W912QR25R0027_Plans-0003.pdf
PDF 9 MB Posted
- Solicitation number
- W912QR25R0027
About this file
This is a set of architectural drawings for the renovation of a research facility at Wright-Patterson Air Force Base, Ohio. The drawings are part of solicitation W912QR25R0027 for project MS&A-F20145, titled "Renovate Research Facility for MS&A," with project number ZHTV 210805. The drawings were prepared by CEMS Architecture and Engineering and issued on June 16, 2025, with amendments through August 5, 2025, under the Louisville District US Army Corps of Engineers.
The drawings include detailed architectural plans for basement through third floor levels, showing fire rating requirements, spray-applied fireproofing details, wall sections, stair plans and sections, secured area wall and ceiling details, and seismic details. Key specifications include 2-hour fire-rated floor/ceiling assemblies, spray-applied fire proofing on structural steel elements, seismic joint installations capable of 2-inch movement in all directions, and specialized security features including perimeter shaft walls and secured area construction. The project involves extensive interior renovations with new partitions, door installations, finish materials including carpet tiles and vinyl flooring, and electrical/grounding systems. The drawings also specify hollow metal doors and frames throughout, with various fire ratings and sound transmission class (STC) requirements ranging from 45 to 50 for different areas.
View the file
Other files
Show all 13
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
H1 A-301
A10
A-301
IJJ.2LM GHK J.4 H.5 G.5J.9L.2L.9
12.1
13.2
13.314.4
14.9
EXPOSED
EXPOSED
EXPOSED
EXPOSED
EXPOSED
12'-0" AFF
EXPOSED EXPOSEDEXPOSED
EXPOSED
B073A
B073B
B073C B073D
H051
B089B088
B087
B050
B090
B070
B086
17'-0" AFF
12'-0" AFF
2HR RATED CEILING
ASSEMBLY; UL G504
GRAPHIC SCALE
164 8268
SCALE: 1/8"=1'-0"
GENERAL NOTES
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
L O
U
IS
V
IL
L E
D
IS
T R
IC
T
D
R M
A R
T
IN
L U
T H
E R
K
IN
G P
L L O
U
IS
V
IL
L E
K
Y w w w .c e m s -a e .c o m
P
M
D a v e
Y e n s a n
P ro je c t:
C
.8
.3
PLAN NORTH
C E
M S
A-109
B A
S E
M E
N T
R E
F L E
C T
E D
C E
IL
IN
G P
L A
N
W R
IG
H
T -P
A T
T E
R S
O N
A
IR
F O
R C
E B
A S
E O
H
IO
D V
O N
T E
R S
C H
B M
C C
O Y
M S
M
IT
H
J
U N
- - 4
P
N
U M
B E
R
D R
A W
IN
G
C O
D E
C E
R T
IF
IE
D F
IN
A
L S
U B
M
IT
T A
L
R E
N O
V A
T E
R E
S E
A R
C H
F A
C
IL
IT
Y
F O
R M
S
A -F
P R
O J E
C T
N U
M B
E R
Z
H T
V
SCALE: 1/8" = 1'-0"B1
BASEMENT REFLECTED CEILING PLAN
AREA OF WORK
KEYPLAN
1. SEE OTHER DISCIPLINES DRAWINGS FOR
PENETRATION DETAILS THROUGH SOUND
RATED AND SECURE PERIMETER WALLS,
FLOORS, AND LID.
A
M E
N D
M E
N T
A U
G
DEAN C.
VON TERSCH
A-7903
CHARLESTON
SC
W
IS
CONSIN
A R
C H I T E C
T
-A
UG-2
W
2Q R
R
_P la ns -0
IJJ.2LM GHK J.4 H.5 G.5J.9L.2L.9
12.1
13.2
13.314.4
14.9
A6
A15
A15
A16 A16
A7
A7
IJJ.2LM GHK J.4 H.5 G.5J.9L.2L.9
12.1
13.2
13.314.4
14.9
A15 A15
A17A17
A7
A7
IJJ.2LM GHK J.4 H.5 G.5J.9L.2L.9
12.1
13.2
13.314.4
14.9
A15
A18
A15
A18
A7
A7
1. SEE ADDITIONAL FIRE RATED WALL AND
FLOOR/CEILING REQUIREMENTS ON
OTHER SHEETS.
2. RATED PENETRATIONS ARE TO BE
PROVIDED THROUGH ALL RATED WALL
AND FLOOR/CEILING ASSEMBLIES.
3. SEE OTHER DISCIPLINES DRAWINGS FOR
PENETRATION DETAILS THROUGH SOUND
RATED AND SECURE PERIMETER WALLS,
FLOORS, AND LID.
IJJ.2LM GHK J.4 H.5 G.5J.9L.2L.9
12.1
13.2
13.3
14.4
14.9
A29
GRAPHIC SCALE
164 8268
SCALE: 1/8"=1'-0"
GENERAL NOTES
SHEET KEYNOTES
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
L O
U
IS
V
IL
L E
D
IS
T R
IC
T
D
R M
A R
T
IN
L U
T H
E R
K
IN
G P
L L O
U
IS
V
IL
L E
K
Y w w w .c e m s -a e .c o m
P
M
D a v e
Y e n s a n
P ro je c t:
C
.8
.3
PLAN NORTH
C E
M S
A-113
S P
R A
Y O
N F
IR
E
P R
O O
F
IN
G P
L A
N S
W R
IG
H
T -P
A T
T E
R S
O N
A
IR
F O
R C
E B
A S
E O
H
IO
D V
O N
T E
R S
C H
B M
C C
O Y
M S
M
IT
H
J
U N
- - 4
P N
U M
B E
R
D R
A W
IN
G
C O
D E
C E
R T
IF
IE
D F
IN
A
L S
U B
M
IT
T A
L
R E
N O
V A
T E
R E
S E
A R
C H
F A
C
IL
IT
Y
F O
R M
S
A -F
P R
O J E
C T
N U
M B
E R
Z
H T
V
SCALE: 1/8" = 1'-0"A1
FIRST FLOOR FIRE RATING FLOOR PLAN
SCALE: 1/8" = 1'-0"J1
SECOND FLOOR FIRE RATING FLOOR PLAN
SCALE: 1/8" = 1'-0"J10
THIRD FLOOR FIRE RATING FLOOR PLAN
AREA OF WORK
KEYPLAN
A6 FIRST FLOOR 2-HR FLOOR/CEILING
ASSEMBLY AT CROSSHATCHED AREA.
FLOOR BEAMS AND FLOOR JOISTS IN THIS
AREA TO RECEIVE SPRAY-APPLIED FIRE
PROOFING TO ACHIEVE 2-HR FIRE RATING.
PENETRATIONS THROUGH FLOOR IN THIS
CROSSHATCHED AREA ARE TO BE 2-HR
RATED.
A7 1-HR FLOOR/CEILING ASSEMBLY AT
CROSSHATCHED AREA. PENETRATIONS
THROUGH FLOOR IN THIS
CROSSHATCHED AREA ARE TO BE 1-HR
RATED.
A15 STRUCTURAL BEAM TO RECEIVE
SPRAY-APPLIED FIRE PROOFING TO
ACHIEVE 2-HR FIRE RATING FROM 2-HR
FIRE RATED STAIR BACK TO COLUMN AT
GRID LINE 13.2.
A16 STRUCTURAL COLUMN, FROM BASEMENT
FLOOR LEVEL TO FIRST FLOOR LEVEL, TO
RECEIVE SPRAY-APPLIED FIRE PROOFING
TO ACHIEVE 2-HR FIRE RATING.
A17 STRUCTURAL COLUMN, FROM FIRST
FLOOR LEVEL TO SECOND FLOOR LEVEL,
TO RECEIVE SPRAY-APPLIED FIRE
PROOFING TO ACHIEVE 2-HR FIRE RATING.
A18 STRUCTURAL COLUMN, FROM SECOND
FLOOR LEVEL TO THIRD FLOOR LEVEL, TO
RECEIVE SPRAY-APPLIED FIRE PROOFING
TO ACHIEVE 2-HR FIRE RATING.
A29 2-HR SPRAY-APPLIED FIRE PROOFING AT
STEEL BEAMS, STEEL JOISTS, AND
UNDERSIDE OF STEEL LID DECK.
SCALE: 1/8" = 1'-0"A10
STEEL DECK LID FIRE RATING FLOOR PLAN
A
M E
N D
M E
N T
A U
G
DEAN C.
VON TERSCH
A-7903
CHARLESTON
SC
W
IS
CONSIN
A R
C H I T E C
T
-A
UG-2
W
2Q R
R
_P la ns -0
FIRST FLOOR
900'-0"
SECOND FLOOR
913'-0"
THIRD FLOOR
926'-0"
BASEMENT
879'-9"
T.O. LID
939'-2 1/2"
M L.9
RAISED ACCESS
FLOORING
CONC FLOOR ON
METAL DECK
CONC FLOOR ON
METAL DECK
CONC FLOOR ON
METAL DECK
A-501 B16
A-504 K7
A-504 E1
A-504 K1
NEW REINFORCED 12" CMU WALL
INFILL - PAINT EXTERIOR. SEE
STRUCTURAL.
UL L701
UL U415
UL U415
UL U415
UL U415
FIRST FLOOR
900'-0"
SECOND FLOOR
913'-0"
THIRD FLOOR
926'-0"
BASEMENT
879'-9"
T.O. LID
939'-2 1/2"
GH G.5
RAISED ACCESS
FLOORING
ACOUSTIC
CEILING
CONC FLOOR ON
METAL DECK
CONC FLOOR ON
METAL DECK
CONC FLOOR ON
METAL DECK
A-501 A11
A-501 G12
A-501 G2
A-501 L12
/2
UL L701
UL U415
UL U415
UL U436
FIRST FLOOR
900'-0"
T.O. HIGH ROOF
WALL
949'-3"
SECOND FLOOR
913'-0"
THIRD FLOOR
926'-0"
BASEMENT
879'-9"
T.O. LID
939'-2 1/2"
12 12.1
RAISED ACCESS
FLOORING
CONC FLOOR ON
METAL DECK
CONC FLOOR ON
METAL DECK
CONC FLOOR ON
METAL DECK
/2
A-503 A10
A-503 A10
A-505 A8
UL L701
UL U419
UL U419
UL U419
UL U419
A-503 A10
SIM
SIM
FIRST FLOOR
900'-0"
SECOND FLOOR
913'-0"
THIRD FLOOR
926'-0"
BASEMENT
879'-9"
T.O. LID
939'-2 1/2"
1514.9
RAISED ACCESS
FLOORING
/2
CONC FLOOR ON
METAL DECK
CONC FLOOR ON
METAL DECK
CONC FLOOR ON
METAL DECK
A-501 G5
A-501 G5
A-501 K6
A-501 A6
UL L701
UL U415
UL U415
UL U415
UL U415
GRAPHIC SCALE
02 4 8134
SCALE: 1/4"=1'-0"
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
L O
U
IS
V
IL
L E
D
IS
T R
IC
T
D
R M
A R
T
IN
L U
T H
E R
K
IN
G P
L L O
U
IS
V
IL
L E
K
Y w w w .c e m s -a e .c o m
P
M
D a v e
Y e n s a n
P ro je c t:
C
.8
.3
C E
M S
A-302
W A
L L S
E C
T
IO
N S
W R
IG
H
T -P
A T
T E
R S
O N
A
IR
F O
R C
E B
A S
E O
H
IO
D V
O N
T E
R S
C H
B M
C C
O Y
M S
M
IT
H
J
U N
- - 4
P N
U M
B E
R
D R
A W
IN
G
C O
D E
C E
R T
IF
IE
D F
IN
A
L S
U B
M
IT
T A
L
R E
N O
V A
T E
R E
S E
A R
C H
F A
C
IL
IT
Y
F O
R M
S
A -F
P R
O J E
C T
N U
M B
E R
Z
H T
V
SCALE: 1/4" = 1'-0"
H1
A-301 A1
WALL SECTION
SCALE: 1/4" = 1'-0"
H1
A-301 A5
WALL SECTION
SCALE: 1/4" = 1'-0"
A10
A-301 A10
WALL SECTION
SCALE: 1/4" = 1'-0"
A10
A-301 A14
WALL SECTION
A
M E
N D
M E
N T
J U
L
A
M E
N D
M E
N T
A U
G
2 2
DEAN C.
VON TERSCH
A-7903
CHARLESTON
SC
W
IS
CONSIN
A R
C H I T E C
T
-A
UG-2
W
2Q R
R
_P la ns -0
UP
UP
DN
UP
DN
DN
L.2L.9
14.9
C8 A-401
S6C.2
S C
.2
S3A
H6G.2
H4G.2
S2L.2
B
B
C15
A-401
B088A
A-502 K6
R @ 6 3/4"12
11"
6'-5 3/8"
/2
/8
/8
T O
S T
D F
A C
E
/2
/2
10 1/4"
S T
D T
O S
T D
/2
STEEL
RAILING
FIRST FLOOR
900'-0"
SECOND FLOOR
913'-0"
THIRD FLOOR
926'-0"
BASEMENT
879'-9"
T.O. LID
939'-2 1/2"
M L.2L.9
B
B
C15 A-401
/2
R
/2
R
/2
R
/2
R
/2
R
/4
R
/4
R
/4
A-501 A1
A-501 G2
A-501 G2
A-501 L1
A-501 L1
A-501 L1
A-501 L16
11" 5'-2" 3 1/4" CLEAR
11 T @ 11" = 10'-1"
11"
5'-6 3/8"
11 T @ 11" = 11"10'-1"11"
11"11 T @ 11" = 10'-1"11"5'-6 3/8"
11"10'-1"11"
A29
A-505 G14
A-505 D14
L.2L.9
14.9
C8
A-401
C15
A-401
H G
.2
H6G.2
S C
.2
R @ 6 1/2"12
R @ 6 1/2"12
L.2L.9
14.9
C8
A-401
C15
A-401
R @ 6 1/2"12
R @ 6 1/2"12
S6P.2a
H G
.2
H6G.2
S C
.2
S6C.2
S3A
L.2L.9
14.9
C8 A-401
C15
A-401
R @ 6 1/2"12
S6P.2a S6C.2
S C
.2
H6G.2
H G
.2
FIRST FLOOR
900'-0"
SECOND FLOOR
913'-0"
THIRD FLOOR
926'-0"
BASEMENT
879'-9"
T.O. LID
939'-2 1/2"
14.9
C8
A-401
3 7/8"
3'-6" 11" 3'-6"
3 5/8"
3 7/8"
3'-6"
WALL MOUNTED HANDRAIL, TYP
STRINGER MOUNTED
GUARDRAIL AND HANDRAIL, TYP
CONCRETE PAN TREAD SYSTEM, TYP
STEEL STRINGERS, TYP
GUARDRAIL
CONCRETE LANDING ON
METAL DECK, TYP
/2
A29
STEEL RAILING2
M A
X
GRAPHIC SCALE
02 4 8134
SCALE: 1/4"=1'-0"
SHEET KEYNOTES
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
L O
U
IS
V
IL
L E
D
IS
T R
IC
T
D
R M
A R
T
IN
L U
T H
E R
K
IN
G P
L L O
U
IS
V
IL
L E
K
Y w w w .c e m s -a e .c o m
P
M
D a v e
Y e n s a n
P ro je c t:
C
.8
.3
PLAN NORTH
C E
M S
A-401
E N
L A
R G
E D
W E
S T
S T
A
IR
P L A
N S
A N
D S
E C
T
IO
N S
W R
IG
H
T -P
A T
T E
R S
O N
A
IR
F O
R C
E B
A S
E O
H
IO
D V
O N
T E
R S
C H
B M
C C
O Y
M S
M
IT
H
J
U N
- - 4
P N
U M
B E
R
D R
A W
IN
G
C O
D E
C E
R T
IF
IE
D F
IN
A
L S
U B
M
IT
T A
L
R E
N O
V A
T E
R E
S E
A R
C H
F A
C
IL
IT
Y
F O
R M
S
A -F
P R
O J E
C T
N U
M B
E R
Z
H T
V
SCALE: 1/4" = 1'-0"
B1
A-101 B2
ENLARGED WEST BASEMENT STAIR PLAN
SCALE: 1/4" = 1'-0"
B2
A-401 C8
WEST STAIR SECTION
SCALE: 1/4" = 1'-0"
B1
A-102 E2
ENLARGED WEST FIRST FLOOR STAIR PLAN
SCALE: 1/4" = 1'-0"
C1
A-103 H2
ENLARGED WEST SECOND FLOOR STAIR PLAN
SCALE: 1/4" = 1'-0"
C1
A-104 M2
ENLARGED WEST THIRD FLOOR STAIR PLAN
SCALE: 1/4" = 1'-0"
B2
A-401 C15
WEST STAIR SECTION
A29 2-HR SPRAY-APPLIED FIRE
PROOFING AT STEEL BEAMS,
STEEL JOISTS, AND UNDERSIDE
OF STEEL LID DECK.
A
M E
N D
M E
N T
A U
G
DEAN C.
VON TERSCH
A-7903
CHARLESTON
SC
W
IS
CONSIN
A R
C H I T E C
T
-A
UG-2
W
2Q R
R
_P la ns -0
SECOND FLOOR
913'-0"
L.9
FINISH FLOOR AND BASE AS
SCHEDULED
(2) LAYERS 5/8" GYP BD, TYPE X
1" SHAFTWALL LINER PANEL
4" SHAFTWALL STUD @ 24" OC
4" SHAFTWALL HORIZ
STUD @ END WALL
SEALANT
DEFLECTION TRACK
3-5/8" MTL STUD @ 16" OC. 6" MTL
STUD @ 16" OC WHERE
INDICATED.
4" SHAFTWALL STUD @ 24" OC
4" SHAFTWALL HORIZ
STUD @ END WALL
(2) LAYERS 5/8" GYP BD, TYPE X
STEEL COLUMN,
SEE STRUCTURAL.
THIRD FLOOR
926'-0"
L.9
(2) LAYERS 5/8" GYP BD, TYPE X
1" SHAFTWALL LINER PANEL
FINISH FLOOR AND BASE AS
SCHEDULED
(2) LAYERS 5/8" GYP BD, TYPE X
1" SHAFTWALL LINER PANEL
4" SHAFTWALL STUD @ 24" OC
4" SHAFTWALL HORIZ
STUD @ END WALL
DEFLECTION TRACK
3-5/8" MTL STUD @ 16" OC. 6" MTL
STUD @ 16" OC WHERE
INDICATED.
STEEL BEAM; SEE
STRUCTURAL
T.O. LID
939'-2 1/2"
L.9
(2) LAYERS 5/8" GYP BD, TYPE X
4" SHAFTWALL J TRACK @ WALL
END
4" SHAFTWALL STUD @ 24" OC
1" SHAFTWALL LINER PANEL,
TYPE X
METAL DECK.
SEE STRUCTURAL
4" SHAFTWALL HORIZ
STUD @ END WALL
DEFLECTION TRACK
3-5/8" MTL STUD @ 16" OC. 6" MTL
STUD @ 16" OC WHERE
INDICATED.
3/4" WOOD FIBER BOARD PER UL L701 2-HR ASSEMBLY,
SECURE TO STEEL LID DECK
STEEL BEAM. SEE
STRUCTURAL.
14 GAUGE BENT SECURE TO
BEAM TO SUPPORT DECK
EDGE AND LINER PANEL
SEALANT
SEALANT
SEE THIRD FLOOR 2HR FIRE
RATED AND SECURE AREA
CEILING DETAIL.
5/8" TYPE X CEMENT BOARD
CONT SANTOPRENE SEAL
CONT ALUMINUM SUPPORT PLATE
CONT ALUMINUM
SURFACE MOUNT FRAME
FLOOR FINISH SEE PLANS
SELF TAPPING METAL SCREW
RAISED ACCESS FLOORING
EXISTING CONC WALL
4"3"
ACOUSTICAL
CEILING PANEL
AND TEE
CONT ALUM
RECESSED FRAME
SELF TAPPING METAL SCREW
POP RIVET
CONT ALUM FRAME
CONT SANTOPRENE SEAL
WALL, SEE PLANS
4"
FLOOR FINISH
SEE PLAN
CONT ALUMINUM
SURFACE MOUNT FRAME
CONT. ALUMINUM
SUPPORT PLATE
CONT. ALUMINUM WALL FRAME
CONT SANTOPRENE SEAL
SELF TAPPING METAL SCREW WALL. SEE PLANS
RAISED ACCESS FLOORING
4" 3"
CONT ALUM VARIABLE
DEGREE PLATE
CONT VINYL GASKET
2"
CONT ALUM VARIABLE
DEGREE RETAINER
CONCRETE WALL
SELF TAPPING METAL SCREW
5 1/4"
/8
/8
PROVIDE TAMPER PROOF SCREWS IN SLOTTED
HOLES IN COVER SPACED NOT GREATER THAN
48" O.C. TO SECURE COVER TO WALL.
CONT ALUM VARIABLE
DEGREE PLATE
CONT VINYL GASKET
CONT ALUM VARIABLE
DEGREE RETAINER
WALL, SEE PLANS
SELF TAPPING METAL SCREW
FIRE RATED PREMANUFACTURED
SEISMIC JOINT CAPABLE OF NOT
LESS THAN 2" OF MOVEMENT IN
ALL DIRECTIONS
SELF TAPPING CONCRETE SCREW
CONT ALUM VARIABLE DEGREE RETAINER
CONT ALUM VARIABLE DEGREE PLATE
CONT. VINYL GASKET
FIRE RATED PREMANUFACTURED
SEISMIC JOINT CAPABLE OF NOT
LESS THAN 2" OF MOVEMENT IN
ALL DIRECTIONS
PROVIDE TAMPER PROOF SCREWS IN
SLOTTED HOLES IN COVER SPACED NOT
GREATER THAN 48" O.C. TO SECURE
COVER TO WALL.
EXISTING WALL TO REMAIN
4" SHAFTWALL STUD @ 24" OC
2 1/2" STUD FRAMING, BRACE TO
STRUCTURE AS REQUIRED
2 1/2" STUD FRAMING, BRACE TO
STRUCTURE AS REQUIRED
1" SHAFTWALL LINER PANEL
4" SHAFTWALL STUD @ 24" OC
STEEL COLUMN,
SEE STRUCTURAL
2 1/2" STUD FRAMING, BRACE TO
STRUCTURE AS REQUIRED
2 1/2" STUD FRAMING, BRACE TO
STRUCTURE AS REQUIRED
(2) LAYERS 5/8" GYP BD, TYPE X
(2) LAYERS 5/8" GYP BD, TYPE X
(2) LAYERS 5/8" GYP BD, TYPE X
AT THIRD FLOOR LADDER
LOCATION PROVIDE
ADDITIONAL METAL STUDS
FOR LADDER ANCHORAGE
5/8" GYP BD
COLD FORMED ANGLE
SECURED TO COLUMN FOR
GYP BD ATTACHMENT
STEEL COLUMN,
SEE STRUCTURAL
SOUND BATT INSULATION
HOLLOW METAL FRAME;
SEE JAMB DETAIL
3-5/8" MTL STUD @ 16" OC. 6" MTL
STUD @ 16" OC WHERE
INDICATED.
5/8" GYP BD
STUD FRAMING AT
DOOR JAMB. SEE JAMB
DETAIL.
6"6"
SCALE: 3"=1'-0"
04 2
GRAPHIC SCALES
3"3"
SCALE: 6"=1'-0"
02 1
SCALE: 1 1/2"=1'-0"
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
L O
U
IS
V
IL
L E
D
IS
T R
IC
T
D
R M
A R
T
IN
L U
T H
E R
K
IN
G P
L L O
U
IS
V
IL
L E
K
Y w w w .c e m s -a e .c o m
P
M
D a v e
Y e n s a n
P ro je c t:
C
.8
.3
C E
M S
A-504
S E
C U
R E
D A
R E
A W
A L L A
N D
C E
IL
IN
G D
E T
A
IL
S A
N D
S E
IS
M
IC
D
E T
A
IL
S
W R
IG
H
T -P
A T
T E
R S
O N
A
IR
F O
R C
E B
A S
E O
H
IO
D V
O N
T E
R S
C H
B M
C C
O Y
M S
M
IT
H
J
U N
- - 4
P N
U M
B E
R
D R
A W
IN
G
C O
D E
C E
R T
IF
IE
D F
IN
A
L S
U B
M
IT
T A
L
R E
N O
V A
T E
R E
S E
A R
C H
F A
C
IL
IT
Y
F O
R M
S
A -F
P R
O J E
C T
N U
M B
E R
Z
H T
V
SCALE: 1 1/2" = 1'-0"
A1
A-302 K7
T.O.W / B.O. SECURED WALL DETAIL
SCALE: 1 1/2" = 1'-0"
A1
A-302 E1
SECURED T.O. WALL / LID DETAIL
SCALE: 1 1/2" = 1'-0"
A1
A-302 K1
SECURED T.O. WALL / LID DETAIL
SCALE: 6" = 1'-0"
B1
A-102 F12
SEISMIC FLOOR TO FLOOR DETAIL
SCALE: 6" = 1'-0"
B1
A-110 E6
SEISMIC WALL TO CEILING DETAIL
SCALE: 6" = 1'-0"
B1
A-102 L12
SEISMIC WALL TO FLOOR DETAIL
SCALE: 6" = 1'-0"A1
SEISMIC WALL CORNER
TO WALL CEILING DETAIL
SCALE: 6" = 1'-0"
B1
A-102 A8
SEISMIC WALL "T"
INTERSECTION DETAIL
SCALE: 3" = 1'-0"
B1
A-101 A12
SEISMIC 2-HR WALL BASEMENT DETAIL
SCALE: 1 1/2" = 1'-0"
C1
A-103 L17
PERIMETER SHAFT WALL
COLUMN WRAP DETAIL
SCALE: 1 1/2" = 1'-0"
B1
A-102 G17
COLUMN WRAP DETAIL
A
M E
N D
M E
N T
A U
G
DEAN C.
VON TERSCH
A-7903
CHARLESTON
SC
W
IS
CONSIN
A R
C H I T E C
T
-A
UG-2
5 W
2Q R
R
_P la ns -0
14.4
(2) LAYERS 5/8" GYP BD, TYPE X
2 1/2" STUD FRAMING, BRACE TO
STRUCTURE AS REQUIRED
4" SHAFTWALL STUD @ 24" OC
1" SHAFTWALL LINER PANEL
4" SHAFTWALL STUD @ 24" OC
(2) LAYERS 5/8" GYP BD, TYPE X
STRUCTURAL STEEL
COLUMN. SEE STRUCTURAL
5/8" GYP BD, TYPE X
3-5/8" MTL STUD @ 16" OC. 6" MTL
STUD @ 16" OC WHERE
INDICATED.
(2) LAYERS 5/8" GYP BD, TYPE X
SURFACE MOUNTED SEISMIC COVER
FIRE RATED PREMANUFACTURED
SEISMIC JOINT CAPABLE OF NOT
LESS THAN 2" OF MOVEMENT IN ALL
DIRECTIONS
PROVIDE TAMPER PROOF SCREWS IN
SLOTTED HOLES IN COVER SPACED
NOT GREATER THAN 48" O.C. TO
SECURE COVER TO WALL.
SURFACE MOUNTED SEISMIC COVER
3-5/8" MTL STUD @ 16" OC. 6" MTL
STUD @ 16" OC WHERE
INDICATED.
2 1/2" STUD FRAMING, BRACE TO
STRUCTURE AS REQUIRED
5/8" GYP BD, TYPE X
2 1/2" STUD FRAMING, BRACE TO
STRUCTURE AS REQUIRED
3-5/8" MTL STUD @ 16" OC. 6" MTL
STUD @ 16" OC WHERE
INDICATED.
5/8" GYP BD, TYPE X5/8" GYP BD
EXISTING LAMARS CONTROL ROOM
WALL TO BE EXTENDED TO NEW 1-
HOUR SMOKE RATED WALL
STRUCTURAL
STEEL COLUMN.
SEE STRUCTURAL
STRUCTURAL STEEL
COLUMN. SEE STRUCTURAL
HM FRAME
8" MTL. STUD @ 16" OC
(2) LAYERS 5/8" GYP BD, TYPE X
G.5
5/8" GYP BD
5/8" GYP BD
2 1/2" STUD FRAMING, BRACE TO
STRUCTURE AS REQUIRED
(2) LAYERS 5/8" GYP BD, TYPE X
3-5/8" MTL STUD @ 16" OC. 6" MTL
STUD @ 16" OC WHERE
INDICATED.
SURFACE MOUNTED SEISMIC COVER
PROVIDE TAMPER PROOF SCREWS
IN SLOTTED HOLES IN COVER
SPACED NOT GREATER THAN 48"
O.C. TO SECURE COVER TO WALL.
PROVIDE TAMPER PROOF SCREWS
IN SLOTTED HOLES IN COVER
SPACED NOT GREATER THAN 48"
O.C. TO SECURE COVER TO WALL.
SURFACE MOUNTED
SEISMIC COVER
SELF TAPPING
METAL SCREW
2 1/2" STUD FRAMING, BRACE TO
STRUCTURE AS REQUIRED
STEEL COLUMN,
SEE STRUCTURAL
(2) LAYERS 5/8" GYP BD, TYPE X
3-5/8" MTL STUD @ 16" OC. 6" MTL
STUD @ 16" OC WHERE
INDICATED.
(2) LAYERS 5/8" GYP BD, TYPE X
3-5/8" MTL STUD @ 16" OC. 6" MTL
STUD @ 16" OC WHERE
INDICATED.
(2) LAYERS 5/8" GYP BD
G
12.1
SELF TAPPING CONCRETE SCREW
CONT ALUM VARIABLE DEGREE RETAINER
CONT ALUM VARIABLE DEGREE PLATE
CONT. VINYL GASKET
FIRE RATED
PREMANUFACTURED
SEISMIC JOINT CAPABLE OF
NOT LESS THAN 6" OF
MOVEMENT IN ALL
DIRECTIONS
CONTRACTOR TO REMOVE SUFFICIENT AMOUNT OF
EXISTING WALL INSULATION BOARD TO INSTALL SEISMIC
JOINT. CONTRACTOR TO REINSTALL EXISTING PANELS UP
TO WITHIN 2": OF NEW SEISMIC JOINT LOCATIONS. TYPICAL
AT SECOND AND THIRD FLOORS.
PROVIDE TAMPER ROOF SCREWS IN SLOTTED
HOLES IN COVER SPACED NOT GREATER THAN
48" O.C. TO SECURE COVER TO WALL.
1" SHAFTWALL LINER PANEL,
TYPE X
4" SHAFTWALL STUD @ 24" OC(2) LAYERS 5/8" GYP BD, TYPE X
3-5/8" MTL STUD @ 16" OC. 6" MTL
STUD @ 16" OC WHERE
INDICATED.
3-5/8" MTL STUD @ 16" OC. 6" MTL
STUD @ 16" OC WHERE
INDICATED.
(2) LAYERS 5/8" GYP BD, TYPE X
(2) LAYERS 5/8" GYP BD, TYPE X
EXISTING WALL TO REMAIN
J.4
13.2
2 1/2" STUD FRAMING, BRACE TO
STRUCTURE AS REQUIRED
5/8" GYP BD
5/8" GYP BD
2 1/2" STUD FRAMING, BRACE TO
STRUCTURE AS REQUIRED
3-5/8" MTL STUD @ 16" OC. 6" MTL
STUD @ 16" OC WHERE
INDICATED.
STEEL COLUMN;
SEE STRUCTURAL
5/8" GYP BD
2-HR SPRAY APPLIED FIRE
PROOFING
M L.9
12.1
EXISTING END WALL TRUSS
FRAMING TO REMAIN
INSIDE FACE OF EXISTING
EXTERIOR PRECAST
CONCRETE WALL
(2) LAYERS 5/8" TYPE X GYP BD
OVER NEW STUD FRAMING FROM
TOP OF LID TO UNDERSIDE OF
EXISTING ROOF DECK.
NEW STUD FRAMING SECURED
TO EXISTING PRECAST
CONCRETE WALL AND END WALL
TRUSS FRAMING FROM TOP OF
LID TO UNDERSIDE OF EXISTING
ROOF DECK.
PROVIDE FIRE RATED SEALANT
AT GYP BD TO PRECAST WALL
JUNCTURE AND AT ALL TRUSS
FRAMING PENETRATIONS
THROUGH GYP BD WALL.
EDGE OF LID BELOW
3-5/8" MTL STUD @ 16" OC. 6" MTL
STUD @ 16" OC WHERE
INDICATED.
2 1/2" STUD FRAMING, BRACE TO
STRUCTURE AS REQUIRED
SURFACE MOUNTED SEISMIC COVER
FIRE RATED PREMANUFACTURED SEISMIC
JOINT CAPABLE OF NOT LESS THAN 6" OF
MOVEMENT IN ALL DIRECTIONS. ADJUST
PREMANUFACTURED JOINT MATERIAL AROUND
HORIZONTAL X-BRACING.
PROVIDE TAMPER PROOF SCREWS IN
SLOTTED HOLES IN COVER SPACED NOT
GREATER THAN 48" O.C. TO SECURE
COVER TO WALL.
METAL STUD GUARDRAIL WITH
BRACING; SEE STRUCTURAL
ADJUST COVER AND COMPONENTS AROUND
X-BRACING ACCORDINGLY
CONTRACTOR TO REMOVE SUFFICIENT AMOUNT
OF EXISTING WALL INSULATION BOARD TO
INSTALL SEISMIC JOINT. CONTRACTOR TO
REINSTALL EXISTING PANELS UP TO WITHIN 2":
OF NEW SEISMIC JOINT LOCATIONS. TYPICAL AT
SECOND AND THIRD FLOORS.
(2) LAYERS 5/8" GYP BD,
TYPE X
G
(2) LAYERS 5/8" GYP BD, TYPE X
3-5/8" MTL STUD @ 16" OC. 6" MTL
STUD @ 16" OC WHERE
INDICATED.
2 1/2" STUD FRAMING, BRACE TO
STRUCTURE AS REQUIRED
SEE FLOOR PLAN
FOR ADDITIONAL
WALL CONDITION
STEEL COLUMN,
SEE STRUCTURAL
(2) LAYERS 5/8" GYP BD, TYPE X
5/8" GYP BD
3-5/8" MTL STUD @ 16" OC. 6" MTL
STUD @ 16" OC WHERE
INDICATED.
2-HR SPRAY
APPLIED FIRE
PROOFING
GRAPHIC SCALE
SCALE: 1 1/2"=1'-0"
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
L O
U
IS
V
IL
L E
D
IS
T R
IC
T
D
R M
A R
T
IN
L U
T H
E R
K
IN
G P
L L O
U
IS
V
IL
L E
K
Y w w w .c e m s -a e .c o m
P
M
D a v e
Y e n s a n
P ro je c t:
C
.8
.3
C E
M S
A-507
D E
T A
IL
S
W R
IG
H
T -P
A T
T E
R S
O N
A
IR
F O
R C
E B
A S
E O
H
IO
D V
O N
T E
R S
C H
J E
C H
C H
A R
Q Y
M S
M
IT
H
J
U N
- - 4
P N
U M
B E
R
D R
A W
IN
G
C O
D E
C E
R T
IF
IE
D F
IN
A
L S
U B
M
IT
T A
L
R E
N O
V A
T E
R E
S E
A R
C H
F A
C
IL
IT
Y
F O
R M
S
A -F
P R
O J E
C T
N U
M B
E R
Z
H T
V
SCALE: 1 1/2" = 1'-0"
B1
A-101 L1
TYPICAL SHAFT WALL COLUMN WRAP DETAIL
SCALE: 1 1/2" = 1'-0"
B1
A-102 A1
TYPICAL SECURED PERIMETER WALL INSIDE CORNER DETAIL
SCALE: 1 1/2" = 1'-0"
B1
A-102 F14
PERIMETER COLUMN WRAP SEISMIC COVER DETAIL
SCALE: 1 1/2" = 1'-0"
B1
A-102 L7
INTERIOR SECURED WALL "T" CONNECTION
SCALE: 3" = 1'-0"
C1
A-103 A9
SEISMIC 2-HR WALL SECOND/THIRD DETAIL
SCALE: 1 1/2" = 1'-0"
C1
A-103 M14
INTERIOR COLUMN WRAP DETAIL
SCALE: 1 1/2" = 1'-0"
C10
A-104 F1
SHAFT SECURED WALL CORNER LID DETAIL
SCALE: 1 1/2" = 1'-0"
B1
A-102 G9
COLUMN WRAP AT WALL DETAIL
SCALE: 1 1/2" = 1'-0"
B1
A-101 D17
EXPOSED COLUMN DETAIL
A
M E
N D
M E
N T
A U
G
DEAN C.
VON TERSCH
A-7903
CHARLESTON
SC
W
IS
CONSIN
A R
C H I T E C
T
-A
UG-2
W
2Q R
R
_P la ns -0
BASEMENT
879'-9"
A-511 L2
A-511 C2
REMOVAL
TRACK COVER
SLIDING DOOR
WALL BEYONDFLOOR MOUNTED
DOOR T-GUIDE
RECESSED DOOR
HANDLE
DOOR TRAVEL STOPS
PROVIDE METAL STUD
FRAMING AS REQUIREDREMOVABLE
TRACK COVER
TRACK
ROLLER
HM SLIDING DOOR
5/8" GYP BD
3-5/8" MTL STUD @ 16" OC. 6" MTL
STUD @ 16" OC WHERE
INDICATED.
HOLLOW MTL FRAME
BASEMENT
879'-9"
FLOOR MOUNTED
DOOR T-GUIDE
HM SLIDING DOOR
JAMB BEYOND
FLOOR MOUNTED DOOR
T-GUIDE BEYOND
HM SLIDING DOOR
PROVIDE METAL
STUD FRAMING AS
REQUIRED
5/8" GYP BD
HOLLOW MTL FRAME
T.O. LID
939'-2 1/2"
PERIMETER SHEET METAL DECK
CLOSURE - TYPICAL ALL 4 SIDES.
FIELD WELD TOP SUPPORT
BRACKET TO STEEL ROOF
DECK SUPPORT FRAMING
LADDER SAFETY EXTENSION
ANCHORED TO LADDER RUNGS
1 1/4" SCH 40 ALUMINUM PIPE
FALL PROTECTION GUARDRAILS
W/ SELF CLOSING GATE
SPRAY APPLIED FIRE PROOFING
AT ALL STEEL LID FRAMING
BEAMS, JOISTS, AND UNDERSIDE
OF STEEL LID DECK PER UL L701
2-HR ASSEMBLY
EXISTING CONCRETE
WALL. FV THICKNESS
SEALANT
HM FRAME - PAINT
(SEE DOOR SCHEDULE)
GROUT SOLID
EXISTING CONCRETE
WALL. FV THICKNESS
SEALANT
HM FRAME - PAINT
(SEE DOOR SCHEDULE)
GROUT SOLID
TAPERED FLUSH
EXPANSION ANCHOR
ALIGN FLUSH
SOUND ATTENUATION
AS INDICATED
WALL FINISH AS INDICATED
2 LAYERS OF GYP BD,
TYPE X AS INDICATED
METAL STUD FRAMING
AS INDICATED
SEALANT, TYP EACH SIDE
HOLLOW METAL FRAME
AS SCHEDULED
DOOR AS SCHEDULED
SOUND ATTENUATION
AS INDICATED
WALL FINISH AS INDICATED
2 LAYERS OF GYP BD,
TYPE X AS INDICATED
METAL STUD FRAMING
AS INDICATED
SEALANT, TYP EACH SIDE
HOLLOW METAL FRAME
AS SCHEDULED
DOOR AS SCHEDULED
MINIMUM 3 JAMB ANCHORS
SOUND ATTENUATION
AS INDICATED
2 LAYERS OF GYP BD,
TYPE X AS INDICATED
RAISED ACCESS
FLOORING PANEL
RAISED ACCESS
FLOORING PANEL
CONT ALUM FRAME,
SEE SEISMIC DETAILS -
WIDER AT DOOR
OPENING
DOOR AND FRAME AS
SCHEDULED (REFER TO
DOOR SCHEDULE AND DETAILS)
ALUMINUM THRESHOLD 6"6"
SCALE: 3"=1'-0"
04 2
GRAPHIC SCALES
SCALE: 1 1/2"=1'-0"
1 2 42
SCALE: 1/2"=1'-0"
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
L O
U
IS
V
IL
L E
D
IS
T R
IC
T
D
R M
A R
T
IN
L U
T H
E R
K
IN
G P
L L O
U
IS
V
IL
L E
K
Y w w w .c e m s -a e .c o m
P
M
D a v e
Y e n s a n
P ro je c t:
C
.8
.3
C E
M S
A-511
D O
O R
D E
T A
IL
S
W R
IG
H
T -P
A T
T E
R S
O N
A
IR
F O
R C
E B
A S
E O
H
IO
D V
O N
T E
R S
C H
B M
C C
O Y
M S
M
IT
H
J
U N
- - 4
P N
U M
B E
R
D R
A W
IN
G
C O
D E
C E
R T
IF
IE
D F
IN
A
L S
U B
M
IT
T A
L
R E
N O
V A
T E
R E
S E
A R
C H
F A
C
IL
IT
Y
F O
R M
S
A -F
P R
O J E
C T
N U
M B
E R
Z
H T
V
SCALE: 1/2" = 1'-0"
B1
A-101 L7
TYPICAL BARN DOOR
SCALE: 1/2" = 1'-0"
B1
A-101 L10
TYPICAL BARN DOOR ELEVATION
SCALE: 3" = 1'-0"
L7
A-511 L2
BARN DOOR HEAD DETAIL
SCALE: 3" = 1'-0"
L7
A-511 C2
BARN DOOR SILL DETAIL
SCALE: 3" = 1'-0"
B1
A-101 F3
BARN DOOR JAMB DETAIL
SCALE: 3" = 1'-0"
A1
A-506 A7
HATCH DETAIL
SCALE: 1 1/2" = 1'-0"G17
HEAD DETAIL
SCALE: 1 1/2" = 1'-0"D17
JAMB DETAIL
SCALE: 1 1/2" = 1'-0"G14
HEAD DETAIL
SCALE: 1 1/2" = 1'-0"D14
JAMB DETAIL
SCALE: 1 1/2" = 1'-0"A14
SILL DETAIL
A
M E
N D
M E
N T
A U
G
DEAN C.
VON TERSCH
A-7903
CHARLESTON
SC
W
IS
CONSIN
A R
C H I T E C
T
-A
UG-2
W
2Q R
R
_P la ns -0
F
(FLUSH DOOR)
N
(NARROW LIGHT)
2F
(DOUBLE FLUSH DOOR)
2N
(DOUBLE NARROW LIGHT)
A1
OH
(OVERHEAD DOOR)
BY OH DOOR MFR
OPENING WIDTH AS INDICATED
BY OH DOOR MFRNOMINAL DOOR WIDTH BY MFR
O P
E N
IN
G
H E
IG
H
T A
S I N
D
IC
A T
E D
B Y
O H
D O
O R
M F
R
N O
M
IN
A L
D O
O R
H E
IG
H
T B
Y M
F R
2BF
(DOUBLE BI-FOLDING DOOR)
BD
(BARN SLIDING DOOR)
2L
(DOUBLE LOUVER)
6" 24" 6" 6" 24" 6"
/2
CUT OPENING IN
EXISTING PANELS
FOR NEW LOUVERS
A
S E
E S
C H
E D
2" SEE SCHED. 2" 2" SEE SCHED. 2"
S E
E S
C H
E D
B
A14
S E
E S
C H
E D
2" SEE SCHED.
MULLION
2" REMOVABLE
SEE SCHED. 2"
C
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
L O
U
IS
V
IL
L E
D
IS
T R
IC
T
D
R M
A R
T
IN
L U
T H
E R
K
IN
G P
L L O
U
IS
V
IL
L E
K
Y w w w .c e m s -a e .c o m
P
M
D a v e
Y e n s a n
P ro je c t:
C
.8
.3
C E
M S
A-602
D O
O R
S C
H E
D U
L E
A N
D T
Y P
E S
W R
IG
H
T -P
A T
T E
R S
O N
A
IR
F O
R C
E B
A S
E O
H
IO
D V
O N
T E
R S
C H
B M
C C
O Y
M S
M
IT
H
J
U N
- - 4
P N
U M
B E
R
D R
A W
IN
G
C O
D E
C E
R T
IF
IE
D F
IN
A
L S
U B
M
IT
T A
L
R E
N O
V A
T E
R E
S E
A R
C H
F A
C
IL
IT
Y
F O
R M
S
A -F
P R
O J E
C T
N U
M B
E R
Z
H T
V
SCALE: NOT TO SCALE
DOOR TYPES
SCALE: NOT TO SCALE
FRAME TYPES
DOOR SCHEDULE SECOND FLOOR
NO.
ROOM LOCATION DOOR
RATING
(MIN.)
STC
FRAME
HARDWARE NO. COMMENTSFROM TO TYPE
OPENING
THICKNESS
UNDER
CUT MATERIAL FINISH FIRE TYPE MATERIAL FINISH
DETAILS
WIDTH HEIGHT HEAD JAMB SILL
SECOND FLOOR
270A HALLWAY MS&A ROOM F 3'-0" 7'-0" 1 3/4" --- HM TP-1 --- 45 A HM TP-1 M4/A-510 J6/A-510 A7/A-510 HW-7 270A
270B HALLWAY MS&A ROOM F 3'-0" 7'-0" 1 3/4" --- HM TP-1 --- 45 A HM TP-1 M4/A-510 J6/A-510 A7/A-510 HW-7 270B
271 HALLWAY TRITONS F 3'-0" 7'-0" 1 3/4" --- HM TP-1 --- 45 A HM TP-1 M4/A-510 J6/A-510 A7/A-510 HW-7 271
272A TRITONS CONTROL ROOM F 3'-0" 7'-0" 1 3/4" --- HM TP-1 --- 45 A HM TP-1 M4/A-510 J6/A-510 A7/A-510 HW-7A 272A
272B HALLWAY CONTROL ROOM F 3'-0" 7'-0" 1 3/4" --- HM TP-1 --- 45 A HM TP-1 M4/A-510 J6/A-510 A7/A-510 HW-7 272B
274 HALLWAY CER F 3'-0" 7'-0" 1 3/4" --- HM TP-1 --- 45 A HM TP-1 M4/A-510 J6/A-510 A7/A-510 HW-7 274
275 HALLWAY NOC / COMPUTERS F 3'-0" 7'-0" 1 3/4" --- HM TP-1 --- 45 A HM TP-1 M4/A-510 J6/A-510 A7/A-510 HW-7 275
277 HALLWAY STORAGE F 3'-0" 7'-0" 1 3/4" --- HM TP-1 --- --- A HM TP-1 G16/A-510 C16/A-510 A12/A-510 HW-11 277
279 HALLWAY ELEC CLOSET F 3'-0" 7'-0" 1 3/4" --- HM TP-1 --- --- A HM TP-1 G16/A-510 C16/A-510 A12/A-510 HW-16 279
280 HALLWAY RR F 3'-0" 7'-0" 1 3/4" --- HM TP-1 --- --- A HM TP-1 M4/A-510 J6/A-510 A7/A-510 HW-19 280
281 HALLWAY RR F 3'-0" 7'-0" 1 3/4" --- HM TP-1 --- --- A HM TP-1 M4/A-510 J6/A-510 A7/A-510 HW-19 281
282 HALLWAY KITCHENETTE N 3'-0" 7'-0" 1 3/4" --- HM TP-1 --- --- A HM TP-1 G16/A-510 C16/A-510 A12/A-510 HW-20 282
283 HALLWAY EAST STAIR N 3'-0" 7'-0" 1 3/4" --- HM TP-1 90 MIN --- A HM TP-1 M4/A-510 J6/A-510 A12/A-510 HW-2 283
284 HALLWAY WEST STAIR N 3'-0" 7'-0" 1 3/4" --- HM TP-1 90 MIN --- A HM TP-1 M4/A-510 J6/A-510 A12/A-510 HW-2 284
284A HALLWAY STORAGE 2BF 6'-0" 7'-0" 1 1/2" --- HM TP-1 --- --- A HM TP-1 M16/A-510 J16/A-510 A12/A-510 HW-25 284A
285 HALLWAY STORAGE 2BF 6'-0" 7'-0" 1 1/2" --- HM TP-1 --- --- A HM TP-1 M16/A-510 J16/A-510 A12/A-510 HW-25 285
H200 VEST HALLWAY F 3'-0" 7'-0" 1 3/4" --- HM TP-1 --- 50 A HM TP-1 M4/A-510 J6/A-510 A7/A-510 HW-5 H200
H278 HALLWAY HALLWAY F 3'-0" 7'-0" 1 3/4" --- HM TP-1 --- 50 A HM TP-1 M4/A-510 J6/A-510 A7/A-510 HW-6 H278
H283A HALLWAY HALLWAY F 3'-0" 7'-0" 1 3/4" --- HM TP-1 --- 45 A HM TP-1 M4/A-510 J6/A-510 A7/A-510 HW-7B H283A
H283B VEST HALLWAY F 3'-0" 7'-0" 1 3/4" --- HM TP-1 --- 45 A HM TP-1 M4/A-510 J6/A-510 A7/A-510 HW-7B H283B
DOOR SCHEDULE THIRD FLOOR
NO.
ROOM LOCATION DOOR
RATING
(MIN.)
STC
FRAME
HARDWARE NO. COMMENTSFROM TO TYPE
OPENING
THICKNESS
UNDER
CUT MATERIAL FINISH FIRE TYPE MATERIAL FINISH
DETAILS
WIDTH HEIGHT HEAD JAMB SILL
THIRD FLOOR
370 OPEN WORK SPACE OFFICE F 3'-0" 7'-0" 1 3/4" --- HM TP-1 --- 50 A HM TP-1 M4/A-510 J6/A-510 A7/A-510 HW-7 370
371 OPEN WORK SPACE OFFICE F 3'-0" 7'-0" 1 3/4" --- HM TP-1 --- 50 A HM TP-1 M4/A-510 J6/A-510 A7/A-510 HW-7 371
372 OPEN WORK SPACE CONFERENCE ROOM F 3'-0" 7'-0" 1 3/4" --- HM TP-1 --- 50 A HM TP-1 M4/A-510 J6/A-510 A7/A-510 HW-7 372
374 OPEN WORK SPACE CER F 3'-0" 7'-0" 1 3/4" --- HM TP-1 --- 45 A HM TP-1 M4/A-510 J6/A-510 A7/A-510 HW-7 374
377 HALLWAY STORAGE F 3'-0" 7'-0" 1 3/4" --- HM TP-1 --- --- A HM TP-1 G16/A-510 C16/A-510 A12/A-510 HW-11 377
379 HALLWAY ELEC CLOSET F 3'-0" 7'-0" 1 3/4" --- HM TP-1 --- --- A HM TP-1 G16/A-510 C16/A-510 A12/A-510 HW-16 379
380 HALLWAY RR F 3'-0" 7'-0" 1 3/4" --- HM TP-1 --- --- A HM TP-1 M4/A-510 J6/A-510 A7/A-510 HW-19 380
381 HALLWAY RR F 3'-0" 7'-0" 1 3/4" --- HM TP-1 --- --- A HM TP-1 M4/A-510 J6/A-510 A7/A-510 HW-19 381
382 HALLWAY STORAGE F 3'-0" 7'-0" 1 3/4" --- HM TP-1 --- --- A HM TP-1 G16/A-510 C16/A-510 A12/A-510 HW-11 382
386 HALLWAY WEST STAIR N 3'-0" 7'-0" 1 3/4" --- HM TP-1 90 MIN --- A HM TP-1 M4/A-510 J6/A-510 A12/A-510 HW-2 386
387 HALLWAY EAST STAIR N 3'-0" 7'-0" 1 3/4" --- HM TP-1 90 MIN --- A HM TP-1 M4/A-510 J6/A-510 A12/A-510 HW-2 387
H300 VEST HALLWAY F 3'-0" 7'-0" 1 3/4" --- HM TP-1 --- 50 A HM TP-1 M4/A-510 J6/A-510 A7/A-510 HW-5 H300
H369 OPEN WORK SPACE VEST F 3'-0" 7'-0" 1 3/4" --- HM TP-1 --- 45 A HM TP-1 M4/A-510 J6/A-510 A7/A-510 HW-7B H369
H378 HALLWAY OPEN WORK SPACE F 3'-0" 7'-0" 1 3/4" --- HM TP-1 --- 50 A HM TP-1 M4/A-510 J6/A-510 A7/A-510 HW-6 H378
A
M E
N D
M E
N T
A U
G
DEAN C.
VON TERSCH
A-7903
CHARLESTON
SC
W
IS
CONSIN
A R
C H I T E C
T
-A
UG-2
W
2Q R
R
_P la ns -0
CONTROL ROOM
WITH VIDEO WALL
LAMARS
CONTROL ROOM
RED CELL
062A
BLUE CELL
062B
MS&A LAB SPACE
MS&A LAB SPACE
MS&A LAB SPACE
IMAGE
DEV/TEST/COLLAB
IMAGE IT
WORKROOM
066B
IMAGE SERVERS
066A
NOC/COMPUTERS
MS&A
WORKSTATIONS
ELECTRICAL
MS&A
WORKSTATIONS
MS&A LAB SPACE
OPEN OFFICE
MS&A LAB SPACE
072C
COMPUTERS
072B
MULTI-PURPOSE
CONTROL ROOM
072A
MS&A
WORKSTATIONS
RECONFIGURABLE
OPEN SPACE
ELEC CLOSET
NOC /
COMPUTERS
CER
HALLWAY
H112
ELEVATOR
EAST STAIR
WEST STAIR
VIDEO WALL
EQUIPMENT
ROOM
STORAGE ROOM
067A
CPT-6
CPT-4
STORAGE
CPT-6
SDT-2
CPT-6
CPT-5
SC-1 SC-1 SC-1 SC-1
CPT-4
CPT-4
SVT-4
CPT-4
SVT-4
SVT-4
SVT-3
SDT-2
CPT-5
CPT-4
CPT-6
CPT-4
CPT-5
CPT-4 CPT-4
CPT-5
SVT-3
SVT-3SDT-2
SVT-4 SVT-3
CPT-5
CPT-4
CPT-5
CPT-4
SVT-3
SVT-4CPT-6
CPT-4
CPT-6
CPT-4
CPT-6
CPT-4
CPT-5
SVT-4
SVT-3
SVT-1
SVT-3
SVT-3
SVT-4
SVT-4
SVT-3
SVT-3CPT-4
CPT-4
CPT-4
CPT-4
SVT-3
CPT-4
SVT-3
SVT-4
SDT-2
HALLWAY
H111
SVT-3
SVT-2
SVT-3
SVT-4
I3
I1
I3
I3 I3
I1
I1
I3
I3
I3
I3 I1
I1
I2
I1
I2
I3
I4
I4 I4
I2 I2
I2
I2I2
I4
I3
I4
I1
SVT-4
I4
CPT-6
1. FLOOR FINISH CHANGES SHALL OCCUR
UNDER THE DOOR CENTERLINE (OR
CENTER OF THE WALL OPENING IF NO
DOOR) BETWEEN ROOMS.
2. ALL RAILINGS AND GUARDRAILS TO
RECEIVE TP-2 UNLESS NOTED OTHERWISE
(UNO).
3. ALL WALLS ARE TO RECEIVE PT-1 UNO.
SEE FINISH SCHEDULE.
4. REFER TO ARCHITECTURE FOR
REFLECTED CEILING PLANS FOR CEILING
MATERIALS.
5. FLOOR FINISH TO CONTINUE UNDER ALL
FLOOR MOUNTED EQUIPMENT.
6. INSTALL THE FLOORING FINISH TO ALIGN
THE CENTER OF FINISH TO THE JOINT OF
THE RAISED ACCESS FLOORING SYSTEM,
SE FINISH DETAILS.
7. AT FINISH CHANGE, PROVIDE FULL PIECE
OF FINISH MATERIAL.
FIRST FLOOR
CPT-4 CPT-5 CPT-6 SC-1
SVT-1
SDT-2
SVT-2 SVT-3 SVT-4
GRAPHIC SCALE
164 8268
SCALE: 1/8"=1'-0"
GENERAL NOTES
SHEET KEYNOTES
FLOOR FINISH LEGEND
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
L O
U
IS
V
IL
L E
D
IS
T R
IC
T
D
R M
A R
T
IN
L U
T H
E R
K
IN
G P
L L O
U
IS
V
IL
L E
K
Y w w w .c e m s -a e .c o m
P
M
D a v e
Y e n s a n
P ro je c t:
C
.8
.3
PLAN NORTH
C E
M S
I-102
F
IR
S T
F L O
O R
F
IN
IS
H
P L A
N
W R
IG
H
T -P
A T
T E
R S
O N
A
IR
F O
R C
E B
A S
E K
C
A L H
O U
N
K C
A L H
O U
N
D V
O N
T E
R S
C H
J
U N
- - 4
P N
U M
B E
R
D R
A W
IN
G
C O
D E
C E
R T
IF
IE
D F
IN
A
L S
U B
M
IT
T A
L
R E
N O
V A
T E
R E
S E
A R
C H
F A
C
IL
IT
Y
F O
R M
S
A -F
P R
O J E
C T
N U
M B
E R
Z
H T
V
AREA OF WORK
KEYPLAN
SCALE: 1/8" = 1'-0"B1
FIRST FLOOR FINISH PLAN
I1 SEE FINISH DETAILS AND ACCENT PAINT
DETAILS FOR LIMITS OF ACCENT PAINT
COLOR. PAINT ACCENT PT-2.
I2 SEE FINISH DETAILS AND ACCENT PAINT
DETAILS FOR LIMITS OF ACCENT PAINT
COLOR. PAINT ACCENT PT-3.
I3 EXTENTS OF ACCENT PAINT COLOR ARE
CORNER TO CORNER, AND FLOOR TO
CEILING. ALL GYPSUM BOARD WITHIN THE
LIMITS WILL RECEIVE ACCENT COLOR PT-2.
I4 EXTENTS OF ACCENT PAINT COLOR ARE
CORNER TO CORNER, AND FLOOR TO
CEILING. ALL GYPSUM BOARD WITHIN THE
LIMITS WILL RECEIVE ACCENT COLOR PT-3.
A
M E
N D
M E
N T
A U
G
DEAN C.
VON TERSCH
A-7903
CHARLESTON
SC
W
IS
CONSIN
A R
C H I T E C
T
-A
UG-2
W
2Q R
R
_P la ns -0
S E
E A
R C
H
IT
E C
T U
R E
F O
R C
E
IL
IN
G
H E
IG
H
T S
L
IM
IT
O
F A
C C
E N
T C
O L O
R
LIMIT OF ACCENT COLOR
LIMIT OF ACCENT COLOR
2'-0" MAX OR TO CORNER OF WALL
SEE SIGNAGE PLAN
FOR SIGNAGE
INFORMATION
LATCH SIDE OF DOOR
SEE LEGEND OF
COLORS AND FINISHES
FOR DOOR AND FRAME
FINISH
K1
S E
E A
R C
H
IT
E C
T U
R E
F O
R C
E
IL
IN
G
H E
IG
H
T S
L
IM
IT
O
F A
C C
E N
T C
O L O
R
SEE SIGNAGE PLAN
FOR SIGNAGE
INFORMATION
SEE LEGEND OF
COLORS AND FINISHES
FOR DOOR AND FRAME
FINISH
LIMIT OF ACCENT COLOR
LIMIT OF ACCENT COLOR
2'-0" MAX OR TO CORNER OF WALL
LIMIT OF ACCENT COLOR
2'-0" MAX OR TO CORNER OF WALL
K8
RESILIENT
FLOORING
SUB FLOOR
CONCRETE
TRANSITION STRIP
RUBBER
TRANSITION STRIP
CARPET
SUB FLOOR
RESILIENT
SAW CUT SUB
FLOOR
EPOXY
FLOORING
SUB FLOOR
SEALED
CONCRETE
RUBBER
TRANSITION STRIP
RESILIENT
SUB FLOOR
RESILIENT
SAW CUT SUB
FLOOR
CONCRETE
FLOORING
SUB FLOOR
SEALED
CONCRETE
SAW CUT SUB
FLOOR
RESILIENT
FLOORING
SUB FLOOR
SEALED
CONCRETE
RUBBER
TRANSITION STRIP
CONTINUOUS
RETAINER
SPECIFIED WALL
SPECIFIED
CORNER GUARD
FASTENERS PER
MANUFACTURER
SPECIFICATION
3"
2'-0" x 2'-0"
RAISED ACCESS
FLOORING
SYSTEM
EQ EQ
E Q
E Q
SPECIFIED
CARPET FINISH
CENTERED ON
ACCESS PANEL
JOINTS
2'-0" x 2'-0"
RAISED ACCESS
FLOORING
SYSTEM
SPECIFIED
RESILIENT
FLOORING
ALIGNED TO
ACCESS PANEL
JOINTS
ALIGN
A L
IG
N
GRAPHIC SCALES
1 2 42
SCALE: 1/2"=1'-0"
3"3"
SCALE: 6"=1'-0"
02 1
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
L O
U
IS
V
IL
L E
D
IS
T R
IC
T
D
R M
A R
T
IN
L U
T H
E R
K
IN
G P
L L O
U
IS
V
IL
L E
K
Y w w w .c e m s -a e .c o m
P
M
D a v e
Y e n s a n
P ro je c t:
C
.8
.3
C E
M S
I-502
F
IN
IS
H
D E
T A
IL
S
W R
IG
H
T -P
A T
T E
R S
O N
A
IR
F O
R C
E B
A S
E K
C
A L H
O U
N
K C
A L H
O U
N
D V
O N
T E
R S
C H
J
U N
- - 4
P N
U M
B E
R
D R
A W
IN
G
C O
D E
C E
R T
IF
IE
D F
IN
A
L S
U B
M
IT
T A
L
R E
N O
V A
T E
R E
S E
A R
C H
F A
C
IL
IT
Y
F O
R M
S
A -F
P R
O J E
C T
N U
M B
E R
Z
H T
V
SCALE: 1/2" = 1'-0"
ACCENT PAINT DETAIL - SINGLE DOOR
SCALE: 1/2" = 1'-0"
ACCENT PAINT DETAIL - DOUBLE DOOR
SCALE: 6" = 1'-0"F1
TRANSITION DETAIL
SCALE: 6" = 1'-0"F6
TRANSITION DETAIL
SCALE: 6" = 1'-0"F11
TRANSITION DETAIL
SCALE: 6" = 1'-0"B2
TRANSITION DETAIL
SCALE: 6" = 1'-0"B6
TRANSITION DETAIL
SCALE: 6" = 1'-0"B11
TRANSITION DETAIL
SCALE: 6" = 1'-0"B15
CORNER GUARD DETAIL
SCALE: 1/2" = 1'-0"F15
RAISED ACCESS FLOORING FINISH DETAIL
A
M E
N D
M E
N T
A U
G
DEAN C.
VON TERSCH
A-7903
CHARLESTON
SC
W
IS
CONSIN
A R
C H I T E C
T
-A
UG-2
W
2Q R
R
_P la ns -0
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
L O
U
IS
V
IL
L E
D
IS
T R
IC
T
D
R M
A R
T
IN
L U
T H
E R
K
IN
G P
L L O
U
IS
V
IL
L E
K
Y w w w .c e m s -a e .c o m
P
M
D a v e
Y e n s a n
P ro je c t:
C
.8
.3
C E
M S
I-601
L E
G E
N D
O F
C O
L O
R S
A N
D F
IN
IS
H E
S
W R
IG
H
T -P
A T
T E
R S
O N
A
IR
F O
R C
E B
A S
E K
C
A L H
O U
N
K C
A L H
O U
N
D V
O N
T E
R S
C H
J
U N
- - 4
P N
U M
B E
R
D R
A W
IN
G
C O
D E
C E
R T
IF
IE
D F
IN
A
L S
U B
M
IT
T A
L
R E
N O
V A
T E
R E
S E
A R
C H
F A
C
IL
IT
Y
F O
R M
S
A -F
P R
O J E
C T
N U
M B
E R
Z
H T
V
LEGEND OF COLORS AND FINISHES
MARK MATERIAL MANUFACTURER STYLE COLOR SIZE COMMENTS
BASE
RB-1 RUBBER BASE TARKETT TRADITIONAL 63 BURNT UMBER TRADITIONAL 4" HEIGHT 120'-0" COILS
RB-2 RUBBER BASE TARKETT TRADITIONAL 40 BLACK 4" HEIGHT 40'-0" COILS
CEILING
ACG-1 ACOUSTICAL CEILING TILE GRID ARMSTRONG PRELUDE 15/16, WHITE --- USE WITH ACT-1
ACT-1 ACOUSTICAL CEILING TILE ARMSTRONG ULTIMA 1911, BEVELED TEGULAR, WHITE 2'-0" X 2'-0" USE WITH ACG-1
EXPOSED EXPOSED STRUCTURE --- PT-6 --- SEE CEILING FINISH NOTE 4 ON SHEET A-003
PT-6 CEILING PAINT SHERWIN WILLIAMS FLAT CEILING BRIGHT WHITE SW7007 --- ---
PT-7 CEILING PAINT SHERWIN WILLIAMS FLAT TRICORN BLACK SW6258 --- ---
FLOORING
CPT-1 CARPET TILE J&J FLOORING NON FICTION II 7026/3001 GLOSSARY 24" X 24" QUARTER TURN
CPT-2 CARPET TILE J&J FLOORING NON FICTION II 7025/1785 DIALOGUE 24" X 24" QUARTER TURN
CPT-3 CARPET TILE J&J FLOORING NON FICTION II 7025/3346 LEXICON 24" X 24" QUARTER TURN
CPT-4 CARPET TILE J&J FLOORING NON FICTION II 7026/3001 GLOSSARY 24" X 24" INSTALLED ON RAISED ACCESS FLOORING, TILE TABS MODULAR CARPET CONNECTORS, QUARTER TURN
CPT-5 CARPET TILE J&J FLOORING NON FICTION II 7025/1785 DIALOGUE 24" X 24" INSTALLED ON RAISED ACCESS FLOORING, TILE TABS MODULAR CARPET CONNECTORS, QUARTER TURN
CPT-6 CARPET TILE J&J FLOORING NON FICTION II 7025/3346 LEXICON 24" X 24" INSTALLED ON RAISED ACCESS FLOORING, TILE TABS MODULAR CARPET CONNECTORS, QUARTER TURN
EPX-1 EPOXY STONHARD ERF OR EQUAL TORGINAL BROADCAST FLAKE SYSTEM 1/4" FLAKES ACADIA FB-4208 --- INTEGRAL 4" BASE
RBT-1 RUBBER TILE MANNINGTON RESET BLACK TONES 828 24" X 24" ---
SC-1 SEALED CONCRETE --- --- --- CLEANED, PREPARED, SEALED
SDT-1 STATIC DISSIPATIVE SOLID VINYL TILE ARMSTRONG EXCELON SDT 51953 PEARL WHITE 12" X 12" ---
SDT-2 STATIC DISSIPATIVE SOLID VINYL TILE ARMSTRONG EXCELON SDT 51953 PEARL WHITE 12" X 12" INSTALLED, RAISED ACCESS FLOORING PER MANUFACTURER'S RECOMMENDED INSTALLATION METHODS
SVT-1 SOLID VINYL TILE TARKETT IQ OPTIMA FOGGY SHORES WG 24" X 24" ---
SVT-2 SOLID VINYL TILE TARKETT IQ OPTIMA 260 SHARKTALE WG 24" X 24" ---
SVT-3 SOLID VINYL TILE TARKETT IQ OPTIMA FOGGY SHORES WG 24" X 24" INSTALLED, RAISED ACCESS FLOORING PER MANUFACTURER'S RECOMMENDED INSTALLATION METHODS
SVT-4 SOLID VINYL TILE TARKETT IQ OPTIMA 260 SHARKTALE WG 24" X 24" INSTALLED, RAISED ACCESS FLOORING PER MANUFACTURER'S RECOMMENDED INSTALLATION METHODS
MISC.
CG-1 CORNER GUARDS INPRO CORP 150BN HIGH IMPACT CORNER GUARD 0380 GALA 3" WING SURFACE MOUNTED FLOOR-TO-CEILING
ETR EXISTING TO REMAIN --- --- --- ---
OP-1 OPERABLE PARTITION KWIK WALL SERIES 3020; FABRIC COVERING PARCHMENT 39-24 --- ---
PLAM-1 PLASTIC LAMINATE WILSONART 5022K-22 POLISHED CONCRETE PVC EDGEBAND KITCHENETTE CASEWORK
SS-1 SOLID SURFACE WILSONART 919RS YUKON RIVERSTONE --- KITCHENETTE COUNTERTOPS
TP-1 TRIM PAINT SHERWIN WILLIAMS SEMI GLOSS MEGA GREIGE SW7031 --- HOLLOW METAL DOOR FRAMES AND DOORS
TP-2 TRIM PAINT SHERWIN WILLIAMS SEMI GLOSS GRIFFIN SW7026 --- HANDRAILS/GUARDRAILS, STAIR LANDINGS, STRINGER, AND RISERS
WALLS
AWP-1 ACOUTISCAL WALL PANELS CARNEGIE OR EQUIVALENT FLIP 3XL METEOR 6427 COLOR 2000 24" X 48" SEE INTERIOR ELEVATIONS FOR ROOMS 062A AND 062B
PT-1 WALL PAINT SHERWIN WILLIAMS FLAT GRACIOUS GRIEGE HGSW2456 --- FIELD PAINT CONTRACTOR TO MATCH AT SHERWIN WILLIAMS
PT-2 WALL PAINT SHERWIN WILLIAMS FLAT WATERLOO SW9141 --- ACCENT PAINT
PT-3 WALL PAINT SHERWIN WILLIAMS FLAT PARAKEET SW6711 --- ACCENT PAINT
PT-5 WALL PAINT SHERWIN WILLIAMS FLAT TRICORN BLACK SW6258 --- BASEMENT
A
M E
N D
M E
N T
J U
L
A
M E
N D
M E
N T
A U
G
DEAN C.
VON TERSCH
A-7903
CHARLESTON
SC
W
IS
CONSIN
A R
C H I T E C
T
-A
UG-2
W
2Q R
R
_P la ns -0
PROVIDE (2) 2"
CONDUITS FROM
BOX TO 6" ABOVE
CEILING
OFFICE
WALL
12"x12" SURFACE MOUNTED
JUNCTION BOX. MOUNTING TO BE
COORDINATED WITH TV WALL MOUNT
TV RECEPTACLE TO
BE COORDINATED
WITH TV WALL MOUNT
DATA OUTLET (TYP.)
2" CONDUIT
1" CONDUIT
(GFCI VTC
MONITOR) VTC BOX
(60" AFF)
W A
L L
W A
L L
2" CONDUIT
JUNCTION BOX FOR
CAMERA, COORDINATE
EXACT MOUNTING
HEIGHT WITH USER
FINISHED FLOOR
DUPLEX RECEPTACLE (TYP.)
CEILING
2"
2' - 0" MIN.
1 1/2" TYP.
1"
1"
/8
3/8" DIA. HOLE TYP.
1/4" DIA. HOLE TYP.
1/2" NUT
1/4" DIA.
MOUNTING HOLE
TYP. OF 4
GENERAL NOTES:
1. ALL HARDWARE SHOWN SHALL BE STAINLESS STEEL.
2. PROVIDE 1 MOUNTING POINT PER 24" OF BAR LENGTH.
3. HOLES MAY BE ADDED IF REQUIRED.
1"
A
A
PLAN
SECTION A-A
2"
1/2" DIA.x2"L BOLT TYP OF 2
1/2" NUT
STEEL EXPANSION
ANCHOR FOR CMU
WALLS, SCREW TO
STUDS FOR GYP.
WALLS
1/2" LOCK WASHER
1/2" STANDARD WASHER
1/2" FENDER WASHERS (EACH
SIDE)
3" DEEP FIBERGLASS CHANNEL
SAME LENGTH AS CU BUSS
1" CONDUIT
W A
L L
W A
L L
QUAD POWER
OUTLET
FINISHED FLOOR
CEILING
1 1/2" CONDUIT
A F
F
DATA OUTLET
2" CONDUITS
12"x12" SURFACE
MOUNTED
JUNCTION BOX
A F
F
FLOOR
STRINGER
LISTED "U" CLAMP
TYPE CONNECTOR
OR APPOVED EQUAL
MOUNT AS LOW
AS POSSIBLE
#4/0 AWG CONDUCTOR
TO BE BONDED TO
EVERY OTHER LEG
PEDESTAL
GENERAL NOTES
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
L O
U
IS
V
IL
L E
D
IS
T R
IC
T
D
R M
A R
T
IN
L U
T H
E R
K
IN
G P
L L O
U
IS
V
IL
L E
K
Y w w w .c e m s -a e .c o m
P
M
D a v e
Y e n s a n
P ro je c t:
C
.8
.3
C E
M S
E-504
D E
T A
IL
S
W R
IG
H
T -P
A T
T E
R S
O N
A
IR
F O
R C
E B
A S
E N
H
E B
E L
N H
E B
E L
S P
E R
K
IN
S
J
U N
- - 4
P N
U M
B E
R
D R
A W
IN
G
C O
D E
C E
R T
IF
IE
D F
IN
A
L S
U B
M
IT
T A
L
R E
N O
V A
T E
R E
S E
A R
C H
F A
C
IL
IT
Y
F O
R M
S
A -F
P R
O J E
C T
N U
M B
E R
Z
H T
V
SCALE: NOT TO SCALEJ2
AV PULL BOX INSTALLATION DETAIL
SCALE: NOT TO SCALEJ10
AV WALL ELEVATION
SCALE: NOT TO SCALEB2
PRIMARY GROUNDING BAR DETAIL (PBB/SBB)
SCALE: NOT TO SCALEB10
CONFERENCE ROOM RACK WALL ELEVATION
1. SEE SHEET E-001 FOR LEGEND AND
GENERAL NOTES.
2. ALL EMPTY CONDUIT TO BE TO STUB UP
6 INCHES ABOVE CEILING AND BE
PROVIDED WITH A PULLSTRING.
SCALE: NOT TO SCALEJ15
RAISED FLOOR GROUNDING DETAIL
A
M E
N D
M E
N T
J U
L
A
M E
N D
M E
N T
A U
G
No. 21657
S
O
UT
H CAROLIN
A
R E G I S T E R E D
PR
OFESS I ON
A L
E N G I N E E R
R O B E
R T
S C O T T P E
R K I N
S
8/ 5/
W
2Q R
R
_P la ns -0
1.
2.
3.
NOTE:
GROUND ALL INCOMING METALLIC CONDUITS AND PIPING
TO THE PBB.
RACEWAY SHALL BE NON-METALLIC WHEN CONTAINING A
BONDING CONDUCTOR.
BOND CABLE TRAY SECTIONS USING #2 BARE COPPER OR #1/0 AL
BONDING JUMPER WITH TWO BOLTED COMPRESSION LUGS DEPENDING
ON THE MATERIAL OF CABLE TRAY. SCRAPE AWAY PAINT TO PROVIDE A
CLEAN SURFACE FOR THE LUG.
PANEL
RPH2B
CER 274
#1/0, 3/4"C
GBB
PANEL
RPH1B
GBB
PANEL
CDP2
ELEC ROOM B002
MGB
ELEC CLOSET B086
#4/0, 3/4"C
#4/0, 3/4"C
BASEMENT
RAISED
FIRST FLOOR
SECOND FLOOR
TBB/GE LINEAR
LENGTH M (FT)
TBB/GE SIZE (AWG)
TBB/GE LINEAR LENGTH M (FT)
LESS THAN 4 (13)
4-6 (14-20)
6-8 (21-26)
8-10 (27-33)
10-13 (34-41)
13-16 (42-52)
16-20 (53-66)
20-26 (67-84)
26-32 (85-105)
32-38 (106-125)
38-46 (126-150)
46-53 (151-175)
53-76 (176-250)
76-91 (251-300)
GREATER THAN 91 (301)
1/0
2/0
3/0
4/0
250 KCMIL
300 KCMIL
350 KCMIL
500 KCMIL
600 KCMIL
750 KCMIL
#1/0, 3/4"C
#1/0, 3/4"C
#300KCMIL, 1"C
ELEC CLOSET 279
SBB
#4/0, 3/4"C
PANEL
RPG2
#1/0, 3/4"C
PANEL
RPH3B
CER 374
#1/0, 3/4"C
SBB
THIRD FLOOR
ELEC CLOSET 379
GBB
#4/0, 3/4"C
PANEL
RPG3
#1/0, 3/4"C
ELEC CLOSET 076
PANEL
RPI1
GBB
#1/0, 3/4"C
R A
C K
TRAY
SBB
#1/0, 3/4"C
PANEL
RPGB
PBB
#1/0, 3/4"C
PANEL
RPG1
SBB
#1/0, 3/4"C
NOC/COMPUTERS 275
R A
C K
TRAY
SBB
#1/0, 3/4"C
NOC/COMPUTERS 375
R A
C K
TRAY
SBB
#1/0, 3/4"C
ELECTRICAL 069CER 074 NOC/COMPUTERS 075
#4/0, 3/4"C
#4/0, 3/4"C
#4/0, 3/4"C#4/0, 3/4"C
R A
C K
TRAY
SEE NOTE 3
#1/0, 3/4"C
R A
C K
TRAY
#1/0, 3/4"C
#4/0, 3/4"C
R A
C K
TRAY
#1/0, 3/4"C
BUILDING
STEEL COLUMN
GROUNDING
BOND PLATE
SEE NOTE 3
SEE NOTE 3 SEE NOTE 3
SEE NOTE 3SEE NOTE 3
EXISTING
GROUNDING
CONDUCTOR
#4/0, 3/4"C
PROVIDE GROUNDING CONDUCTOR
TO EXISTING SBB IN CER 080
TRAY
TRAY
#4/0, 3/4"C
RAISED
FLOOR
#4/0, 3/4"C
RAISED
FLOOR SEE NOTE 3SEE NOTE 3
#4/0, 3/4"C
RAISED
FLOOR
#4/0, 3/4"C
RAISED
FLOOR
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
L O
U
IS
V
IL
L E
D
IS
T R
IC
T
D
R M
A R
T
IN
L U
T H
E R
K
IN
G P
L L O
U
IS
V
IL
L E
K
Y w w w .c e m s -a e .c o m
P
M
D a v e
Y e n s a n
P ro je c t:
C
.8
.3
C E
M S
E-505
G R
O U
N D
IN
G
D E
T A
IL
W R
IG
H
T -P
A T
T E
R S
O N
A
IR
F O
R C
E B
A S
E N
H
E B
E L
N H
E B
E L
S P
E R
K
IN
S
J
U N
- - 4
P N
U M
B E
R
D R
A W
IN
G
C O
D E
C E
R T
IF
IE
D F
IN
A
L S
U B
M
IT
T A
L
R E
N O
V A
T E
R E
S E
A R
C H
F A
C
IL
IT
Y
F O
R M
S
A -F
P R
O J E
C T
N U
M B
E R
Z
H T
V
SCALE: NOT TO SCALEB2
BUILDING GROUNDING DETAIL
A
M E
N D
M E
N T
A U
G
No. 21657
S
O
UT
H CAROLIN
A
R E G I S T E R E D
PR
OFESS I ON
A L
E N G I N E E R
R O B E
R T
S C O T T P E
R K I N
S
8/ 5/
W
2Q R
R
_P la ns -0
| ARCHITECTURAL |
| A-109 - BASEMENT REFLECTED CEILING PLAN |
| A-113 - SPRAY ON FIREPROOFING PLANS |
| A-302 - WALL SECTIONS |
| A-401 - ENLARGED WEST STAIR PLANS AND SECTIONS |
| A-504 - SECURED AREA WALL AND CEILING DETAILS AND SEISMIC DETAILS |
| A-507 - DETAILS |
| A-511 - DOOR DETAILS |
| A-602 - DOOR SCHEDULE AND TYPES |
| INTERIORS |
| I-102 - FIRST FLOOR FINISH PLAN |
| I-502 - FINISH DETAILS |
| I-601 - LEGEND OF COLORS AND FINISHES |
| ELECTRICAL |
| E-504 - DETAILS |
| E-505 - GROUNDING DETAIL |
File details come from the government source that posted it. Updated .