KGS_2018d_Area_of_Contamination_50_2018_Injection_Program_Summary_Devens.pdf
PDF 999 KB Posted
- Solicitation number
- W912WJ19R0003
About this file
KGS 2018d Area_of_Contamination_50_2018_Injection_Program_Summary Devens
View the file
Other files
Show all 47
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
KOMAN Government Solutions, LLC Phone (508) 366-7442 293 Boston Post Road West, Suite 100 Fax (508) 366-7445 Marlborough, Massachusetts 01752 www.komangs.com
June 11, 2018
U.S. Army Corps of Engineers New England District 696 Virginia Road Concord, MA 01742-2571 Attn: Ms. Penelope Reddy
Subject: Area of Contamination (AOC) 50, 2018 Injection Program Summary Former Fort Devens Army Installation, Devens, MA Contract No. W912WJ-18-C-0011
Dear Ms. Reddy, On behalf of the U.S. Army Corps of Engineers (USACE) New England District and the U.S. Army BRAC Environmental Office Fort Devens, this letter provides a summary of the planned 2018 enhanced reductive dechlorination (ERD) injection program. The injection program is planned to be conducted during summer 2018. As such, agency review is requested within 60 days per the AOC 50 Long-Term Monitoring and Maintenance Plan (KGS, October 2017), or sooner if possible.
The 2018 injection program consists of an organic carbon substrate injected into selected existing injection wells and direct injections of an organic carbon substrate containing zero valent iron into the subsurface via direct push technology. The program includes injecting substrate into up to 10 existing injection wells and conducting direct injections in up to 30 locations. Approximately 29,680 gallons of organic substrate will be injected into the subsurface in order to promote ERD of the chlorinated volatile organic compound (CVOC) plume in groundwater.
Direct injections will be conducted in AOC 50 Area 1 at the Former Drum Storage Area by monitoring well G6M-07-02X, in Area 1 near the parachute building (T3803) around well G6M-13-05X, in Area 3 upgradient of well G6M-04-02X, and west of Area 5 upgradient of well G6M-97-05B. Injections will also be conducted at existing injection wells in Area 3, Area 4 (to treat the solvent mass in Area 4 detected at G6M-02-13X), and Area 5 (to treat the solvent mass upgradient of G6M-13-04X).
The planned locations, specific substrate, approximate gallons, and planned depths are listed in Table 1.
The injection wells and approximate area of the planned direct injections are shown on Figure 1, which also shows Fall 2017 PCE concentrations and contours. The actual injections may differ from the plan based on field conditions. A summary of the injection program will be provided in the AOC 50 2018 Annual Report.
Please contact me at (508) 219-6771 or jropp@komangs.com if you have any questions.
Sincerely, KOMAN Government Solutions, LLC
James Ropp, P.E.
Project Manager
KOMAN Government Solutions, LLC Subsidiary of the Natives of Kodiak
Attachment: Table 1 AOC 50 2018 Injection Program
Figure 1 Injection Locations & Tetrachloroethene Concentration in Groundwater – October 2017, AOC 50 cc: Robert Simeone, BRAC Devens, MA Dan Groher, USACE Mike Kulbersh, USACE Carol Keating, EPA Region 1
Laurie O'Connor, EPA Region 1 David Chaffin, MassDEP Ron Ostrowski, MassDevelopment Sgt. Brian Lee, Mass. State Police
Laurie Nehring, PACE Julie Corenzwit, PACE Richard Doherty, Engineering and Consulting Resources, Inc.
KGS File
Table 1 AOC 50 2018 ERD Injection Program
Former Fort Devens Army Installation, Devens, MA
Location Location AOC 50 Injection Product Pounds of Percent Injection Injection Type Area (and water) Product Weight Volume (gal) Depth (ft bgs)*
IW-27 Injection Well Area 3 ABC+Ole' 450 70 - 90 IW-26 Injection Well Area 3 ABC+Ole' 450 70 - 90 IW-25 Injection Well Area 3 ABC+Ole' 450 70 - 90 IW-29 Injection Well Area 4 ABC+Ole' 450 105 - 125 IW-30 Injection Well Area 4 ABC+Ole' 450 105 - 125 IW-31 Injection Well Area 4 ABC+Ole' 450 100 - 120 IW-32 Injection Well Area 4 ABC+Ole' 450 95 - 115 IW-6 Injection Well Area 5 ABC+Ole' 450 115 - 135
IW-39 Injection Well Area 5 ABC+Ole' 450 125 - 145 G6M-02-05X Injection Well Area 5 ABC+Ole' 450 120 - 135
GP-58 DPT Injection ABC+Ole'+Fe 860 18 - 46 GP-59 DPT Injection ABC+Ole'+Fe 860 18 - 46 GP-60 DPT Injection ABC+Ole'+Fe 860 18 - 46 GP-61 DPT Injection ABC+Ole'+Fe 860 18 - 46 GP-62 DPT Injection ABC+Ole'+Fe 860 18 - 46 GP-63 DPT Injection ABC+Ole'+Fe 860 40 - 64 GP-64 DPT Injection ABC+Ole'+Fe 860 40 - 64 GP-65 DPT Injection ABC+Ole'+Fe 860 40 - 64 GP-66 DPT Injection ABC+Ole'+Fe 860 40 - 64 GP-67 DPT Injection ABC+Ole'+Fe 860 40 - 64 GP-68 DPT Injection ABC+Ole'+Fe 860 40 - 64 GP-69 DPT Injection ABC+Ole'+Fe 860 40 - 64 GP-70 DPT Injection ABC+Ole'+Fe 860 40 - 64 GP-71 DPT Injection ABC+Ole'+Fe 860 40 - 64 GP-72 DPT Injection ABC+Ole'+Fe 860 40 - 64 GP-73 DPT Injection ABC+Ole'+Fe 860 40 - 64 GP-74 DPT Injection ABC+Ole'+Fe 980 75 - 95 GP-75 DPT Injection ABC+Ole'+Fe 980 75 - 95 GP-76 DPT Injection ABC+Ole'+Fe 980 75 - 95 GP-77 DPT Injection ABC+Ole'+Fe 980 75 - 95 GP-78 DPT Injection ABC+Ole'+Fe 750 114 - 134 GP-79 DPT Injection ABC+Ole'+Fe 750 114 - 134 GP-80 DPT Injection ABC+Ole'+Fe 750 114 - 134 GP-81 DPT Injection ABC+Ole'+Fe 750 114 - 134 GP-82 DPT Injection ABC+Ole'+Fe 750 114 - 134 GP-83 DPT Injection ABC+Ole'+Fe 750 114 - 134 GP-84 DPT Injection ABC+Ole'+Fe 750 114 - 134 GP-85 DPT Injection ABC+Ole'+Fe 750 114 - 134 GP-86 DPT Injection ABC+Ole'+Fe 750 114 - 134 GP-87 DPT Injection ABC+Ole'+Fe 750 114 - 134
Notes:
DPT = direct push technology ERD = enhanced reductive dechlorination ft bgs = feet below ground surface gal = gallon
* Injection depths for injection wells refer to the screened intervals.
Numbering of GP-## locations are continued from the previous (2017) injection program.
11,000 15
Existing Injection Well Network
Proposed 2018 DPT Injection Locations
Area 1 - G6M-13-05X
FDSA
Area 1 -
G6M-07-02X
Area 5 - G6M-97-05B
Area 3 - G6M-04-02X
20,250 15
8,100 20
3,000 20
4,000 20
3,000 20
!@!P
")E
")E
")E
")E
#0 #0
#0
Nashua River
IWS Syste m Enc losure
Build ing
Build ing 3818
Build ing 3822
Build ing 3820
T 3807
T 3823
Fitc hburg Road /Route 2A
Form e r N orth Post
Me rrim ac k Ware hous e , Inc .
Rubb Air Door
G6M-13-03X
MW-3
G6M-02-01X
G6M-03-07X
X SA-12-98X X SA-12-97X
X SA-12-96X
X SA-12-95X
G6M-04-14X
G6M-02-06X
G6M-04-07X
G6M-04-06X
G6M-02-07X
G6M-03-08X
G6M-04-05X G6M-03-09X
G6M-03-10X G6M-02-12X
G6M-02-11X
G6M-97-05B
MW-7
G6M-02-13X G6M-02-04X
G6M-04-04X
G6M-04-02X
G6M-04-03X
G6M-04-01X
IW-6
IW-1
IW-2
IW-3
IW-4
IW-5
IW-33
IW-32
IW-31
IW-30IW-29
IW-34
G6M-05-02X /IW-35
IW-36
G6M-06-01X
G6M-02-05X
G6M-13-01X
G6M-13-04X
IW-39
G6M-13-02X
G6M-02-03X G6M-97-28X
IW-24
IW-25 IW-26
IW-27
IW-28
G6M-07-01X
IW-23
IW-22IW-21
IW-20IW-37
(ND)
(ND)
(ND)
(ND)
(5.0) (8.0)
(26)
(36) (1.0)
(ND)
(38)
(1.8)
(4.2)
(ND)
(ND)
(ND)
(ND) (ND)
(140)
(ND)
(3.3)
(ND)
(ND)
(97)
(ND)
(ND)
(10)
(40)
(65)
(ND)
Area 5 DPT Injection Area
Area 3 DPT Injection Area
Le g e nd !> ERD LTM We ll - Sam ple d Se m i-Annually !> ERD LTM We ll - Sam ple d Annually #0 ERD LTM We ll - Sam ple d Bie nnially !( Monitoring We ll Conve rte d to Inje c tion We ll ")E Mic roWe ll - Sam ple d Annually !( Inje c tion We ll !@ Inje c tion We ll Ins talle d 01/2014 !P Dry We ll !@ Floor Drain
Inte rpre tive Te trac hloroe the ne (PCE) Contour (μg /L)
280 Te trac hloroe the ne (PCE) Conc e ntration (μg /L) DPT Inje c tion Are a ERD Inje c tion We ll Trans e c t Form e r Fort De ve ns Bound ary
Figure 1 Injections Locations and Tetrachloroethene
Concentration in Groundwater, October 2017, AOC 50
2018 ERD Inje c tion Plan
AOC 50
Form e r Fort De ve ns Arm y Installation De ve ns , Mas s ac hus e tts
293 Boston Pos t Road We s t, Suite 100, Marlboroug h, MA 01752
Fig ure
Date :
05/24/2018
0 300150
Fe e tµ
!P
#0
#0
#0
Form e r N orth Pos t
Fire Pond
T 3803
T 3840
T 3840
IW-13D
G6M-04-09X G6M-04-10A
G6M-02-08X
G6M-96-22B
G6M-04-22X G6M-04-31X
G6M-04-11X
G6M-04-15X
G6M-04-13X G6M-07-02X
G6M-94-18X /IW-38
IW-11
IW-8
IW-7
IW-17D
IW-17S
IW-18D
IW-19D
IW-19S
IW-18S
IW-12
IW-16D
IW-16S
IW-15S
IW-15D
IW-13S IW-14S
IW-14S
G6M-03-01X
G6M-03-02X
G6M-04-10X
G6M-95-19X
G6M-96-22A
G6M-13-05X
G6M-13-06X G6M-93-13X
G6M-95-20X G6M-04-12X
G6M-96-13B (910)
(ND)
(ND)
(1.2)(ND)
(ND)
(ND)
(ND)
(1.3)
(1.9)
(280)
(ND)
(ND)
Area 1 DPT Injection Area
Area 1 DPT Injection Area
0 10050
Fe e t
Ae rial Sourc e s : Es ri, Dig italGlobe , Ge oEye , i-cube d, USDA FSA, USGS, AEX , Ge tm apping , Ae rog rid , IGN , IGP, swis s topo, and the GIS Us e r Com m unity
Area 1 Inset
See Area 1 Inset
N ote s:
1.Fe ature locations provid e d by HGL
2. μg /L = Mic rog ram s pe r lite r
3. ERD = Enhanc e d Re duc tive De c hlorination
4. GW = Groundwate r
5. J = Estim ate
6. LTM = Long -Te rm Monitoring
7. N D = N on-d e te c t KOMAN Government Solutions, LLC
File : ERD2018_AOC50_IN J_LOC_PCE_102017.m xd
| Injection Summary |
| Table 1 - ERD Injection Program |
| Figure 1 - Injection Locations |
File details come from the government source that posted it.