct Joiner or Anti-Vibration Material DIONA 36 0 SF NA WHITE ASSUMED-ACM 689 Duct Joiner or Anti-Vibiation Material DIONA 20 0 SF NA GRAY ASSUMED-ACM ..693 Roofing Sealant DIONA 428 2 SF NA WHITE

~-~AS~S~U~M~E~D-~A~C~M~~(~69~6~~Du~ct~J=ru=ner~O~r~An=b~'-~V~ibr~atJ~·=on~M~at=en~·a~I __________________ ~D~ ____ 710~~N.~A _______ . ____________________ ~3~0 ____ ~0~~S~F __ ~NwA~ ___ W~Hll]L ASSUMED-ACM 2008 Duct Joiner or Anti-Vibration Material D 10 NA 3 0 SF NA GREEN

ACM 603 Breech or Stack Insulation- MagnesiaJCalciform E 70 CHRYSOTILE 42 2 SF 2' WHITE

Classification Building Description Index (%) Type (%) Type Total Damage Unit Size Color

ACM 603 Breech or Stack Insulation- MagnesialCalciform E 70 REF07A 42 2 SF 2' WHITE ACM 603 Breech or Stack Insulation- MagnesialCalciform E 70 REF07A 42 2 SF 2' WHITE ACM 60S WaIJ Board or Wall Board W/loint Compound E 2 CHRYSOTILE 740 0 SF NA WHITE ACM 60S WaIJ Board or WaIJ Board W/Joint Compound E 2 REFOIA 740 0 SF NA WHITE ACM 606 WaIJ Board or WaIJ Board W/loint Compound E 2 CHRYSOTILE 740 0 SF NA NA ACM 614 Wall Board or WaIJ Board W/Joint Compound E 2 CHRYSOTILE 740 0 SF NA WHITE ACM 618 WaIJ Board or Wall Board W/Joint Compound E 2 CHRYSOTILE 740 0 SF NA WHITE ACM 643 Wrapped Paper Pipe Insulation E IS CHRYSOTILE 75 LF <6" TAN ACM 643 Wrapped Paper Pipe Insulation E 15 REFOlB 75 LF <6" TAN ACM 643 Wrapped Paper Pipe Insulation E 15 REF03B 75 LF <6" TAN ACM 643 Pipe Fitting(s) on Asbestos Pipe Runs E 15 REF03B 32 EA <6" GRAY ACM 643 Pipe Fitting(s) on Asbestos Pipe Runs E 15 REF03B 32 EA <6" GRAY ACM 643 Pipe Fitting(s) on Asbestos Pipe Runs E 15 REF03B 32 EA <6" GRAY ACM 673 Pipe Fitting(s) on Non-Asbestos Pipe Runs E 20 CHRYSOTILE 60 0 EA <6" NA ACM 673 Pipe Fitting(s) on Non-Asbestos Pipe Runs E 5 CHRYSOTILE 60 0 EA <6" NA ACM 674 Low TeIqlerature Tank Insulation- MagnesialCalciform E 70 CHRYSOTILE 532 1 SF NA WHITE ACM 674 Low Temperature Tank Insulation- MagnesialCalciform E 20 CHRYSOTILE 532 1 SF NA WHITE ACM 683 Pipe Fitting(s) on Non-Asbestos Pipe Runs E 20 CHRYSOTILE 211 0 EA <6" GRAY ACM 685 Pipe Fitting(s) on Non-Asbestos Pipe Runs E 20 CHRYSOTILE 176 0 EA <6" GRAY ACM 685 Pipe Fitting(s) on Non-Asbestos Pipe Runs E 20 REF05A 176 0 EA <6" GRAY ACM 685 Pipe Fitting(s) on Non-Asbestos Pipe Runs E 20 REFOSA 176 0 EA <6" GRAY ACM 686 Pipe Fitting(s) on Heating HotWater lines - Non-Asb. Runs E 10 CHRYSOTILE 176 0 EA <6" GRAY ACM 686 Pipe Fitting(s) on Heating HotWater lines - Non-Asb. Runs E 10 REFI2A 176 0 EA <6" GRAY ACM 686 Pipe Fitting(s) on Heating HotWater lines - Non-Asb. Runs E 10 REF 12A 176 0 EA <6" GRAY ACM 693 Heat Exchanger Insulation- MagnesialCalciform E 50 CHRYSOTILE 34 0 SF NA WHITE ACM 693 Heat Exchanger Insulation- MagnesialCalciform E 50 REF07A 34 0 SF NA WHITE ACM 693 Heat Exchanger Insulation- MagnesiaiCalciform E 50 REF07A 34 0 SF NA WHITE ACM 693 Pipe Fitting(s) on Non-Asbestos Pipe Runs E 5 CHRYSOTILE 87 2 EA <6" GRAY ACM 693 Pipe Fitting(s) on Non-Asbestos Pipe Runs E 5 REFOSA 87 2 EA <6" GRAY ACM 693 Pipe Fitting(s) on Non-Asbestos Pipe Runs E 5 REFOSA 87 2 EA <6" GRAY ACM 697 Low Temperature Tank Insulation- MagnesialCalciform E 20 CHRYSOTILE 532 SF NA WHITE ACM 697 Low Temperature Tank Insulation- MagnesialCalclform E 20 REF06A 532 SF NA WHITE ACM 697 Low Temperature Tank Insulation- MagnesialCalciform E 20 REF06A 532 SF NA WHITE

ASSUMED-ACM 674 Duel Joiner or Anti-Vibration Material E 10 NA 36 SF NA GRAY ASSUMED-ACM 681 Duel loin« or Anti-Vibration Material E 10 NA 18 0 SF NA GRAY ASSUMED-ACM 688 Duct Join« or Anti-Vibration Material E 10 NA 12 0 SF NA GRAY

Qassification Building

ASSUMED-ACM 693

ASSUMED-ACM 695

ASSUMED-ACM 697

ASSUMED-ACM 3773

ACM 605

ACM 605

ACM 605

ACM 605

ACM 606

ACM 614

ACM 618

ACM 641

ACM 642

ACM 644

ACM 644

ACM 644

ACM 644

ACM 644

ACM 644

ACM 644

ACM 644

ACM 644

ACM 644

ACM 644

ACM 644

ACM 644

ACM 644

ACM 646

ACM 646

ACM 646

ACM 646

ACM 656

ACM 665

ACM 665

ACM 665

ACM 665

ASBESTOS SURVEY SUMMARY REPORT· RESERVE ENCLAVE BUlWINGS

Material Description

Duct Joinu or Anti-Vibration Material Duct Joinu or Anti-Vibration Material Duct Joinu or Anti-Vibration Material Duct Joinu or Anti-Vibration Material Floor Tile Mastic Floor Tile Mastic Floor Tile Mastic Floor Tile Mastic Floor Tile Mastic Floor Tile Mastic Floor Tile Mastic Floor Tile Mastic Floor Tile Mastic Floor Tile Mastic Floor Tile Mastic Floor Tile Mastic Floor Tile Mastic Floor Tile Mastic Vinyl F1oa- Tile(s)lMatuial Vinyl F1oa- Tile(s)IMatuial Floor Tile Mastic Vinyl F1oa- Tile(s)IMatuial Vinyl F1oa- TIle(s)lMatuial Vinyl F1oa- Tile(s)lMatuial Floor Tile Mastic Vinyl F1oa- Tile(s)IMatuial Floor Tile Mastic Floor Tile Mastic Floor Tile Mastic Vinyl F1oa- Tile(s)lMatuial Vinyl F1oa- Tile(s)lMatuial Floor Tile Mastic Floor Tile Mastic Floor Tile Mastic Floor Tile Mastic Floor Tile Mastic

Assessment ACM I ACM 1 Index (%) Type

E E E E F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F

10 NA

10 NA

10 NA

10 NA

20 CHRYSOTILE

20 REF06A

2 CHRYSOTILE

2 REF03B

2 CHRYSOTILE

2 CHRYSOTILE

2 CHRYSOTILE

10 CHRYSOTILE

10 CHRYSOTILE

20 CHRYSOTILE

20 CHRYSOTILE

20 REF 19A

20 REF23A

10 CHRYSOTILE

10 CHRYSOTILE

10 CHRYSOTILE

10 REF07A

10 REF 18A

10 REF22A

5 CHRYSOTILE

5 CHRYSOTILE

5 REF24A

5 REF25A

10 CHRYSOTILE

10 REF04A

2 CHRYSOTILE

2 REF llA o CHRYSOTILE

10 CHRYSOTILE

10 REF 15A

2 CHRYSOTILE

2 REF 13A

ACM2 ACM2

(%) Type

Material Total

12500

ISO

ISO

ISO

ISO

Total Damage Unit Size o SF NA o SF NA o SF NA o SF NA o SF NA o SF NA o SF NA o SF NA o SF NA o SF NA o SF NA o SF NA o SF NA o SF NA o SF NA o SF NA o SF NA o SF NA

2 SF I'XI'

2 SF I'XI'

o SF NA

2 SF I'XI'

2 SF I'XI'

SF I'XI'

o SF NA

I SF I'XI'

o SF NA o SF NA o SF NA o SF I'XI' o SF I 'XI' o SF NA o SF NA o SF NA o SF NA o SF NA

Color

GRAY

GRAY

GRAY

NA

NA

NA

NA

NA

NA

NA

NA

NA

NA

NA

NA

NA

NA

NA

GREEN

WHITE

NA

GREEN

WHITE

BLACK,WHITE

NA

BLACK,WHITE

NA

BLACK

BLACK

BEIGE

BEIGE

NA

NA

NA

NA

NA

ASBESTOS SURVEY SUMMARY REPORT - RESERVE ENCLAVE BUILDINGS

Material Material Assessment ACMI ACMI ACM2 ACM2 Material Total Oassification Building Description Index (%) Type (%) Type Total Damage Unit Size Color

ACM 666 Floor Tile Mastic F 10 CHRYSOTILE 472 0 SF NA NA ACM 666 Floor Tile Mastic F 10 CHRYSOTILE 230 0 SF NA NA ACM 666 Floor Tile Mastic F 10 REF 15A 230 0 SF NA NA ACM 666 Vinyl Floor Tile(s)IMaterial F 2 CHRYSOTILE 230 0 SF I 'XI' WHITE ACM 666 Vinyl Floor Tile(s)lMaterial F 2 REF 14A 230 0 SF 1 'XI' WHITE ACM 667 Floor Tile Mastic F . 20 CHRYSOTILE 18150 0 SF NA NA ACM 667 Floor Tile Mastic F 20 REF02A 18150 0 SF NA NA ACM 667 Vinyl Floor Tile(s)/Material F 2 CHRYSOTILE 18150 0 SF I'Xl' TAN ACM 667 Vinyl Floor TiIe(s)IMaterial F 2 REFOIB 18150 0 SF I'XI' TAN ACM 668 Floor Tile Mastic F 20 CHRYSOTILE 8944 0 SF NA NA ACM 668 Vinyl Floor Tile(s)/Material F 2 CHRYSOTILE 8944 0 SF I'XI' TAN ACM 669 Floor Tile Mastic F 20 CHRYSOTILE 8944 0 SF NA NA ACM 669 Vinyl Floor Tile(s)IMaterial F 2 CHRYSOTILE 8944 0 SF 1 'XI' TAN ACM 670 Vinyl Floor Tile(s)IMaterial F 30 CHRYSOTILE . 24 3 SF SHEET WHITE ACM 670 Vinyl Floor Tile(s)/M~erial F 30 REF05A 24 3 SF SHEET WHITE ACM 670 Floor Tile Mastic F 20 CHRYSOTILE 18150 0 SF NA NA ACM 670 Vinyl Floor Tile(s)IMaterial F 2 CHRYSOTILE 18150 0 SF I'Xl' TAN ACM 671 Floor Tile Mastic F 10 CHRYSOTILE 2000 0 SF NA BLACK ACM 671 Floor Tile Mastic F 10 CHRYSOTILE 150 0 SF NA BLACK ACM 671 Floor Tile Mastic F 10 REF02A 2000 0 SF NA BLACK ACM 671 Floor Tile Mastic F 10 REF06A 150 0 SF NA BLACK ACM 671 Vinyl Floor Tile(s)lMaterial F 2 CHRYSOTILE 2000 0 SF l'Xl' WHITE ACM 671 Vinyl Floor Tile(s)IMaterial F 2 CHRYSOTILE 150 0 SF I'XI' GRAY ACM 671 Vinyl Floor Tile(s)IMaterial F 2 REFOIA 2000 0 SF I'XI' WHITE ACM 671 Vinyl Floor Tile(s)/Material F 2 REFOSA 150 0 SF I 'XI' GRAY ACM 673 Floor Tile Mastic F 2 CHRYSOTILE 35844 0 SF NA NA ACM 673 Floor Tile Mastic F 2 REF24B 35844 0 SF NA NA ACM 674 Floor Tile Mastic F 10 CHRYSOTILE 1188 0 SF NA NA ACM 675 Floor Tile Mastic F 10 CHRYSOTILE 220 0 SF NA NA ACM 675 Floor Tile Mastic F 10 REF 12A 220 0 SF NA NA ACM 676 Floor Tile Mastic F 10 CHRYSOTILE 2690 0 SF NA NA ACM 676 Floor Tile Mastic F 10 REF02A 2690 0 SF NA NA ACM 676 Vinyl Floor Tile(s)IMaterial F 2 CHRYSOTILE 2690 0 SF I'XI' LIGHT BEIGE ACM 676 Vinyl Floor Tile(s)/Material F 2 REFOlD 2690 0 SF l'Xl' LIGHT BEIGE ACM 683 Vinyl Floor Tile(s)IMaterial F 15 CHRYSOTILE 6636 0 SF 9"X9" VARIOUS ACM 683 Floor Tile Mastic F 10 CHRYSOTILE 6636 0 SF NA BLACK

Material Material Assessment ACMI ACMI ACM2 ACM2 Material Total Oassification Building Description Index (%) Type (%) Type Total Damage Unit Size Color

ACM 685 Vinyl Floor Tile(s)lMaterial F 15 CHRYSOTILE 6492 0 SF 9"X9" VARIOUS ACM 685 Vinyl Floor TIle(s)IMaterial F 15 REFOIA 6492 0 SF 9"X9" VARIOUS ACM 685 Floor Tile Mastic F 10 CHRYSOTILE 6492 0 SF NA NA ACM 685 Floor Tile Mastic F 10 REF02A 6492 0 SF NA NA ACM 685 Floor Tile Mastic F 2 CHRYSOTILE 144 0 SF NA BLACK ACM 685 Floor Tile Mastic F 2 REF08A 144 0 SF NA BLACK ACM 689 Duct Insulation F 20 CHRYSOTILE 860 0 SF NA GRAY ACM 689 Duct Insulation F 20 REF 16A 860 0 SF NA GRAY ACM 694 Floor Tile Mastic F 10 CHRYSOTlLE 196 0 SF NA NA ACM 694 Floor TIle Mastic F 2 CHRYSOTILE 350 0 SF NA NA ACM 695 Floor Tile Mastic F 10 CHRYSOTlLE llOO 0 SF NA NA ACM 697 Floor TIle Mastic F 10 CHRYSOTlLE 126 0 SF NA NA ACM 697 Floor Tile Mastic F 10 REF 13A 126 0 SF NA NA ACM 3411 Floor Tile Mastic F 10 CHRYSOTILE 1010 0 SF NA NA ACM 3411 Floor Tile Mastic F 10 REF04A 1010 0 SF NA NA ACM 3412 Floor Tile Mastic F 10 CHRYSOTILE 1694 0 SF NA NA ACM 3773 Floor Tile Mastic F 25 CHRYSOTILE 365 0 SF NA NA ACM 3773 Floor Tile Mastic F 25 CHRYSOTILE 64 0 SF NA NA ACM 3773 Floor TIle Mastic F 25 REF05A 365 0 SF NA NA ACM 3773 Floor Tile Mastic F 25 REF23A 64 0 SF NA NA ACM 3773 Floor Tile Mastic F 20 CHRYSOTILE 5085 0 SF NA NA ACM 3773 Floor TIle Mastic F 20 REF08A 5085 0 SF NA NA ACM 3773 Floor Tile Mastic F 15 CHRYSOTILE 2652 '0 SF NA NA ACM 3773 Floor Tile Mastic F IS REF 17A 2652 0 SF NA NA ACM 3773 Floor TIle Mastic F 10 CHRYSOTILE 14700 0 SF NA NA ACM 3773 Floor Tile Mastic F 10 REFI5A 14700 0 SF NA NA ACM 3773 Vinyl Floor Tile(s)IMaterial F 5 CHRYSOTILE 365 0 SF I'XI' BElGE.BROWN ACM 3773 Vinyl Floor TIle(s)IMaterial F 5 CHRYSOTILE 5085 0 SF I 'Xl' GRA Y.BLACK.WHIT

E ACM 3773 Vinyl Floor Tile(s)IMaterial F 5 CHRYSOTILE 1250 0 SF I 'Xl' BLACK, WHITE ACM 3773 Vinyl Floor Tile(s)IMaterial F 5 CHRYSOTILE 64 0 SF I 'Xl' DARK TAN ACM 3773 Vinyl Floor TIIe(s)IMaterial F 5 REF04A 365 0 SF I 'Xl' BEIGE. BROWN ACM 3773 Vinyl Floor Tile(s)IMaterial F 5 REF07A 5085 0 SF I 'XI' GRA Y.BLACK.WHlT

E ACM 3773 Vinyl Floor TIle(s)IMaterial F 5 REF 12A 1250 0 SF I 'Xl' BLACK.WHITE ACM 3773 Vinyl Floor Tile(s)IMaterial F 5 REF22A 64 0 SF I'XI' DARK TAN

Material Material Assessment ACMl ACMl ACM2 ACM2 Material Total Qassification Building Description Index (%) Type (%) Type Total Damage Unit Size Color

ACM 3773 Vinyl Floor Tile(s)/Material F 2 CHRYSOTILE 14700 0 SF I 'XI' BEIGE, TAN, WHITE ACM 3773 Vinyl Floor Tile(s)/Material F 2 REF 14A 14700 0 SF I'XI' BEIGE,TAN,WHITE ACM 3774 Vinyl Floor Tile(s)/Material F 2 CHRYSOTILE 275 0 SF l'XI' GRAY ACM 3774 Vinyl Floor Tile(s)/Material F 2 REFOIA 275 0 SF I 'XI' GRAY

ASSUMED-ACM 601 Roofing Sealant F 10 NA 5100 0 SF NA NA ASSUMED-ACM 602 Roofing Sealant F 10 NA 4700 0 SF NA NA ASSUMED-ACM 603 Roofing Sealant F 10 NA 5100 0 SF NA NA ASSUMED-ACM 604 Roofing Sealant F 10 NA 4700 0 SF NA NA ASSUMED-ACM 605 Roofing Sealant F 10 NA 240 0 SF NA NA ASSUMED-ACM 605 Vinyl Floor TIle(s)/Material F 10 NA 20 0 SF 9"X9" TAN ASSUMED-ACM 605 Floor Tile Mastic F 10 NA 20 0 SF NA NA ASSUMED-ACM 606 Roofing Sealant F 10 NA 240 0 SF NA NA ASSUMED-ACM 607 Roofing Sealant F 10 NA 120 0 SF NA NA ASSUMED-ACM 608 Roofing Sealant F 10 NA 120 0 SF NA NA ASSUMED-ACM 612 Roofing Sealant F 10 NA 5100 0 SF NA NA ASSUMED-ACM 613 Roofing Sealant F 10 NA 4700 0 SF NA BLACK ASSUMED-ACM 614 Roofing Sealant F 10 NA 240 0 SF NA NA ASSUMED-ACM 615 Roofing Sealant F 10 NA 120 0 SF NA NA ASSUMED-ACM 616 Roofing Sealant F 10 NA 4700 0 SF NA NA ASSUMED-ACM 617 Roofing Sealant F 10 NA 5100 0 SF NA NA ASSUMED-ACM 618 Roofing Sealant F 10 NA 240 0 SF NA NA ASSUMED-ACM 619 Roofing Sealant F 10 NA 120 0 SF NA NA ASSUMED-ACM 637 Vinyl Floor Tile(s)/Material F 10 NA 32400 0 SF 9"X9" RED,MARooN ASSUMED-ACM 637 Floor Tile Mastic F 10 NA 32400 0 SF NA NA ASSUMED-ACM 637 Roofing Sealant F 10 NA 11700 0 SF NA BLACK ASSUMED-ACM 638 Vinyl Floor TIle(s)/Material F 10 NA 32400 0 SF 9"X9" VARIOUS ASSUMED-ACM 638 Floor Tile Mastic F 10 NA 32400 0 SF NA NA ASSUMED-ACM 638 Roofing Sealant F 10 NA 11700 0 SF NA BLACK ASSUMED-ACM 640 Roofing Sealant F 10 NA 2405 0 SF NA NA ASSUMED-ACM 641 Vinyl Floor Tile(s)/Material F 10 NA 45000 25 SF 9"X9" TAN,MARooN ASSUMED-ACM 641 Floor Tile Mastic F 10 NA 45000 0 SF NA NA ASSUMED-ACM 641 Fire Door Insulation F 10 NA 38 () EA NA NA ASSUMED-ACM 641 Roofing Sealant F 10 NA 17000 0 SF NA NA ASSUMED-ACM 642 Vinyl Floor Tile(s)/Malerial F 10 NA 45000 25 SF 9"X9" VARIOUS ASSUMED-ACM 642 Floor Tile Mastic F 10 NA 45000 0 SF NA NA ASSUMED-ACM 642 Fire Door Insulation F 10 NA 36 0 EA NA NA

Classification Building

ASSUMED-ACM 642

ASSUMED-ACM 643

ASSUMED-ACM 643

ASSUMED-ACM 643

ASSUMED-ACM 644

ASSUMED-ACM 644

ASSUMED-ACM 644

ASSUMED-ACM 644

ASSUMED-ACM 646

ASSUMED-ACM 646

ASSUMED-ACM 646

ASSUMED-ACM 653

ASSUMED-ACM 653

ASSUMED-ACM 653

ASSUMED-ACM 656

ASSUMED-ACM 656

ASSUMED-ACM 656

ASSUMED-ACM 657

ASSUMED-ACM 657

ASSUMED-ACM 658

ASSUMED-ACM 658

ASSUMED-ACM 665

• ASSUMED-ACM 665

ASSUMED-ACM 666

ASSUMED-ACM 666

ASSUMED-ACM 666

ASSUMED-ACM 666

ASSUMED-ACM 667

ASSUMED-ACM 667

ASSUMED-ACM 667

ASSUMED-ACM 667

ASSUMED-ACM 667

ASSUMED-ACM 668

ASSUMED-ACM 668

ASSUMED-ACM 668

ASSUMED-ACM 668

ASBESTOS SURVEY SUMMARY REPORT - RESERVE ENCLAVE BUILDINGS

Material Description

Roofing Sealant

Vinyl F100c Tile(s)IMaterial

Floor Tile Mastic Roofing Sealant Vinyl F100c TIle(s)lMaterial Floor Tile Mastic Fire Dooc Insulation Roofing Sealant Roofing Sealant Vinyl F100c TIIe(s)IMaterial Floor TIle Mastic Roofing Sealant

Vinyl F100c Tile(s)lMaterial

Floor Tile Mastic Roofing Sealant Vinyl F100c TIIe(s)IMaterial

Floor Tile Mastic Roofing Sealant Fire Dooc Insulation Fire Door Insulation Roofing Sealant Roofing Sealant Fire Door Insulation Vinyl F100c Tile(s)lMaterial Floor TIle Mastic Fire Dooc Insulation Roofing Sealant Ceiling Tile(s) - (2'x 4') Ceiling Board - Transite (or Similar Material) Fire Door Insulation Roofing Sealant Asbestos Transite Panel(s) Ceiling Tile(s) - (2'x 4')

Fire Dooc Insulation

Roofing Sealant Asbestos Transite Panel(s)

Assessment ACM 1 ACMl Type Index (%)

F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F

10 NA

10 NA

10 NA

10 NA

10 NA

10 NA

10 NA

10 NA

10 NA

10 NA

10 NA

10 NA

10 NA

10 NA

10 NA

10 NA

10 NA

10 NA

10 NA

10 NA

10 NA

10 NA

10 NA

10 NA

10 NA

10 NA

10 NA

10 NA

10 NA

10 NA

10 NA

10 NA

10 NA

10 NA

10 NA

10 NA

ACM2 ACM2

(%) Type

Material Total

17634

45000 45000

17634 12130

12130

12130 12000 12000 12412

13248 13618

34361 34361

15144

Total Damage Unit Size o SF NA o SF 9"X9" o SF NA o SF NA

80 SF 9"X9"

o SF NA o EA NA o SF NA o SF NA

10 SF 9"X9"

o SF NA o SF NA

10 SF 9"X9"

o SF NA o SF NA

10 SF 9"X9"

o SF NA o SF NA o EA NA o EA NA o SF NA o SF NA o EA NA o SF 9"X9" o SF NA o EA NA o SF NA o SF 2'X4' o SF NA o , EA NA o SF NA o SF NA o SF 2'X4' o EA NA o SF NA o SF NA

Color

BLACK

TAN,WHITE

NA

NA

TAN, MAROON

NA

NA

BLACK

BLACK

RED,MARooN

BLACK

BLACK

RED,MARooN

BLACK

BLACK

RED,MARooN

BLACK

BLACK

NA

BROWN

GRAY

BLACK

NA

VARIOUS

NA

METAL

BLACK

WHITE

GREEN

METAL

BLACK

VARIOUS

WHITE

METAL

BLACK

VARIOUS

Material Material Assessment ACMl ACMl ACM2 ACM2 Material Total Oassification Building Description Index (%) Type (%) Type Total Damage Unit Size Color

ASSUMED-ACM 669 Ceiling Tile(s) • (2'x 4') F 10 NA 345 0 SF 2'X4' WHITE .-\SSUMED-ACM 669 Fire Door Insulation F 10 NA 8 0 EA NA METAL ASSUMED-ACM 669 Roofing Sealant F 10 NA 3088 0 SF NA BLACK ASSUMED-ACM 669 Asbestos Transite Panel(s) F 10 NA 1090 0 SF NA VARIOUS ASSUMED-ACM 670 Ceiling Tile(s)· (2'x 4') F 10 NA 720 0 SF 2'X4' WHITE ASSUMED-ACM 670 Ceiling Board· Transite (or Similar Material) F 10 NA 142 0 SF NA GREEN ASSUMED-ACM 670 Fire Door Insulation F 10 NA 14 0 EA NA METAL ASSUMED-ACM 670 Roofing Sealant F 10 NA 6380 0 SF NA BLACK ASSUMED-ACM 670 Asbestos Transite Panel(s) F 10 NA 2306 0 SF NA VARIOUS ASSUMED-ACM 671 Roofing Sealant F 10 NA 5484 0 SF NA BLACK ASSUMED-ACM 673 Fire Door Insulation F 10 NA 86 0 EA NA METAL. WOOD ASSUMED-ACM 673 Roofing Sealant F 10 NA 15144 0 SF NA BLACK ASSUMED-ACM 674 Vinyl Floor Tile(s)lMaterial F 10 NA 32280 0 SF 9"X9" VARIOUS ASSUMED-ACM 674 Floor Tile Mastic F 10 NA 32280 0 SF NA NA ASSUMED-ACM 674 Fire Door Insulation F 10 NA 86 0 EA NA METAL. WOOD ASSUMED-ACM 674 Roofing Sealant F 10 NA 15144 0 SF NA BLACK ASSUMED-ACM 675 Vinyl Floor Tile(s)IMaterial F 10 NA 2650 10 SF 9"X9" NA ASSUMED-ACM 675 Floor Tile Mastic F 10 NA 2650 0 SF NA NA ASSUMED-ACM 675 Roofing Sealant F 10 NA 3520 0 SF NA NA ASSUMED-ACM 676 Vinyl Floor Tile(s)lMaterial F 10 NA 130 60 SF 9"X9" NA ASSUMED-ACM 676 Floor Tile Mastic F 10 NA 130 60 SF NA NA ASSUMED-ACM 676 Roofing Sealant F 10 NA 3516 0 SF NA NA ASSUMED-ACM 671 Vinyl Floor Tile(s)lMaterial F 10 NA 2816 0 SF 9"X9" VARIOUS ASSUMED-ACM 671 Floor Tile Mastic F 10 NA 2816 0 SF NA NA ASSUMED-ACM 671 Roofing Sealant F 10 NA 6150 0 SF NA NA ASSUMED-ACM 678 Roofing Sealant F 10 NA 12130 0 SF NA BLACK ASSUMED-ACM 678 Vinyl Floor Tile(s)lMaterial F 10 NA 4310 10 SF 9"X9" RED. MAROON ASSUMED-ACM 678 Floor Tile Mastic F 10 NA 4310 0 SF NA BLACK ASSUMED-ACM 678 Duct Joiner or Anti-Vibration Material F 10 NA 28 0 SF NA GRAY ASSUMED-ACM 679 Vinyl Floor Tile(s)lMaterial F 10 NA 4620 0 SF 9"X9" VARIOUS ASSUMED-ACM 679 Floor Tile Mastic F 10 NA 4620 0 SF NA NA ASSUMED-ACM 679 Roofing Sealant F 10 NA 6150 0 SF NA NA ASSUMED-ACM 680 Vinyl Floor Tile(s)IMaterial F 10 NA 8717 0 SF 9"X9" VARIOUS ASSUMED-ACM 680 Floor Tile Mastic F 10 NA 8717 0 SF NA NA ASSUMED-ACM 680 Fire Door Insulation F 10 NA 7 0 EA NA NA ASSUMED-ACM 680 Roofing Sealant F 10 NA 3250 0 SF NA BLACK

C\ assification Building Description Index (%) Type (%) Type Total Damage Unit Size Color

ASSUMED-ACM 681 Vinyl Floor Tile(s}IMaterial F 10 NA 3330 0 SF 9"X9" TAN ASSUMED-ACM 681 Floor TIle Mastic F 10 NA 3330 0 SF 9"X9" VARIOUS ASSUMED-ACM 681 Roofing Sealant F 10 NA 4060 0 SF NA NA ASSUMED-ACM 683 Roofing Sealant F 10 NA 8060 0 SF NA BLACK. ASSUMED-ACM 684 Vinyl Floor Tile(s)lMaterial F 10 NA 2784 0 SF 9"X9" VARIOUS ASSUMED-ACM 684 Floor TIle Mastic F 10 NA 2784 0 SF NA NA ASSUMED-ACM 684 Roofing Sealant F 10 NA 6150 0 SF NA NA ASSUMED-ACM 685 Roofing Sealant F 10 NA 8060 0 SF NA BLACK ASSUMED-ACM 686 Vinyl Floor Tile(s)IMaterial F 10 NA 7160 10 SF 9"X9" VARIOUS ASSUMED-ACM 686 Floor TIle Mastic F 10 NA 7160 0 SF NA NA ASSUMED-ACM 686 Fire Door Insulation F 10 NA 9 0 EA NA NA ASSUMED-ACM 686 Roofing Sealant F 10 NA 3250 0 SF NA BLACK ASSUMED-ACM 687 Vinyl Floor Tile(s)lMaterial F 10 NA 4620 8 SF 9"X9" VARIOUS ASSUMED-ACM 687 Floor Tile Mastic F 10 NA 4620 0 SF NA NA ASSUMED-ACM 687 Roofing Sealant F 10 NA 6150 0 SF NA NA ASSUMED-ACM 688 Roofing Sealant F 10 NA 12130 0 SF NA BLACK ASSUMED-ACM 688 Vinyl Floor TIIe(s}IMaterial F 10 NA 3796 0 SF 9"X9" TAN,BROWN ASSUMED-ACM 688 Floor TIle Mastic F 10 NA 3796 0 SF NA BLACK ASSUMED-ACM 689 Roofing Sealant F 10 NA 12130 0 SF NA BLACK ASSUMED-ACM 689 Vinyl Floor Tile(s)lMaterial F 10 NA 4013 0 SF 9"X9" RED,MARooN ASSUMED-ACM 689 Floor Tile Mastic F 10 NA 4013 0 SF NA BLACK ASSUMED-ACM 693 Vinyl Floor Tile(s}IMaterial F 10 NA 34361 0 SF 9"X9" VARIOUS ASSUMED-ACM 693 Floor Tile Mastic F 10 NA 34361 0 SF NA NA ASSUMED-ACM 693 Fire Door Insulation F 10 NA 8 0 EA NA METAL ASSUMED-ACM 693 Roofing Sealant F 10 NA 15144 0 SF NA BLACK ASSUMED-ACM 694 Roofing Sealant F 10 NA 12412 0 SF NA BLACK ASSUMED-ACM 694 Fire Door Insulation F 10 NA 10 0 EA NA NA ASSUMED-ACM 695 Vinyl Floor Tile(s}IMaterial F 10 NA 60 60 SF 9"X9" VARIOUS ASSUMED-ACM 695 Floor Tile Mastic F 10 NA 34361 0 SF NA NA ASSUMED-ACM 695 Fire Door Insulation F 10 NA 113 0 EA NA METAL, WOOD ASSUMED-ACM 695 Roofing Sealant F cc c_, ___ ~~, • .1L~_, _______ , __ .. _.,_. ___ . _______ .,.~_.llHi _____ . __ .o_._SL...NA __ BLACK ..

SU ED-A 696 Roofing Sealant------.----.----- -,"--.-.-'~ -.. -------. -p-'" 10 NA 13033 0 SF NA BLACK SSUMED-ACM 696 Vinyl Floor TIle(s)lMaterial F 10 NA 4112 0 SF 9"X9" VARIOUS

,ASSUMED-ACM 696 Floor Tile Mastic F 10 NA 4112 0 SF NA NA ASSUMED-ACM 6?6/ Fire Door Insulation F 10 NA 10 0 E~_..NA . __ ~!> __

ASSUMED-ACM 697 Vinyl Floor TIIe(s)IMaterial F 10 NA 39000 0 SF 9"X9" VARIOUS

ASBESTOSSURVEYS~RYREPORT·RESERVEENCLAVEBU1LDINGS

Classification Building Description Index (%) Type (%) Type Total Damage Unit Size Color

ASSUMED-ACM 697 Floor Tile Mastic F 10 NA 39000 0 SF NA NA ASSUMED-ACM 697 Fire Door Insulation F 10 NA 86 0 EA NA METAL, WOOD ASSUMED-ACM 697 Roofing Sealant F 10 NA 15144 0 SF NA BLACK ''lSUMED-ACM 2008 Roofing Sealant F 10 NA 3217 0 SF NA BLACK

;UMED-ACM 3773 Roofing Sealant F 10 NA 51500 0 SF NA NA AS;SUMED-ACM 3774 Roofing Sealant F 10 NA 3850 0 SF NA NA

ASBESTOS SURVEY SUMMARY REPORT - BUILDINGS STRUCTURALLY SIMILAR TO, BUT NOT INCLUDED WITH RESERVE ENCLAVE BUILDINGS

Material Material Assessment ACM I ACM I ACM2 ACM2 Material Total Classification Building Description Index (%) Type (%) Type Total Damage Unit Size Color

ACM 647 Magnesia/Calciform Pipe InsuLon Steam Heating Line(s) C 40 CHRYSOTILE 20 AMOSITE 24 6 LF <6" WHITE ACM 647 Low Temperature Tank Insulation- Magnesia/Calciform C 30 CHRYSOTILE 486 65 SF NA NA ACM 647 Magnesia/Calciform Pipe Insul.on Steam Heating Line(s) C 30 CHRYSOTILE 20 AMOSITE 24 6 LF <6" WHITE ACM 647 Low Temperature Tank Insulation- Magnesia/Calciform C 20 CHRYSOTILE 486 65 SF NA NA

ACM 651 Low Temperature Tank Insulation- Magnesia/Calciform C 30 CHRYSOTILE 486 75 SF NA WHITE

ACM 651 Low Temperature Tank Insulation- Magnesia/Calciform C 20 CHRYSOTILE 486 75 SF NA WHITE

ACM 652 Pipe Fitting(s) on Non-Asbestos Pipe Runs C 20 CHRYSOTILE 889 42 EA <6" WHITE

ACM 652 Pipe Fitting(s) on Non-Asbestos Pipe Runs C 20 REF04C 889 42 EA <6" WHITE

ACM 652 Pipe Fitting(s) on Non-Asbestos Pipe Runs C 20 REF04C 889 42 EA <6" WHITE

ACM 692 Low Temperature Tank Insulation - Aircell C 60 CHRYSOTILE 167 8 SF NA GRAY

ACM 692 Low Temperature Tank Insulation - Aircell C 60 REFOIA 167 8 SF NA GRAY

ACM 692 Low Temperature Tank Insulation - Aircell C 60 REFOIA 167 8 SF NA GRAY

ACM 647 Fitting(s) on Medium Pressure Steam Lines - Asbestos Runs D 40 CHRYSOTILE 20 AMOSITE 23 4 EA <6" WHITE

ACM 647 Fitting(s) on Medium Pressure Steam Lines - Asbestos Runs D 30 CHRYSOTILE 20 AMOSITE 23 4 EA <6" WHITE

ACM 647 Pipe Fitting(s) on Non-Asbestos Pipe Runs D 30 CHRYSOTILE 993 48 EA <6" WHITE

ACM 647 Pipe Fitting(s) on Non-Asbestos Pipe Runs D 20 CHRYSOTILE 993 48 EA <6" WHITE

ACM 648 Magnesia/Calciform Pipe InsuLon Steam Heating Line(s) D 30 CHRYSOTILE 20 AMOSITE 42 6 LF <6" WHITE

ACM 648 Pipe Fitting(s) on Non-Asbestos Pipe Runs D 30 CHRYSOTILE 1005 48 EA <6" WHITE

ACM 648 Magnesia/Calciform Pipe InsuLon Steam Heating Line(s) D 30 REF02A 20 REF02A 42 6 LF <6" WHITE

ACM 648 Magnesia/Calciform Pipe InsuLon Steam Heating Line(s) D 30 REF02A 20 REF02A 42 6 LF <6" WHITE

ACM 648 Fitting(s) on Medium Pressure Steam Lines - Asbestos Runs D 30 REF02A 20 REF02A 30 4 EA <6" WHITE

ACM 648 Fitting(s) on Medium Pressure Steam Lines - Asbestos Runs D 30 REF02A 20 REF02A 30 4 EA <6" WHITE

ACM 648 Fitting(s) on Medium Pressure Steam Lines - Asbestos Runs D 30 REF02A 20 REF02A 30 4 EA <6" WHITE

ACM 648 Pipe Fitting(s) on Non-Asbestos Pipe Runs D 30 REF04A 1005 48 EA <6" WHITE

ACM 648 Pipe Fitting(s) on Non-Asbestos Pipe Runs D 30 REF04A 1005 48 EA <6" WHITE

ACM 648 Low Temperature Tank Insulation- Magnesia/Calciform D 20 CHRYSOTILE 486 0 SF NA WHITE

ACM 648 Low Temperature Tank Insulation- Magnesia/Calciform D 20 REFOIB 486 0 SF NA WHITE

ACM 648 Low Temperature Tank Insulation- Magnesia/Calciform D 20 REFOIB 486 0 SF NA WHITE

AC,1 651 Magnesia/Calciform Pipe InsuLon Stearn Heating Line(s) D 40 CHRYSOTILE 20 AMOSITE 38 4 LF <6" WHITE

ACM 651 Fitting(s) on Medium Pressure Stearn Lines - Asbestos Runs D 40 CHRYSOTILE 20 AMOSITE 36 4 EA <6" WHITE

ACM 651 Magnesia/Calciform Pipe InsuLon Stearn Heating Line(s) D 30 CHRYSOTILE 20 AMOSITE 38 4 LF <6" WHITE

ACM 651 Fitting(s) on Medium Pressure Stearn Lines - Asbestos Runs D 30 CHRYSOTILE 20 AMOSITE 36 4 EA <6" WHITE

ACM 651 Pipe Fiuing(s) on Non-Asbestos Pipe Runs D 30 CHRYSOTILE 1138 58 EA <6" WHITE

ACM 651 Pipe Fitting(s) on Non-Asbestos Pipe Runs D 20 CHRYSOTILE 1138 58 EA <6" WHITE

ASBESTOS SURVEY SUMMARY REPORT - BUILDINGS STRUCTURALLY SIMILAR TO, BUT NOT INCLUDED WITH RESERVE ENCLAVE BUILDINGS

Material Material Assessment ACM 1 ACM 1 ACM2 ACM2 Material Total Classification Building Description Index (%) Type (%) Type Total Damage Unit Size Color

ACM 652 Magnesia/Calciform Pipe Insul.on Steam Heating Line(s) D 40 CHRYSOTILE 20 AMOSITE 39 6 LF <6" WHITE ACM 652 Magnesia/Calciform Pipe Insul.on Steam Heating Line(s) D 40 REF02A 20 REF02A 39 6 LF <6" WHITE ACM 652 Magnesia/Calciform Pipe Insul.on Steam Heating Line(s) D 40 REF02A 20 REF02A 39 6 LF <6" WHITE ACI1 652 Fiuing(s) on Medium Pressure Steam Lines - Asbestos Runs D 40 REF02A 20 REF02A 31 6 EA <6" WHITE ACM: 652 Fiuing(s) on Medium Pressure Steam Lines - Asbestos Runs D 40 REF02A 20 REF02A 31 6 EA <6" WHITE

ACM 652 Fiuing(s) on Medium Pressure Steam Lines - Asbestos Runs D 40 REF02A 20 REF02A 31 6 EA <6" WHITE

ACM 655 Low Temperature Tank Insulation- Magnesia/Calciform 0 30 CHRYSOTILE 480 0 SF NA WHITE, GRAY

CORE

ACM 655 Pipe Fiuing(s) on Non-Asbestos Pipe Runs 0 30 CHRYSOTILE 654 10 EA <6" GRAY

ACM 655 Low Temperature Tank Insulation- Magnesia/Calciform 0 20 CHRYSOTILE 480 0 SF NA WHITE, GRAY

CORE

ACM 655 Pipe Fiuing(s) on Non-Asbestos Pipe Runs D 20 CHRYSOTILE 654 10 EA <6" GRAY

ACM 690 Pipe FiUing(s) on Non-Asbestos Pipe Runs D 10 CHRYSOTILE 110 5 EA <6" GRAY

ACM 690 Heat Exchanger Insulation- Magnesia/Calciform 0 10 CHRYSOTILE 6 3 SF NA GRAY

ACM 690 Pipe FiUing(s) on Non-Asbestos Pipe Runs D 10 REF09A 110 5 EA <6" GRAY

ACM 690 Pipe Fitting(s) on Non-Asbestos Pipe Runs 0 10 REF09A 110 5 EA <6" GRAY

ACM 690 Heat Exchanger Insulation- Magnesia/Calciform D 10 REF lOA 6 3 SF NA GRAY

ACM 690 Heat Exchanger Insulation- Magnesia/Calciform D 10 REF lOA 6 3 SF NA GRAY

ACM 692 Heat Exchanger Insulation- Magnesia/Calciform D 70 CHRYSOTILE 20 0 SF NA WHITE

ACM 692 Heat Exchanger Insulation- Magnesia/Calciform D 70 REF03A 20 0 SF NA WHITE

ACM 692 Heat Exchanger Insulation- Magnesia/Calciform D 70 REF03A 20 0 SF NA WHITE

ACM 692 Pipe Fitting(s) on Heating HotWater Lines - Non-Asb. Runs D 10 CHRYSOTILE 182 12 EA <6" WHITE

ACM 692 Pipe Fitting(s) on Heating HotWater Lines - Non-Asb. Runs D 10 REF02A 182 12 EA <6" WHITE

ACM 692 Pipe Fitting(s) on Heating HotWater Lines - Non-Asb. Runs 0 10 REF02A 182 12 EA <6" WHITE

ACM 2517 Pipe Fitting(s) on Pipe of Unknown Function-Non-Asb. Runs D 10 CHRYSOTILE 7 3 EA < I" GRAY

ACM 2517 Pipe Fitting(s) on Pipe of Unknown Function-Non-Asb. Runs D 10 REF 01A 7 3 EA < I" GRAY

ACM 2517 Pipe Fitting(s) on Pipe of Unknown Function-Non-Asb. Runs D 10 REFOIA 7 3 EA <I" GRAY

ASSUMED-ACM 647 Duct Joiner or Anti-Vibration Material D 10 NA 64 0 SF NA WHITE

ASSUMEO-ACM 647 Rope Gasket D 10 NA 324 0 LF NA WHITE

ASSUMEO-ACM 648 Ouct Joiner or Anti-Vibration Material 0 10 NA 32 0 SF NA WHITE

ASSUMEO-ACM 648 Ouct Joiner or Anti-Vibration Material D 10 NA 324 0 LF NA WHITE

ASSUMEO-ACM 651 Ouct Joiner or Anti-Vibration Material 0 10 NA 48 0 SF NA WHITE

ASSUMED-ACM 651 Rope Gasket D 10 NA 324 0 LF NA WHITE

ASSUMED-ACM 652 Duct Joiner or Anti-Vibration Material 0 10 NA 40 0 SF NA WHITE

ASBESTOS SURVEY SUMMARY REPORT - BUILDINGS STRUCTURALLY SIMILAR TO, BUT NOT INCLUDED WITH RESERVE ENCLAVE BUILDINGS

Material Material Assessment ACM I ACM I ACM2 ACM2 Material Total Classification Building Description Index (%) Type (%) Type Total Damage Unit Size Color

ASSUMED-ACM 652 Rope Gasket D 10 NA 324 0 LF NA WHITE

ASSUMED-ACM 655 Duct Joiner or Anti-Vibration Material D 10 NA 64 0 SF NA WHITE

ASSUMED-ACM 655 Rope Gasket D 10 NA 300 0 LF NA WHITE

ASSUMED-ACM 692 Duct Joiner or Anti-Vibration Material D 10 NA 28 0 SF NA WHITE

ACM 652 Low Temperature Tank Insulation- Magnesia/Calciform E 30 CHRYSOTILE 486 10 SF NA WHITE

ACM 652 Low Temperature Tank Insulation- Magnesia/Calciform E 30 REF OIA 486 10 SF NA WHITE

ACM 652 Low Temperature Tank Insulation- Magnesia/Calciform E 30 REFOIA 486 10 SF NA WHITE

ACM 691 Heat Exchanger Insulation- Magnesia/Calciform E 60 CHRYSOTILE 6 0 SF NA GRAY

ACM 691 Heat Exchanger Insulation- Magnesia/Calciform E 60 REF llA 6 0 SF NA GRAY

ACM 691 Heat Exchanger Insulation- Magnesia/Calciform E 60 REF llA 6 0 SF NA GRAY

ACM 691 Pipe Fitting(s) on Non-Asbestos Pipe Runs E 10 CHRYSOTILE 103 2 EA <6" GRAY

ACM 691 Pipe Fitting(s) on Non-Asbestos Pipe Runs E 10 REF lOA 103 2 EA <6" GRAY

ACM 691 Pipe Fitting(s) on Non-Asbestos Pipe Runs E 10 REF lOA 103 2 EA <6" GRAY

ASSUMED-ACM 690 Duct Joiner or Anti-Vibration Material E 10 NA 16 0 SF NA GRAY

ASSUMED-ACM 691 Duct Joiner or Anti-Vibration Material E 10 NA 18 0 SF NA GRAY

ACM 649 Vinyl Floor Tile(s)lMaterial F 2 CHRYSOTILE 80 0 SF I'XI' WHITE,BLACK

ACM 649 Vinyl Floor Tile(s)lMaterial F 2 REF 21A 80 0 SF I'XI' WHITE,BLACK

ACM 655 Vinyl Floor Tile(s)lMaterial F 2 CHRYSOTILE 384 0 SF I'XI' WHITE,BROWN

ACM 655 Vinyl Floor Tile(s)lMaterial F 2 REF17A 384 0 SF I'XI' WHITE,BROWN

ACM 690 Floor Tile Mastic F 5 CHRYSOTILE 156 0 SF NA BLACK

ACM 690 Floor Tile Mastic F 5 REF06A 156 0 SF NA BLACK

ACM 690 Floor Tile Mastic F 2 CHRYSOTILE 156 0 SF NA BLACK

ACM 690 Floor Tile Mastic F 2 REF08B 156 0 SF NA BLACK

ACM 692 Floor Tile Mastic F 2 CHRYSOTILE 300 0 SF NA NA

ACM 692 Floor Tile Mastic F 2 REF lOA 300 0 SF NA NA

ASSUMED-ACM 647 Vinyl Floor Tile(s)lMaterial F 10 NA 47355 0 SF 9"X9" VARIOUS

ASSUMED-ACM 647 Floor Tile Mastic F 10 NA 47355 0 SF NA NA

ASSUMED-ACM 647 Roofing Paper I Tar F 10 NA 13592 0 SF NA NA

ASSUMED-ACM 647 Fire Door Insulation F 10 NA 109 0 EA NA NA

ASSUMED-ACM 648 Vinyl Floor Tile(s)lMaterial F 10 NA 47300 0 SF 9"X9" VARIOUS

ASSUMED-ACM 648 Floor Tile Mastic F 10 NA 47300 0 SF NA NA

ASSUMED-ACM 648 Roofing Paper I Tar F 10 NA 13592 0 SF NA NA

ASSUMED-ACM 648 Fire Door Insulation F 10 NA 109 0 EA NA NA

ASSUMED-ACM 649 Roofing Sealant F 10 NA 13033 0 SF NA BLACK

ASBESTOS SURVEY SUMMARY REPORT - BUILDINGS STRUCTURALLY SIMILAR TO, BUT NOT INCLUDED WITH RESERVE ENCLAVE BUILDINGS

Classification Building Description Index (%) Type (%) Type Total Damage Unit Size Color

ASSUMED-ACM 649 Fire Door Insulation F 10 NA 10 0 EA NA NA

ASSUMED-ACM 650 Roofing Sealant F 10 NA 13033 0 SF NA BLACK

ASSUMED-ACM 650 Vinyl Floor Tile(s)lMaterial F 10 NA 4818 6 SF 9"X9" VARIOUS

ASSUMED-ACM 650 Floor Tile Mastic F 10 NA 4818 0 SF NA NA

ASSUMED-ACM 650 Fire Door Insulation F 10 NA 10 0 EA NA NA

ASSUMED-ACM 651 Vinyl Floor Tile(s)lMaterial F 10 NA 47800 0 SF 9"X9" VARIOUS

ASSUMED-ACM 651 Floor Tile Mastic F 10 NA 47800 0 SF NA NA

ASSUMED-ACM 651 Roofing Paper I Tar F 10 NA 13592 0 SF NA NA

ASSUMED-ACM 651 Fire Door Insulation F 10 NA 109 0 EA NA NA

ASSUMED-ACM 652 Vinyl Floor Tile(s)lMaterial F 10 NA 47800 0 SF 9"X9" VARIOUS

ASSUMED-ACM 652 Floor Tile Mastic F 10 NA 47800 0 SF NA NA

ASSUMED-ACM 652 Roofing Paper I Tar F 10 NA 13592 0 SF NA NA

ASSUMED-ACM 652 Fire Door Insulation F 10 NA 109 0 EA NA NA

ASSUMED-ACM 655 Vinyl Floor Tile(s)lMaterial F 10 NA 33480 0 SF 9"X9" VARIOUS

ASSUMED-ACM 655 Floor Tile Mastic F 10 NA 33480 0 SF NA NA

ASSUMED-ACM 655 Roofing Paper I Tar F 10 NA 12060 0 SF NA NA

ASSUMED-ACM 655 Fire Door Insulation F 10 NA 101 0 EA NA NA

ASSUMED-ACM 690 Roofing Sealant F 10 NA 5238 0 SF NA NA

ASSUMED-ACM 691 Vinyl Floor Tile(s)lMaterial F 10 NA 3090 0 SF 9"X9" TAN

ASSUMED-ACM 691 Floor Tile Mastic F 10 NA 3090 0 SF NA NA

ASSUMED-ACM 691 Roofing Sealant F 10 NA 4060 0 SF NA BLACK

ASSUMED-ACM 692 Vinyl Floor Tile(s)lMaterial F 10 NA 1585 4 SF 9"X9" TAN,BROWN

ASSUMED-ACM 692 Floor Tile Mastic F 10 NA 1585 0 SF NA NA

ASSUMED-ACM 692 Asphalt Roof Shingle(s) F 10 NA 25000 0 SF NA BLACK

ASSUMED-ACM 2517 Roofing Sealant F 10 NA 2 0 SF NA BLACK

ASBESTOS SURVEY SUMMARY REPORT - BARNUM ROAD AND INDUSTRIAL AREA BUILDINGS

Classification Building Description Index (%) Type (%) Type Total Damage Unit Size Color

ACM 1400 Magnesia/Calciform Pipe Insul.on Hot Water Heating Line(s) B 60 AMOSITE 2 CHRYSOTILE 4970 12…