These are architectural and engineering design files for Amendment 0002 of a U.S. Army Corps of Engineers renovation project at Wright-Patterson Air Force Base, Ohio. The project involves renovating Facility 20145, a high-bay research space, to create approximately 17,941 square feet of new secure laboratory space across three additional elevated floors and renovate 9,666 square feet of existing space. The renovation will include modeling, simulation and analysis laboratories, control rooms, and a Network Operations Center, with comprehensive upgrades to mechanical, electrical, plumbing, and communications systems.
The project requires compliance with Intelligence Community Directive (ICD) 705 requirements and multiple engineering standards, including UFC guidelines for HVAC, mechanical, electrical, and lighting systems, as well as NFPA codes for sprinkler systems, life safety, and electrical installations. The design files cover multiple disciplines including structural, architectural, mechanical, electrical, plumbing, fire protection, and telecommunications, with detailed plans for each floor and system, ensuring a comprehensive approach to the facility's renovation and modernization.
View the file
Other files
Show all 13
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
BUILDING #145
ACCESS ROAD 74
EIGHTH STREET
A C
C E
S S
R O
A D
BUILDING #146
BUILDING #45
PROJECT
AREA
CONTRACTOR VEHICLE AND
EQUIPMENT PARKING -
COORDINATE EXACT LOCATION
WITH CONTRACTING OFFICER
PHASE 3 LAYDOWN AND STORAGE
AREA. CONTRACTOR TO PROVIDE
BARRICADES/ FENCING
SURROUNDING WORK AREA.
PROVIDE SIGNAGE FOR DELIVERIES /
DUMPSTERS AND PARKING.
COORDINATE EXACT LOCATION WITH
CONTRACTING OFFICER.
MAINTAIN EMERGENCY DOORWAY
AND SIDEWALK EGRESS WITH
BARRICADES THROUGHOUT
CONSTRUCTION PROJECT
PROTECT UTILITY YARD.
PROVIDE CONTINUOUS
ACCESS THROUGHOUT
CONSTRUCTION PROJECT
NO CONTRACTOR PARKING
OUTSIDE OF LAYDOWN AREA -
USE PARKING LOT ON NORTH
SIDE OF BUILDING. VERIFY
LOCATION OF SPACES WITH
CONTRACTING OFFICER FOR
CONTRACTOR PARKING
PHASE 1 LAYDOWN AND STORAGE AREA. CONTRACTOR
TO PROVIDE BARRICADES / FENCING SURROUNDING
WORK AREA. PROVIDE SIGNAGE FOR DELIVERIES /
DUMPSTERS AND PARKING. COORDINATE EXACT
LOCATION WITH CONTRACTING OFFICER
CONTRACTOR SHALL MAINTAIN EXISTING
PARKING SPACES AS TEMPORARY
STORAGE AREA WITHIN BARRICADES
AND WILL NOT BE USED FOR PARKING
NO PARKING OUTSIDE OF
LAYDOWN / STORAGE AREA FOR
DURATION OF THE PROJECT
CONTRACTOR SHALL RESTORE
LAYDOWN AREA TO PRE-CONSTRUCTION
LEVELS INCLUDING GRASS ANS SEED
DO NOT BLOCK
DRIVE TO BUILDING
MAINTAIN EMERGENCY DOORWAY AND
SIDEWALK EGRESS WITH BARRICADES
THROUGHOUT CONSTRUCTION PROJECT
GUARD BOOTH
SECURE CONSTRUCTION
ZONE FENCE
ENTRY CONTROL POINT TO BUILDING
AT BASEMENT LEVEL AT SECURE
CONSTRUCTION ZONE FENCE
DO NOT BLOCK
DRIVE TO BUILDING
EXISTING EMERGENCY EGRESS ROUTE. ACCESS
TO REMAIN CLEAR. DO NOT BLOCK DRIVE
MAINTAIN EMERGENCY DOORWAY AND HALLWAY
EGRESS THROUGHOUT PHASE 3 OF THE
CONSTRUCTION PROJECT. COORDINATE WITH
BUILDING END-USER FOR ESCORT SERVICES
FOR PHASE 3 OF THE FIRST FLOOR RENOVATION
MAINTAIN SECURITY CLEARANCE
BETWEEN WORK AREA AND
LAMARS TRAINING ROOM
SITE SPECIFIC REQUIREMENTS ARE AS FOLLOWS:
1. ALL CONSTRUCTION WORKERS ARE REQUIRED TO BE U.S. CITIZENS. THE DOD REQUIRES
VERIFICATION OF IDENTITY AND CITIZENSHIP IN ACCORDANCE WITH THE REAL ID ACT.
2. CONTRACTOR WILL BE RESPONSIBLE FOR CONTROLLING SITE ACCESS. CONTRACTOR SHALL MAINTAIN
AN ENTRY AUTHORIZATION LIST (EAL) ENCOMPASSING ALL PERSONNEL GIVEN SITE ACCESS
INCLUDING BUT NOT LIMITED TO CONSTRUCTION WORKERS, VISITORS, DELIVERIES, ETC. EAL SHALL DOCUMENT PERSONNEL NAME, APPROPRIATE REAL ID ACT COMPLIANT IDENTIFICATION TYPE, ID
NUMBER, AND COMPANY / ORGANIZATION NAME.
3. EAL SHALL BE PROVIDED TO AFRL SITE SECURITY MANAGER (SSM) AT THE START OF RENOVATION
WITH MONTHLY UPDATES PROVIDED ON THE 1ST OF EACH MONTH THEREAFTER THROUGH THE
DURATION OF THE CONTRACT.
4. WHILE ON SITE PERSONNEL WILL BE REQUIRED TO HAVE A UNIQUE SITE SPECIFIC IDENTIFICATION TO
QUICKLY IDENTIFY THOSE PERSONNEL PERMITTED ON SITE AT ANY GIVEN TIME.
5. PERSONAL ELECTRONIC DEVICES (PED'S) WILL BE PROHIBITED WITHIN THE EXISTING FACILITY AT ALL TIMES INCLUDING BUT NOT LIMITED TO CELL PHONES, CAMERAS, COMPUTERS, ETC. TWO-WAY RADIOS
ARE PERMITTED THROUGHT THE CONSTRUCTION SITE PROVIDED THEY DO NOT HAVE ANY
PHOTOGRAPHIC OR RECORDING CAPABILITIES.
6. ALL PHOTOGRAPHS OF THE CONSTRUCTION SITE WILL BE ACCOMPLISHED BY AFRL. FOLLOWING REVIEW / APPROVAL BY THE AFRL SSM PHOTOGRAPHS WILL BE RELEASED TO THE CONSTRUCTION
CONTRACTOR AND CONTRACT ADMINISTRATOR AS NECESSARY.
7. SITE ACCESS SHALL BE LIMITED TO A SINGLE POINT OF ENTRY / EXIT. IF ADDITIONAL EXITS ARE REQUIRED FOR LIFE SAFETY DURING CONSTRUCTION THEY SHALL BE EXIT ONLY. CONTRACTOR TO PROVIDE ALL NECESSARY DOOR HARDWARE. SHOULD MATERIAL DELIVERIES BE REQUIRED AT AN ALTERNATE LOCATION IT SHALL BE COORDINATED AND DOCUMENTED IN THE CONTRACTOR'S DAILY
ACTIVITY LOG.
8. CONSTRUCTION LAYDOWN AREA SHALL BE PROVIDED WITH FENCING SURROUNDING APPROVED
LOCATION WITH A SINGLE ENTRY / DELIVERY GATE. A MINUMUM 6FT TALL CHAINLINK FENCE WITH PRIVACY FABRIC SHALL BE PROVIDED ALONG THE LAYDOWN AREA PERIMETER. LAYDOWN AREA SHALL BE LOCKED DURING NON-DUTY HOURS. AFRL LOCK WILL BE INCLUDED WITH THE CONTRACTOR LOCK ON THE ENTRY / DELIVERY GATE TO PERMIT ACCESS OF AFRL SSM AS NEEDED FOR INSPECTIONS.
9. CONSTRUCTION PERSONNEL REQUIRING ACCESS TO THE FIRST FLOOR RENOVATION AREA (PHASE 3)
SHALL BE ESCORTED AT ALL TIMES OR RECEIVE UNESCORTED ACCESS PER RQ EAST VISITOR
GUIDANCE SOP 16-01 DATED 01 JULY 2016. PROVIDE 2 WEEKS NOTICE FOR ESCORTS. ESCORTS WILL
ONLY BE AVAILABLE DURING NORMAL BUSINESS HOURS.
10. CONTRACTOR SHALL EXTEND UTILITIES TO THEIR TRAILERS.
11. CONTRACTOR SHALL PROTECT UNDERGROUND UTILITIES FROM HEAVY EQUIPMENT DAMAGE USED
DURING DEMO / EXCAVATION AND ERECTION ACTIVITIES.
SCOPE OF WORK
NOT IN SCOPE
SHEET HATCH LEGEND
NOTE: THE HATCHING SCOPE LIMITS
INDICATED ON THIS SHEET ARE GENERAL IN
NATURE. SEE SPECIFIC DISCIPLINE'S
DRAWINGS FOR SCOPE REQUIREMENTS AND
LIMITATIONS.
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
L O
U
IS
V
IL
L E
D
IS
T R
IC
T
D
R M
A R
T
IN
L U
T H
E R
K
IN
G P
L L O
U
IS
V
IL
L E
K
Y w w w .c e m s -a e .c o m
P
M
D a v e
Y e n s a n
P ro je c t:
C
.8
.3
PLAN NORTH
C E
M S
G-004
S
IT
E C
O N
S T
R U
C T
IO
N
S E
C U
R
IT
Y P
L A
N
W R
IG
H
T -P
A T
T E
R S
O N
A
IR
F O
R C
E B
A S
E O
H
IO
M L A
Z O
B M
C C
O Y
J T
O R
N E
R
J
U N
- - 4
P
N
U M
B E
R
D R
A W
IN
G
C O
D E
C E
R T
IF
IE
D F
IN
A
L S
U B
M
IT
T A
L
R E
N O
V A
T E
R E
S E
A R
C H
F A
C
IL
IT
Y
F O
R M
S
A -F
P R
O J E
C T
N U
M B
E R
Z
H T
V
SCALE: 1" = 50'-0"A1
SITE CONSTRUCTION SECURITY PLAN
AFRL CONSTRUCTION SITE SECURITY REQUIREMENTS
100'50'
SCALE: 1" = 50'
GRAPHIC SCALE
50'
A
M E
N D
M E
N T
J U
L
DEAN C.
VON TERSCH
A-7903
CHARLESTON
SC
W
IS
CONSIN
A R
C H I T E C
T
-J
UL-
W
2Q R
R
_P la ns -0
BUILDING #145
ACCESS ROAD 74
EIGHTH STREET
M
HDR
HDR
HDR
HDR
W
W W W W W W W W W W
W W
W W
W W
W W
W W
W W
WWWWWWWWW
W W
W W
W
W W
W W
W
W W
W
WWWW
W
WWWW
WWWWWWWWW
W
W
W
W
W
W W
AC
C
ES
S
R O
AD
PIV
BUILDING #146
BUILDING #22045
W W
W
W W W W W
WV
WV
WV
WV
WV
WV
WV
WV
WV
WV
WVWV
WV
WV
WV
WV
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
LO
U
IS
VI
LL
E
D
IS
TR
IC
T
D
R . M
AR
TI
N L
U
TH
ER
K
IN
G
P L
LO
U
IS
VI
LL
E, K Y w w w .c em s-ae .c om
PM
: D av e
Ye ns an
Pr oj ec t:
6C
3.
5.
C
EM
S
W R
IG
H
T-
PA
TT
ER
SO
N
A
IR
F O
R C
E
BA
SE
, O
H
IO
R
EN
O
VA
TE
R
ES
EA
R C
H F
AC
IL
IT
Y
FO
R
M S&
A- F2
PR
O
JE
C
T N
U M
BE
R
: Z H
TV
J
U N
- - P2 N
U M
BE
R
M .L
AZ
O
W .P
IE
R
C E
J.
TO
R N
ER
D R
AW
IN
G C
O D
E
C
ER
TI
FI
ED
F
IN
AL
S
U
BM
IT
TA
L
GRAPHIC SCALE
50'050'
SCALE: 1" = 50'
100'
! M
HDR
LEGEND
LEGENDCODE ITEM NOTES
ATS
NOT APPLICABLE
NOT APPLICABLE
EXISTING TO REMAIN
ASSUMED PROPERTY LINES
(PER UFC 3-600-01 1-7.2.4.2 (A))
FIRE DEPARTMENT ACCESS
(PER UFC 3-600-01 1-7.2.4.2 (C))
FIRE LANE MARKINGS AND
LOCATION (PER UFC 3-600-01
1-7.2.4.2 (D))
ANTITERRORISM SECURITY
(PER UFC 3-600-01 1-7.2.4.2 (E))
FIRE DEPARTMENT MAIN
ENTRANCE (PER UFC 3-600-01
1-7.2.4.2 (F))
FIRE DEPARTMENT
CONNECTIONS (PER UFC
3-600-01 1-7.2.4.2 (G))
HAZARDOUS MATERIAL
STORAGE TANKS (PER UFC
3-600-01 1-7.2.4.2 (K))
BACKFLOW PREVENTION
ASSEMBLY (PER UFC 3-600-01
1-7.2.4.2 (L))
ALONG EIGHTH STREET AND
ACCESS ROADS
EXISTING POST INDICATOR VALVE
FOR FIRE PROTECTION WATER LINE
PIV
EXISTING WATER
SUPPLY LINEW
HYDRANTS, VALVES AND
WATER LINES (PER UFC
3-600-01 1-7.2.4.2 (H))
EXISTING FIRE HYDRANT
EXISTING UNDERGROUND
WATER VALVE
WV
FOR REFERENCE ONLY.
NOT PART OF CONSTRUCTION CONTRACT.
EXISTING TO REMAIN
EXISTING FDC
NOT APPLICABLEFIRE PUMP ROOM (PER UFC
3-600-01 1-7.2.4.2(I))
FPR
EXISTING TO REMAIN
SCALE: 1" = 50'C1 CODE COMPLIANCE SITE PLAN
GI105
C O
D E
C O
M
PL
IA
N
C E
SI
TE
P
LA
N
AM
EN
D
M
EN
T
J U
L
M A R K A. L A Z O
S
O U
TH
CAROL IN
A
R E G I S T E R E D
PR
OF E
SS I ON
A L E N G I N E E R
No. 20943
07/24/2025
W
2Q R
R
_P la ns -0
DESIGN REFERENCES:
REFERENCE STANDARDS:
UFC 1-200-01 DoD BUILDING CODE, WITH CHANGE 1 (REV. OCT. 1, 2020)
UFC 3-301-01 STRUCTURAL ENGINEERING, WITH CHANGE 1 (REV. FEB. 4, 2022)
IBC 2018 INTERNATIONAL BUILDING CODE, 2018 EDITION
IEBC 2018 INTERNATIONAL EXISTING BUILDING CODE, 2018 EDITION
ASCE/SEI 7-16 MINIMUM DESIGN LOADS AND ASSOCIATED CRITERIA FOR
BUILDINGS AND OTHER STRUCTURES
RP 8 STANDARDS OF SEISMIC SAFETY FOR EXISTING FEDERALLY
OWNED AND LEASED BUILDINGS
UFC 4-010-01 DoD MINIMUM ANTITERRORISM STANDARDS FOR
BUILDINGS, WITH CHANGE 1 (REV. AUG. 19, 2020)
ACI 318-14 BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE
AISC 325 STEEL CONSTRUCTION MANUAL, 15TH EDITION
ANSI/AISC 360-16 SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS
TMS402/602-16 BUILDING CODE REQUIRMENTS FOR MASONRY STRUCTURES
EXISTING DRAWING SETS:
1. "FLIGHT CONTROL DEVELOPMENT LABORATORY - WRIGHT-PATTERSON AIR
FORCE BASE DAYTON, OHIO" (FEBRUARY 1976). SVERDRUP AND PARCEL
ASSOCIATES, INC. ST. LOUIS, MISSOURI.
REPORTS AND STUDIES:
1. "WPAFB RENOVATE RESEARCH FACILITY GEOTECHNICAL ENGINEERING
REPORT" (AUGUST 17, 2023) BY TERRACON. PROJECT NUMBER: N4215355.
GENERAL NOTES:
1. THE STRUCTURE IS DESIGNED AS A STABLE UNIT AFTER ALL COMPONENTS ARE IN PLACE.
THEREFORE, THE CONTRACTOR/ERECTOR SHALL DETERMINE ANY NEED FOR AND PROVIDE
ALL NECESSARY SHORING AND BRACING AS REQUIRED TO ENSURE STABILITY DURING
ERECTION.
2. ALL EXISTING CONDITIONS ARE SHOWN PER THE ORIGINAL BUILDING DRAWINGS AND NON-
DESTRUCTIVE SITE INVESTIGATIONS. THE GENERAL CONTRACTOR SHALL VERIFY ALL
DIMENSIONS AND CONDITIONS PRIOR TO DEMOLITION AND CONSTRUCTION.
3. WHEN A DETAIL IS SHOWN ON THE STRUCTURAL DRAWINGS FOR ONE CONDITION, IT SHALL
APPLY TO ALL SIMILAR OR LIKE CONDITIONS, UNLESS NOTED OR SHOWN OTHERWISE ON THE
DRAWINGS.
4. CONTRACTOR SHALL FULLY COORDINATE ALL DISCIPLINES' DRAWINGS (INCLUDING
DIMENSIONS AND ELEVATIONS) AND SHALL FULLY RESOLVE ANY CONFLICTS PRIOR TO
COMMENCING WORK.
5. FABRICATION DRAWINGS SHALL NOT BE REPRODUCTION OF STRUCTURAL CONTRACT
DRAWINGS.
6. MISCELLANEOUS STRUCTURAL ITEMS, CONDITIONS, OR PIECES OF STEEL MAY BE SHOWN ON
OTHER DISCIPLINES' DRAWINGS OR SHALL BE PROVIDED AS PER THE SPECIFICATIONS.
7. CONTRACTOR SHALL CONSULT GOVERNMENT FOR DIRECTION SHOULD UNCHARTED OR
INCORRECTLY CHARTED PIPING OR OTHER UTILITIES BE ENCOUNTERED DURING SITE
CLEARING, GRADING AND EXCAVATION.
8. NEW BUILDING DESIGN CRITERIA:
A. RISK CATEGORY II
B. GRAVITY LOADS - SEE LOAD DIAGRAMS ON S-002
C. SEISMIC LOADS
a. SEISMIC IMPORTANCE FACTOR, Ie: 1.00
b. MAPPED SPECTRAL RESPONSE SS = 0.147
S1 = 0.07
c. SOIL SITE CLASS: C
d. DESIGN SPECTRAL RESPONSE SDS = 0.127
SD1 = 0.07
e. SEISMIC DESIGN CATEGORY: B
f. LATERAL FORCE-RESISTING SYSTEM
• STEEL SYSTEMS NOT SPECIFICALLY DETAILED FOR SEISMIC RESISTANCE
RESPONSE MODIFICATION COEFFICIENT, R = 3
OVERSTRENGTH FACTOR, Ω = 3
DEFLECTION AMPLIFICATION FACTOR, Cd = 3
• FIRST FLOOR: STEEL CONCENTRICALLY BRACED FRAMES
• SECOND FLOOR AND ABOVE: STEEL MOMENT FRAMES
g. ANALYSIS: EQUIVALENT LATERAL FORCE PROCEDURE
h. SEISMIC BASE SHEAR COEFFICIENT, CS = 0.042
i. SEISMIC DESIGN BASE SHEAR, V = 56 KIPS
D. INTERIOR HORIZONTAL LIVE LOAD* 5 PSF
*NOTE: THE BUILDING IS ENTIRELY CONTAINED WITHIN AN EXISTING STRUCTURE.
THE MINIMUM HORIZONTAL LIVE LOAD PER IBC SECTION 1607.15 IS APPLIED.
9. REFER TO SPECIFICATION SECTION 01 11 00 FOR GENERAL PROVISIONS FOR PHASING
OF THE CONSTRUCTION WORK.
10. ATTACHMENTS SUPPORTING OVERHEAD MOUNTED ARCHITECTURAL AND MECHANICAL
FEATURES THAT WEIGH 31 LBS OR MORE SHALL BE DESIGNED, AT A MINIMUM, TO RESIST
0.5 TIMES THE COMPONENT WEIGHT IN ANY HORIZONTAL DIRECTION AND 1.5 TIMES THE
COMPONENT WEIGHT IN THE DOWNWARD DIRECTION.
STRUCTURAL STEEL NOTES:
1. 3/4" DIAMETER BOLTS SHALL BE USED IN ALL STRUCTURAL STEEL BOLTED CONNECTIONS U.N.O. TIGHTEN BOLTS TO
TENSION REQUIRED BY AISC. PROVIDE STANDARD HOLES U.N.O.
2. ANCHOR RODS SHALL BE ASTM F1554 Gr. 36, THREADED ON EACH END, WITH HEAVY HEX NUT AND WASHER AT
EACH END U.N.O.
3. ALL WELDED CONSTRUCTION SHALL BE IN ACCORDANCE WITH AWS D1.1, AISC 325, AND AISC 360.
4. WELDING SHALL BE PERFORMED ONLY BY OPERATORS AND WELDERS QUALIFIED BY THE AWS STANDARD
QUALIFICATION PROCEDURE TO PERFORM THE PARTICULAR TYPE OF WORK REQUIRED.
5. THERMAL CUTTING OF EXISTING STRUCTURAL STEEL SHALL NOT BE PERMITTED WITHOUT REVIEW AND APPROVAL
BY THE ENGINEER OF RECORD.
6. MEMBERS EXPOSED TO WEATHER IN FINISHED STRUCTURE SHALL BE GALVANIZED AFTER FABRICATION. DO NOT
WELD TO GALVZNIZED PORTIONS OF STEEL. PROVIDE TOUCH-UP OR REPAIR AS NEEDED PER ASTM A780.
7. STEEL BELOW GRADE SHALL BE PROTECTED BY A MINIMUM OF 3" OF CONCRETE.
8. GROUT UNDER BEARING PLATES SHALL BE OF NON-SHRINK, NON-METALLIC COMPOSITION.
9. NO SPLICES IN STRUCTURAL FRAMING MEMBERS ARE PERMITTED EXCEPT AS INDICATED OR APPROVED.
10. TENSION-CONTROL BOLTS SHALL HAVE A MECHANICALLY DEPOSITED ZINC FINISH.
11. FOR FRAMING AT CONCRETE SLABS OVER STEEL DECK, PROVIDE 3/4"-DIAMETER WELDED SHEAR STUDS AT 12" O.C.
UNLESS NOTED OTHERWISE.
A. 2" DECK + 3-1/4" LWC: STUD LENGTH 4-1/2"
12. STRUCTURAL STEEL SHALL BE AS FOLLOWS:
A. W-SHAPES ASTM A992
B. PLATES, ANGLES, CHANNELS, MISC. STEEL ASTM A36
C. HSS ASTM A1085
D. BOLTS, TENSION-CONTROL ASTM F3125, GRADE F1852-X
E. WELDING ELECTRODE E70XX
13. SEE SPECIFICATION 05 12 00 STRUCTURAL STEEL FOR ADDITIONAL INFORMATION.
1. STEEL DECK SHALL BE MINIMUM 3 SPAN CONDITION WITH THE FOLLOWING MINIMUM PROPERTIES.
A. LID:
a. 1-1/2" DEPTH, 20 GA, Fy = 50 ksi
b. In = 0.217 in4/ft. Ip = 0.197 in4/ft.
c. Sn = 0.229 in3/ft. Sp = 0.224 in3/ft.
d. SEE LID DECK FASTENING DETAIL ON S-104
B. FLOOR AND ELEVATOR HOISTWAY LID:
a. 2" DEPTH, 20 GA, Fy = 50 ksi
b. In = 0.407 in4/ft. Ip = 0.409 in4/ft.
c. Sn = 0.337 in3/ft. Sp = 0.326 in3/ft.
d. 3-1/4" LIGHTWEIGHT CONCRETE FILL (NO FILL AT ELEVATOR HOISTWAY LID)
e. 4x4-W2.9xW2.9 WWR AT MID-DEPTH OF CONCRETE ABOVE DECK FLUTES
2. SEE SPECIFICATION 05 30 00 STEEL DECKS FOR ADDITIONAL INFORMATION.
3. VERIFY A MINIMUM 2" DECK BEARING ON ALL SUPPORTS.
4. STEEL DECK PANELS MAY BE BUTTED OR END LAPPED AS NEEDED AT SUPPORTS, 2" MIN. LAP.
5. SEE SHEET S-506 FOR TYPICAL STEEL DECK DETAILS.
6. WHERE UNFILLED ROOF DECK CANTILEVERS MORE THAN 2'-0" BEYOND CENTERLINES, PROVIDE 20 GA STRAP
SUPPORTS @ 12" O.C.
STEEL DECK NOTES:
1. CONCRETE FOR FOUNDATION ELEMENTS, MISC. CONCRETE
A. CONCRETE COMPRESSIVE STRENGTH AT 28 DAYS: f'c = 4500 PSI (NWC) B. MAXIMUM WATER/CEMENTITIOUS RATIO (w/cm): 0.45
C. AIR CONTENT: 6% (± 1.5%)
D. NWC MAXIMUM UNIT WEIGHT 150 PCF
2. CONCRETE FOR ELEVATED SLAB ON STEEL DECK
A. CONCRETE COMPRESSIVE STRENGTH AT 28 DAYS: f'c = 4000 PSI (LWC) B. MAXIMUM WATER/CEMENTITIOUS RATIO (w/cm): 0.45
C. AIR CONTENT: NOT AIR-ENTRAINED
D. LWC MAXIMUM UNIT WEIGHT 115 PCF
3. REINFORCING STEEL SHALL BE ASTM A615, GRADE 60.
4. WELDED WIRE REINFORCEMENT SHALL BE ASTM A1064 AND PLACED AT MID DEPTH OF SLAB, U.N.O..
5. PROPORTION AND DESIGN CONCRETE MIXES TO RESULT IN CONCRETE SLUMP AT POINT OF PLACEMENT NOT
LESS THAN 3" AND NOT MORE THAN 5".
6. ADDITION OF WATER TO READY-MIX IN THE FIELD SHALL NOT BE ALLOWED.
7. DEPOSIT CONCRETE IN A CONTINUOUS OPERATION UNTIL THE PLACING OF CONCRETE IS COMPLETE. IF POUR IS
TO BE DISCONTINUOUS, CONTRACTOR SHALL USE CONSTRUCTION JOINTS.
8. CONCRETE MUST BE CURED FOR A MINIMUM 21 DAYS PRIOR TO ANY ADHESIVE ANCHOR INSTALLATION.
9. COMPLY WITH ACI 318 MINIMUM REINFORCEMENT PROTECTION REQUIREMENTS.
10. EXISTING REINFORCEMENT SHALL NOT BE DAMAGED OR DISTURBED BY INSTALLATION OF NEW ADHESIVELY
ANCHORED REINFORCEMENT. SEE FOUNDATION SECTIONS.
11. SEE SPECIFICATION 03 30 00 CAST-IN-PLACE CONCRETE FOR ADDITIONAL INFORMATION.
12. DEVELOPMENT (LDT) AND SPLICE (LST) LENGTHS FOR TYPICAL REINFORCING SIZES AND MIX DESIGNS ARE
SUMMARIZED IN THE TABLES BELOW:
CONCRETE NOTES:
COLD-FORMED METAL FRAMING NOTES:
1. COLD-FORMED STEEL DESIGN SHALL BE IN ACCORDANCE WITH THE AISI SPECIFICATION FOR THE
DESIGN OF COLD-FORMED STEEL STRUCTURAL MEMBERS, 2016 EDITION.
2. COLD FORMED STEEL SHALL BE DESIGNED FOR THE INTERIOR HORIZONTAL LIVE LOAD SHOWN IN
THE S-001 GENERAL NOTES.
3. DESIGN, DETAIL, AND ERECT COLD-FORMED METAL FRAMING IN ACCORDANCE WITH ASTM C955.
4. COLD-FORMED METAL FRAMING SIZES INDICATED ARE BASED ON A MINIMUM YIELD STRESS OF
50 KSI FOR 54 MILS AND GREATER THICKNESS (33 KSI FOR 43 MILS AND LESSER).
5. ALL EXTERIOR WALLS SHALL HAVE LATERAL BRIDGING UNLESS NOTED OTHERWISE.
6. COLD-FORMED METAL FRAMING SHALL BE GALVANIZED IN ACCORDANCE WITH A653, G60.
7. GALVANIZING DAMAGED BY INSTALLATION OPERATIONS OR WELDING SHALL BE REPAIRED USING
GALVANIZING REPAIR PAINT CONFORMING TO SSPC-PAINT 20 OR DOD-P-21035.
8. COLD-FORMED METAL FRAMING GAUGES AND SIZES ARE BASED UPON THE STEEL STUD
MANUFACTURERS ASSOCIATION (SSMA).
9. PROVIDE JOIST BRIDGING, BRACING, AND WEB STIFFENERS IN ACCORDANCE WITH COLD-FORMED
METAL FRAMING SYSTEM MANUFACTURER'S RECOMMENDATIONS AND AS INDICATED IN THESE
DRAWINGS, WHICHEVER IS THE GREATER REQUIREMENT.
10. PROVIDE METAL FRAMING SHOP DRAWINGS FOR REVIEW. AT CONTRACTOR'S OPTION, FRAMING
GAUGE AND SIZES MAY BE VARIED AT MANUFACTURER'S RECOMMENDATIONS UTILIZING THE
SPECIFIED FRAMING LOCATIONS AND SPANS. SHOULD CONTRACTOR CHOOSE AN ALTERNATE
METHOD, CONTRACTOR SHALL PROVIDE SHOP DRAWINGS SEALED BY A LICENSED ENGINEER AND
APPROVED BY THE ENGINEER OF RECORD.
MASONRY NOTES:
1. TYPICAL UNITS SHALL BE TWO-CELL TYPE UNITS.
2. MORTAR SHALL BE TYPE S WITH AN AVERAGE COMPRESSIVE STRENGTH OF 1,800 PSI AT 28 DAYS
CONFORMING TO ASTM C270.
3. CONCRETE MASONRY SHALL BE AS SPECIFIED BY ASTM C90. NET AREA COMPRESSIVE STRENGTH OF
CONCRETE MASONRY UNIT SHALL BE A MIN. 2,000 PSI. MINIMUM SPECIFIED COMPRESSIVE STRENGTH (f'm) SHALL BE 2,000 PSI PER TABLE 2 OF TMS 402/602-16 SPECIFICATIONS.
4. GROUT FOR USE IN MASONRY SHALL CONFORM TO ASTM C476 WITH A MINIMUM COMPRESSIVE
STRENGTH OF 2,000 PSI AT 28 DAYS.
5. ALL MASONRY SHALL BE PLACED IN A RUNNING BOND, U.N.O.
6. 21" MIN. TENSION LAP SPLICE FOR #5 BARS WITHIN CMU WALLS.
7. SEE SPECIFICATION SECTION 04 20 00 FOR ADDITIONAL INFORMATION.
MIX
REINF. DEVELOPMENT LENGTH, LDT (IN)
#3 #4 #5 #6
MIX
REINF. TENSION LAP SPLICE LENGTH, LST (IN)
4500 NWC
4000 LWC
#3 #4 #5 #6
4500 NWC
4000 LWC
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
L O
U
IS
V
IL
L E
D
IS
T R
IC
T
D
R M
A R
T
IN
L U
T H
E R
K
IN
G P
L L O
U
IS
V
IL
L E
K
Y w w w .c e m s -a e .c o m
P
M
D a v e
Y e n s a n
P ro je c t:
C
.8
.3
C E
M S
S-001
G E
N E
R A
L N
O T
E S
A N
D D
E S
IG
N
L O
A D
S
W R
IG
H
T -P
A T
T E
R S
O N
A
IR
F O
R C
E B
A S
E B
M
IN
O
R
P M
U R
R E
N
J L I
J
U N
- - 4
P
N
U M
B E
R
D R
A W
IN
G
C O
D E
C E
R T
IF
IE
D F
IN
A
L S
U B
M
IT
T A
L
R E
N O
V A
T E
R E
S E
A R
C H
F A
C
IL
IT
Y
F O
R M
S
A -F
P R
O J E
C T
N U
M B
E R
Z
H T
V
A
AFF ABOVE FINISHED FLOOR
& AND
APPROX. APPROXIMATE
ARCH. ARCHITECTURAL
@ AT
B
BM. BEAM
BOT. BOTTOM
B.O. BOTTOM OF
BF BRACED FRAME
BLDG. BUILDING
C
CLG. CEILING
CL. CENTERLINE
CLR. CLEAR
COL. COLUMN
CONC. CONCRETE
CMU CONCRETE MASONRY UNIT
CONN. CONNECTION
CONT. CONTINUOUS
C.J. CONTROL JOINT
COORD. COORDINATE
D
° DEGREE
DEMO. DEMOLITION
DET. DETAIL
Ø DIAMETER
DIM. DIMENSION
DWGS. DRAWINGS
E
EA. EACH
E.F. EACH FACE
E.W. EACH WAY
ELEC. ELECTRICAL OR ELECTRIC
EL. ELEVATION
E.O.R. ENGINEER OF RECORD
EQ. EQUAL
EX. EXISTING
E.J. (EXP. JT.) EXPANSION JOINT
EXP. EXPANSION/EXPOSED
EXT. EXTERIOR
F
F.S. FAR SIDE
FT. FEET
FIN. FINISH
F.F. FINISHED FLOOR
FLR. FLOOR
FTG. FOOTING
G
GA. GAGE OR GAUGE
GALV. GALVANIZED
Gr. GRADE
GB GRADE BEAM
H
HORIZ. HORIZONTAL
I
IN. INCH
I.D. INSIDE DIAMETER
INT. INTERIOR
J
JT. JOINT
JST. JOIST
K
KIP 1,000 POUNDS
KSI KIPS/SQUARE INCH
L
LFRS LATERAL FORCE-RESISTING
SYSTEM
LWC LIGHTWEIGHT CONCRETE
LLH LONG LEG HORIZONTAL
LLV LONG LEG VERTICAL
LONG. LONGITUDINAL
LST TENSION LAP SPLICE LENGTH
M
MATL. MATERIAL
MAX. MAXIMUM
MECH. MECHANICAL
MTL METAL
MPH MILE PER HOUR
MIN. MINIMUM
MISC. MISCELLANEOUS
MF MOMENT FRAME
N
N.S. NEAR SIDE
NWC NORMALWEIGHT CONCRETE
N.I.C. NOT IN CONTRACT
NTS NOT TO SCALE
NO. (#) NUMBER
O
O.C. ON CENTER
O.H. OPPOSITE HAND
O.D. OUTSIDE DIAMETER
P
PL PLATE
LBS. POUNDS
PCF POUNDS/CUBIC FOOT
PSF POUNDS/SQUARE FOOT
PSI POUNDS/SQUARE INCH
PT PRESSURE TREATED
PROJ. PROJECTION
R
REF. REFERENCE
RC REINFORCED CONCRETE
REINF. REINFORCEMENT
REQ'D REQUIRED
REV. REVISIONS / REVISED
S
SECT. SECTION
SIM. SIMILAR
S.O.G. SLAB ON GRADE
SL. SLOPE
SPEC. SPECIFICATION
SQ. SQUARE
S.S. STAINLESS STEEL
STD. STANDARD
STL. STEEL
STRUC. STRUCTURAL
T
T&B TOP & BOTTOM
T.O. TOP OF
TRANS. TRANSVERSE
TYP. TYPICAL
U
U.N.O. UNLESS NOTED OTHERWISE
V
V.I.F. VERIFY IN FIELD
VERT. VERTICAL
W
WWR WELDED WIRE
REINFORCEMENT
WF WIDE FLANGE
W/ WITH
W/O WITHOUT
WP WORKING POINT
A
M E
N D
M E
N T
J U
L
No. 29581
S
O
UT
H CAROLIN
A
B
R A D L E Y W. M I N
O
R
L I C E N S E D
P
RO
FESS I ONA L
E N G I N E E R
-J
UL-
W
2Q R
R
_P la ns -0
LOAD
TYPE
DESCRIPTION
MEP
SPRAY-ON FIREPROOFING
FLOOR FINISH
ACCESS FLOOR SELF WT. ALLOWANCE
TOTAL SUPERIMPOSED DEAD
OCCUPANCY - ACCESS FLOOR
SDL [psf] LL [psf]
ACCESS
FLOOR
4 -
LOAD SCHEDULE
1.5 -
2 -
9 -
25.5 -
- 100
STORAGE
OFFICE
CORRIDOR
LATRINE
IT ROOM
STAIR
SIMULATOR
KITCHEN
LID
MEP
SECURE CEILING
FLOOR FINISH
4 -
9 -
2 -
TOTAL SUPERIMPOSED DEAD
OCCUPANCY - LIGHT DUTY STORAGE
15 -
- 125 (NON)
MEP
SECURE CEILING
FLOOR FINISH
4 -
9 -
2 -
TOTAL SUPERIMPOSED DEAD
OCCUPANCY - OFFICE
15 -
- 50
MEP
SECURE CEILING
FLOOR FINISH
4 -
9 -
2 -
TOTAL SUPERIMPOSED DEAD
OCCUPANCY - CORRIDOR
15 -
- 80
MEP
SECURE CEILING
FLOOR FINISH
4 -
9 -
16 -
TOTAL SUPERIMPOSED DEAD
OCCUPANCY - LATRINE
29 -
- 75
MEP
SECURE CEILING
FLOOR FINISH
4 -
9 -
2 -
TOTAL SUPERIMPOSED DEAD
OCCUPANCY - CENTRAL IT ROOM
15 -
- 150 (NON)
STEEL STAIR/RAILING CONSTRUCTION
RUBBER STAIR TREAD/RISER COVER
25 -
1 -
TOTAL SUPERIMPOSED DEAD
OCCUPANCY - STAIR
26 -
- 100
MEP
SECURE CEILING
FLOOR FINISH
4 -
9 -
2 -
TOTAL SUPERIMPOSED DEAD
OCCUPANCY - SIMULATOR
15 -
- 125 (NON)
MEP
SECURE CEILING
PORCELAIN FLOOR TILE
4 -
9 -
16 -
TOTAL SUPERIMPOSED DEAD
OCCUPANCY - CORRIDOR
29 -
- 80
ACT CEILING
MEP
2.5 -
4 -
SPRAY-ON FIREPROOFING
OCCUPANCY - ROOF LIVE
1.5 -
- 20
ADDITIONAL PARTITION LIVE LOAD
TOTAL LIVE
- 15
- 65
TOTAL SUPERIMPOSED DEAD 23 -
5/8" TYPE X GYPSUM BOARD + 3/4"
WOOD FIBERBOARD
6 -
SECURE CEILING 9 -
SECURE CEILING 9 -
7 2 7
27 7
A
A
A
A
E
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
L O
U
IS
V
IL
L E
D
IS
T R
IC
T
D
R
M A
R T
IN
L
U T
H E
R K
IN
G
P L
L O
U
IS
V
IL
L E
K
Y w w w .c e m s -a e .c o m
P
M
D a v e
Y e n s a n
P ro je c t:
C
.8
.3
C E
M S
S-002
G E
N E
R A
L N
O T
E S
A N
D L
O A
D D
IA
G
R A
M S
W R
IG
H
T -P
A T
T E
R S
O N
A
IR
F O
R C
E B
A S
E B
M
IN
O
R
C H
A N
L E
Y
J L
I
J
U N
- - 4
P
N
U M
B E
R
D R
A W
IN
G
C O
D E
C E
R T
IF
IE
D F
IN
A
L S
U B
M
IT
T A
L
R E
N O
V A
T E
R E
S E
A R
C H
F A
C
IL
IT
Y
F O
R M
S
A -F
P R
O J E
C T
N U
M B
E R
Z
H T
V
H8
FIRST FLOOR LOAD DIAGRAM
H1
THIRD FLOOR LOAD DIAGRAM
M8
SECOND FLOOR LOAD DIAGRAM
M1
LID LOAD DIAGRAM
NOTES:
1. THE SECURE CEILING ASSEMBLY IS COMPRISED OF ACOUSTICAL INSULATION (1 PSF),
A METAL FRAMING SYSTEM (2 PSF), AND (2) LAYERS OF 5/8" GYPSUM BOARD (6 PSF).
ALLOWANCE IS MADE FOR TYPICAL SECURE CEILING INSTALLATION. REFER TO THE
ARCH. DWGS. FOR LOCATIONS WHERE SECURE CEILING WILL BE INSTALLED.
2. REPORTED OCCUPANCY LIVE LOADS ARE REDUCIBLE UNLESS NOTED WITH (NON).
3. PERIMETER CLADDING LOAD: 10 PSF
4. FILING CABINET (610 LB + 300 LB CONTENTS = 910 LB) WHERE SHOWN WITH:
5. ELEVATOR HOIST BEAM LOAD (7,500 LB)
WHERE SHOWN WITH:
A
PILE CAP AND MICROPILE NOTES:
1. CENTER ALL PILE CAPS BELOW COLUMNS AND PIERS, UNLESS NOTED OTHERWISE.
DIMENSIONS ON PLAN ARE REFERENCED FROM GRIDLINE TO CENTER OF MICROPILE,
UNLESS NOTED OTHERWISE.
2. MICROPILES SHALL BE INSTALLED WITH A MINIMUM BOND LENGTH IN SOUND
LIMESTONE BEDROCK OF AT LEAST 10 FEET. THE LOWER PART OF THE BOND ZONE
SHOULD CONTAIN AT LEAST 10 FEET OF CONTINUOUS SOUND BEDROCK. BEDROCK
CAN BE IDENTIFIED BASED ON DRILLING RATE AND OBSERVATION OF THE DRILL
CUTTINGS.
3. MICROPILES SHALL BE 6"Ø MINIMUM WITH FINAL SIZING PER THE MICROPILE DESIGNER.
THE MICROPILES SHALL BE CASED TO THE TOP ELEVATION OF COMPETENT BEDROCK.
4. THE ALLOWABLE UNIT BOND STRENGTH BETWEEN THE MICROPILE AND BEDROCK IS
37.5 PSI, WHICH INCLUDES A FACTOR OF SAFETY OF 2.0 (75 PSI NOMINAL).
5. MICROPILES SHALL BE INSTALLED IN A WAY THAT MINIMIZES VIBRATIONS AND OTHER
IMPACTS TO THE SURROUNDING STRUCTURE.
6. THE GROUP CAPACITY FOR MICROPILES IS THE LESSER OF 1) THE NUMBER OF
MICROPILES TIMES THE LATERAL OR VERTICAL LOAD CAPACITY OF A SINGLE
MICROPILE IN THE GROUP; OR 2) THE LATERAL OR VERTICAL LOADING CAPACITY OF AN
EQUIVALENT SINGLE BLOCK CONTAINING THE MICROPILES IN THE GROUP AND THE
SOIL BETWEEN THEM.
7. THE CONTRACTOR IS RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND
OBSTACLES TO THE MICROPILES AND FOUNDATIONS. THE CONTRACTOR SHALL
ENSURE THAT MICROPILES DO NOT STRIKE ANY EXISTING UNDERGROUND UTILITIES
OR OBSTACLES. MICROPILES MAY BE SHIFTED 6 INCHES IN ANY DIRECTION TO
ACCOMMODATE OBSTACLES. IF THE MICROPILE NEEDS TO MOVE GREATER THAN 6
INCHES, CONTACT THE CONTRACTING OFFICER FOR FURTHER DIRECTION.
8. INSTALL MICROPILES ORIENTED AS SHOWN ON PLAN.
9. ALL MICROPILE CAP REBAR SHALL HAVE STANDARD 180-DEGREE HOOKS AT EACH END.
10. BARS ARE EQUALLY SPACED IN PILE CAPS UNLESS NOTED OTHERWISE.
11. THE CONTRACTOR SHALL COORDINATE THE PILE DRIVER LOCATION WITH THE
CONTRACTING OFFICER.
12. PILE LOAD TESTS SHALL BE CONDUCTED. THE NUMBER OF TEST PILES FOR EACH
COMBINATION OF LENGTH, DIAMETER, AND REINFORCEMENT SHALL BE: 1) TWO
TENSION TEST PILES; 2) TWO COMPRESSION PILES; AND 3) ONE LATERAL TEST PILE.
13. REFER TO SPECIFICATION 31 63 33 FOR ADDITIONAL INFORMATION.
14. DESIGN INFORMATION AND ASD (ALLOWABLE) LOADS PER PILE ARE AS FOLLOWS:
A. HEAD CONDITION: PINNED
B. FACTOR OF SAFETY, FOS: 2.0
C. AXIAL COMPRESSION DOWNWARD: 85 KIPS
D. AXIAL TENSION UPLIFT: 37 KIPS
E. LATERAL: 6 KIPS
FOUNDATION NOTES:
1. STRUCTURAL FOUNDATION DESIGN IS BASED UPON AN ALLOWABLE SOIL BEARING CAPACITY OF
3000 PSF PER THE EXISTING DRAWING SET REFERENCED ON S-001 AND PER THE GEOTECHNICAL
ENGINEERING REPORT.
2. THE GROUND FROST PENETRATION LEVEL IS 49 INCHES BELOW GRADE PER UFC 3-301-01.
3. AS A PART OF INITIAL SITE PREPARATION ACTIVITIES, CONCRETE AND ANY OTHER SURFICIAL
DELETERIOUS MATERIAL (E.G. - DEBRIS, DESICCATED SOIL, HIGH ORGANIC CONTENT SOIL, UNSUITABLE FILL, ETC.) SHOULD BE COMPLETELY REMOVED AND STRIPPED TO EXPOSE THE UNDERLYING SUITABLE SOILS IN AREAS THAT WILL RECEIVE STRUCTURAL FILL TO SUPPORT THE PROPOSED FOUNDATIONS.
REMOVAL SHOULD BE EVALUATED BY THE CONTACTOR'S PROFESSIONAL GEOTECHNICAL ENGINEER.
4. REMOVAL AND/OR RELOCATION OF ANY TO-BE-ABANDONED UTILITIES AND/OR DUCTS SHALL BE
PERFORMED PRIOR TO ROUGH SITE GRADING ACTIVITIES.
5. CONCRETE SLABS ON GRADE IN ENCLOSED HABITABLE AREAS SHALL BE UNDERLAIN BY A CAPILLARY WATER BARRIER COMPRISED OF A MINIMUM OF 6 INCHES OF FREE-DRAINING (LESS THAN 6% PASSING THE U.S. NO. 200 SIEVE) CRUSHED AGGREGATE COMPACTED TO AT LEAST 98% OF ASTM D698.
6. BELOW ALL BUILDING CONCRETE SLABS ON GRADE, PROVIDE A VAPOR RETARDER COMPRISED OF
LAPPED POLYETHYLENE SHEETING WITH MINIMUM THICKNESS OF 10 MILS.
7. CONTRACTOR IS RESPONSIBLE FOR DETERMINING NEED FOR AND PROVIDING ALL REQUIRED
TEMPORARY SHORING AND BRACING DURING DEMOLITION AND CONSTRUCTION. PROVIDE
TEMPORARY UNDERPINNING OR SHORING AS REQUIRED FOR EXISTING FOUNDATIONS.
8. EXISTING FOUNDATIONS SHALL NOT BE DAMAGED OR DISTURBED.
9. ALL FOUNDATIONS ARE TO BEAR ON UNDISTURBED IN SITU SOIL OR ON TESTED STRUCTURAL
BACKFILL. FILL SHALL BE PLACED IN UNIFORM LIFTS OF NO MORE THAN 8 INCHES THICK AND COMPACTED TO 98% STANDARD PROCTOR VALUE FOR BACKFILL IN ACCORDANCE WITH ASTM D698 (THIS INCLUDES THE LAYER OF CLEAN WASHED GRANULAR FILL FOR SLABS ON GRADE). THE MAXIMUM PARTICLE SIZE FOR FILL PLACEMENT SHALL NOT EXCEED 2/3 OF THE LIFT THICKNESS NOR SPECIFIED
MAXIMUM PARTICLE SIZE.
10. MAINTAIN POSITIVE SURFACE DRAINAGE TO PREVENT THE ACCUMULATION OF WATER IN EXCAVATED
AREAS.
11. MATERIAL TO BE USED AS FILL SHALL BE TESTED BY AN APPROVED TESTING LABORATORY TO
DETERMINE SUITABILITY PRIOR TO BEING PLACED.
12. SURFACE AREAS AT GRADE AND AREAS TO RECEIVE FILL SOILS SHALL BE DETERMINED WITHIN ±2
PERCENTAGE POINTS OF THE OPTIMUM MOISTURE CONTENT DETERMINED FROM THE STANDARD
PROCTOR TEST.
13. IMMEDIATELY PRIOR TO CONSTRUCTION, SUBGRADE SOILS SHALL BE PROOF ROLLED WITH A FULLY LOADED TANDEM-AXLE DUMP TRUCK OR SIMILAR EQUIPMENT TO DETECT ANY UNSTABLE AREAS. THE PROOF ROLLING EQUIPMENT SHALL MAKE A MINIMUM OF FOUR PASSES OVER EACH SECTION, WITH THE LAST TWO PASSES PERPENDICULAR TO THE FIRST TWO. ANY AREAS WHICH PUMP OR RUT SHALL BE UNDERCUT OR SCARIFIED AND DENSIFIED IN PLACE AND PROOF ROLLED AGAIN. CONTRACTOR
SHALL NOTIFY OWNER PRIOR TO COMMENCEMENT OF PROOF ROLLING OPERATIONS.
14. FILL PLACEMENT SHALL NOT BEGIN UNTIL PROOF ROLLING OPERATIONS ARE SUCCESSFUL.
15. DURING CONSTRUCTION, ALL FOUNDATION EXCAVATIONS AND SOIL/GROUNDWATER CONDITIONS
SHALL BE INSPECTED AND APPROVED BY THE CONTRACTOR'S PROFESSIONAL GEOTECHNICAL
ENGINEER PRIOR TO PLACING CONCRETE.
E
A
M E
N D
M E
N T
J U
L
No. 29581
S
O
UT
H CAROLIN
A
B
R A D L E Y W. M I N
O
R
L I C E N S E D
P
RO
FESS I ONA L
E N G I N E E R
-J
UL-
W
2Q R
R
_P la ns -0
15.5
GHJKLM J.2
12.1
13.2
13.3
14.4
14.9
L.2L.9 J.9 J.4 H.5 G.5
1'-11" 14'-0" 24'-5" 14'-0" 14'-5" 9'-7"
S10
S10
S10
S10
S11
S7
S8
TYP.
TYP.
S12
EXISTING
CONTROL ROOM
CEILING FRAMING
EXISTING STEEL
COLUMN, TYP.
W12X19 (14) W12X19 (24) MF W16 W12X19 (14) W12X19 (9)
W10X15 (14)
W10X15 (14)
W10X15 (14)
W10X15 (14)
W10X15 (14)
W10X15 (14)
W10X15 (14)
W14X22 (24)
W14X22 (24)
W14X22 (24)
W14X22 (24)
W14X22 (24)
W14X22 (24)
W16X26 (24)
HSS8X4X3/8
H S
S x x /8
W X
W X
HSS14X4X1/4 HSS14X4X1/4 W12X19 (9)
W X
W10X15 (14)
W10X15 (14)
W10X15 (14)
W10X15 (14)
W10X15 (14)
W10X15 (14)
MF W16
W10X15 (14)
W10X15 (14)
W10X15 (14)
W10X15 (14)
W10X15 (14)
W10X15 (14)
W10X15 (9)
W10X15 (9)
W10X15 (9)
W10X15 (9)
W10X15 (9)
W10X15 (9)
W10X15 (9)
W X
(2
W X
W X
W X
W X
W X
M F
W
W X
W X
W X
W X
M F
W
W10X15 (6)
S17
G1 S-201
G12 S-201
A12 S-201
A1 S-201
HSS6x4x1/4 TYP.
AROUND ELEVATOR
H S
S X
X
/8
E Q
E
Q
E Q
E Q
E
Q
E Q
E
Q
5"
4'-11"9'-2" 11'-0"
C14 S-202
C1 S-202
4"
5"
/2
2"
SEE SHEET S-601
FOR POSTS AT
ELEVATOR AREA, TYP.
S8 S8
S8
2"
1. ALL EXISTING CONDITIONS ARE SHOWN
PER ORIGINAL BUILDING DRAWINGS AND
NON-DESTRUCTIVE SITE
INVESTIGATIONS. GENERAL
CONTRACTOR SHALL VERIFY ALL
DIMENSIONS, ELEVATIONS, AND
CONDITIONS PRIOR TO AND DURING
DEMOLITION AND CONSTRUCTION.
2. SECOND FLOOR T.O. SLAB IS AT
ELEV. +913'-0".
3. THIRD FLOOR T.O. SLAB IS AT
ELEV. +926'-0".
4. STEEL FRAMING IS CENTERED ON
GRIDLINES AND SPACED EQUALLY U.N.O.
NEW FRAMING
EXISTING FRAMING
LATERAL FORCE-RESISTING
SYSTEM MOMENT CONNECTION
NON-LATERAL
MOMENT CONNECTION
STEEL DECK
SPAN DIRECTION
T
T
T-1/16
PJP, 4
SIDES
HSS POST, TYP.
CAP PLATE, TYP. AT
TOP OF HSS POST
WF BEAMS, SEE PLAN
TYP
TYP
HSS14x4 POST, SEE PLAN
DOUBLE ANGLE SHEAR
CONNECTION, TYP.
BOLTS IN STANDARD
HOLES, TYP.
GRAPHIC SCALES
SCALE: 1 1/2"=1'-0"
164 8268
SCALE: 1/8"=1'-0"
LEGEND
GENERAL NOTES
SHEET KEYNOTES
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
L O
U
IS
V
IL
L E
D
IS
T R
IC
T
D
R
M A
R T
IN
L
U T
H E
R K
IN
G
P L
L O
U
IS
V
IL
L E
K
Y w w w .c e m s -a e .c o m
P
M
D a v e
Y e n s a n
P ro je c t:
C
.8
.3
PLAN NORTH
C E
M S
S-103
S E
C O
N D
A N
D T
H
IR
D F
L O
O R
F R
A M
IN
G
P L A
N
W R
IG
H
T -P
A T
T E
R S
O N
A
IR
F O
R C
E B
A S
E B
M
IN
O
R
P
M U
R R
E N
J L
I
J
U N
- - 4
P
N
U M
B E
R
D R
A W
IN
G
C O
D E
C E
R T
IF
IE
D F
IN
A
L S
U B
M
IT
T A
L
R E
N O
V A
T E
R E
S E
A R
C H
F A
C
IL
IT
Y
F O
R M
S
A -F
P R
O J E
C T
N U
M B
E R
Z
H T
V
SCALE: 1/8" = 1'-0"C1
SECOND AND THIRD FLOOR FRAMING PLAN
S7 NEW STEEL GRAVITY COLUMN. SEE
S-601 SCHEDULE.
S8 NEW STEEL HSS5x5 POST.
S10 NEW STEEL WIDE-FLANGE MOMENT
FRAME BEAM.
S11 NEW COMPOSITE STEEL WIDE-FLANGE
BEAM.
S12 NEW 3-1/4"-THICK LIGHTWEIGHT
CONCRETE SLAB ON 2" STEEL DECK.
SEE S-001 FOR PROPERTIES AND
REINFORCEMENT.
S17 NEW STEEL HSS14x4 POST.
AREA OF WORK
KEYPLAN
SCALE: 1 1/2" = 1'-0"M12
HSS CAP PLATE DETAIL
SCALE: 1 1/2" = 1'-0"J12
TYP. HSS14x4 POST CONNECTIONS
A
M E
N D
M E
N T
J U
L
No. 29581
S
O
UT
H CAROLIN
A
B
R A D L E Y W. M I N
O
R
L I C E N S E D
P
RO
FESS I ONA L
E N G I N E E R
-J
UL-
25 W
2Q R
R
_P la ns -0
T.O. SLAB L1
898' - 8"
1/4 4
WP
LWC SLAB ON
STEEL DECK
BRACED FRAME BEAM,
SEE ELEVATION
HSS BRACE,
SEE ELEVATION
SHEAR CONNECTION
COMPOSITE STEEL BEAM,
SEE PLAN
BRACED FRAME COLUMN,
SEE ELEVATION
PL3/4 GUSSET PLATE
1/4 16
1/4
T Y
P
/2
T Y
P
(2) L4x3x3/8 CONNECTION ANGLES
WITH (9)-3/4"Ø BOLTS, (4) BOLTS
AT BEAM, (5) BOLTS AT GUSSET.
PROVIDE SHIMS AS NEEDED.
1 1/2"
COPE BEAM
BOTTOM FLANGE
PL3/4x9x1'-8"
THROUGH- PLATE
1/4
1/4 4
TYP.
TYP.1 1
/2
TY
P
2"
HSS BRACE,
SEE ELEVATION
HSS BRACE,
SEE ELEVATION
5" TY
P
BASEMENT
879' - 9"
6"
TYP.
1"
1/4 8
1/4 4
PL3/4 GUSSET PLATE HSS BRACE, SEE
ELEVATION
BASE PLATE AND ANCHOR
RODS, SEE A12/S-501.
1/2" EXPANSION MATERIAL
CONCRETE INFILL AT
ISOLATION POCKET
BRACED FRAME COLUMN,
SEE ELEVATION
(5) #3 CLOSED TIES, TYP.
WP
1/4 24
(6) ADD'L #3 STIRRUPS
HOOKED AROUND
GRADE BEAM REINF.
MICROPILE CAP, SEE PLAN
RC GRADE BEAM, SEE PLANMICROPILE BEYOND, SEE PLAN
B1 S-502
A12 S-501
BEAM DESIGN SHEAR (KIPS)
W12x19 - W12x26
W14x22
W16x26 - W16x36
W18x40 44
W10x15
NOTES:
1. DESIGN SHEAR
CONNECTIONS TO SUPPORT,
AT MINIMUM, THE DEMANDS
SHOWN.
2. THE DEMANDS SHOWN
CORRESPOND TO LRFD
ULTIMATE DESIGN SHEARS.
3. SUBMIT FOR REVIEW
DETAILS AND CALCULATIONS
STAMPED BY A REGISTERED
PROFESSIONAL ENGINEER.
4. REFER TO SPECIFICATION
SECTION 05 12 00 FOR
ADDITIONAL
REQUIREMENTS.
SHEAR CONNECTIONS
HSS6x4, HSS8x4 10
HSS14x4 12
CJP
2" 2"
CL
NOTES:
1. WELD COLUMN FLANGES FIRST, THEN REMOVE
CHANNELS AND WELD COLUMN WEB.
2. SPLICE CONCEPT SHOWN. SPLICES TO BE DESIGNED
BY DELEGATED CONNECTIONS DESIGNER.
3. SPLICES SHALL DEVELOP FULL CAPACITY OF
SPLICED COLUMN SECTIONS.
4. REFER TO S-201 ELEVATIONS FOR COLUMN SIZES.
CONTRACTOR TO COORDINATE SPLICE LOCATIONS.
5. PROVIDE MILLED FINISHES AT COLUMN ENDS.
SLIP-CRITICAL
ERECTION BOLTS
CHANNEL FOR
ERECTION PURPOSES
LIFTING HOLE AT
CONTRACTOR'S
OPTION
WF MOMENT
FRAME COLUMN
A B
O V
E F
L O
O R
L E
V E
L
1 1/2" 3" 3" 1 1/2"
MOMENT CONNECTION SCHEDULE
BEAM
FLANGE PLATE
FLANGE BOLTS
WEB PLATES
WEB BOLTS
W16x31 W16x57
PL3/8x5x0'-9"
(3) - 3/4"Ø
2 ROWS
PL5/8x4x1'-1"
1 PLATE
(4) - 3/4"Ø
PL3/4x8x0'-9"
(3) - 3/4"Ø
2 ROWS
PL 5/8x4x1'-1"
1 PLATE
(4) - 3/4" Ø
NOTES:
1. SLAB ON STEEL DECK NOT SHOWN FOR CLARITY.
2. ALL MOMENT CONNECTION BOLT HOLES SHALL BE STANDARD HOLES.
SHEAR CONNECTION
COMPOSITE STEEL
BEAM, SEE PLAN
STEEL MF COLUMN,
SEE ELEVATIONFLANGE PLATE,
SEE SCHEDULE
STEEL MF BEAM,
SEE ELEVATION
WEB PLATES
AT EACH SIDE,
SEE SCHEDULE
5/16
TYP.
5/16
TYP
CONTINUITY PLATE AT EACH
FLANGE, TYP. WITH THICKNESS
TO MATCH FLANGE PLATE
3/16
TYP. 3
SIDES
1"
2'-2"
SEE
DETAIL
1/4 3/16
TYP
PL1-1/4x10x2'-2" BASE PLATE
(6) 1"Ø ANCHOR RODS
WITH 15" EMBEDMENT
NOTES:
1. PROVIDE 1-7/8"Ø OVERSIZED HOLES FOR BASE PLATE ANCHOR RODS.
2. PROVIDE PL3/8x3x0'-3" PLATE WASHERS AT EACH ANCHOR ROD.
1 1/2" 9" 9" 6 1/2"
BASEMENT
879' - 9"
1/4 6
1/4 4
PL3/4 GUSSET PLATE
HSS BRACE,
SEE ELEVATION
BASE PLATE AND ANCHOR
RODS, SEE A12/S-501
1/2" EXPANSION
MATERIAL
CONCRETE INFILL AT
ISOLATION POCKET
BRACED FRAME COLUMN,
SEE ELEVATION
(5) #3 CLOSED TIES, TYP.
WP
1/4 14
(6) ADD'L #3 STIRRUPS
HOOKED AROUND
STEM WALL REINF.
MICROPILE
CAP, SEE PLAN
CASED MICROPILES,
SEE PLAN
EXISTING RC STRIP
FOOTING BEYOND
6"
TY
P .1"
" #5 HORIZ. @ 12" O.C. E.F.
#5 @ 18" O.C. E.F. VERT. ADHESIVE
DOWELS WITH 8" EMBED. INTO
FOUNDATION BELOW
RC STEM WALL,
SEE PLAN
A12 S-501
RC T-SHAPED
PEDESTAL, SEE PLAN
O.H.
T.O. SLAB L1
898' - 8"
1/4 4
WP
LWC SLAB ON
STEEL DECK
BRACED FRAME BEAM,
SEE ELEVATION
HSS BRACE,
SEE ELEVATION
SHEAR CONNECTION
COMPOSITE STEEL
BEAM, SEE PLAN
BRACED FRAME COLUMN,
SEE ELEVATION
PL3/4 GUSSET PLATE
1/4 28
1/4
(2) L4x3x3/8 CONNECTION ANGLES
WITH (8)-3/4"Ø BOLTS, (4) BOLTS
AT BEAM, (4) BOLTS AT GUSSET.
PROVIDE SHIMS AS NEEDED.
COPE BEAM
BOTTOM FLANGE
T Y
P
T Y
P
/2
1 1/2" 2 1/2"
GRAPHIC SCALE
1/2 1 21
SCALE: 1"=1'-0"
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
L O
U
IS
V
IL
L E
D
IS
T R
IC
T
D
R
M A
R T
IN
L
U T
H E
R K
IN
G
P L
L O
U
IS
V
IL
L E
K
Y w w w .c e m s -a e .c o m
P
M
D a v e
Y e n s a n
P ro je c t:
C
.8
.3
C E
M S
S-501
S T
E E
L L
F R
S C
O N
N E
C T
IO
N
D E
T A
IL
S
W R
IG
H
T -P
A T
T E
R S
O N
A
IR
F O
R C
E B
A S
E B
M
IN
O
R
C H
A N
L E
Y
J L
I
J
U N
- - 4
P
N
U M
B E
R
D R
A W
IN
G
C O
D E
C E
R T
IF
IE
D F
IN
A
L S
U B
M
IT
T A
L
R E
N O
V A
T E
R E
S E
A R
C H
F A
C
IL
IT
Y
F O
R M
S
A -F
P R
O J E
C T
N U
M B
E R
Z
H T
V
SCALE: 1" = 1'-0"
B1
S-102 K1
E-W BRACE LEVEL 1 CONNECTION DETAIL
SCALE: 1" = 1'-0"
A1
S-201 A1
BRACE INTERSECTION DETAIL
SCALE: 1" = 1'-0"
B1
S-101 E1
E-W BRACE FOUNDATION CONNECTION DETAIL
SCALE: NOT TO SCALEL15
DELEGATED CONNECTION DESIGN CRITERIA
SCALE: 1" = 1'-0"A6
MF COLUMN SPLICE
SCALE: 1" = 1'-0"D15
TYPICAL MOMENT CONNECTION DETAIL
SCALE: 1" = 1'-0"
D9
S-501 A12
BRACE FOUNDATION CONNECTION PLAN
SCALE: 1" = 1'-0"
B1
S-101 D9
N-S BRACE FOUNDATION CONNECTION DETAIL
SCALE: 1" = 1'-0"
B1
S-102 K9
N-S BRACE LEVEL 1 CONNECTION DETAIL
A
M E
N D
M E
N T
J U
L
No. 29581
S
O
UT
H CAROLIN
A
B
R A D L E Y W. M I N
O
R
L I C E N S E D
P
RO
FESS I ONA L
E N G I N E E R
-J
UL-
W
2Q R
R
_P la ns -0
T.O. SLAB
EL: SEE PLAN
1'-4" D
DECK PERPENDICULAR
/4
BEAM AT DECK EDGE
OR OPENING EDGE
DECK CLOSURE PLATE,
THICKNESS TO MATCH DECK GAGE
FOR 1'-0" < D ≤ 2'-6", PROVIDE
HOOKED #4 @ 12" DOWEL
#4 - CONT. BAR
CONCRETE SLAB ON
STEEL DECK
WELDED WIRE
REINFORCEMENT, TYP.
CL
1'-4"
DECK PARALLEL
BEAM AT DECK EDGE
OR OPENING EDGE
DECK CLOSURE PLATE,
THICKNESS TO MATCH DECK GAGE
FOR 0'-4" < D ≤ 1'-0", PROVIDE
HOOKED #4 DOWEL @ 12" O.C.
#4 - CONT. BAR
CONCRETE SLAB
ON STEEL DECK
WELDED WIRE
REINFORCEMENT, TYP.
CL
/4
D
6" TYP.
T Y
P
M A
X
PERPENDICULAR TO DECK SPAN
12" MAX.
14 GA SHEET FASTENED
TO STEEL DECK
STEEL DECK
SPAN DIRECTION
#10 SCREW INTO
EACH DECK FLUTE
TYP.
C4X5.4 AT EACH SIDE OF
OPENING. EXTEND TO 3 FLUTES
BEYOND OPENING EACH SIDE
PERPENDICULAR TO DECK SPAN
24" MAX.
OPENING (PERP. TO
DECK SPAN) ≤ 12"
12" < OPENING (PERP. TO DECK SPAN) ≤ 24"
NOTES:
1. OPENINGS LESS THAN 6" PERPENDICULAR TO THE DECK SPAN DO NOT REQUIRE REINFORCEMENT.
2. SEE SPACING DETAIL FOR CLUSTERED PENETRATION REQUIREMENTS.
STEEL DECK
SPAN DIRECTION
D D
MIN.
2D
MIN.
2D
D
NOTES:
1. PROVIDE MIN. SPACING AS NOTED BETWEEN CLUSTERED PENETRATIONS.
2. IF MIN. SPACING CANNOT BE PROVIDED, CONSIDER THE CLUSTERED
PENETRATIONS AS ONE OPENING MEASURING TO THE OUTER DIMENSIONS OF
THE END PENETRATIONS. REINFORCE THE DECK AS REQUIRED PER TYP. DETAILS.
DECK PENETRATION, TYP.
CLUSTERED PENETRATION
OPENING BOUNDARY PER NOTE 2
HSS BEAM, SEE PLAN
L8x4x1/2 AT EACH SIDE OF
GUIDERAIL SUPPORT
POST WITH 2"-LONG
VERTICAL SLOTTED HOLES
(2) 1/2"Ø
THROUGH-BOLTS
ELEVATOR GUIDERAIL
SUPPORT POST
SLAB ON STEEL
DECK, SEE PLAN
ELEVATOR HOISTWAY
/4
3/16
WF COLUMN,
SEE SCHEDULE
L4x4x3/8 LEDGER, TYP.
FOR STEEL DECK
SUPPORT AT COLUMNS
COPE ANGLE
LEGS AS NEEDED
PL1/4 TAB WITH
(2) 1/2"Ø BOLTS, TYP.
WF BEAM, SEE PLAN
TYP.
1" C
LR
NOTES:
1. STEEL DECK NOT SHOWN FOR CLARITY.
2. CONTRACTOR TO COORDINATE DECK SUPPORT WITH
CONNECTIONS AND OTHER CONDITIONS AT EACH COLUMN, TYP.
15 14.9
LID STEEL DECK
PERIMETER
BEAM, SEE PLAN
400S162-43 KICKER STUD
AT EACH STANCHION
400S162-43 STUDS. COPE END FLANGES AS
NEEDED. CONNECT TO STANCHION WITH 18 GA
2X2 ANGLE CLIP WITH (2) #10 SCREWS EACH LEG
400S162-43 STANCHION @ 6'-0" MAX.
ALIGNED OVER PERIMETER WF
BEAM CENTERLINE
CONTINUOUS
7"X7" 20 GA BENT
PLATE TOEBOARD
400T125-43 CONTINUOUS
TRACK WITH (2) #10 SCREWS
@ 24" INTO LID DECK
DECK PERPENDICULAR
WP
WP
400T125-43 CAP TRACK WITH
(2) #10 SCREWS EACH LEG
LID DECK FINISH
EXISTING ROOF
TRUSS MEMBER
3'-0"
(2) #10 SCREWS
600T125-43 CONTINUOUS
TRACK WITH (2) #10 SCREWS
@ 24" INTO LID DECK
M L.9
T.O. STEEL LID
939' - 1"
3'-0"
LID STEEL DECK
PERIMETER
BEAM, SEE PLAN
EXISTING ROOF TRUSS
OR BRIDGING MEMBER
400S162-43 KICKER STUD
AT EACH STANCHION
400S162-43 STUDS. COPE END FLANGES AS
NEEDED. CONNECT TO STANCHION WITH 18 GA
2X2 ANGLE CLIP WITH (2) #10 SCREWS EACH LEG
400S162-43 STANCHION @ 6'-0" MAX.
ALIGNED OVER PERIMETER WF
BEAM CENTERLINE
(2) #10 SCREWS
CONTINUOUS
7"X7" 20 GA BENT
PLATE TOEBOARD
400T125-43 CONTINUOUS
TRACK WITH (2) #10 SCREWS
@ 24" INTO LID DECK
DECK PARALLEL
WP
WP
400T125-43 CAP TRACK WITH
(2) #10 SCREWS EACH LEG
LID DECK FINISH
600T125-43 CONTINUOUS
TRACK WITH (2) #10 SCREWS
@ 24" INTO LID DECK
GRAPHIC SCALES
SCALE: 1 1/2"=1'-0"
1/2 1 21
SCALE: 1"=1'-0"
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
L O
U
IS
V
IL
L E
D
IS
T R
IC
T
D
R
M A
R T
IN
L
U T
H E
R K
IN
G
P L
L O
U
IS
V
IL
L E
K
Y w w w .c e m s -a e .c o m
P
M
D a v e
Y e n s a n
P ro je c t:
C
.8
.3
C E
M S
S-506
T Y
P
IC
A L D
E C
K D
E T
A
IL
S
W R
IG
H
T -P
A T
T E
R S
O N
A
IR
F O
R C
E B
A S
E B
M
IN
O
R
C H
A N
L E
Y
J L
I
J
U N
- - 4
P
N
U M
B E
R
D R
A W
IN
G
C O
D E
C E
R T
IF
IE
D F
IN
A
L S
U B
M
IT
T A
L
R E
N O
V A
T E
R E
S E
A R
C H
F A
C
IL
IT
Y
F O
R M
S
A -F
P R
O J E
C T
N U
M B
E R
Z
H T
V
SCALE: 1" = 1'-0"H1
TYPICAL STEEL DECK EDGE DETAILS
SCALE: 1" = 1'-0"K9
STEEL DECK OPENING REINFORCEMENT DETAILS
SCALE: 1" = 1'-0"E13
STEEL DECK PENETRATION SPACING
SCALE: 1" = 1'-0"
B2
S-402 G9
ELEVATOR GUIDERAIL SUPPORT POST HEAD DETAIL
SCALE: 1 1/2" = 1'-0"B13
TYP. STEEL DECK DETAIL AT COLUMN
SCALE: 1" = 1'-0"
C1
S-104 B1
LID GUARDRAIL DETAILS
A
M E
N D
M E
N T
J U
L
No. 29581
S
O
UT
H CAROLIN
A
B
R A D L E Y W. M I N
O
R
L I C E N S E D
P
RO
FESS I ONA L
E N G I N E E R
-J
UL-
W
2Q R
R
_P la ns -0
BASEMENT BASEMENT
879' - 9" 879' - 9"
FIRST FLOOR FIRST FLOOR
900' - 0" 900' - 0"
SECOND
FLOOR
SECOND
FLOOR
913' - 0" 913' - 0"
THIRD FLOOR THIRD FLOOR
926' - 0" 926' - 0"
LID LID
939' - 3" 939' - 3"
Column Locations G.5-12.1 H.5-12.1 H.5-13.2 H.5-14.4 H.5-14.4(2' - 1") H.5-14.9
H.5(-3' - 10")-14.9(2' - 0")
H.5(-3' - 10")-14.9(3' - 8")
J(-5")-14.4(2' - 1")
J(-5")-14.9 J(-5")-14.9(3' -
8") J.4-13.2 J.9-13.2 J.9(-4' - 3")-14.9 L(5' - 1")-14.9 L.2-12.1 L.2-13.2 L.2-14.4 L.9-12.1 L.9-14.9
W X
W X
H S
S X
X
/4
H S
S X
X
/1
H S
S X
X
/2
H S
S X
X
/1
H S
S X
X
/1
H S
S X
X
/1
W X
H S
S X
X
/1
H S
S X
X
/1
W X
W X
H S
S X
X
/8
W X
H S
S X
X
/1
W X
TYPE C TYPE A TYPE A TYPE G TYPE D TYPE C TYPE D TYPE E TYPE D TYPE C TYPE D TYPE A TYPE A TYPE C TYPE C TYPE A TYPE A TYPE B TYPE A TYPE CBASE
PLATE
W X
W X
W X
H S
S X
X
/4
H S
S X
X
/1
H S
S X
X
/8
W X
W X
W X
W X
H S
S X
X
/1
H S
S X
X
/1
H S
S X
X
/1
H S
S X
X
/1
H S
S X
X
/2
H S
S X
X
/1
H S
S X
X
/1
W X
W X
W X
H S
S X
X
/4
W X
W X
W X
W X
H S
S X
X
/1
H S
S X
X
/8
H S
S X
X
/1
H S
S X
X
/1
H S
S X
X
/1
H S
S X
X
/1
H S
S X
X
/2
H S
S X
X
/1
H S
S X
X
/1
COLUMN
LOCATIONS
H S
S X
X
/1
H S
S X
X
/1
H S
S X
X
/1
H S
S X
X
/1
H S
S X
X
/1
H S
S X
X
/1
H S
S X
X
/1
H S
S X
X
/1
H S
S X
X
/1
4" 6" 4"
N
B B
N
1 1/2" 8" 1 1/2"
B
N
TYPE A TYPE B TYPE C
6" 4" 6"
TYPE D
10"
2" 3" 2"
NOTES:
1. PROVIDE 1-5/16"Ø OVERSIZED HOLES FOR BASE PLATE ANCHOR RODS.
2. PROVIDE PL1/4x2x0'-2" PLATE WASHERS AT EACH ANCHOR ROD. PROVIDE A 3/16" FILLET AT ALL SIDES.
3. PROVIDE A 3/16" FILLET AT ALL FLAT INTERFACES COLUMN TO BASE PLATE. WHERE COLUMNS ALIGN WITH
PLATE EDGES, PROVIDE A 3/16" PJP WELD.
4. BASE PLATES MAY NOT PROJECT INTO ELEVATOR SHAFT. BASE PLATE EDGE DIMENSIONS MAY BE ADJUSTED
UP TO ± 1/2" AS NEEDED. VERIFY 1-1/8" MIN. DISTANCE PLATE EDGE TO ROD CENTERLINE.
5. THE DESIGNS OF BASE PLATES TYPE F AND G ARE PENDING REVIEW AND APPROVAL OF THE LOCATION OF
THE SUPPORT TUBES FOR THE ELEVATOR GUIDERAILS. THE CONTRACTOR SHALL COORDINATE ACCORDINGLY.
TYPE E
10"
/2
2" 3" 2"
TYPE F
2 1/2" 3" 2 1/2"
/2
/2
TYPE G
N
B
N
B
/4
/2
/2
/2
/4
/2
/2
2"
/2
3"
/2
/2
3"
2"
4"
/2
3" 8
3"
/4
3"
3"
/4
/2
5 1/2"
8"
7"
BASE PLATE SCHEDULE
TYPE
A
B
C
THICKNESS [IN]
1"
1"
1"
B [IN]
N [IN]
ANCHOR RODS
(4) 3/4" Ø
(4) 3/4" Ø
(4) 3/4" Ø
ROD EMBED. [IN]
8" MIN.
8" MIN.
8" MIN.
D 1" SEE DETAIL FOR DIM. (4) 3/4" Ø 8" MIN.
E 1" (4) 3/4" Ø 8" MIN.
F
SEE DETAIL FOR DIM.
G
1"
8 24
(4) 3/4" Ø 8" MIN.
1" (4) 3/4" Ø 8" MIN.
8 16
878'-9" 878'-9" 878'-9" 879'-9" 879'-9" 879'-0" 879'-9" 879'-9" 879'-9" 879'-9"879'-0" 878'-9" 878'-9" 878'-9" 878'-9" 878'-9" 878'-9" 878'-9" 878'-9" 878'-9" T.O.
FOUNDATION
EL:
CL
PJP
NOTES:
1. SPLICE CONCEPT SHOWN. SPLICES TO BE DESIGNED
BY DELEGATED CONNECTIONS DESIGNER.
2. REFER TO GRAVITY COLUMN SCHEDULE FOR
COLUMN SIZES AND SPLICE LOCATIONS.
3. PROVIDE MILLED FINISHES AT COLUMN ENDS.
SLIP-CRITICAL BOLTS
CHANNEL FOR BOLTED WEB SPLICE
LIFTING HOLE AT CONTRACTOR'S OPTION
WF GRAVITY COLUMN
A B
O V
E F
L O
O R
L E
V E
L
CL
4 SIDES,
TYP.
NOTES:
1. SPLICE CONCEPT SHOWN. SPLICES TO BE DESIGNED
BY DELEGATED CONNECTIONS DESIGNER.
2. REFER TO GRAVITY COLUMN SCHEDULE FOR COLUMN
SIZES AND SPLICE LOCATIONS.
3. PROVIDE MILLED FINISHES AT COLUMN ENDS.
HSS GRAVITY COLUMN
1/4"
SPLICE BEARING PLATE
A B
O V
E F
L O
O R
L E
V E
L
G R
O U
T
/2
N
O N
-S H
R
IN
K
HEAVY HEX NUT
AND WASHER
HEAVY HEX NUT AND 3"x3"
PLATE WASHER @ W10 AND
W12 (STD. WASHER @ HSS
COLUMN OPTIONAL)
BASE PLATE
LEVELING NUT
3/4"Ø OR 1"Ø (ASTM
F1554) ANCHOR ROD
T.O. CONC. FOUNDATION
P R
O J
T H
R E
A D
E M
B E
D
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
L O
U
IS
V
IL
L E
D
IS
T R
IC
T
D
R
M A
R T
IN
L
U T
H E
R K
IN
G
P L
L O
U
IS
V
IL
L E
K
Y w w w .c e m s -a e .c o m
P
M
D a v e
Y e n s a n
P ro je c t:
C
.8
.3
C E
M S
S-601
G R
A V
IT
Y
C O
L U
M N
S C
H E
D U
L E
A N
D D
E T
A
IL
S
W R
IG
H
T -P
A T
T E
R S
O N
A
IR
F O
R C
E B
A S
E B
M
IN
O
R
P
M U
R R
E N
J L
I
J
U N
- - 4
P
N
U M
B E
R
D R
A W
IN
G
C O
D E
C E
R T
IF
IE
D F
IN
A
L S
U B
M
IT
T A
L
R E
N O
V A
T E
R E
S E
A R
C H
F A
C
IL
IT
Y
F O
R M
S
A -F
P R
O J E
C T
N U
M B
E R
Z
H T
V
SCALE: 1 1/2" = 1'-0"A10
BASE PLATE SCHEDULE AND DETAILS
SCALE: NOT TO SCALEG1
GRAVITY COLUMN SCHEDULE
COLUMN SPLICE, TYP.
SCALE: 1" = 1'-0"A1
WF GRAVITY COLUMN SPLICE
SCALE: 1" = 1'-0"A6
HSS GRAVITY COLUMN SPLICE
1/2 1 21
SCALE: 1"=1'-0"
SCALE: 1 1/2"=1'-0"
GRAPHIC SCALES
SCALE: NOT TO SCALEL18
ANCHOR ROD DETAIL
A
M E
N D
M E
N T
J U
L
No. 29581
S
O
UT
H CAROLIN
A
B
R A D L E Y W. M I N
O
R
L I C E N S E D
P
RO
FESS I ONA L
E N G I N E E R
-J
UL-
W
2Q R
R
_P la ns -0
T.O. WALL
BO WALL
PLAN VIEW
CONTINUOUS STEEL RUNNER
BASE PER FINISH SCHEDULE
SEE BO WALL TERMINATION
DETAILS
DEFLECTION TRACK
ACOUSTIC INSULATION
WHERE INDICATED
STEEL STUD FRAMING AT 16" OC
ROOF OR FLOOR ASSEMBLY
FLOOR ASSEMBLY
EXTEND FINISH CONSTRUCTION
3" MIN. ABOVE CEILING
FINISH CONSTRUCTION PER
PARTITION TYPE TAG
SEE T.O. WALL TERMINATION
DETAILS
T.O. WALL
BO WALL
PLAN VIEW
ATTACHABLE SURFACE
EDGE FURRING CHANNELS AS
REQUIRED
BASE PER FINISH SCHEDULE
SEE BO WALL TERMINATION
DETAILS
EDGE FURRING CHANNELS ONLY
AT WALLS THAT EXTEND TO DECK
HORIZONTAL OR VERTICAL
FURRING AT 16" OC MAX
ROOF OR FLOOR ASSEMBLY
FLOOR ASSEMBLY
EXTEND FINISH CONSTRUCTION
3" MIN. ABOVE CEILING
FINISH CONSTRUCTION PER
PARTITION TYPE TAG
SEE T.O. WALL TERMINATION
DETAILS
THERMAL INSULATION WHERE
INDICATED
VAPOR BARRIER AT EXT. WALL
OR WHERE NOTED
T.O. WALL
BO WALL
PLAN VIEW
1" SHAFTWALL LINER PANEL
CONTINUOUS STEEL RUNNER
BASE PER FINISH SCHEDULE
SEE BO WALL TERMINATION
DETAILS
DEFLECTION TRACK
ACOUSTIC INSULATION
WHERE INDICATED
SHAFTWALL STUD FRAMING
AT 16" OC
ROOF OR FLOOR ASSEMBLY
FLOOR ASSEMBLY
EXTEND FINISH CONSTRUCTION
3" MIN. ABOVE CEILING
FINISH CONSTRUCTION PER
PARTITION TYPE TAG
SEE T.O. WALL TERMINATION
DETAILS
FIRE RATING (HR)
CORE MATERIAL
CORE THICKNESS MARK
FINISH CONSTRUCTION TYPE
SEPARATOR (PERIOD) F - FURRING
H - SHAFT
M - MASONRY
S - STEEL
X - ETR-FV
MASONRY
DEPTH
3 5/8"
7/8"
STEEL
DEPTH
1 1/2" 2 1/2" 3 5/8"
4" 6 5 5/8" 6" 8 7 5/8" 8"
12 11 5/8" 12"
CORE THICKNESS GUIDE:
10 9 5/8" 10"
MARK
(NOMINAL)
X VIF VIFSMOKE RATED
ACOUSTIC RATED
S3A.1sat
CORE MATERIALS:
THERMALLY RATED
NOTE:
1. SEE PARTITION TYPES SCHEDULE AND FINISH TYPES AND DESCRIPTIONS SCHEDULE FOR MORE INFO. SOME TYPES INDICATED
MAY NOT BE USED IN PROJECT.
2. ACOUSTICALLY RATED STUD WALLS: STUD WALLS INDICATED TO MEET A MINIMUM STC RATING HAVE PARTITION TYPE TAGS WITH A
SUBSCRIPT "a" AND SHALL HAVE ACOUSTICAL BATT INSULATION ADDED ACCORDINGLY BETWEEN THE STUDS. ACOUSTIC INSULATION SHALL BE FULL DEPTH OF THE STUD UNLESS NOTED OTHERWISE. WALLS WITH A SUBSCRIPT "a" ARE TO HAVE THE ACOUSTICAL RATING EXTENDED FROM FLOOR TO UNDERSIDE OF ROOF DECK ABOVE UNLESS AN ACOUSTICALLY RATED GYPSUM
BOARD CEILING IS INDICATED WITHIN THE ROOM BOUNDED BY THESE WALLS.
3. THERMALLY RATED STUD WALLS: STUD WALLS INDICATED TO MEET A MINIMUM R-VALUE HAVE PARTITION TYPE TAGS WITH A SUBSCRIPT "t" AND SHALL HAVE THERMAL BATT INSULATION ADDED ACCORDINGLY BETWEEN THE STUDS. THERMAL BATT INSULATION SHALL BE FULL DEPTH OF THE STUD UNLESS NOTED OTHERWISE. WALLS WITH A SUBSCRIPT "t" ARE TO HAVE THE THERMAL RATING EXTENDED FROM FLOOR TO UNDERSIDE OF FLOOR OR ROOF DECK ABOVE UNLESS A THERMALLY RATED
GYPSUM BOARD CEILING IS INDICATED WITHIN THE ROOM BOUNDED BY THESE WALLS.
4. FURRED WALLS INDICATED WITH RIGID THERMAL INSULATION ARE TO HAVE INSULATION THE FULL DEPTH OF THE FURRING UNLESS
NOTED OTHERWISE.
5. WALLS INDICATED WITH A FIRE OR SMOKE RATING ARE TO HAVE THAT RATING EXTENDED FROM FLOOR TO UNDERSIDE OF FLOOR OR ROOF DECK ABOVE UNLESS A RATED GYPSUM BOARD CEILING IS INDICATED WITHIN THE ROOM BOUNDED BY THESE RATED
WALLS.
1. METAL STUD DESIGN CRITERIA: ALL INTERIOR NON-LOAD BEARING METAL STUDS SHALL BE 25 GAUGE MINIMUM UNLESS OTHERWISE NOTED. STUDS SHALL BE DESIGNED FOR A MINIMUM 5 PSF APPLIED LATERAL LOAD WITH MINIMUM L/240 DEFLECTION UNLESS MORE STRINGENT REQUIREMENTS ARE REQUIRED FOR FINISHES. STUD THICKNESS GAUGE AND DEPTHS INDICATED ARE MINIMUMS. STUD DEPTHS INDICATED ARE MAXIMUMS. MAXIMUM STUD SPACING IS 16 INCHES ON CENTER. STUD GAUGES ARE TO BE INCREASED AND OR ON CENTER SPACINGS ARE TO BE DECREASED AS REQUIRED TO MEET LOADING AND DEFLECTION REQUIREMENTS. STUD GAUGES ARE TO BE THICKER AS REQUIRED TO MEET SCREW RETENTION REQUIREMENTS AS STATED BY FINISH MATERIALS MANUFACTURERS. AT ALL WALL SUPPORTED CABINETS, EQUIPMENT, FIXTURES AND SO FORTH, PROVIDE MINIMUM 20 GAUGE (30 MILS) STUDS. FINAL STUD GAUGE, FLANGE DEPTH, FLANGE RETURN LENGTH AND STUD O.C. SPACINGS ARE TO BE DESIGN BY STUD MANUFACTURER FOR LOADINGS INDICATED AND WITHIN LIMITATIONS INDICATED
HEREIN.
2. DIMENSIONS SHOWN ON 1/16”, 3/32”, 1/8”, AND 3/16” SCALE DRAWINGS ARE FROM FACE OF CORE
MATERIAL, COLUMN CENTERLINE, AND EDGE OF ROUGH OPENINGS.
3. DIMENSIONS SHOWN ON 1/4” AND GREATER SCALE DRAWINGS ARE FROM FACE OF FINISH MATERIAL, COLUMN CENTERLINE, AND OR EDGE OF FINISH OPENINGS.
4. INSTALLATION OF GYPSUM BOARD, BACKER BOARD, AND BASE BOARD SHALL CONFORM TO
REQUIREMENTS FOR FIRE RATINGS AND ACOUSTICAL RATINGS.
5. AT METAL STUD WALLS THAT ARE NOTED IN ROOM FINISH SCHEDULE TO RECEIVE CERAMIC OR
PORCELAIN TILE FINISH PROVIDE 5/8” CEMENT BACKER BOARD.
6. ALL GYPSUM BOARD TO BE 5/8" UNLESS OTHERWISE NOTED.
7. AT FIRE RATED METAL STUD PARTITIONS: PROVIDE 5/8" TYPE X GYPSUM BOARD. UNLESS NOTED
OTHERWISE, EXTEND GWB TO THE UNDERSIDE OF THE DECK ABOVE AND CUT TO FIT WITHIN A 1/4" MAXIMUM TOLERANCE TO THE SHAPE OF THE DECK ABOVE. PROVIDE CONTINUOUS FIRE RATED SEALANT FOR THE FULL DEPTH OF THE GWB . REFER TO THE FLOOR PLAN FOR EXTENT OF FIRE RATED WALLS.
8. GYPSUM ASSOCIATION (IF NOTED) AND UL TEST NUMBERS WILL VARY DEPENDING ON THE
MANUFACTURER OF COMPONENTS ACTUALLY USED.
9. PRIOR TO INSTALLING WALL FINISH MATERIALS: INSTALL WOOD OR METAL STUD BLOCKING OR BACKER
MATERIAL CONCEALED WITHIN THE STUD CAVITY FOR ATTACHMENT AND MOUNTING OF WALL
SUPPORTED ITEMS. CONTRACTOR SHALL VERIFY CONCEALED BLOCKING AND/OR BACKER
REQUIREMENTS WITH MANUFACTURER OF ITEM FOR ALL WALL SUPPORTED ITEMS AND CONTRACTOR SHALL VERIFY FINAL LOCATION OF ALL ITEMS WITH CONTRACTING OFFICER PRIOR TO INSTALLATION OR
REQUIRED BLOCKING AND/OR BACKING.
10. WHEN INSTALLING GYPSUM WALL BOARD (GWB), CONTRACTOR SHALL COMPLY WITH REQUIREMENTS OF THE MOST CURRENT EDITION OF THE GYPSUM ASSOCIATION GA-600 FIRE RESISTANCE DESIGN MANUAL
AND THE MOST CURRENT EDITION OF THE UL FIRE RESISTANCE DIRECTORY.
11. GYPSUM WALL BOARD SHALL BE CUT SO THAT THE CLEARANCE BETWEEN…